In order to improve the steady state performance,dynamic response and power factor of traditional power factor correction(PFC)digital control method and reduce the harmonic distortion of input current,a double closed ...In order to improve the steady state performance,dynamic response and power factor of traditional power factor correction(PFC)digital control method and reduce the harmonic distortion of input current,a double closed loop active power factorcorrection(APFC)control method with feed-forward is proposed.Firstly,the small signal model of Boost PFC control systemis built and the system transfer function is deduced,and then the parameters of the main device with Boost topology is estimated.By means of the feed-forward,the system can quickly respond to the change in input voltage.Furthermore,the use ofvoltage loop and current loop can achieve input current and output voltage regulation Simulink modeling shows that this methodcan effectively control the output voltage in case of input voltage largely fluctuating,improve the system dynamic response abilityand input power factor,and reduce the input current harmonic distortion展开更多
To reduce current harmonics caused by switching frequency,T-type grid-connected inverter topology with LCL filter is adopted.In view of the disadvantages of the slow response speed of the traditional current control a...To reduce current harmonics caused by switching frequency,T-type grid-connected inverter topology with LCL filter is adopted.In view of the disadvantages of the slow response speed of the traditional current control and the failure to eliminate the influence of the LCL filter on the grid-connected current by using current PI control alone,a current double closed loop PI current tracking control is proposed.Through the theoretical analysis of the grid-connected inverter control principle,the grid-connected inverter control model is designed,and the transfer functionmodel of each control link is deduced,and the current loop PI regulator is designed at last.The simulation results show that the control strategy is feasible.展开更多
合环电流评估技术对于配电网馈线合环转供电操作具有重要意义,为了提高主动配电网馈线合环电流计算的准确性,文中从融入源荷数据分布特性及预测的角度,提出基于双重K2算法和概率潮流(double K2 algorithm and probability load flow,DK2...合环电流评估技术对于配电网馈线合环转供电操作具有重要意义,为了提高主动配电网馈线合环电流计算的准确性,文中从融入源荷数据分布特性及预测的角度,提出基于双重K2算法和概率潮流(double K2 algorithm and probability load flow,DK2-PLF)的主动配电网馈线合环电流评估方法。首先,采用基于DK2算法的贝叶斯网络描述源荷相关性样本;其次,利用Cholesky分解方法处理获得的源荷相关性样本,以半不变量法计算主动配电网馈线合环电流的累积概率分布;然后,对主动配电网馈线合环电流从合环成功率和越限程度两方面进行安全性评估;最后,以贵州某城市为算例,对10 kV配电网系统开展馈线合环电流评估研究。得出以下结论:一是从概率密度、累积分布、最大误差三方面比较,相比于K2算法,DK2算法源荷预测值的概率密度、累积分布误差较小,验证了DK2算法的优越性;二是从累积分布、最大误差两方面比较,采用Cholesky分解的半不变量法对比未采用Cholesky分解的半不变量法、蒙特卡洛法,其累积分布误差较小,采用Cholesky分解的半不变量法满足主动配电网馈线合环电流评估要求;三是从合环成功率、合环越限程度两方面比较,采用半不变量法计算的合环电流安全性指标结果与仿真结果偏差在电网经验误差5%范围内,说明基于DK2-PLF的主动配电网馈线合环电流评估方法可为合环辅助决策提供参考。展开更多
基金National Natural Science Foundation of China(No.61261029)
文摘In order to improve the steady state performance,dynamic response and power factor of traditional power factor correction(PFC)digital control method and reduce the harmonic distortion of input current,a double closed loop active power factorcorrection(APFC)control method with feed-forward is proposed.Firstly,the small signal model of Boost PFC control systemis built and the system transfer function is deduced,and then the parameters of the main device with Boost topology is estimated.By means of the feed-forward,the system can quickly respond to the change in input voltage.Furthermore,the use ofvoltage loop and current loop can achieve input current and output voltage regulation Simulink modeling shows that this methodcan effectively control the output voltage in case of input voltage largely fluctuating,improve the system dynamic response abilityand input power factor,and reduce the input current harmonic distortion
基金Supported by Science and Technology Projects of State Grid Corporation ofChina(J2022019).
文摘To reduce current harmonics caused by switching frequency,T-type grid-connected inverter topology with LCL filter is adopted.In view of the disadvantages of the slow response speed of the traditional current control and the failure to eliminate the influence of the LCL filter on the grid-connected current by using current PI control alone,a current double closed loop PI current tracking control is proposed.Through the theoretical analysis of the grid-connected inverter control principle,the grid-connected inverter control model is designed,and the transfer functionmodel of each control link is deduced,and the current loop PI regulator is designed at last.The simulation results show that the control strategy is feasible.
文摘合环电流评估技术对于配电网馈线合环转供电操作具有重要意义,为了提高主动配电网馈线合环电流计算的准确性,文中从融入源荷数据分布特性及预测的角度,提出基于双重K2算法和概率潮流(double K2 algorithm and probability load flow,DK2-PLF)的主动配电网馈线合环电流评估方法。首先,采用基于DK2算法的贝叶斯网络描述源荷相关性样本;其次,利用Cholesky分解方法处理获得的源荷相关性样本,以半不变量法计算主动配电网馈线合环电流的累积概率分布;然后,对主动配电网馈线合环电流从合环成功率和越限程度两方面进行安全性评估;最后,以贵州某城市为算例,对10 kV配电网系统开展馈线合环电流评估研究。得出以下结论:一是从概率密度、累积分布、最大误差三方面比较,相比于K2算法,DK2算法源荷预测值的概率密度、累积分布误差较小,验证了DK2算法的优越性;二是从累积分布、最大误差两方面比较,采用Cholesky分解的半不变量法对比未采用Cholesky分解的半不变量法、蒙特卡洛法,其累积分布误差较小,采用Cholesky分解的半不变量法满足主动配电网馈线合环电流评估要求;三是从合环成功率、合环越限程度两方面比较,采用半不变量法计算的合环电流安全性指标结果与仿真结果偏差在电网经验误差5%范围内,说明基于DK2-PLF的主动配电网馈线合环电流评估方法可为合环辅助决策提供参考。