In large mines,single fan is usually not enough to ventilate all the working areas.Single mine-fan approach cannot be directly applied to multiple-fan networks because the present of multiple pressures and air quantit...In large mines,single fan is usually not enough to ventilate all the working areas.Single mine-fan approach cannot be directly applied to multiple-fan networks because the present of multiple pressures and air quantities associated with each fan in the network.Accordingly,each fan in a multiple-fan system has its own mine characteristic curve,or a subsystem curve.Under some consideration,the conventional concept of a mine characteristic curve of a single-fan system can be directly extended to that of a particular fan within a multiple-fan system.In this paper the mutual effect of the fans on each other and their effect on the stability of the ventilation network were investigated by Hardy Cross algorithm combined with a switching-parameters technique.To show the validity and reliability of this algorithm,the stability of the ventilation system of Abu-Tartur Mine(one of the largest underground mine in Egypt)has been studied.展开更多
The causes of an offensive odor in the kitchens,bathrooms,and toilets of residential apartments in multi-story buildings with natural ventilation in Tomsk,Russia,are discussed in this paper.This problem exists in othe...The causes of an offensive odor in the kitchens,bathrooms,and toilets of residential apartments in multi-story buildings with natural ventilation in Tomsk,Russia,are discussed in this paper.This problem exists in other cities and countries.Wall electric fans can be installed in ventilation grills in kitchens,bathrooms,and toilets of apartments in multi-story residential buildings.Typically,these fans turn on with the light in the bathroom or toilet,so the problem is periodic.Forced airflow from a fan in one apartment disrupts the natural outflow of air in the ventilation system of a residential building designed and built according to building codes and regulations and can cause an unpleasant smell in neighboring apartments.In many cases,it is difficult to determine which apartments have fans and force the neighbors to remove them.Locally,on the scale of one apartment,the problem is solved by installing an air check valve in the ventilation grill,which will block the nuisance airflow from the ventilation system into the bathroom.Globally,the problem is solved by modification and subsequent compliance with building codes and regulations,the implementation of which is controlled by local authorities.展开更多
The aim of this study was to analyse air exchange and temperature distribution in a greenhouse with combined mechanical and natural ventilation and to design more efficient mechanical ventilation systems.For this purp...The aim of this study was to analyse air exchange and temperature distribution in a greenhouse with combined mechanical and natural ventilation and to design more efficient mechanical ventilation systems.For this purpose,a computational fluid dynamics(CFD)model of the greenhouse was used.Three configurations were considered:Configuration 1(mechanical ventilation and closed roof ventilators),Configurations 2 and 3(mechanical ventilation and roof ventilators open 30%and 100%,respectively).After validation,the CFD model was used to improve the design of the greenhouse mechanical ventilation system in each of the three configurations analyzed.Four greenhouse lengths,28 m,50 m,75 m and 100 m,were used in the simulations.Compared to fan ventilation only,roof ventilation improved the climate of fan-ventilated greenhouses in terms of the air exchange rate(22%)and climate uniformity because the internal air was mixed better than with mechanical ventilation only.As the greenhouse length increased,more advantages were achieved with natural ventilation compared to mechanical ventilation.For most configurations,there was a strong linear correlation between temperature gradient and greenhouse length.The greenhouse whose regression line had the steepest slope was the one with closed roof ventilators.Increasing the fan capacity produced a general reduction in temperature,but the effect was less intense for the greenhouses with open roof ventilators.Compared to box inlet ventilators,an enlarged continuous inlet in the wall opposite the fans increased overall system performance because it eliminated backflow recirculation zones,which are prone to produce high temperatures.展开更多
文摘In large mines,single fan is usually not enough to ventilate all the working areas.Single mine-fan approach cannot be directly applied to multiple-fan networks because the present of multiple pressures and air quantities associated with each fan in the network.Accordingly,each fan in a multiple-fan system has its own mine characteristic curve,or a subsystem curve.Under some consideration,the conventional concept of a mine characteristic curve of a single-fan system can be directly extended to that of a particular fan within a multiple-fan system.In this paper the mutual effect of the fans on each other and their effect on the stability of the ventilation network were investigated by Hardy Cross algorithm combined with a switching-parameters technique.To show the validity and reliability of this algorithm,the stability of the ventilation system of Abu-Tartur Mine(one of the largest underground mine in Egypt)has been studied.
基金support from the Government of the Russian Federation (Mega grant No.075-15-2021-612 of June 4,2021) for funding scientific research in Russia.
文摘The causes of an offensive odor in the kitchens,bathrooms,and toilets of residential apartments in multi-story buildings with natural ventilation in Tomsk,Russia,are discussed in this paper.This problem exists in other cities and countries.Wall electric fans can be installed in ventilation grills in kitchens,bathrooms,and toilets of apartments in multi-story residential buildings.Typically,these fans turn on with the light in the bathroom or toilet,so the problem is periodic.Forced airflow from a fan in one apartment disrupts the natural outflow of air in the ventilation system of a residential building designed and built according to building codes and regulations and can cause an unpleasant smell in neighboring apartments.In many cases,it is difficult to determine which apartments have fans and force the neighbors to remove them.Locally,on the scale of one apartment,the problem is solved by installing an air check valve in the ventilation grill,which will block the nuisance airflow from the ventilation system into the bathroom.Globally,the problem is solved by modification and subsequent compliance with building codes and regulations,the implementation of which is controlled by local authorities.
基金This research work was partially financed by the EUPHOROS project,Efficient Use of inputs in Protected Horticulture,the Seventh EU Framework Programme and INIA project RTA(2008-00109-C03-01).
文摘The aim of this study was to analyse air exchange and temperature distribution in a greenhouse with combined mechanical and natural ventilation and to design more efficient mechanical ventilation systems.For this purpose,a computational fluid dynamics(CFD)model of the greenhouse was used.Three configurations were considered:Configuration 1(mechanical ventilation and closed roof ventilators),Configurations 2 and 3(mechanical ventilation and roof ventilators open 30%and 100%,respectively).After validation,the CFD model was used to improve the design of the greenhouse mechanical ventilation system in each of the three configurations analyzed.Four greenhouse lengths,28 m,50 m,75 m and 100 m,were used in the simulations.Compared to fan ventilation only,roof ventilation improved the climate of fan-ventilated greenhouses in terms of the air exchange rate(22%)and climate uniformity because the internal air was mixed better than with mechanical ventilation only.As the greenhouse length increased,more advantages were achieved with natural ventilation compared to mechanical ventilation.For most configurations,there was a strong linear correlation between temperature gradient and greenhouse length.The greenhouse whose regression line had the steepest slope was the one with closed roof ventilators.Increasing the fan capacity produced a general reduction in temperature,but the effect was less intense for the greenhouses with open roof ventilators.Compared to box inlet ventilators,an enlarged continuous inlet in the wall opposite the fans increased overall system performance because it eliminated backflow recirculation zones,which are prone to produce high temperatures.