期刊文献+
共找到20,639篇文章
< 1 2 250 >
每页显示 20 50 100
Operating Parameters of the District Heating Substation Cooperating With the Installation of Technological Air Conditioning With High Efficiency of Heat Recovery
1
作者 Żarski Kazimierz Kryża Mariusz 《Chinese Business Review》 2024年第1期1-12,共12页
The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchange... The article analyses the problem of determining the operating parameters of the district heating substation cooperating with the air heating system in technological air conditioning systems equipped with heat exchangers with high efficiency of heat recovery.Attention was paid to the correct selection of heat exchangers for the heat output balance depending on the heat recovery protection algorithms against a drop in the temperature of the heat transfer surface below 0℃.Critical parameters were determined in Polish climatic conditions,at which the operation of the heat recovery exchanger in the air conditioning system is switched off or limited.It has been proven that the proper functioning of the district heating substation cooperating with the installation of air conditioning with high heat recovery efficiency requires the use of two heat exchangers with different characteristics,equipped with properly selected temperature control systems.The optimal model of cooperation between the technological air conditioning system and the heating substation was also indicated. 展开更多
关键词 ventilation of operating theatre air conditioning flow control in heating circuit
下载PDF
Wind-Thermal Environmental Characteristic of Multi-Variable Passive Enhanced Natural Ventilation System for High and Large Space Building
2
作者 Lin Liu Haoran Huang +2 位作者 Chenghe Wu Liru Liu Jing Tian 《Journal of Harbin Institute of Technology(New Series)》 CAS 2023年第5期34-51,共18页
Natural ventilation effects in high and large space buildings of tropical areas greatlya ffect the air conditioning energy consumption.Aiming at nearly zero energy building design,thisp aper mainly contributes to prov... Natural ventilation effects in high and large space buildings of tropical areas greatlya ffect the air conditioning energy consumption.Aiming at nearly zero energy building design,thisp aper mainly contributes to provide theoretical basis and reference for thermal comfortable air conditioning system design of high and large space buildings.Taking a theatre in Hainan as study object,a newly composite enhanced natural ventilation system is proposed by integrating theu nderground tunnel-based earth to air heat exchange system and the solar chimney.Ventilationq uantity,air velocity and air temperature field,human vertical temperature gradient differenceu nder24simulation working conditions are considered and analyzed by using ANSYS Fluent.Fort he underground tunnel,results show that Group Two with double underground tunnels and side airs upply location shows its advantages in cooling effects and air supply uniformity.Then for the solar chimney,results show that the solar radiation intensity contributes to larger difference int ransmission power and leads to different cooling effects.On the whole,the system under workingc ondition No.7with120m long,side air supply,double underground tunnel and20m high,1mw ide,0.6°absorber plate angle solar chimney shows its priority in better comprehensive performance. 展开更多
关键词 natural ventilation solar chimney earth to air heat exchange system energyc onservation thermal environment
下载PDF
Analyses of an air conditioning system with entropy generation minimization and entransy theory 被引量:3
3
作者 吴艳秋 蔡黎 吴鸿娟 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第6期130-136,共7页
In this paper,based on the generalized heat transfer law,an air conditioning system is analyzed with the entropy generation minimization and the entransy theory.Taking the coefficient of performance(denoted as COP) ... In this paper,based on the generalized heat transfer law,an air conditioning system is analyzed with the entropy generation minimization and the entransy theory.Taking the coefficient of performance(denoted as COP) and heat flow rate Qout which is released into the room as the optimization objectives,we discuss the applicabilities of the entropy generation minimization and entransy theory to the optimizations.Five numerical cases are presented.Combining the numerical results and theoretical analyses,we can conclude that the optimization applicabilities of the two theories are conditional.If Qout is the optimization objective,larger entransy increase rate always leads to larger Qout,while smaller entropy generation rate does not.If we take COP as the optimization objective,neither the entropy generation minimization nor the concept of entransy increase is always applicable.Furthermore,we find that the concept of entransy dissipation is not applicable for the discussed cases. 展开更多
关键词 entropy generation entransy increase entransy dissipation optimization analyses finite time thermodynamics air conditioning system
下载PDF
System design and analysis of the trans-critical carbon-dioxide automotive air-conditioning system 被引量:2
4
作者 穆景阳 陈江平 陈芝久 《Journal of Zhejiang University Science》 EI CSCD 2003年第3期305-308,共4页
As an environmentally harmless and feasible alternate refrigerant, CO2 has attracted worldwide attention, especially in the area of automobile air-conditioning (AAC). The thermal property of CO2 and its trans-eritical... As an environmentally harmless and feasible alternate refrigerant, CO2 has attracted worldwide attention, especially in the area of automobile air-conditioning (AAC). The thermal property of CO2 and its trans-eritical refrigeration cycle is very different from that of the traditional CFC or HCFC system. The detailed process of CO2 system thermal cycle design and optimization is described in this paper. System prototype and performance test bench were developed to analyze the performance of the CO2 AAC system. 展开更多
关键词 自动空气调节系统 系统设计 二氧化碳 制冷剂 横向临界循环制冷
下载PDF
A Case Study:Distribution of Bacterial and Fungal Aerosols in Air-Conditioning Systems in Shaanxi History Museum
5
作者 LI An-gui,HOU Juan-juan,JI Zeng-bao,ZHU Xiao-bin(School of Environmental & Municipal Engineering,Xi’an University of Architecture and Technology,Xi’an,Shaanxi 710055,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期10-14,共5页
In order to investigate the bacteria and fungi aerosol characteristic distribution in HVAC-system and its components at Shaanxi History Museum.Measurements were performed to probe the bacteria and fungi aerosol in HVA... In order to investigate the bacteria and fungi aerosol characteristic distribution in HVAC-system and its components at Shaanxi History Museum.Measurements were performed to probe the bacteria and fungi aerosol in HVAC systems,located at Xi'an city,China.The results showed that there was fungi growth inside the ventilation ducts,fungi contamination was worse than bacteria,and both of them were distributed into occupied space with the air supply ducts.The dominating genera of fungi was found to be Penicillium spp.and Aspergillus spp.,which was respectively 46.1% and 20.7% in settling fungi,and the dominating genera of fungi in dust were Cladosporium spp.and Penicillium spp.,which was 41.8% and 30.1% respectively.It suggests that available measures to improve and control the performance of HVAC-systems such as the maintenance,management and cleaning should be taken to prevent this pollution and to develop strategies to keep this pollution away. 展开更多
关键词 central air conditioning MICROBE bacteria FUNGI contamination field experiment
下载PDF
The Experiment and Simulation of Solid Desiccant Dehumidification for Air-Conditioning System in a Tropical Humid Climate 被引量:1
6
作者 Juntakan Taweekun Visit Akvanich 《Engineering(科研)》 2013年第1期146-153,共8页
The aim of this research was to study and design a solid desiccant dehumidification system suitable for tropical climate to reduce the latent load of air-conditioning system and improve the thermal comfort. Different ... The aim of this research was to study and design a solid desiccant dehumidification system suitable for tropical climate to reduce the latent load of air-conditioning system and improve the thermal comfort. Different dehumidifiers such as desiccant column and desiccant wheel were investigated. The ANSYS and TRASYS software were used to predict the results of dehumidifiers and the desiccant cooling systems, respectively. The desiccant bed contained approximately 15 kg of silica-gel, with 3 mm average diameter. Results indicated that the pressure drop and the adsorption rate of desiccant column are usually higher than those of the desiccant wheel. The feasible and practical adsorption rate of desiccant wheel was 0.102 kgw/h at air flow rate 1.0 kg/min, regenerated air temperature of 55?C and at a wheel speed of 2.5 rpm. The humidity ratio of conditioning space and cooling load of split-type air conditioner was decreased to 0.002 kgw/kgda (14%) and 0.71 kWth (19.26%), respectively. Consequently, the thermal comfort was improved from 0.5 PMV (10.12% PPD) to 0.3 PMV (7.04% PPD). 展开更多
关键词 SOLID DESICCANT DEHUMIDIFICATION air-conditioning system TROPICAL Humid CLIMATE
下载PDF
Modelling, Transient Simulation and Economic Analysis of Solar Thermal Based Air Conditioning System in Gujarat
7
作者 Ganesh Utham Sagarkumar M. Agravat +1 位作者 Bela Jani Jignasha Bhutka 《Smart Grid and Renewable Energy》 2016年第8期233-246,共14页
Commercial building sector accounts for 8% of the total electricity consumption in India. Cooling activities (HVAC) in commercial buildings consume 55% of the total energy utilized. Consequently, CO<sub>2</su... Commercial building sector accounts for 8% of the total electricity consumption in India. Cooling activities (HVAC) in commercial buildings consume 55% of the total energy utilized. Consequently, CO<sub>2</sub> emissions from conventional buildings in India were estimated to be 98 metric tonnes of CO<sub>2</sub> per million ft<sup>2</sup> in 2014. Solar thermal air conditioning can be the solution to these demands and can contribute to about 15% to 20% of India’s total oil consumption thereby reducing the dependence on fossil fuels. Hence, the main objective of the work is to model and simulate a solar absorption cooling system for GERMI office building located in Gandhinagar, Gujarat, India, using the transient simulation software ‘TRNSYS’. Cooling load estimation and comfort conditions required for the building were determined based on ASHRAE standards. Evacuated tube collectors were selected because of its market availability, ease of manufacturing and proven technology. Single effect absorption chiller was used because of its commercial availability. The effects of storage tank volume, collector area and collector slope were also investigated for parametric optimization. The results of the simulation and parametric analysis are analyzed and presented in the paper. 展开更多
关键词 Solar air conditioning Evacuated Tube Collectors (ETC) TRNSYS Simulation Single Effect Absorption Chiller Parametric Analysis INDIA
下载PDF
Metal hydride work pair development and its application on automobile air conditioning systems
8
作者 QIN Feng CHEN Jiang-ping +1 位作者 ZHANG Wen-feng CHEN Zhi-jiu 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2007年第2期197-204,共8页
关键词 金属氢化物 空气调节系统 氢能 制冷工程
下载PDF
Load Management Scheme Using Air Conditioning Electric Power Consumption and Photovoltaic Power System Generation
9
作者 Zvonimir Klaic Damir Sljivac Kresimir Fekete Zorislav Kraus 《Journal of Energy and Power Engineering》 2014年第11期1926-1932,共7页
关键词 太阳能光伏发电系统 电力消耗 空调系统 负载管理 配电网络 测量算法 师资队伍建设 电力生产
下载PDF
An approach for simulating the air brake system of long freight trains based on fluid dynamics 被引量:1
10
作者 Xin Ge Qinghua Chen +2 位作者 Liang Ling Wanming Zhai Kaiyun Wang 《Railway Engineering Science》 2023年第2期122-134,共13页
Air brake systems are critical equipment for railway trains, which affects the running safety of the trains significantly. To study air braking characteristics of long freight trains, an approach for simulating air br... Air brake systems are critical equipment for railway trains, which affects the running safety of the trains significantly. To study air braking characteristics of long freight trains, an approach for simulating air brake systems based on fuid dynamics theory was proposed. The structures and working mechanisms of locomotive and wagon air brakes are introduced, and mathematical models of the pipes, brake valves, reservoirs or chambers, cylinders, etc., are presented.Besides, the dynamic motions of parts in the main valve are considered. The simulation model of the whole air brake system is then formulated, and the solving method based on the finite-difference method is used. New efficient pipe boundary conditions without iterations are developed for brake pipes and branch pipes, which can achieve higher computational efficiency. The proposed approach for simulating the air brake system is validated by comparing with published measured data. Simulation results of different train formations indicate that models that consider the dynamic behavior of brake pipes are recommended for predicting the characteristics of long trains under service braking conditions. 展开更多
关键词 air brake system Fluid dynamics Railway train Boundary condition SIMULATION
下载PDF
Experimental Investigation on Local Air Age and Air Distribution of Stratum Ventilation 被引量:2
11
作者 WANG Feng-hao,LI Yuan-bin,LIU Xiao-dong,WANG Xin-ke(School of Human Settlements and Civil Engineering,Xi’an Jiaotong University,Xi’an,Shaanxi 710049,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期35-39,共5页
Because of the multiple problems on high energy consumption and unbalanced thermal comfort caused by the traditional ventilation system,a new concept of ventilation-stratum ventilation has been proposed,which sends th... Because of the multiple problems on high energy consumption and unbalanced thermal comfort caused by the traditional ventilation system,a new concept of ventilation-stratum ventilation has been proposed,which sends the fresh air to the breathing zone directly.In this paper,the local air distributions of the displacement ventilation and the stratum ventilation in a model office were measured.The air ages in the breathing zone for the displacement ventilation and stratum ventilation were compared with the tracer gas concentration decay method.The decay curves of tracer gas concentration for these two ventilation systems in the breathing zone were obtained,and the air ages were calculated.The experimental results show that the stratum ventilation system can offer lower air age for four mechanically ventilated cases in the breathing zone,and it can also provide better thermal comfort,which renews the air of breathing zone more quickly and reduces the energy consumption in some degree.The experimental investigation provides a theoretical basis for the application of stratum ventilation system. 展开更多
关键词 ventilation air QUALITY air age DISTRIBUTION
下载PDF
Closed-loop bulk air conditioning: A renewable energy-based system for deep mines in arctic regions 被引量:3
12
作者 Ali Fahrettin Kuyuk Seyed Ali Ghoreishi-Madiseh Faramarz P.Hassani 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2020年第4期511-516,共6页
With depletion of shallow deposits,the number of underground mines expected to reach more than 3 km depth during their lifetime is growing.Although surface cooling plants are mostly effective in mine airconditioning,u... With depletion of shallow deposits,the number of underground mines expected to reach more than 3 km depth during their lifetime is growing.Although surface cooling plants are mostly effective in mine airconditioning,usually secondary cooling units are needed below 2 kmdepth.This need emerges due to the elevated thermal impacts caused by auto-compression of mine air as well as heat emissions from strata and mine machinery.As a result,in cold climates,like Canada,ultra-deep mines need their secondary underground cooling plants running year-round while the intake air must be heated to protect the sensitive machinery and liners from freezing during the winter season.To cool mine air,horizontal bulk-airconditioners with direct spray cooling systems are commonly used due to their high performance.Conventionally,sprayed water in bulk-air-coolers are mechanically circulated and refrigerated in coupled refrigeration plants.This set up can be transformed to a natural cooling/heating process by resurfacing the warm underground bulk-air-cooler spray water for mine air heating on the surface and re-sinking the chilled water for cooling in the underground bulk air coolers.This could significantly cut-down the fossil-fuel consumption in burners for mine air pre-conditioning and refrigeration cost when applicable.This paper presents an anonymous real-life example to study the feasibility of the proposed idea for an ultra-deep Canadian mine. 展开更多
关键词 Energy recovery Renewable energy Mine energy systems Underground cooling Mine air preconditioning ventilation HVAC Mine air heating
下载PDF
Air-condition process for scalable fabrication of CdS/ZnS 1D/2D heterojunctions toward efficient and stable photocatalytic hydrogen production
13
作者 Dongdong Zhang Jie Teng +7 位作者 Hongli Yang Zhi Fang Kai Song Lin Wang Huilin Hou Xianlu Lu Chris RBowen Weiyou Yang 《Carbon Energy》 SCIE CSCD 2023年第7期1-14,共14页
We report the scalable fabrication of CdS/ZnS 1D/2D heterojunctions under ambient air conditions(i.e.,room temperature and atmospheric pressure)in which ZnS nanoparticles are anchored on the surface of CdS nanosheets.... We report the scalable fabrication of CdS/ZnS 1D/2D heterojunctions under ambient air conditions(i.e.,room temperature and atmospheric pressure)in which ZnS nanoparticles are anchored on the surface of CdS nanosheets.The as-formed heterojunctions exhibit a significantly enhanced photocatalytic H_(2) evolution rate of 14.02 mmol h^(-1) g^(-1) when irradiated with visible light,which is~10 and 85 times higher than those of pristine CdS nanosheets and CdS nanoparticles,respectively,and superior to most of the CdS-based photocatalysts reported to date.Furthermore,they provide robust photocatalytic performance with demonstratable stability over 58 h,indicating their potential for practical applications.The formation of 1D/2D heterojunctions not only provides improved exposed active sites that respond to illumination but also provides a rapid pathway to generate photogenerated carriers for efficient separation and transfer through the matrix of single-crystalline CdS nanosheets.In addition,first-principles simulations demonstrate that the existence of rich Zn vacancies increases the energy level of the ZnS valence band maximum to construct type-II and Z-scheme mixed heterojunctions,which plays a critical role in suppressing the recombination of carriers with limited photocorrosion of CdS to enhance photocatalytic behavior. 展开更多
关键词 air condition CDS HETEROJUNCTIONS photocatalytic hydrogen production ZNS
下载PDF
Localized Theoretical Analysis of Thermal Performance of Individually Finned Heat Pipe Heat Exchanger for Air Conditioning with Freon R404A as Working Fluid
14
作者 Élcio Nogueira 《Journal of Materials Science and Chemical Engineering》 2023年第8期61-85,共17页
This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat... This work contributes to the improvement of energy-saving in air conditioning systems. The objective is to apply the thermal efficiency of heat exchangers for localized determination of the thermal performance of heat exchangers with individually finned heat pipes. The fundamental parameters used for performance analysis were the number of fins per heat pipe, the number of heat pipes, the inlet temperatures, and the flow rates of hot and cold fluids. The heat exchanger under analysis uses Freon 404A as a working fluid in an air conditioning system for cooling in the Evaporator and energy recovery in the Condenser. The theoretical model is localized and applied individually to the Evaporator, Condenser, and heat exchanger regions. The results obtained through the simulation are compared with experimental results that use a global approach for the heat exchanger. The thermal quantities obtained through the theoretical model in the mentioned regions are air velocity, Nusselt number, thermal effectiveness, heat transfer rate, and outlet temperature. The comparisons made with global experimental results are in excellent agreement, demonstrating that the localized theoretical approach developed is consistent and can be used as a comprehensive analysis tool for heat exchangers using heat pipes. 展开更多
关键词 Individually Finned Heat Pipe Heat Exchanger Thermal Efficiency Thermal Effectiveness air conditioning Freon R404A
下载PDF
Causes of Odor in Kitchens,Bathrooms,and Toilets of Multi-story Residential Apartments with Natural Ventilation
15
作者 Alex A.Volinsky 《Journal of Civil Engineering and Architecture》 2023年第3期135-138,共4页
The causes of an offensive odor in the kitchens,bathrooms,and toilets of residential apartments in multi-story buildings with natural ventilation in Tomsk,Russia,are discussed in this paper.This problem exists in othe... The causes of an offensive odor in the kitchens,bathrooms,and toilets of residential apartments in multi-story buildings with natural ventilation in Tomsk,Russia,are discussed in this paper.This problem exists in other cities and countries.Wall electric fans can be installed in ventilation grills in kitchens,bathrooms,and toilets of apartments in multi-story residential buildings.Typically,these fans turn on with the light in the bathroom or toilet,so the problem is periodic.Forced airflow from a fan in one apartment disrupts the natural outflow of air in the ventilation system of a residential building designed and built according to building codes and regulations and can cause an unpleasant smell in neighboring apartments.In many cases,it is difficult to determine which apartments have fans and force the neighbors to remove them.Locally,on the scale of one apartment,the problem is solved by installing an air check valve in the ventilation grill,which will block the nuisance airflow from the ventilation system into the bathroom.Globally,the problem is solved by modification and subsequent compliance with building codes and regulations,the implementation of which is controlled by local authorities. 展开更多
关键词 ventilation ventilation fan sewage gas check air valve health safety public health
下载PDF
Modelling of a Two-Phase Thermosyphon Loop for Passive Air-Conditioning of a House in Hot and Dry Climate Countries 被引量:1
16
作者 Abdoulaye 1 Diallo Xavier Chesneau +1 位作者 Idrissa Diaby Djanfar El-Maktoume 《Energy and Power Engineering》 2021年第6期243-260,共18页
The two-phase thermosyphon loop is an efficient solution for space cooling. This paper presents the simulation results of numerical studies on the heat transfer and thermal performance of a two-phase thermosiphon loop... The two-phase thermosyphon loop is an efficient solution for space cooling. This paper presents the simulation results of numerical studies on the heat transfer and thermal performance of a two-phase thermosiphon loop for passive air-conditioning of a house. The fluid considered in this study is methanol, which is compatible with copper and is environmentally friendly. These numerical results show that the temperature at the evaporator wall drops from 23<span style="color:#111111;font-family:Roboto, sans-serif;font-size:16px;white-space:normal;background-color:#FFFFFF;">°</span>C to 13<span style="color:#111111;font-family:Roboto, sans-serif;font-size:16px;white-space:normal;background-color:#FFFFFF;">°</span>C and increases at the condenser. The solar flux density has a strong influence on the condenser temperature. The mass flow rates and masses at the evaporator and condenser increase with temperature. The variation of evaporating and condensing temperature affects the performance of the system. For a constant evaporating and condensing temperature of 2<span style="color:#111111;font-family:Roboto, sans-serif;font-size:16px;white-space:normal;background-color:#FFFFFF;">°</span>C and 29<span style="color:#111111;font-family:Roboto, sans-serif;font-size:16px;white-space:normal;background-color:#FFFFFF;">°</span>C, the COP is 0.77 and 0.84 respectively. With these results, the use of the two-phase thermosyphon loop in air conditioning is possible to obtain a thermal comfort of the occupants acceptable by the standards but with a large exchange surface of the evaporator. 展开更多
关键词 Two-Phase Thermosiphon Loop MODELLING Passive air conditioning Thermal Performance
下载PDF
Effect of Two Kinds of Similarity Factors on Principal Component Analysis Fault Detection in Air Conditioning Systems 被引量:2
17
作者 杨学宾 何如如 +1 位作者 王吉 罗雯军 《Journal of Donghua University(English Edition)》 CAS 2021年第3期245-251,共7页
Screening similar historical fault-free candidate data would greatly affect the effectiveness of fault detection results based on principal component analysis(PCA).In order to find out the candidate data,this study co... Screening similar historical fault-free candidate data would greatly affect the effectiveness of fault detection results based on principal component analysis(PCA).In order to find out the candidate data,this study compares unweighted and weighted similarity factors(SFs),which measure the similarity of the principal component subspace corresponding to the first k main components of two datasets.The fault detection employs the principal component subspace corresponding to the current measured data and the historical fault-free data.From the historical fault-free database,the load parameters are employed to locate the candidate data similar to the current operating data.Fault detection method for air conditioning systems is based on principal component.The results show that the weighted principal component SF can improve the effects of the fault-free detection and the fault detection.Compared with the unweighted SF,the average fault-free detection rate of the weighted SF is 17.33%higher than that of the unweighted,and the average fault detection rate is 7.51%higher than unweighted. 展开更多
关键词 similarity factor(SF) fault detection principal component analysis(PCA) historical candidate data air conditioning system
下载PDF
Influence of Three Sizes of Sliding Windows on Principle Component Analysis Fault Detection of Air Conditioning Systems 被引量:1
18
作者 杨学宾 马艳云 +2 位作者 何如如 王吉 罗雯军 《Journal of Donghua University(English Edition)》 CAS 2022年第1期72-78,共7页
Principal component analysis(PCA)has been already employed for fault detection of air conditioning systems.The sliding window,which is composed of some parameters satisfying with thermal load balance,can select the ta... Principal component analysis(PCA)has been already employed for fault detection of air conditioning systems.The sliding window,which is composed of some parameters satisfying with thermal load balance,can select the target historical fault-free reference data as the template which is similar to the current snapshot data.The size of sliding window is usually given according to empirical values,while the influence of different sizes of sliding windows on fault detection of an air conditioning system is not further studied.The air conditioning system is a dynamic response process,and the operating parameters change with the change of the load,while the response of the controller is delayed.In a variable air volume(VAV)air conditioning system controlled by the total air volume method,in order to ensure sufficient response time,30 data points are selected first,and then their multiples are selected.Three different sizes of sliding windows with 30,60 and 90 data points are applied to compare the fault detection effect in this paper.The results show that if the size of the sliding window is 60 data points,the average fault-free detection ratio is 80.17%in fault-free testing days,and the average fault detection ratio is 88.47%in faulty testing days. 展开更多
关键词 sliding window principal component analysis(PCA) fault detection sensitivity analysis air conditioning system
下载PDF
Practical Mitigation Strategies for Countering the Spread of Aerosolized COVID-19 Virus (SARS-CoV-2) Using Ventilation and HEPA Air Purifiers: A Literature Review 被引量:1
19
作者 Panayiotis Polyzois Shirley Thompson 《Journal of Geoscience and Environment Protection》 2021年第9期166-197,共32页
This paper assesses, through an extensive literature review, the use of ventilation and High-Efficiency Particulate Air (HEPA) purifiers as practical mitigation strategies for reducing the spread of aerosolized COVID-... This paper assesses, through an extensive literature review, the use of ventilation and High-Efficiency Particulate Air (HEPA) purifiers as practical mitigation strategies for reducing the spread of aerosolized COVID-19<sup>1</sup> virus. HEPA is a well-defined standard by the U.S. Department of Energy for filters. The focus of the literature review was on indoor air quality (IAQ) and COVID-19, with a particular emphasis on classroom settings. The start of the review, January 2020, was chosen to coincide with the first cases of COVID-19 in North America. Although children under the age of 12 are currently not yet vaccinated, there is mounting pressure for a return to normal by the start of the new school year, 2021. Also, many classrooms lack pre-installed mechanical ventilation systems (<a href="#ref79">Olsiewski et al., 2021</a>);therefore, mitigation in classrooms often falls solely in the hands of teachers and students. Research shows that ventilation and air purification are essential tools to counter aerosolized transmission (<5 μm) of the COVID-19 virus. According to <a href="#ref25">Curtius et al. (2020)</a>, the inhaled dose of particles containing virus RNA is six times lower when using air purifiers with an ACH (air changes per hour) of 5.7. However, ventilation and air purifiers are not replacements for masks, which remain vital for countering droplet (>5 μm) transmission. In addition, occupancy (i.e., number and proximity of people present in a given area) and group activity levels (e.g., talking, shouting, singing) play a critical role in viral transmission. Although natural ventilation by opening windows can be an essential strategy to help counter the spread of the virus, the level of ventilation offered by opening windows is largely uncontrollable as it is subject to weather <span style="font-family:Verdana;">conditions and building design. One must also consider the energy implications (i.e., loss of heat) that this strategy carries. Scientific evidence shows that varying levels of continuous and/or intermittent ventilation, either mechanical or natural, combined with the use of HEPA air purifiers, can provide a higher degree of protection than window access alone (<a href="#ref25">Curtius et al., 2020</a>). Systematic deployment of a hybrid mitigation strategy incorporating both ventilation and HEPA air purification in schools, offices, or other facilities offers a practical way to establish a safe re-opening of society in Canada.</span> 展开更多
关键词 COVID-19 SAS-CoV-2 Aerosolized ventilation HEPA air Purifier(s)
下载PDF
Numerical Analysis on Ventilating and Air Conditioning Scheme of Shenyang Subway Station 被引量:1
20
作者 李伟 那艳玲 《Transactions of Tianjin University》 EI CAS 2007年第2期147-151,共5页
Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and opera... Different cities have different climate conditions and outdoor temperature and humidity, so the scheme of an environment control in subway should be analyzed by considering objective conditions, project cost and operating status. In this paper, a physical and mathematical model is built according to the design of Shenyang subway (line 1), the boundary conditions of the model are defined by the design and experiments, the numerical analysis of ventilating scheme and air conditioning scheme is introduced individually, and the temperature field and air flow field of the two schemes are compared, so that the feasibility of using a ventilating scheme in subway of northeast cities is discussed. Considering comfort and economy, it can be concluded that mechanical ventilation is feasible in subway of northeast cities because the air temperature there is not very high in summer. 展开更多
关键词 沈阳 地铁车站 通风换气 空气调节方案 温度场 气流场
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部