期刊文献+
共找到3,156篇文章
< 1 2 158 >
每页显示 20 50 100
Accuracy assessment of global vertical displacement loading tide models for the equatorial and Indian Ocean
1
作者 Xiaoqing Xu Haidong Pan +1 位作者 Fei Teng Zexun Wei 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2024年第9期11-25,共15页
The three-dimensional displacements caused by ocean loading effects are significant enough to impact spatial geodetic measurements on sub-daily or longer timescales,particularly in the vertical direction.Currently,mos... The three-dimensional displacements caused by ocean loading effects are significant enough to impact spatial geodetic measurements on sub-daily or longer timescales,particularly in the vertical direction.Currently,most tide models incorporate the distribution of vertical displacement loading tides;however,their accuracy has not been assessed for the equatorial and Indian Ocean regions.Global Positioning System(GPS)observations provide high-precision data on sea-level changes,enabling the assessment of the accuracy and reliability of vertical displacement tide models.However,because the tidal period of the K_(2) constituent is almost identical to the orbital period of GPS constellations,the estimation of the K_(2) tidal constituent from GPS observations is not satisfactory.In this study,the principle of smoothness is employed to correct the systematic error in K_(2) estimates in GPS observations through quadratic fitting.Using the adjusted harmonic constants from 31 GPS stations for the equatorial and Indian Ocean,the accuracy of eight major constituents from five global vertical displacement tide models(FES2014,EOT11a,GOT4.10c,GOT4.8,and NAO.99b)is evaluated for the equatorial and Indian Ocean.The results indicate that the EOT11a and FES2014 models exhibit higher accuracy in the vertical displacement tide models for the equatorial and Indian Ocean,with root sum squares errors of 2.29 mm and 2.34 mm,res-pectively.Furthermore,a brief analysis of the vertical displacement tide distribution characteristics of the eight major constituents for the equatorial and Indian Ocean was conducted using the EOT11a model. 展开更多
关键词 accuracy assessment vertical displacement loading tide models tidal admittance equatorial and Indian Ocean GPS constellation
下载PDF
Longitudinal vibration characteristics of a tapered pipe pile considering the vertical support of surrounding soil and construction disturbance
2
作者 Li Zhenya Pan Yunchao +2 位作者 He Xianbin Lv Chong Mohammad Towhid 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2024年第1期51-63,共13页
This research is concentrated on the longitudinal vibration of a tapered pipe pile considering the vertical support of the surrounding soil and construction disturbance.First,the pile-soil system is partitioned into f... This research is concentrated on the longitudinal vibration of a tapered pipe pile considering the vertical support of the surrounding soil and construction disturbance.First,the pile-soil system is partitioned into finite segments in the vertical direction and the Voigt model is applied to simulate the vertical support of the surrounding soil acting on the pile segment.The surrounding soil is divided into finite ring-shaped zones in the radial direction to consider the construction disturbance.Then,the shear complex stiffness at the pile-soil interface is derived by solving the dynamic equilibrium equation for the soil from the outermost to innermost zone.The displacement impedance at the top of an arbitrary pile segment is obtained by solving the dynamic equilibrium equation for the pile and is combined with the vertical support of the surrounding soil to derive the displacement impedance at the bottom of the upper adjacent segment.Further,the displacement impedance at the pile head is obtained based on the impedance function transfer technique.Finally,the reliability of the proposed solution is verified,followed by a sensitivity analysis concerning the coupling effect of the pile parameters,construction disturbance and the vertical support of the surrounding soil on the displacement impedance of the pile. 展开更多
关键词 tapered pipe pile longitudinal vibration vertical support of the surrounding soil construction disturbance displacement impedance
下载PDF
Meshless Method for Analysis of Permeable Breakwaters in the Proximity of A Vertical Wall 被引量:7
3
作者 Nadji CHIOUKH Karim OUAZZANE +2 位作者 Yal??n YüKSEL Benameur HAMOUDI Esin ?EVIK 《China Ocean Engineering》 SCIE EI CSCD 2019年第2期148-159,共12页
In the present work, the improved version of the meshless singular boundary method(ISBM) is developed for analyzing the performance of bottom standing submerged permeable breakwaters in regular normally incident waves... In the present work, the improved version of the meshless singular boundary method(ISBM) is developed for analyzing the performance of bottom standing submerged permeable breakwaters in regular normally incident waves and in the proximity of a vertical wall. Both single and dual prismatic breakwaters of rectangular and trapezoidal forms are examined. The physical problem is cast in terms of the Laplace equation governing an irrotational flow and incompressible fluid motion with appropriate mixed type boundary conditions, and solved numerically using the ISBM. To model the permeability of the breakwaters fully absorbing boundary conditions are assumed. Numerical results are presented in terms of hydrodynamic quantities of the reflection coefficients. These are firstly validated against the results of a multi-domain boundary element method(BEM) developed independently for a previous study. The agreement between the results of the two methods is excellent. The coefficients of reflection are then computed and discussed for a variety of structural conditions including the breakwaters height, width, spacing, and absorbing permeability. Effects of the proximity of the vertical plane wall are also investigated. The breakwater's width is found to have only marginal effects compared with its height. Permeability tends to decrease the minimum reflections. These coefficients show periodic variations with the spacing relative to the wavelength. Trapezoidal breakwaters are found to be more cost-effective than the rectangular breakwaters. Dual breakwater systems are confirmed to perform much better than single structures. 展开更多
关键词 MESHLESS improved SINGULAR boundary method REGULAR normal waves rectangular and trapezoidal BREAKWATERS permeability vertical wall reflection
下载PDF
Experimental Study on Bubble Pulse Features Under the Combined Action of Horizontal and Vertical Walls 被引量:5
4
作者 王诗平 初文华 张阿漫 《China Ocean Engineering》 SCIE EI CSCD 2014年第3期293-301,共9页
The pulse features of a bubble have a close connection with the boundary condition. When a bubble moves near a rigid wall, it will be attracted by the Bjerknes force of the wall, and a jet pointing at the wall will be... The pulse features of a bubble have a close connection with the boundary condition. When a bubble moves near a rigid wall, it will be attracted by the Bjerknes force of the wall, and a jet pointing at the wall will be generated. In real application, the bubble may move under the combined action of walls in different directions when it forms at the corner of a pipe or at the bottom of a dam. The motion of the bubble shows complex and nonlinear characteristics under these conditions. In order to investigate the bubble pulse features near complex walls, a horizontal wall and a vertical wall are put into the experimental water tank synchronously, and an electric circuit with 200 voltages is designed to generate discharge bubbles, and then experimental study on the bubble pulse features under the combined action of horizontal and vertical walls is carried out. The influences of the combined action of two walls on the bubble shape, pulse period, moving trace and inside jet are obtained by changing the distances from bubble center to the two walls. It aims at providing references for the relevant theoretical and numerical research. 展开更多
关键词 BUBBLE combined action horizontal and vertical walls experimental study
下载PDF
Experimental and numerical study of the effect of pulsatile flow on wall displacement oscillation in a flexible lateral aneurysm model 被引量:3
5
作者 L.Z.Mu X.Y.Li +5 位作者 Q.Z.Chi S.Q.Yang P.D.Zhang C.J.Ji Y.He G.Gao 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2019年第5期1120-1129,共10页
This study experimentally and numerically investigated the effect of pulsatile flow of different frequencies and outflow resistance on wall deformation in a lateral aneurysm.A method for constructing a flexible aneury... This study experimentally and numerically investigated the effect of pulsatile flow of different frequencies and outflow resistance on wall deformation in a lateral aneurysm.A method for constructing a flexible aneurysm model was developed,and a self-designed piston pump was used to provide the pulsatile flow conditions.A fluid-structure interaction simulation was applied for comparison with and analysis of experimental findings.The maximum wall displacement oscillation increased as the pulsation frequency and outflow resistance increased,especially at the aneurysm dome.There is an obvious circular motion of the vortex center accompanying the periodic inflow fluctuation,and the pressure at the aneurysm dome at peak flow increased as the pulsatile flow frequency and terminal flow resistance increased.These results could explain why abnormal blood flow with high frequency and high outflow resistance is one of the risk factors for aneurysm rupture. 展开更多
关键词 LATERAL ANEURYSM In VITRO experiment PULSATILE flow wall displacement OSCILLATION Fluid-structure interaction simulation
下载PDF
Estimation of earth pressure against retaining walls with different limited displacement modes based on elastic theory 被引量:1
6
作者 ZHANG Le DANG Fa-ning +3 位作者 WANG Xu DING Jiu-long GAO Jun ZHANG Yu 《Journal of Mountain Science》 SCIE CSCD 2022年第1期289-304,共16页
The earth pressure acting on retaining walls due to creep and consolidation is under limited equilibrium conditions(limited displacement). Linear elastic constitutive theory can be applied to determine earth pressure ... The earth pressure acting on retaining walls due to creep and consolidation is under limited equilibrium conditions(limited displacement). Linear elastic constitutive theory can be applied to determine earth pressure distribution along retaining walls under limited displacement condition. In addition,tangent modulus in Duncan-Chang nonlinear elastic model was introduced to reflect the variations of soil modulus with confining pressure, and boundary strains were derived from Rankine active earth pressure, Rankine passive earth pressure, static earth pressure and principal stress direction deflection.According to the above four boundary strains, earth pressure on retaining walls was divided into five state zones. By comparing the calculation results obtained from the equations proposed in this paper with those of experimental tests, the following conclusions can be drawn: earth pressure distribution was always nonlinear along retaining walls for translation displacement(T mode), rotation displacement around wall base(RB mode), and translation + rotation displacement around wall base(RBT mode). Also,calculated earth pressure distributions along with the depth of wall were found to be consistent with measured values under three displacement modes.Additionally, a parametric study was carried out to evaluate the effects of internal friction angle and backfill soil cohesion on earth pressure. It could be seen from the above series of studies that the earth pressure equations derived in this work could be well applied in practical engineering in designing retaining walls. 展开更多
关键词 Linear elasticity Limited earth pressure Translation displacement Rotation displacement around wall base Rotation displacement Earth pressure state zone
下载PDF
Theoretical analysis on the deformation characteristics of coal wall in a longwall top coal caving face 被引量:5
7
作者 Bai Qingsheng Tu Shihao +1 位作者 Li Zhaoxin Tu Hongsheng 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2015年第2期199-204,共6页
Against the background of analyzing coal wall stability in 14101 fully mechanized longwall top coal caving face in Majialiang coal mine,based on the torque equilibrium of the coal wall,shield support and the roof stra... Against the background of analyzing coal wall stability in 14101 fully mechanized longwall top coal caving face in Majialiang coal mine,based on the torque equilibrium of the coal wall,shield support and the roof strata,an elastic mechanics model was established to calculate the stress applied on the coal wall.The displacement method was used to obtain the stress and deformation distributions of the coal wall.This study also researched the influence of support resistance,protective pressure to the coal wall,fracture position of the main roof and mining height on the coal wall deformation.The following conclusions are drawn:(1) The shorter the distance from the longwall face,the greater the vertical compressive stress and horizontal tensile stress borne by the coal wall.The coal wall is prone to failure in the form of compressive-shear and tension;(2) With increasing support resistance,the revolution angle of the main roof decreases linearly.As the support resistance and protective force supplied by the face guard increases,the maximum deformation of the coal wall decreases linearly;(3) As the face approaches the fracture position of the main roof,coal wall horizontal deformation increases significantly,and the coal wall is prone to instability;and(4) The best mining height of 14101 longwall face is 3.0 m. 展开更多
关键词 Longwall top coal caving face Coal wall deformation Torque equilibrium displacement method Parametric analysis
下载PDF
Effects of hanging wall and forward directivity in the 1999 Chi-Chi earthquake on inelastic displacement response of structures
8
作者 李爽 谢礼立 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2007年第1期77-84,共8页
The characteristics of the inelastic response of structures affected by hanging wall and forward directivity in the 1999 Chi-Chi earthquake are investigated. Inelastic displacement ratios (IDRs) for ground motions i... The characteristics of the inelastic response of structures affected by hanging wall and forward directivity in the 1999 Chi-Chi earthquake are investigated. Inelastic displacement ratios (IDRs) for ground motions impacted by these nearfield effects are evaluated and comprehensively compared to far-field ground motions. In addition, the inelastic displacement responses to hanging wall and footwall ground motions are compared. It is concluded that the inelastic displacement response is significantly affected in the short period range by hanging wall and in the long period range by footwall. Although high peak ground acceleration was observed at hanging wall stations, the IDRs for structures on hanging wall sites are only larger than footwall sites in the very long period range. Forward directivity effects result in larger IDRs for periods longer than about 0.5s. Adopting statistical relationships for IDRs established using far-field ground motions may lead to either overestimation or underestimation in the seismic evaluation of existing structures located in near-field regions, depending on their fundamental vibration periods. 展开更多
关键词 NEAR-FIELD FAR-FIELD hanging wall footwall forward directivity inelastic displacement performance evaluation Chi-Chi earthquake
下载PDF
A Visible Light Imaging System for the Estimation of Plasma Vertical Displacement in J-TEXT
9
作者 朱孟周 庄革 +4 位作者 王之江 丁永华 高丽 胡希伟 潘垣 《Plasma Science and Technology》 SCIE EI CAS CSCD 2010年第6期641-645,共5页
A wide-viewing-angle visible light imaging system (VLIS) was mounted on the Joint Texas Experimental Tokamak (J-TEXT) to monitor the discharge process. It is proposed that by using the film data recorded the plasm... A wide-viewing-angle visible light imaging system (VLIS) was mounted on the Joint Texas Experimental Tokamak (J-TEXT) to monitor the discharge process. It is proposed that by using the film data recorded the plasma vertical displacement can be estimated. In this paper installation and operation of the VLIS are presented in detailed. The estimated result is further compared with that measured by using an array of magnetic pickup coils. Their consistency verifies that the estimation of the plasma vertical displacement in J-TEXT by using the imaging data is promising. 展开更多
关键词 visible light imaging vertical displacement J-TEXT
下载PDF
The Vertical Deformation and Horizontal Displacement Fields,Movement, and Seismicity of the Island Arc Tectonics
10
作者 Luo Wei,Luo Zhuoli,and Chen ShangpingNational Center for Seismic Data and Informanon,SSB,Beijing 100045,China Center for Analysis and Prediction,SSB,Beijing 100036,China 《Earthquake Research in China》 1996年第3期25-36,共12页
In this work,the vertical deformation,horizontal displacement,and stress fields of arcuate tectonics are theoretically derived from the horizontal tectonic stress; then the characteristics of tectonic movement,seismic... In this work,the vertical deformation,horizontal displacement,and stress fields of arcuate tectonics are theoretically derived from the horizontal tectonic stress; then the characteristics of tectonic movement,seismicity,and focal mechanism of arcuate tectonics of the entire world are explained.It is pointed out that the island arc and other arcuate tectonics are gradually developed under the displacement and stress fields of the arcuate tectonics and that the under-thrusting action of the ocean plate is secondary.The distance formulas between the volcanic arc and the trench are suggested and also that theoretical results are consistent with actual data. 展开更多
关键词 Island arc ARCUATE TECTONICS vertical deformation FIELD Horizontal displacement FIELD TECTONIC MOVEMENT
下载PDF
Prevention and Control Measures for Vertical Spread of Fire along the External Wall of High-rise Buildings
11
作者 Jinliang Shao Leilei Shao 《Journal of World Architecture》 2019年第2期9-15,共7页
In the analysis and research of few cases on the characteristics of vertical"burning"and spreading of fire in high-rise buildings in China and overseas,the mechanism of vertical spreading of fire along exter... In the analysis and research of few cases on the characteristics of vertical"burning"and spreading of fire in high-rise buildings in China and overseas,the mechanism of vertical spreading of fire along external wall is caused by hot pressing and wind pressure existing in high-rise buildings.The use of external wall combustible materials and near-window combustible items resulted in the formation of high temperature pyrotechnics and the burning of the external wall.Besides,due to the lack of fire-fighting measurements in high-rise building,it is recommended that the external wall of the high-rise building should be equipped with vertical fire-proof partitioning and non-combustible materials by setting up an automatic fire-fighting water curtain system along the vertical section of the external wall and above the indoor window.Therefore,the automatic sprinkler can be set up to prevent the fire from spreading vertically along the external wall of the building effectively. 展开更多
关键词 HIGH-RISE Building vertical FIRE SPREAD External wall AUTOMATIC FIRE Extinguishing Water CURTAIN System AUTOMATIC Window Nozzle
下载PDF
Synergetic Effects of Runaway Electron and Vertical Instability on the Wall Damage on HL-2A Tokamak
12
作者 YANG Yinwei YUAN Baoshan YANG Qingwei ZHANG Yipo SONG Xianying LI Xu ZHENG Yinjia CAO Zeng 《Southwestern Institute of Physics Annual Report》 2005年第1期17-19,共3页
1 Generation of vertical instability Tokamak experiments show that the energy confinement time and performance are better, and the larger plasma current can be achieved for non-circular cross-sectional shape of plasma... 1 Generation of vertical instability Tokamak experiments show that the energy confinement time and performance are better, and the larger plasma current can be achieved for non-circular cross-sectional shape of plasma than circular cross-section. However, the external magnetic fields which are used to produce the non-circular cross sectional shape also cause the confined plasma to become unstable to small vertical displacement. In general, the ratio of elongation k is larger, the possibility of instability is more. In practice, this vertical displacement mode stabilized by feedback control system or other provided external radial magnetic field to balance out the plasma motion. Under some of situations the control system may be fail due to rapid growth rate of instability exceeding the ability of controlling. The plasma will then move vertically upwards or downwards depending upon the characteristics of instability and control failure. 展开更多
关键词 Runaway electron vertical displacement episode(VDE) Halo current
下载PDF
Effects of Prandtl and Jacob Numbers and Dimensionless Thermal Conductivity on Velocity Profiles in Media (Porous and Liquid)
13
作者 Momath Ndiaye Madialène Sene Goumbo Ndiaye 《Journal of Modern Physics》 2024年第10期1603-1614,共12页
In this present study, we analyzed the effects of Prandtl and Jacob numbers and dimensionless thermal conductivity on the velocity profiles in media (porous and liquid). The transfers in the porous medium and the liqu... In this present study, we analyzed the effects of Prandtl and Jacob numbers and dimensionless thermal conductivity on the velocity profiles in media (porous and liquid). The transfers in the porous medium and the liquid film are described respectively by the improved Wooding model and the classical boundary layer equations. The mesh of the digital domain is considered uniform in the transverse and longitudinal directions. The advection and diffusion terms are discretized with a back-centered and centered scheme respectively. The coupled systems of algebraic equations thus obtained are solved numerically using an iterative line-by-line relaxation method of the Gauss-Seidel type. The results show that the parameters relating to the thermal problem (the dimensionless thermal conductivity, the Prandtl (Pr) and Jacob (Ja) numbers) have no influence on the dimensionless speed, although the thermal and hydrodynamic problems are coupled. Via the heat balance equation. The results obtained show that the parameters relating to the thermal problem have no influence on the dimensionless speed, although the thermal and hydrodynamic problems are coupled via the heat balance equation. So, at first approximation with the chosen constants, we can solve the hydrodynamic problem independently of the thermal problem. 展开更多
关键词 CONDENSATION Implicit Finite Difference Thin Film Porous Material Model Wooding vertical wall
下载PDF
Effect of passive plates on vertical instability in the EAST tokamak 被引量:1
14
作者 刘广君 万宝年 +6 位作者 钱金平 孙有文 肖炳甲 沈飚 罗正平 戟翔 陈树亮 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第8期323-329,共7页
The effect of passive plates on vertical displacement control in the EAST tokamak is investigated by open loop experiments and numerical simulations based on a rigid displacement model. The experiments and simulations... The effect of passive plates on vertical displacement control in the EAST tokamak is investigated by open loop experiments and numerical simulations based on a rigid displacement model. The experiments and simulations indicate that the vertical instability growth rate is reduced by a factor of about 2 in the presence of the passive plates, where the adjacent segments are not connected to each other. The simulations also show that the vertical instability growth rate is reduced by a factor of about 10 if all adjacent segments on each passive plate loop are connected to each other. The operational window is greatly enlarged with the passive plates. 展开更多
关键词 passive plate vertical instability rigid displacement model
下载PDF
Seismic performance evaluation of steel frame-steel plate shear walls system based on the capacity spectrum method 被引量:3
15
作者 Jian-hua SHAO Qiang GU Yong-kang SHEN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第3期322-329,共8页
This paper presents some methods that the standard acceleration design response spectra derived from the present China code for seismic design of buildings are transformed into the seismic demand spectra, and that the... This paper presents some methods that the standard acceleration design response spectra derived from the present China code for seismic design of buildings are transformed into the seismic demand spectra, and that the base shear force-roof displacement curve of structure is converted to the capacity spectrum of an equivalent single-degree-of-freedom (SDOF) system. The capacity spectrum method (CSM) is programmed by means of MATLABT.0 computer language. A dual lateral force resisting system of 10-story steel frame-steel plate shear walls (SPSW) is designed according to the corresponding China design codes. The base shear force-roof displacement curve of structure subjected to the monotonic increasing lateral inverse triangular load is obtained by applying the equivalent strip model to stimulate SPSW and by using the finite element analysis software SAP2000 to make Pushover analysis. The seismic performance of this dual system subjected to three different conditions, i.e. the 8-intensity frequently occurred earthquake, fortification earthquake and seldom occurred earthquake, is evaluated by CSM program. The excessive safety of steel frame-SPSW system designed according to the present China design codes is pointed out and a new design method is suggested. 展开更多
关键词 Steel frame-steel plate shear walls (SPSW) system Capacity spectrum method (CSM) Seismic demand spectrum Base shear force-roof displacement Seismic performance evaluation
下载PDF
Formula of Overtopping Discharge of Vertical Seawall with A Form Similar to Solitary Wave Function 被引量:1
16
作者 LI Xiao-liang 《China Ocean Engineering》 SCIE EI CSCD 2022年第5期802-807,共6页
An empirical formula to predict overtopping discharge of vertical wall is presented,in which an expression similar to the solitary wave function is proposed to describe the rule of the influence of relative water dept... An empirical formula to predict overtopping discharge of vertical wall is presented,in which an expression similar to the solitary wave function is proposed to describe the rule of the influence of relative water depth.The formula is derived from performing an investigation to the well-known overtopping graphs of Goda,and for the sake of interest,the process of the derivation is detailed.To make clear the formula’s performance,relevant test datasets in the CLASH database are extracted to examine the error levels of the formula.As a result,an overall good agreement has been found between the predictions of the formula and the extracted datasets in a wide range outside the extreme shallow region,i.e.,the range of relative water depth smaller than 0.6,in which the water depth near the wall is so shallow that nearly all the incoming waves have been broken before reaching the wall. 展开更多
关键词 overtopping discharge formula vertical wall Goda graph
下载PDF
A Theoretical Study the Effect of Openings in Infill Wall Panels on the Behavior of Structures
17
作者 Umary Jamal 《Journal of Southeast University(English Edition)》 EI CAS 1998年第1期98-101,共4页
Two dimensional,reinforced concrete building frames built on raft foundation and having infill wall panels with openings in them are analysed using the direct stiffness method.Beams and columns are modelled by beam co... Two dimensional,reinforced concrete building frames built on raft foundation and having infill wall panels with openings in them are analysed using the direct stiffness method.Beams and columns are modelled by beam column elements.Wall panels are modelled by plane stress finite elements.The raft foundation is modelled by uniaxial finite elements.The soil is modelled as half space model.Openings in wall panels are introduced by using fictitious beams between real floor beams. A computer program is written to carry out the static analysis and do the necessary comparison to show the effect of openings on the structural behavior. 展开更多
关键词 infill wall panels OPENINGS direct stiffness method horizontal displacement STATIC SEISMIC
下载PDF
Investigation of Vegetation Resources on City Wall of the Ming Dynasty in Nanjing City and Ecological Evaluation of the City Wall
18
作者 WANG Xiaomei QIN Xiaoying +4 位作者 SHI Hao LIU Jingwen QIAN Haili WAN Li LIU Yalan 《Journal of Landscape Research》 2012年第11期37-39,42,共4页
Phyto-groups on 5 remained city wall sections of the Ming Dynasty in Nanjing City was investigated through on-the-spot survey,99 species of 93 genera,60 families were found,and species of Asteraceae and Poaceae accoun... Phyto-groups on 5 remained city wall sections of the Ming Dynasty in Nanjing City was investigated through on-the-spot survey,99 species of 93 genera,60 families were found,and species of Asteraceae and Poaceae accounted for the largest ratio.Plants on the city wall are characterized by strong drought resistance and precocity,their seeds can grow out of the wall cracks,and roots secrete acidoid and obtain nutrients from wall bricks.Plants on different wall sections are different,and human interventions influence phyto-groups on the city wall greatly.On this basis,it was concluded that plants had negative influence on city wall,especially plant roots destroyed the wall seriously.Corresponding researches were carried out and prevention suggestions proposed to provide scientific support for the protection of ancient city walls in Nanjing City. 展开更多
关键词 City wall of the Ming DYNASTY in NANJING wall PLANTS Protection of ANCIENT buildings vertical GREENING
下载PDF
Mathematical Modelling of Mass Transfer and Free Convection Current Effects on Unsteady Viscous Flow with Ramped Wall Temperature
19
作者 Marneni Narahari Osman Anwar Bég Swapan Kumar Ghosh 《World Journal of Mechanics》 2011年第4期176-184,共9页
An exact analysis of the flow of an incompressible viscous fluid past an infinite vertical plate is conducted taking into account the presence of foreign mass or constant mass flux and ramped wall temperature. The dim... An exact analysis of the flow of an incompressible viscous fluid past an infinite vertical plate is conducted taking into account the presence of foreign mass or constant mass flux and ramped wall temperature. The dimensionless governing coupled linear partial differential equations are solved using the Laplace transform technique. Two different solutions for the fluid velocity are obtained–one valid for the fluids of Schmidt numbers different from unity, and the other for which the Schmidt number is unity. The effects of Prandtl number (Pr), Schmidt number (Sc), time (t) and mass to thermal buoyancy ratio parameter (N) for both aiding and opposing buoyancy effects on the velocity and skin-friction are studied. Also, the heat and mass transfer effects on the flow near a ramped temperature plate have been compared with the flow near a plate with constant temperature. 展开更多
关键词 Natural CONVECTION vertical PLATE Ramped wall Temperature Heat and Mass Transfer
下载PDF
Study on the Phenomenon of Geomagnetic Low-value Displacement before Moderately Strong Earthquakes in Gansu
20
作者 Zhang Suping Feng Jiangang 《Earthquake Research in China》 2009年第2期200-209,共10页
This paper analyzes the distribution characteristics of geomagnetic low-value displacement in Gansu and its adjacent areas from 1995 to 2003 on the basis of the data of the daily amplitude minimum value time of the ge... This paper analyzes the distribution characteristics of geomagnetic low-value displacement in Gansu and its adjacent areas from 1995 to 2003 on the basis of the data of the daily amplitude minimum value time of the geomagnetic vertical component. It is shown that in addition to the changing rules of geomagnetic low-value displacement itself, there is a better correlation between geomagnetic low-value displacement and the occurrence of moderately strong earthquakes. There appeared to be geomagnetic low-value displacement before the moderately strong earthquakes in Gansu in the 9 years from 1995 to 2003. This result indicates that geomagnetic low-value displacement is of instructive significance for earthquake prediction to some extents. 展开更多
关键词 GANSU Geomagnetic vertical component Geomagnetic low-value displacement Moderately strong earthquake
下载PDF
上一页 1 2 158 下一页 到第
使用帮助 返回顶部