For the partial discharge test of electrical equipment with large capacitance,the use of lowfrequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply.Ho...For the partial discharge test of electrical equipment with large capacitance,the use of lowfrequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply.However,the validity of PD test under low frequency voltage needs to be evaluated.In order to investigate the influence of voltage frequency on corona discharge in the air,the discharge test of the tip-plate electrode under the frequency from 50 to0.1 Hz is carried out based on the impulse current method.The results show that some of the main features of corona under low frequency do not change.The magnitude of discharge in a positive half cycle is obviously larger than that in a negative cycle.The magnitude of discharge and interval in positive cycle are random,while that in negative cycle are regular.With the decrease of frequency,the inception voltage increases.The variation trend of maximum and average magnitude and repetition rate of the discharge in positive and negative half cycle with the variation of voltage frequency and magnitude is demonstrated,with discussion and interpretation from the aspects of space charge transportation,effective discharge time and transition of discharge modes.There is an obvious difference in the phase resolved pattern of partial discharge and characteristic parameters of discharge patterns between power and low frequency.The experimental results can be the reference for mode identification of partial discharge under low frequency tests.The trend of the measured parameters with the variation of frequency provides more information about the insulation defect than traditional measurements under a single frequency(usually 50 Hz).Also it helps to understand the mechanism of corona discharge with an explanation of the characteristics under different frequencies.展开更多
To apply a quasi-cyclic low density parity check(QC-LDPC)to different scenarios,a data-stream driven pipelined macro instruction set and a reconfigurable processor architecture are proposed for the typical QC-LDPC alg...To apply a quasi-cyclic low density parity check(QC-LDPC)to different scenarios,a data-stream driven pipelined macro instruction set and a reconfigurable processor architecture are proposed for the typical QC-LDPC algorithm.The data-level parallelism is improved by instructions to dynamically configure the multi-core computing units.Simultaneously,an intelligent adjustment strategy based on a programmable wake-up controller(WuC)is designed so that the computing mode,operating voltage,and frequency of the QC-LDPC algorithm can be adjusted.This adjustment can improve the computing efficiency of the processor.The QC-LDPC processors are verified on the Xilinx ZCU102 field programmable gate array(FPGA)board and the computing efficiency is measured.The experimental results indicate that the QC-LDPC processor can support two encoding lengths of three typical QC-LDPC algorithms and 20 adaptive operating modes of operating voltage and frequency.The maximum efficiency can reach up to 12.18 Gbit/(s·W),which is more flexible than existing state-of-the-art processors for QC-LDPC.展开更多
The low frequency oscillation characteristics of East China Power Grid after commissioning of the first ultra-high voltage alternating current(UHVAC)project-the Huai-Hu UHVAC project are studied.Several low frequency ...The low frequency oscillation characteristics of East China Power Grid after commissioning of the first ultra-high voltage alternating current(UHVAC)project-the Huai-Hu UHVAC project are studied.Several low frequency oscillation cases occurred in East China Power Grid in the past few years are reviewed and summarized.Based on the analysis of the different typical operation modes,the main low frequency oscillation modes in East China Power Grid in the early stages of development of ultra-high voltage(UHV)are summarized,and the impacts of the significant power grid maintenance on low frequency oscillation characteristics are analyzed.Besides,the oscillation mode of UHV generators to East China Power Grid is researched,and the importance of the power system stabilizator(PSS)is emphasized.Furthermore,the comparative analysis between the time domain and the frequency domain is carried out,and the influences of the governing system on low frequency oscillation characteristics are revealed.Finally,both the focus and the direction of low frequency oscillation research are presented.展开更多
在星载甚低频(VLF)通信技术中,研究甚低频信号在电离层中的传输特性具有重要意义。现有的利用时域有限差分(FDTD)算法研究电离层传输特性大多基于高频脉冲信号,且传播模型相对粗略,计算存在一定误差。为此,建立了更为精确的电离层...在星载甚低频(VLF)通信技术中,研究甚低频信号在电离层中的传输特性具有重要意义。现有的利用时域有限差分(FDTD)算法研究电离层传输特性大多基于高频脉冲信号,且传播模型相对粗略,计算存在一定误差。为此,建立了更为精确的电离层各向异性传播模型,对常规的FDTD算法引入变步长因子,并用该算法对VLF波在电离层中的场强衰减进行了数值计算,研究了昼夜变化及频率对其传输特性的影响。仿真结果与卫星实测数据对比表明:与常规的FDTD算法以及全波分析方法相比,引入变步长因子的FDTD算法精度更高;在VLF频段,降低频率有利于电磁波穿透电离层,且白天的衰减明显大于夜间;VLF波在射入电离层并穿透D层时衰减严重(30-40 d B),约为F1层中衰减的3倍。展开更多
基金supported by the National Key R&D Program of China(2017YFB0902704)the Science and Technology Project of SGCC(GY71-15-048)
文摘For the partial discharge test of electrical equipment with large capacitance,the use of lowfrequency voltage instead of power frequency voltage can effectively reduce the capacity requirements of test power supply.However,the validity of PD test under low frequency voltage needs to be evaluated.In order to investigate the influence of voltage frequency on corona discharge in the air,the discharge test of the tip-plate electrode under the frequency from 50 to0.1 Hz is carried out based on the impulse current method.The results show that some of the main features of corona under low frequency do not change.The magnitude of discharge in a positive half cycle is obviously larger than that in a negative cycle.The magnitude of discharge and interval in positive cycle are random,while that in negative cycle are regular.With the decrease of frequency,the inception voltage increases.The variation trend of maximum and average magnitude and repetition rate of the discharge in positive and negative half cycle with the variation of voltage frequency and magnitude is demonstrated,with discussion and interpretation from the aspects of space charge transportation,effective discharge time and transition of discharge modes.There is an obvious difference in the phase resolved pattern of partial discharge and characteristic parameters of discharge patterns between power and low frequency.The experimental results can be the reference for mode identification of partial discharge under low frequency tests.The trend of the measured parameters with the variation of frequency provides more information about the insulation defect than traditional measurements under a single frequency(usually 50 Hz).Also it helps to understand the mechanism of corona discharge with an explanation of the characteristics under different frequencies.
基金the National Key Research and Development Program of China(2019YFB1803600)the Key Scientific Research Program of Shaanxi Provincial Department of Education(22JY059)the China Civil Aviation Airworthiness Center Open Foundation(SH2021111903)。
文摘To apply a quasi-cyclic low density parity check(QC-LDPC)to different scenarios,a data-stream driven pipelined macro instruction set and a reconfigurable processor architecture are proposed for the typical QC-LDPC algorithm.The data-level parallelism is improved by instructions to dynamically configure the multi-core computing units.Simultaneously,an intelligent adjustment strategy based on a programmable wake-up controller(WuC)is designed so that the computing mode,operating voltage,and frequency of the QC-LDPC algorithm can be adjusted.This adjustment can improve the computing efficiency of the processor.The QC-LDPC processors are verified on the Xilinx ZCU102 field programmable gate array(FPGA)board and the computing efficiency is measured.The experimental results indicate that the QC-LDPC processor can support two encoding lengths of three typical QC-LDPC algorithms and 20 adaptive operating modes of operating voltage and frequency.The maximum efficiency can reach up to 12.18 Gbit/(s·W),which is more flexible than existing state-of-the-art processors for QC-LDPC.
文摘The low frequency oscillation characteristics of East China Power Grid after commissioning of the first ultra-high voltage alternating current(UHVAC)project-the Huai-Hu UHVAC project are studied.Several low frequency oscillation cases occurred in East China Power Grid in the past few years are reviewed and summarized.Based on the analysis of the different typical operation modes,the main low frequency oscillation modes in East China Power Grid in the early stages of development of ultra-high voltage(UHV)are summarized,and the impacts of the significant power grid maintenance on low frequency oscillation characteristics are analyzed.Besides,the oscillation mode of UHV generators to East China Power Grid is researched,and the importance of the power system stabilizator(PSS)is emphasized.Furthermore,the comparative analysis between the time domain and the frequency domain is carried out,and the influences of the governing system on low frequency oscillation characteristics are revealed.Finally,both the focus and the direction of low frequency oscillation research are presented.
文摘在星载甚低频(VLF)通信技术中,研究甚低频信号在电离层中的传输特性具有重要意义。现有的利用时域有限差分(FDTD)算法研究电离层传输特性大多基于高频脉冲信号,且传播模型相对粗略,计算存在一定误差。为此,建立了更为精确的电离层各向异性传播模型,对常规的FDTD算法引入变步长因子,并用该算法对VLF波在电离层中的场强衰减进行了数值计算,研究了昼夜变化及频率对其传输特性的影响。仿真结果与卫星实测数据对比表明:与常规的FDTD算法以及全波分析方法相比,引入变步长因子的FDTD算法精度更高;在VLF频段,降低频率有利于电磁波穿透电离层,且白天的衰减明显大于夜间;VLF波在射入电离层并穿透D层时衰减严重(30-40 d B),约为F1层中衰减的3倍。