This paper presents an improved finite control set model predictive current control(FCS-MPCC)of a five-phase permanent magnet synchronous motor(PMSM).First,to avoid including all the 32 voltage vectors provided by a t...This paper presents an improved finite control set model predictive current control(FCS-MPCC)of a five-phase permanent magnet synchronous motor(PMSM).First,to avoid including all the 32 voltage vectors provided by a two-level five-phase inverter into the control set,virtual voltage vectors are adopted.As the third current harmonics can be much reduced by virtual voltage vectors automatically,the harmonic items in the cost function of conventional FCS-MPCC are not considered.Furthermore,an adaptive control set is proposed based on voltage prediction.Best control set with proper voltage vector amplitude corresponding to different rotor speed can be achieved by this method.Consequently,current ripples can be largely reduced and the system performs much better.At last,simulations are established to verify the steady and transient performance of the proposed FCS-MPCC,and experiments based on a 2 kW five-phase motor are carried out.The results have validated the performance improvement of the proposed control strategy.展开更多
在五相永磁同步电机(permanent-magnet synchronous motor,PMSM)中,有限集模型预测容错控制(finite control set model predictive fault tolerant control,FCS-MPFTC)存在计算量大、电流谐波含量高等问题。因此,该文提出一种简化FCS-MP...在五相永磁同步电机(permanent-magnet synchronous motor,PMSM)中,有限集模型预测容错控制(finite control set model predictive fault tolerant control,FCS-MPFTC)存在计算量大、电流谐波含量高等问题。因此,该文提出一种简化FCS-MPFTC来实现相开路和短路故障情况下的统一容错控制。首先,将模型预测电流控制的电流代价函数等效转化为电压代价函数,并采用无差拍方法通过电流模型计算出参考电压。然后,基于抑制三次谐波电流为0的原则合成虚拟电压矢量(virtual voltage vector,V^(3));通过重构V^(3)和扇区,以直接获得参考电压矢量对应的最优电压矢量。最后,对传统和简化FCS-MPFTC在开路和短路故障下进行对比实验。结果表明,所提策略能够有效减小故障后计算量、转矩脉动以及电流谐波含量。展开更多
针对电网电压不平衡下电流平衡及功率恒定问题,提出改进型光储虚拟同步发电机(virtual synchronous generator,VSG)控制策略,该策略通过引入虚拟阻抗技术和双二阶广义积分器(double second order generalized integrator,DSOGI)实现正...针对电网电压不平衡下电流平衡及功率恒定问题,提出改进型光储虚拟同步发电机(virtual synchronous generator,VSG)控制策略,该策略通过引入虚拟阻抗技术和双二阶广义积分器(double second order generalized integrator,DSOGI)实现正负序分量的有效分离,并基于瞬时功率理论优化电流和功率的协调控制,显著提高了系统在不平衡电网条件下的电流平衡性和功率稳定性。首先,构建基于电机瞬态模型的光伏储能VSG系统的数学模型,以深入理解和模拟VSG在实际电网中的动态行为。通过应用双二阶广义积分器技术,实现了正序与负序分量的有效分离,并基于瞬时功率理论和负序虚拟复阻抗技术,进一步实现电流和功率的协调控制,确保电流平衡及功率恒定。最后,利用MATLA/Simulink软件构建仿真模型,模拟光伏储能系统在不平衡电网状态下的运行情况,仿真结果表明所提控制策略显著提高了控制策略的精度和响应速度,可确保动态电网环境中的操作效率和可靠性。展开更多
This study focuses on a virtual synchronous machine(VSM) based on voltage source converters to mimic the behavior of synchronous machines(SMs) and improve the damping ratio of the power system. The VSM model is simpli...This study focuses on a virtual synchronous machine(VSM) based on voltage source converters to mimic the behavior of synchronous machines(SMs) and improve the damping ratio of the power system. The VSM model is simplified according to some assumptions(neglecting the speed variation and the stator transients) to allow for the possibility of dealing with low-frequency oscillation in large-scale systems with many VSMs. Furthermore, a virtual power system stabilizer(VPSS) structure is proposed and tuned using a method based on a linearized power system dynamic model. The linear and nonlinear analyses examine the stability of two modified versions of a 16-machine power system in which, in the first case, partial classical machines are replaced by VSMs, and in the second case, all SMs are replaced by VSMs. The simulation results of the case studies validate the efficiency of the proposed control strategy.展开更多
基金This work was supported in part by the National Natural Science Foundation of China under 61374125。
文摘This paper presents an improved finite control set model predictive current control(FCS-MPCC)of a five-phase permanent magnet synchronous motor(PMSM).First,to avoid including all the 32 voltage vectors provided by a two-level five-phase inverter into the control set,virtual voltage vectors are adopted.As the third current harmonics can be much reduced by virtual voltage vectors automatically,the harmonic items in the cost function of conventional FCS-MPCC are not considered.Furthermore,an adaptive control set is proposed based on voltage prediction.Best control set with proper voltage vector amplitude corresponding to different rotor speed can be achieved by this method.Consequently,current ripples can be largely reduced and the system performs much better.At last,simulations are established to verify the steady and transient performance of the proposed FCS-MPCC,and experiments based on a 2 kW five-phase motor are carried out.The results have validated the performance improvement of the proposed control strategy.
文摘在五相永磁同步电机(permanent-magnet synchronous motor,PMSM)中,有限集模型预测容错控制(finite control set model predictive fault tolerant control,FCS-MPFTC)存在计算量大、电流谐波含量高等问题。因此,该文提出一种简化FCS-MPFTC来实现相开路和短路故障情况下的统一容错控制。首先,将模型预测电流控制的电流代价函数等效转化为电压代价函数,并采用无差拍方法通过电流模型计算出参考电压。然后,基于抑制三次谐波电流为0的原则合成虚拟电压矢量(virtual voltage vector,V^(3));通过重构V^(3)和扇区,以直接获得参考电压矢量对应的最优电压矢量。最后,对传统和简化FCS-MPFTC在开路和短路故障下进行对比实验。结果表明,所提策略能够有效减小故障后计算量、转矩脉动以及电流谐波含量。
文摘针对电网电压不平衡下电流平衡及功率恒定问题,提出改进型光储虚拟同步发电机(virtual synchronous generator,VSG)控制策略,该策略通过引入虚拟阻抗技术和双二阶广义积分器(double second order generalized integrator,DSOGI)实现正负序分量的有效分离,并基于瞬时功率理论优化电流和功率的协调控制,显著提高了系统在不平衡电网条件下的电流平衡性和功率稳定性。首先,构建基于电机瞬态模型的光伏储能VSG系统的数学模型,以深入理解和模拟VSG在实际电网中的动态行为。通过应用双二阶广义积分器技术,实现了正序与负序分量的有效分离,并基于瞬时功率理论和负序虚拟复阻抗技术,进一步实现电流和功率的协调控制,确保电流平衡及功率恒定。最后,利用MATLA/Simulink软件构建仿真模型,模拟光伏储能系统在不平衡电网状态下的运行情况,仿真结果表明所提控制策略显著提高了控制策略的精度和响应速度,可确保动态电网环境中的操作效率和可靠性。
文摘This study focuses on a virtual synchronous machine(VSM) based on voltage source converters to mimic the behavior of synchronous machines(SMs) and improve the damping ratio of the power system. The VSM model is simplified according to some assumptions(neglecting the speed variation and the stator transients) to allow for the possibility of dealing with low-frequency oscillation in large-scale systems with many VSMs. Furthermore, a virtual power system stabilizer(VPSS) structure is proposed and tuned using a method based on a linearized power system dynamic model. The linear and nonlinear analyses examine the stability of two modified versions of a 16-machine power system in which, in the first case, partial classical machines are replaced by VSMs, and in the second case, all SMs are replaced by VSMs. The simulation results of the case studies validate the efficiency of the proposed control strategy.