Tension cables are easily prone to generating varied vibrations under the action of external loads, which adversely affects the safety of bridges. Therefore, it is necessary to take effective measures to suppress the ...Tension cables are easily prone to generating varied vibrations under the action of external loads, which adversely affects the safety of bridges. Therefore, it is necessary to take effective measures to suppress the vibrations of tension cables. Cable end dampers are widely used in vibration reduction for cable-stayed bridges due to their convenient installation and low costs. However, the previous studies on the tension cable-viscous damper systems mostly adopt the linear method, and the weakening effect of the flexibility of mounting brackets on the damper vibration reduction is not sufficiently taken into account. Therefore, this paper adopts the improved Kelvin model to conduct the derivation, solution, and parametric analysis of vibration equations for the stay cable-nonlinear viscous damper systems. The results of parametric analysis show that the maximum modal damping ratio that can be obtained by cables and the corresponding optimal damping coefficient of dampers are correlated with the damping nonlinear coefficient α, stiffness nonlinear coefficient β, vibration order n, installation position a/L, and stiffness coefficient μ, etc.;among them, n damping nonlinear coefficient α and stiffness nonlinear coefficient β are the key parameters that affect the parameter design of dampers, where damping nonlinear coefficient α mainly controls the optimal damping coefficient and stiffness nonlinear coefficient β mainly controls the maximum damping ratio. Based on the parametric analysis, the design principles of dampers and value requirements of key parameters under different vibration suppression objectives are presented.展开更多
Computational fluid dynamics(CFD)provides a powerful tool for investigating complicated fluid flows.This paper aims to study the applicability of CFD in the preliminary design of linear and nonlinear fluid viscous dam...Computational fluid dynamics(CFD)provides a powerful tool for investigating complicated fluid flows.This paper aims to study the applicability of CFD in the preliminary design of linear and nonlinear fluid viscous dampers.Two fluid viscous dampers were designed based on CFD models.The first device was a linear viscous damper with straight orifices.The second was a nonlinear viscous damper containing a one-way pressure-responsive valve inside its orifices.Both dampers were detailed based on CFD simulations,and their internal fluid flows were investigated.Full-scale specimens of both dampers were manufactured and tested under dynamic loads.According to the tests results,both dampers demonstrate stable cyclic behaviors,and as expected,the nonlinear damper generally tends to dissipate more energy compared to its linear counterpart.Good compatibility was achieved between the experimentally measured damper force-velocity curves and those estimated from CFD analyses.Using a thermography camera,a rise in temperature of the dampers was measured during the tests.It was found that output force of the manufactured devices was virtually independent of temperature even during long duration loadings.Accordingly,temperature dependence can be ignored in CFD models,because a reliable temperature compensator mechanism was used(or intended to be used)by the damper manufacturer.展开更多
After nearly a decade of application and investigation, a motion amplification device with viscous dampers for energy dissipation has been recognized as an effective solution to mitigate wind or seismic excitation, es...After nearly a decade of application and investigation, a motion amplification device with viscous dampers for energy dissipation has been recognized as an effective solution to mitigate wind or seismic excitation, especially for stiff structural systems. As a result of compensation of amplified motion, it has been proved that the efficiency of viscous damper largely depends on the motion amplification device configuration, particularly for device stiflhess. In this paper, a "scissor-jack" type of motion amplification device, called a "toggle brace damper" system, is studied. It is demonstrated that the efficiency of such a device reflected by its amplification factor is not merely a function of its geometric configuration, but is highly dependent on the support elements' stiffness as well, similar to the mechanism of a leverage arm. Accordingly, a mathematical model in terms of complex modulus of the viscous damper with consideration of the support brace's stiffness is established. The results indicate that the efficiency of the motion amplification device with viscous dampers significantly depends on the stiffness of the support elements. Other parameters, such as toggle brace configuration and damping values of the viscous damper, are studied and compared. As an application example, numerical analyses are conducted to study the dynamic performance of a 39-story office tower installed with toggle brace dampers constructed on soft soil in a reclaimed area, under a combined effect of the vortex shedding of an adjacent existing 52-story building and earthquakes. The results show that viscous dampers with a motion amplification system using a properly designed toggle brace device proved to be an effective solution to alleviate the external excitations.展开更多
Large tanks are extensively used for storing water,petrochemicals and fuels.Since they are often cited in earthquake-prone areas,the safe and continuous operation of these important structures must be ensured even whe...Large tanks are extensively used for storing water,petrochemicals and fuels.Since they are often cited in earthquake-prone areas,the safe and continuous operation of these important structures must be ensured even when severe earthquakes occur,since their failure could have devastating financial and socio-environmental consequences.Base-isolation has been widely adopted for the efficient seismic protection of such critical facilities.However,base-isolated tanks can be located relatively close to active faults that generate strong excitations with special characteristics.Consequently,viscous dampers can be incorporated into the isolation system to reduce excessive displacement demands and to avoid overconservative isolator design.Nonetheless,only a few studies have focused on the investigation of seismic response of base-isolated liquid storage tanks in conjunction with supplemental viscous dampers.Therefore,the impact of the addition of supplemental linear viscous dampers on the seismic performance of tanks isolated by single friction pendulum devices is investigated herein.Four levels of supplemental damping are assessed and compared with respect to isolators′displacement capacity and accelerations that are transferred to the tanks.展开更多
A new type of shear viscous damper for rotating machinery is designed. The new damper with good stability and reliability can inhibit all kinds of frequency multiplication vibration caused by misalignment in the condi...A new type of shear viscous damper for rotating machinery is designed. The new damper with good stability and reliability can inhibit all kinds of frequency multiplication vibration caused by misalignment in the condition of nonstop machine. It analyzes and discusses the use of the shear viscous damper for misalignment vibration response inhibition with a finite element method, and experi ments are extensively carried out with a laboratory test rig. Both the simulation and experimental re suits basically agree well in that, the damper can effectively control the misalignment vibration of the rotor system and improves the stability of the plitude of one time running speed component bration has been basically eliminated. entire rotor system. Experimental results show the am decreases by 30% , and the two time running speed vibration has been basically eliminated.展开更多
In order to study the wind-induced vibration control effect of the viscous damper on the large-scale substation frame,this paper takes the large-scale 1000 kV substation frame of western Inner Mongolia as an example.T...In order to study the wind-induced vibration control effect of the viscous damper on the large-scale substation frame,this paper takes the large-scale 1000 kV substation frame of western Inner Mongolia as an example.The time-history sample of pulsating wind load is simulated by harmonic superposition method based on Matlab software.6 kinds of viscous damper arrangement schemes have been designed,and SAP2000 finite element software is used for fine modeling and input wind speed time history load for nonlinear time history analysis.The displacement and acceleration of a typical node are the indicators of wind vibration control.The wind-induced vibration control effects of different schemes under different damping parameters have compared,and the damping parameters are analyzed for the optimal layout scheme.The results show that a viscous damper has installed in the lower layers of the substation;a viscous damper is placed between the ground column and the lattice beam.It is an integrated optimal solution.The wind-induced vibration control effect of the optimal scheme is sensitive to the viscous damper parameters,and the control effect does not increase linearly with the increase of the damping index and the damping coefficient.Corresponding to different damping indexes,the damping coefficient has a better range of values.展开更多
This study proposes a micro vibration mitigation system using viscous dampers to solve the problem of vibration in a high-tech building. Due to the operating frequency of the air conditioners and fundamental mode of t...This study proposes a micro vibration mitigation system using viscous dampers to solve the problem of vibration in a high-tech building. Due to the operating frequency of the air conditioners and fundamental mode of the floors, a resonant phenomenon is occasionally experienced at the upper levels of the structure. Several strategies were considered, and viscous dampers combined with a suspension system were chosen to mitigate this annoying situation. A theoretical analysis was first executed to determine the optimal design value of the damper and the suspension spring. An efficient reduction in floor velocity of approximately 50 % was achieved by the proposed system. Practical verifications including a performance test of the micro-vibration-oriented dampers, the pragmatic application result, and a comparison in one-third octave spectrum was then carried out. The performance of the system was demonstrated by the data measured. It alleviated more trembling than was numerically expected. The energy absorbed by the viscous dampers is illustrated by the hysteresis loops and the one-third octave spectrum. It is found that with the proposed system, the vibration can be effectively captured by the viscous damper and converted to lower frequency-content tremors. The success of this project greatly supports the proposed standard two-stage analysis procedure for mitigating micro-vibration problems in practice. This research extends the use of viscous dampers to a new field.展开更多
The optimal distribution of fluid viscous dampers(FVD)in controlling the seismic response of eccentric,single-storey,moment resisting concrete structures is investigated using the previously defined center of dampin...The optimal distribution of fluid viscous dampers(FVD)in controlling the seismic response of eccentric,single-storey,moment resisting concrete structures is investigated using the previously defined center of damping constant(CDC).For this purpose,a number of structural models with different one-way stiffness and strength eccentricities are considered.Extensive nonlinear time history analyses are carried out for various arrangements of FVDs.It is shown that the arrangement of FVDs for controlling the torsional behavior due to asymmetry in the concrete structures is very dependent on the intensity of the peak ground acceleration(PGA)and the extent of the structural stiffness and strength eccentricities.The results indicate that,in the linear range of structural behavior the stiffness eccentricity es which is the main parameter in determining the location of optimal CDC,is found to be less or smaller than the optimal damping constant eccentricity e*d,i.e.,|e*d| 〉 |es|.But,in the nonlinear range of structural behavior where the strength eccentricity er is the dominant factor in determining the location of optimal CDC,|e*d| 〉 |er|.It is also concluded that for the majority of the plan-asymmetric,concrete structures considered in this study with er ≠ 0,the optimal CDC approaches the center of mass as er decreases.展开更多
Quasi-zero-stiffness(QZS)vibration isolators have been widely studied,because they show excellent high static and low dynamic stiffnesses and can effectively solve low-frequency and ultralow-frequency vibration.Howeve...Quasi-zero-stiffness(QZS)vibration isolators have been widely studied,because they show excellent high static and low dynamic stiffnesses and can effectively solve low-frequency and ultralow-frequency vibration.However,traditional QZS(T-QZS)vibration isolators usually adopt linear damping,owing to which achieving good isolation performance at both low and high frequencies is difficult.T-QZS isolators exhibit hardening stiffness characteristics,and their vibration isolation performance is even worse than that of linear vibration isolators under a large excitation amplitude.Therefore,this study proposes a QZS isolator with a shear-thinning viscous damper(SVD)to improve the vibration isolation performance of the T-QZS isolators.The force-velocity relation of the SVD is obtained,and a dynamic model is established for the isolator.The dynamic responses of the system are solved using the harmonic balance method(HBM)and the Runge-Kutta method.The vibration isolation performance of the system is evaluated using force transmissibility,and the isolator parameters are analyzed.The results show that compared with the T-QZS isolators,the proposed QZS-SVD isolator achieves the lower initial vibration isolation frequency and peak value,and exhibits better vibration isolation performance at medium and high frequencies.Moreover,the proposed isolator can withstand a large excitation amplitude in the effective vibration isolation range.展开更多
The centrifugal air compressor outlet pipeline vibration was not decreased after barrel viscous dampers were installed in a petrochemical plant in Tianjin.A pipeline-damper experiment apparatus was built for studying ...The centrifugal air compressor outlet pipeline vibration was not decreased after barrel viscous dampers were installed in a petrochemical plant in Tianjin.A pipeline-damper experiment apparatus was built for studying the influence factors of the barrel viscous damper and pipe hoop in pipeline vibration reduction.The performance of the damper under different frequency and amplitude was researched respectively,the results showed that damping effect dependsed mainly on frequency and was not related to amplitude.Damper will fail when its vibration frequency exceeds its limit working frequency which was 40 Hz in test.The mechanical properties and energy dissipation were analyzed by using the Maxwell model,which explains experimental results well.According to damping effect and calculation of stiffness with ANSYS in different hoop width,hoop stiffness should match pipe stiffness and keep uniform along transfer path.Damping effect will get worse when local stiffness is too small or too large.Finally,the outlet pipeline vibration was decreased by 70%after using appropriate pipe hoop width and replacing the original damping liquid.展开更多
Seismic fragility analysis of three-tower cable-stayed bridges with three different structural systems,including rigid system(RS),floating system(FS),and passive energy dissipation system(PEDS),is conducted to study t...Seismic fragility analysis of three-tower cable-stayed bridges with three different structural systems,including rigid system(RS),floating system(FS),and passive energy dissipation system(PEDS),is conducted to study the effects of connection configurations on seismic responses and fragilities.Finite element models of bridges are established using OpenSees.A new ground motion screening method based on the statistical characteristic of the predominant period is proposed to avoid irregular behavior in the selection process of ground motions,and incremental dynamic analysis(IDA)is performed to develop components and systems fragility curves.The effects of damper failure on calculated results for PEDS are examined in terms of seismic response and fragility analysis.The results show that the bridge tower is the most affected component by different structural systems.For RS,the fragility of the middle tower is significantly higher than other components,and the bridge failure starts from the middle tower,exhibiting a characteristic of local failure.For FS and PEDS,the fragility of the edge tower is higher than the middle tower.The system fragility of RS is higher than FS and PEDS.Taking the failure of dampers into account is necessary to obtain reliable seismic capacity of cable-stayed bridges.展开更多
Viscous dampers are widely used as passive energy dissipation devices for long-span cable-stayed bridges for mitigation of seismic load-induced vibrations.However,complicated finite element(FE)modeling,together with r...Viscous dampers are widely used as passive energy dissipation devices for long-span cable-stayed bridges for mitigation of seismic load-induced vibrations.However,complicated finite element(FE)modeling,together with repetitive and computationally intensive nonlinear time-history analyses(NTHAs)are generally required in conventional design methods.To streamline the preliminary design process,this paper developed a simplified longitudinal double degree of freedom model(DDFM)for single and symmetric twin-tower cable-stayed bridges.Based on the proposed simplified longitudinal DDFM,the analytical equations for the relevant mass-and stiffness-related parameters and longitudinal natural frequencies of the structure were derived by using analytical and energy methods.Modeling of the relationship between the nonlinear viscous damper parameters and the equivalent damping ratio was achieved through the equivalent linearization method.Additionally,the analytical equations of longitudinal seismic responses for long-span cable-stayed bridges with nonlinear viscous dampers were derived.Based on the developed simplified DDFM and suggested analytical equations,this paper proposed a simplified calculation framework to achieve a simplified design method of nonlinear viscous damper parameters.Moreover,the effectiveness and applicability of the developed simplified longitudinal DDFM and the proposed calculation framework were further validated through numerical analysis of a practical cable-stayed bridge.Finally,the results indicated the following.1)For the obtained fundamental period and longitudinal stiffness,the differences between results of the simplified longitudinal DDFM and numerical analysis were only 2.05%and 1.5%,respectively.2)Relative calculation errors of the longitudinal girder-end displacement and bending moment of the bottom tower section of the bridge obtained from the simplified longitudinal DDFM were limited to less than 25%.3)The equivalent damping ratio of nonlinear viscous dampers and the applied loading frequency had significant effects on the longitudinal seismic responses of the bridge.Findings of this study may provide beneficial information for a design office to make a simplified preliminary design scheme to determine the appropriate nonlinear damper parameters and longitudinal seismic responses for long-span cable-stayed bridges.展开更多
Impact dampers are usually used to suppress single mode resonance. The goal of this paper is to clarify the difference when the impact damper suppresses the resonances of different modes. A cantilever beam equipped wi...Impact dampers are usually used to suppress single mode resonance. The goal of this paper is to clarify the difference when the impact damper suppresses the resonances of different modes. A cantilever beam equipped with the impact damper is modeled. The elastic contact of the ball and the cantilever beam is described by using the Hertz contact model. The viscous damper between the ball and the cantilever beam is modeled to consume the vibrational energy of the cantilever beam. A piecewise ordinary differential-partial differential equation of the cantilever beam is established, including equations with and without the impact damper. The vibration responses of the cantilever beam with and without the impact damper are numerically calculated. The effects of the impact absorber parameters on the vibration reduction are examined. The results show that multiple resonance peaks of the cantilever beam can be effectively suppressed by the impact damper. Specifically, all resonance amplitudes can be reduced by a larger weight ball. Moreover, the impacting gap is very effective in suppressing the vibration of the cantilever beam. More importantly, there is an optimal impacting gap for each resonance mode of the cantilever beam, but the optimal gap for each mode is different.展开更多
The newly proposed mega sub-controlled structure system(MSCSS)and related studies have drawn the attention of civil engineers for practice in improving the performance and enhancing the structural effectiveness of meg...The newly proposed mega sub-controlled structure system(MSCSS)and related studies have drawn the attention of civil engineers for practice in improving the performance and enhancing the structural effectiveness of mega frame structures.However,there is still a need for improvement to its basic structural arrangement.In this project,an advanced,reasonable arrangement of mega sub-controlled structure models,composed of three mega stories with different numbers and arrangements of substructures,are designed to investigate the control performance of the models and obtain the optimal model configuration(model with minimum acceleration and displacement responses)under strong earthquake excitation.In addition,the dynamic parameters that affect the performance effectiveness of the optimal model of MSCSS are studied and discussed.The area of the relative stiffness ratio RD,with different mass ratio MR,within which the acceleration and displacement of the optimal model of MSCSS reaches its optimum(minimum)value is considered as an optimum region.It serves as a useful tool in practical engineering design.The study demonstrates that the proposed MSCSS configuration can efficiently control the displacement and acceleration of high rise buildings.In addition,some analytical guidelines are provided for selecting the control parameters of the structure.展开更多
In a viscous damping device under cyclic loading, after the piston reaches a peak stroke, the reserve movement that follows may sometimes experience a short period of delayed or significantly reduced device force outp...In a viscous damping device under cyclic loading, after the piston reaches a peak stroke, the reserve movement that follows may sometimes experience a short period of delayed or significantly reduced device force output. A similar delay or reduced device force output may also occur at the damper's initial stroke as it moves away from its neutral position. This phenomenon is referred to as the effect of "deadzone". The deadzone can cause a loss of energy dissipation capacity and less efficient vibration control. It is prominent in small amplitude vibrations. Although there are many potential causes of deadzone such as environmental factors, construction, material aging, and manufacture quality, in this paper, its general effect in linear and nonlinear viscous damping devices is analyzed. Based on classical dynamics and damping theory, a simple model is developed to capture the effect ofdeadzone in terms of the loss of energy dissipation capacity. The model provides several methods to estimate the loss of energy dissipation within the deadzone in linear and sublinear viscous fluid dampers. An empirical equation of loss of energy dissipation capacity versus deadzone size is formulated, and the equivalent reduction of effective damping in SDOF systems has been obtained. A laboratory experimental evaluation is carried out to verify the effect of deadzone and its numerical approximation. Based on the analysis, a modification is suggested to the corresponding formulas in FEMA 3 5 6 for calculation of equivalent damping if a deadzone is to be considered.展开更多
A new method of robust damper design is presented for elastic-plastic multi-degree-of-freedom(MDOF)building structures under multi-level ground motions(GMs).This method realizes a design that is effective for various ...A new method of robust damper design is presented for elastic-plastic multi-degree-of-freedom(MDOF)building structures under multi-level ground motions(GMs).This method realizes a design that is effective for various levels of GMs.The robustness of a design is measured by an incremental dynamic analysis(IDA)curve and an ideal drift response curve(IDRC).The IDRC is a plot of the optimized maximum deformation under a constraint on the total damper quantity vs.the design level of the GMs.The total damper quantity corresponds to the total cost of the added dampers.First,a problem of generation of IDRCs is stated.Then,its solution algorithm,which consists of the sensitivity-based algorithm(SBA)and a local search method,is proposed.In the application of the SBA,the passive added dampers are removed sequentially under the specified-level GMs.On the other hand,the proposed local search method can search the optimal solutions for a constant total damper quantity under GMs’increased levels.In this way,combining these two algorithms enables the comprehensive search of the optimal solutions for various conditions of the status of the GMs and the total damper quantity.The influence of selecting the type of added dampers(oil,hysteretic,and so on)and the selection of the input GMs on the IDRCs are investigated.Finally,a robust optimal design problem is formulated,and a simple local search-based algorithm is proposed.A simple index using the IDRC and the IDA curve of the model is used as the objective function.It is demonstrated that the proposed algorithm works well in spite of its simplicity.展开更多
The report summarizes the observed damage to a variety of buildings near the epicenter of the M6.8 Luding earthquake in Sichuan Province,China.They include base-isolated buildings,multi-story reinforced concrete(RC)fr...The report summarizes the observed damage to a variety of buildings near the epicenter of the M6.8 Luding earthquake in Sichuan Province,China.They include base-isolated buildings,multi-story reinforced concrete(RC)frame buildings,and masonry buildings.The near-field region is known to be tectonically highly active,and the local intensity level is the highest,that is,0.4g peak ground acceleration(PGA)for the design basis earthquake,in the Chinese zonation of seismic ground motion parameters.The extent of damage ranged from the weak-story collapse that claimed lives to the extensive nonstructural damage that suspended occupancy.The report highlights the first observation of the destruction of rubber bearings and viscous dampers in the isolation layer of Chinese seismically isolated buildings.It also features the rare observation of the brittle shear failure of RC columns in moment-resisting frames in a region of such a high seismic design requirement.Possible reasons that may have attributed to the reported damage are suggested by providing facts observed in the field.However,careful forensic analyses are needed before any conclusive judgment can be made.展开更多
Performance analysis of the Pangu Plaza under earthquake and wind loads is described in this paper. The plaza is a 39-story steel high-rise building, 191 m high, located in Beijing close to the 2008 Olympic main stadi...Performance analysis of the Pangu Plaza under earthquake and wind loads is described in this paper. The plaza is a 39-story steel high-rise building, 191 m high, located in Beijing close to the 2008 Olympic main stadium. It has both fluid viscous dampers (FVDs) and buckling restrained braces or unbonded brace (BRB or UBB) installed. A repeated iteration procedure in its design and analysis was adopted for optimization. Results from the seismic response analysis in the horizontal and vertical directions show that the FVDs are highly effective in reducing the response of both the main structure and the secondary system. A comparative analysis of structural seismic performance and economic impact was conducted using traditional methods, i.e., increased size of steel columns and beams and/or use of an increased number of seismic braces versus using FVD. Both the structural response and economic analysis show that using FVD to absorb seismic energy not only satisfies the Chinese seismic design code for a "rare" earthquake, but is also the most economical way to improve seismic performance both for one-time direct investment and long term maintenance.展开更多
In this study,the dynamic behavior of a developed bypass viscous damper is evaluated.Bypass viscous damper has a flexible hose as an external orifice through which the inside fluid transfer from one side to the other ...In this study,the dynamic behavior of a developed bypass viscous damper is evaluated.Bypass viscous damper has a flexible hose as an external orifice through which the inside fluid transfer from one side to the other side of the inner piston.Accordingly,the viscosity coficient of the damper can be adjusted using geometrical dimensions of the hose.Moreover,the external orifice acts as a thermal compensator and alleviates viscous heating of the damper.According to experimental results,Computational Fluid Dynamic(CFD)model,a numerical formula and the simplified.Maxwell model are found and assessed;therefore,the verification of numerical and computational models are evaluated for simulating.Also,a simplifed procedure is proposed to design structures with bypass viscous dampers.The design procedure is applied to design an 8-story hospital structure with bypass viscous dampers,and it is compared with the same structure,which is designed with concentric braces and without dampers.Nonlinear time history analyses revealed that the hospital with viscous damper experiences less structural inelastic demands and fewer story accelerations which mean fewer demands on nonstructural elements.Moreover,seismic behaviors of nonstructural masonry claddings are also compared in the cases of hospital structure with and without dampers.展开更多
A series of shake-table tests was conducted by inserting and replacing 4 different types of dampers,or by removing them in a full-scale 5-story steel frame building. The objective is to validate response-control techn...A series of shake-table tests was conducted by inserting and replacing 4 different types of dampers,or by removing them in a full-scale 5-story steel frame building. The objective is to validate response-control technologies that are increasingly adopted for major Japanese buildings without being attested to-date by a major earthquake. Test results are briefly described,and good performance of the dampers and frame demonstrated. The concepts of the full-scale building tests and various contributions are discussed. The difficulty associated with full-scale dynamic testing is explained.展开更多
文摘Tension cables are easily prone to generating varied vibrations under the action of external loads, which adversely affects the safety of bridges. Therefore, it is necessary to take effective measures to suppress the vibrations of tension cables. Cable end dampers are widely used in vibration reduction for cable-stayed bridges due to their convenient installation and low costs. However, the previous studies on the tension cable-viscous damper systems mostly adopt the linear method, and the weakening effect of the flexibility of mounting brackets on the damper vibration reduction is not sufficiently taken into account. Therefore, this paper adopts the improved Kelvin model to conduct the derivation, solution, and parametric analysis of vibration equations for the stay cable-nonlinear viscous damper systems. The results of parametric analysis show that the maximum modal damping ratio that can be obtained by cables and the corresponding optimal damping coefficient of dampers are correlated with the damping nonlinear coefficient α, stiffness nonlinear coefficient β, vibration order n, installation position a/L, and stiffness coefficient μ, etc.;among them, n damping nonlinear coefficient α and stiffness nonlinear coefficient β are the key parameters that affect the parameter design of dampers, where damping nonlinear coefficient α mainly controls the optimal damping coefficient and stiffness nonlinear coefficient β mainly controls the maximum damping ratio. Based on the parametric analysis, the design principles of dampers and value requirements of key parameters under different vibration suppression objectives are presented.
文摘Computational fluid dynamics(CFD)provides a powerful tool for investigating complicated fluid flows.This paper aims to study the applicability of CFD in the preliminary design of linear and nonlinear fluid viscous dampers.Two fluid viscous dampers were designed based on CFD models.The first device was a linear viscous damper with straight orifices.The second was a nonlinear viscous damper containing a one-way pressure-responsive valve inside its orifices.Both dampers were detailed based on CFD simulations,and their internal fluid flows were investigated.Full-scale specimens of both dampers were manufactured and tested under dynamic loads.According to the tests results,both dampers demonstrate stable cyclic behaviors,and as expected,the nonlinear damper generally tends to dissipate more energy compared to its linear counterpart.Good compatibility was achieved between the experimentally measured damper force-velocity curves and those estimated from CFD analyses.Using a thermography camera,a rise in temperature of the dampers was measured during the tests.It was found that output force of the manufactured devices was virtually independent of temperature even during long duration loadings.Accordingly,temperature dependence can be ignored in CFD models,because a reliable temperature compensator mechanism was used(or intended to be used)by the damper manufacturer.
文摘After nearly a decade of application and investigation, a motion amplification device with viscous dampers for energy dissipation has been recognized as an effective solution to mitigate wind or seismic excitation, especially for stiff structural systems. As a result of compensation of amplified motion, it has been proved that the efficiency of viscous damper largely depends on the motion amplification device configuration, particularly for device stiflhess. In this paper, a "scissor-jack" type of motion amplification device, called a "toggle brace damper" system, is studied. It is demonstrated that the efficiency of such a device reflected by its amplification factor is not merely a function of its geometric configuration, but is highly dependent on the support elements' stiffness as well, similar to the mechanism of a leverage arm. Accordingly, a mathematical model in terms of complex modulus of the viscous damper with consideration of the support brace's stiffness is established. The results indicate that the efficiency of the motion amplification device with viscous dampers significantly depends on the stiffness of the support elements. Other parameters, such as toggle brace configuration and damping values of the viscous damper, are studied and compared. As an application example, numerical analyses are conducted to study the dynamic performance of a 39-story office tower installed with toggle brace dampers constructed on soft soil in a reclaimed area, under a combined effect of the vortex shedding of an adjacent existing 52-story building and earthquakes. The results show that viscous dampers with a motion amplification system using a properly designed toggle brace device proved to be an effective solution to alleviate the external excitations.
文摘Large tanks are extensively used for storing water,petrochemicals and fuels.Since they are often cited in earthquake-prone areas,the safe and continuous operation of these important structures must be ensured even when severe earthquakes occur,since their failure could have devastating financial and socio-environmental consequences.Base-isolation has been widely adopted for the efficient seismic protection of such critical facilities.However,base-isolated tanks can be located relatively close to active faults that generate strong excitations with special characteristics.Consequently,viscous dampers can be incorporated into the isolation system to reduce excessive displacement demands and to avoid overconservative isolator design.Nonetheless,only a few studies have focused on the investigation of seismic response of base-isolated liquid storage tanks in conjunction with supplemental viscous dampers.Therefore,the impact of the addition of supplemental linear viscous dampers on the seismic performance of tanks isolated by single friction pendulum devices is investigated herein.Four levels of supplemental damping are assessed and compared with respect to isolators′displacement capacity and accelerations that are transferred to the tanks.
基金Supported by the National Basic Research Program of China(No.2012CB026000)the Joint Project Special Fund of Education Committee of Beijingthe Ph.D.Programs Foundation of Ministry of Education of China(No.20110010110009)
文摘A new type of shear viscous damper for rotating machinery is designed. The new damper with good stability and reliability can inhibit all kinds of frequency multiplication vibration caused by misalignment in the condition of nonstop machine. It analyzes and discusses the use of the shear viscous damper for misalignment vibration response inhibition with a finite element method, and experi ments are extensively carried out with a laboratory test rig. Both the simulation and experimental re suits basically agree well in that, the damper can effectively control the misalignment vibration of the rotor system and improves the stability of the plitude of one time running speed component bration has been basically eliminated. entire rotor system. Experimental results show the am decreases by 30% , and the two time running speed vibration has been basically eliminated.
文摘In order to study the wind-induced vibration control effect of the viscous damper on the large-scale substation frame,this paper takes the large-scale 1000 kV substation frame of western Inner Mongolia as an example.The time-history sample of pulsating wind load is simulated by harmonic superposition method based on Matlab software.6 kinds of viscous damper arrangement schemes have been designed,and SAP2000 finite element software is used for fine modeling and input wind speed time history load for nonlinear time history analysis.The displacement and acceleration of a typical node are the indicators of wind vibration control.The wind-induced vibration control effects of different schemes under different damping parameters have compared,and the damping parameters are analyzed for the optimal layout scheme.The results show that a viscous damper has installed in the lower layers of the substation;a viscous damper is placed between the ground column and the lattice beam.It is an integrated optimal solution.The wind-induced vibration control effect of the optimal scheme is sensitive to the viscous damper parameters,and the control effect does not increase linearly with the increase of the damping index and the damping coefficient.Corresponding to different damping indexes,the damping coefficient has a better range of values.
文摘This study proposes a micro vibration mitigation system using viscous dampers to solve the problem of vibration in a high-tech building. Due to the operating frequency of the air conditioners and fundamental mode of the floors, a resonant phenomenon is occasionally experienced at the upper levels of the structure. Several strategies were considered, and viscous dampers combined with a suspension system were chosen to mitigate this annoying situation. A theoretical analysis was first executed to determine the optimal design value of the damper and the suspension spring. An efficient reduction in floor velocity of approximately 50 % was achieved by the proposed system. Practical verifications including a performance test of the micro-vibration-oriented dampers, the pragmatic application result, and a comparison in one-third octave spectrum was then carried out. The performance of the system was demonstrated by the data measured. It alleviated more trembling than was numerically expected. The energy absorbed by the viscous dampers is illustrated by the hysteresis loops and the one-third octave spectrum. It is found that with the proposed system, the vibration can be effectively captured by the viscous damper and converted to lower frequency-content tremors. The success of this project greatly supports the proposed standard two-stage analysis procedure for mitigating micro-vibration problems in practice. This research extends the use of viscous dampers to a new field.
文摘The optimal distribution of fluid viscous dampers(FVD)in controlling the seismic response of eccentric,single-storey,moment resisting concrete structures is investigated using the previously defined center of damping constant(CDC).For this purpose,a number of structural models with different one-way stiffness and strength eccentricities are considered.Extensive nonlinear time history analyses are carried out for various arrangements of FVDs.It is shown that the arrangement of FVDs for controlling the torsional behavior due to asymmetry in the concrete structures is very dependent on the intensity of the peak ground acceleration(PGA)and the extent of the structural stiffness and strength eccentricities.The results indicate that,in the linear range of structural behavior the stiffness eccentricity es which is the main parameter in determining the location of optimal CDC,is found to be less or smaller than the optimal damping constant eccentricity e*d,i.e.,|e*d| 〉 |es|.But,in the nonlinear range of structural behavior where the strength eccentricity er is the dominant factor in determining the location of optimal CDC,|e*d| 〉 |er|.It is also concluded that for the majority of the plan-asymmetric,concrete structures considered in this study with er ≠ 0,the optimal CDC approaches the center of mass as er decreases.
基金Project supported by the Key Program of National Natural Science Foundation of China(No.11832009)the National Natural Science Foundation of China(Nos.11902085 and 12172095)the Natural Science Foundation of Guangdong Province of China(No.2021A1515010320)
文摘Quasi-zero-stiffness(QZS)vibration isolators have been widely studied,because they show excellent high static and low dynamic stiffnesses and can effectively solve low-frequency and ultralow-frequency vibration.However,traditional QZS(T-QZS)vibration isolators usually adopt linear damping,owing to which achieving good isolation performance at both low and high frequencies is difficult.T-QZS isolators exhibit hardening stiffness characteristics,and their vibration isolation performance is even worse than that of linear vibration isolators under a large excitation amplitude.Therefore,this study proposes a QZS isolator with a shear-thinning viscous damper(SVD)to improve the vibration isolation performance of the T-QZS isolators.The force-velocity relation of the SVD is obtained,and a dynamic model is established for the isolator.The dynamic responses of the system are solved using the harmonic balance method(HBM)and the Runge-Kutta method.The vibration isolation performance of the system is evaluated using force transmissibility,and the isolator parameters are analyzed.The results show that compared with the T-QZS isolators,the proposed QZS-SVD isolator achieves the lower initial vibration isolation frequency and peak value,and exhibits better vibration isolation performance at medium and high frequencies.Moreover,the proposed isolator can withstand a large excitation amplitude in the effective vibration isolation range.
基金Supported by the National Basic Research Program of China(No.2012CB026000)the Beijing Education Commission Special Fund andDoctoral Degree Fund(No.20110010110009)
文摘The centrifugal air compressor outlet pipeline vibration was not decreased after barrel viscous dampers were installed in a petrochemical plant in Tianjin.A pipeline-damper experiment apparatus was built for studying the influence factors of the barrel viscous damper and pipe hoop in pipeline vibration reduction.The performance of the damper under different frequency and amplitude was researched respectively,the results showed that damping effect dependsed mainly on frequency and was not related to amplitude.Damper will fail when its vibration frequency exceeds its limit working frequency which was 40 Hz in test.The mechanical properties and energy dissipation were analyzed by using the Maxwell model,which explains experimental results well.According to damping effect and calculation of stiffness with ANSYS in different hoop width,hoop stiffness should match pipe stiffness and keep uniform along transfer path.Damping effect will get worse when local stiffness is too small or too large.Finally,the outlet pipeline vibration was decreased by 70%after using appropriate pipe hoop width and replacing the original damping liquid.
基金National Key R&D Program of China under Grant No.2022YFC3003603。
文摘Seismic fragility analysis of three-tower cable-stayed bridges with three different structural systems,including rigid system(RS),floating system(FS),and passive energy dissipation system(PEDS),is conducted to study the effects of connection configurations on seismic responses and fragilities.Finite element models of bridges are established using OpenSees.A new ground motion screening method based on the statistical characteristic of the predominant period is proposed to avoid irregular behavior in the selection process of ground motions,and incremental dynamic analysis(IDA)is performed to develop components and systems fragility curves.The effects of damper failure on calculated results for PEDS are examined in terms of seismic response and fragility analysis.The results show that the bridge tower is the most affected component by different structural systems.For RS,the fragility of the middle tower is significantly higher than other components,and the bridge failure starts from the middle tower,exhibiting a characteristic of local failure.For FS and PEDS,the fragility of the edge tower is higher than the middle tower.The system fragility of RS is higher than FS and PEDS.Taking the failure of dampers into account is necessary to obtain reliable seismic capacity of cable-stayed bridges.
基金supported by the National Natural Science Foundation of China(Grant Nos.51978257 and 52278176)。
文摘Viscous dampers are widely used as passive energy dissipation devices for long-span cable-stayed bridges for mitigation of seismic load-induced vibrations.However,complicated finite element(FE)modeling,together with repetitive and computationally intensive nonlinear time-history analyses(NTHAs)are generally required in conventional design methods.To streamline the preliminary design process,this paper developed a simplified longitudinal double degree of freedom model(DDFM)for single and symmetric twin-tower cable-stayed bridges.Based on the proposed simplified longitudinal DDFM,the analytical equations for the relevant mass-and stiffness-related parameters and longitudinal natural frequencies of the structure were derived by using analytical and energy methods.Modeling of the relationship between the nonlinear viscous damper parameters and the equivalent damping ratio was achieved through the equivalent linearization method.Additionally,the analytical equations of longitudinal seismic responses for long-span cable-stayed bridges with nonlinear viscous dampers were derived.Based on the developed simplified DDFM and suggested analytical equations,this paper proposed a simplified calculation framework to achieve a simplified design method of nonlinear viscous damper parameters.Moreover,the effectiveness and applicability of the developed simplified longitudinal DDFM and the proposed calculation framework were further validated through numerical analysis of a practical cable-stayed bridge.Finally,the results indicated the following.1)For the obtained fundamental period and longitudinal stiffness,the differences between results of the simplified longitudinal DDFM and numerical analysis were only 2.05%and 1.5%,respectively.2)Relative calculation errors of the longitudinal girder-end displacement and bending moment of the bottom tower section of the bridge obtained from the simplified longitudinal DDFM were limited to less than 25%.3)The equivalent damping ratio of nonlinear viscous dampers and the applied loading frequency had significant effects on the longitudinal seismic responses of the bridge.Findings of this study may provide beneficial information for a design office to make a simplified preliminary design scheme to determine the appropriate nonlinear damper parameters and longitudinal seismic responses for long-span cable-stayed bridges.
基金the National Natural Science Foundation of China(No.11772181)the Program of Shanghai Municipal Education Commission(No.2019-01-07-00-09-E0018)the Key Research Projects of Shanghai Science and Technology Commission(No.18010500100)。
文摘Impact dampers are usually used to suppress single mode resonance. The goal of this paper is to clarify the difference when the impact damper suppresses the resonances of different modes. A cantilever beam equipped with the impact damper is modeled. The elastic contact of the ball and the cantilever beam is described by using the Hertz contact model. The viscous damper between the ball and the cantilever beam is modeled to consume the vibrational energy of the cantilever beam. A piecewise ordinary differential-partial differential equation of the cantilever beam is established, including equations with and without the impact damper. The vibration responses of the cantilever beam with and without the impact damper are numerically calculated. The effects of the impact absorber parameters on the vibration reduction are examined. The results show that multiple resonance peaks of the cantilever beam can be effectively suppressed by the impact damper. Specifically, all resonance amplitudes can be reduced by a larger weight ball. Moreover, the impacting gap is very effective in suppressing the vibration of the cantilever beam. More importantly, there is an optimal impacting gap for each resonance mode of the cantilever beam, but the optimal gap for each mode is different.
基金National Natural Science Foundation of China under Grant No.51878274。
文摘The newly proposed mega sub-controlled structure system(MSCSS)and related studies have drawn the attention of civil engineers for practice in improving the performance and enhancing the structural effectiveness of mega frame structures.However,there is still a need for improvement to its basic structural arrangement.In this project,an advanced,reasonable arrangement of mega sub-controlled structure models,composed of three mega stories with different numbers and arrangements of substructures,are designed to investigate the control performance of the models and obtain the optimal model configuration(model with minimum acceleration and displacement responses)under strong earthquake excitation.In addition,the dynamic parameters that affect the performance effectiveness of the optimal model of MSCSS are studied and discussed.The area of the relative stiffness ratio RD,with different mass ratio MR,within which the acceleration and displacement of the optimal model of MSCSS reaches its optimum(minimum)value is considered as an optimum region.It serves as a useful tool in practical engineering design.The study demonstrates that the proposed MSCSS configuration can efficiently control the displacement and acceleration of high rise buildings.In addition,some analytical guidelines are provided for selecting the control parameters of the structure.
文摘In a viscous damping device under cyclic loading, after the piston reaches a peak stroke, the reserve movement that follows may sometimes experience a short period of delayed or significantly reduced device force output. A similar delay or reduced device force output may also occur at the damper's initial stroke as it moves away from its neutral position. This phenomenon is referred to as the effect of "deadzone". The deadzone can cause a loss of energy dissipation capacity and less efficient vibration control. It is prominent in small amplitude vibrations. Although there are many potential causes of deadzone such as environmental factors, construction, material aging, and manufacture quality, in this paper, its general effect in linear and nonlinear viscous damping devices is analyzed. Based on classical dynamics and damping theory, a simple model is developed to capture the effect ofdeadzone in terms of the loss of energy dissipation capacity. The model provides several methods to estimate the loss of energy dissipation within the deadzone in linear and sublinear viscous fluid dampers. An empirical equation of loss of energy dissipation capacity versus deadzone size is formulated, and the equivalent reduction of effective damping in SDOF systems has been obtained. A laboratory experimental evaluation is carried out to verify the effect of deadzone and its numerical approximation. Based on the analysis, a modification is suggested to the corresponding formulas in FEMA 3 5 6 for calculation of equivalent damping if a deadzone is to be considered.
基金Part of the present work is supported by the Grant-in-Aid for Scientific Research(KAKENHI)of the Japan Society for the Promotion of Science(Nos.18H01584,JP20J20811)This support is greatly appreciated.
文摘A new method of robust damper design is presented for elastic-plastic multi-degree-of-freedom(MDOF)building structures under multi-level ground motions(GMs).This method realizes a design that is effective for various levels of GMs.The robustness of a design is measured by an incremental dynamic analysis(IDA)curve and an ideal drift response curve(IDRC).The IDRC is a plot of the optimized maximum deformation under a constraint on the total damper quantity vs.the design level of the GMs.The total damper quantity corresponds to the total cost of the added dampers.First,a problem of generation of IDRCs is stated.Then,its solution algorithm,which consists of the sensitivity-based algorithm(SBA)and a local search method,is proposed.In the application of the SBA,the passive added dampers are removed sequentially under the specified-level GMs.On the other hand,the proposed local search method can search the optimal solutions for a constant total damper quantity under GMs’increased levels.In this way,combining these two algorithms enables the comprehensive search of the optimal solutions for various conditions of the status of the GMs and the total damper quantity.The influence of selecting the type of added dampers(oil,hysteretic,and so on)and the selection of the input GMs on the IDRCs are investigated.Finally,a robust optimal design problem is formulated,and a simple local search-based algorithm is proposed.A simple index using the IDRC and the IDA curve of the model is used as the objective function.It is demonstrated that the proposed algorithm works well in spite of its simplicity.
基金the Natural Science Foundation of China(52122811).
文摘The report summarizes the observed damage to a variety of buildings near the epicenter of the M6.8 Luding earthquake in Sichuan Province,China.They include base-isolated buildings,multi-story reinforced concrete(RC)frame buildings,and masonry buildings.The near-field region is known to be tectonically highly active,and the local intensity level is the highest,that is,0.4g peak ground acceleration(PGA)for the design basis earthquake,in the Chinese zonation of seismic ground motion parameters.The extent of damage ranged from the weak-story collapse that claimed lives to the extensive nonstructural damage that suspended occupancy.The report highlights the first observation of the destruction of rubber bearings and viscous dampers in the isolation layer of Chinese seismically isolated buildings.It also features the rare observation of the brittle shear failure of RC columns in moment-resisting frames in a region of such a high seismic design requirement.Possible reasons that may have attributed to the reported damage are suggested by providing facts observed in the field.However,careful forensic analyses are needed before any conclusive judgment can be made.
文摘Performance analysis of the Pangu Plaza under earthquake and wind loads is described in this paper. The plaza is a 39-story steel high-rise building, 191 m high, located in Beijing close to the 2008 Olympic main stadium. It has both fluid viscous dampers (FVDs) and buckling restrained braces or unbonded brace (BRB or UBB) installed. A repeated iteration procedure in its design and analysis was adopted for optimization. Results from the seismic response analysis in the horizontal and vertical directions show that the FVDs are highly effective in reducing the response of both the main structure and the secondary system. A comparative analysis of structural seismic performance and economic impact was conducted using traditional methods, i.e., increased size of steel columns and beams and/or use of an increased number of seismic braces versus using FVD. Both the structural response and economic analysis show that using FVD to absorb seismic energy not only satisfies the Chinese seismic design code for a "rare" earthquake, but is also the most economical way to improve seismic performance both for one-time direct investment and long term maintenance.
文摘In this study,the dynamic behavior of a developed bypass viscous damper is evaluated.Bypass viscous damper has a flexible hose as an external orifice through which the inside fluid transfer from one side to the other side of the inner piston.Accordingly,the viscosity coficient of the damper can be adjusted using geometrical dimensions of the hose.Moreover,the external orifice acts as a thermal compensator and alleviates viscous heating of the damper.According to experimental results,Computational Fluid Dynamic(CFD)model,a numerical formula and the simplified.Maxwell model are found and assessed;therefore,the verification of numerical and computational models are evaluated for simulating.Also,a simplifed procedure is proposed to design structures with bypass viscous dampers.The design procedure is applied to design an 8-story hospital structure with bypass viscous dampers,and it is compared with the same structure,which is designed with concentric braces and without dampers.Nonlinear time history analyses revealed that the hospital with viscous damper experiences less structural inelastic demands and fewer story accelerations which mean fewer demands on nonstructural elements.Moreover,seismic behaviors of nonstructural masonry claddings are also compared in the cases of hospital structure with and without dampers.
文摘A series of shake-table tests was conducted by inserting and replacing 4 different types of dampers,or by removing them in a full-scale 5-story steel frame building. The objective is to validate response-control technologies that are increasingly adopted for major Japanese buildings without being attested to-date by a major earthquake. Test results are briefly described,and good performance of the dampers and frame demonstrated. The concepts of the full-scale building tests and various contributions are discussed. The difficulty associated with full-scale dynamic testing is explained.