Background:In recent decades,several studies have been performed in the field of(non-)use of assistive technology devices(ATs)and have found that many variables are likely to be involved in the decision-making process...Background:In recent decades,several studies have been performed in the field of(non-)use of assistive technology devices(ATs)and have found that many variables are likely to be involved in the decision-making process of whether a person with a disability uses or abandons their aids.In low vision rehabilitation,high variability rates and a variety of reasons for non-use of low vision aids has been reported.Determinants of non-use of ATs have previously been categorized into personal factors,ATs factors,environmental factors of the user,and intervention factors.It is probable that some of these factors are also associated with the use of optical low vision aids(OLVAs).Thus,using a framework about adherence with medical interventions,the aim of this scoping review was to explore barriers and facilitators related to OLVAs(non-)use.Methods:Existing guidelines of the scoping review Methods were used to examine and summarize the extent,range,and nature of findings regarding factor categories associated to OLVAs usage.Searches were conducted using the following online databases:Embase,MedLine,and ERIC without limitation on publication dates.A combination of key words and MeSH terms was used based upon the identified core concepts of the research question:(I)low vision;(II)assistive technology;and(III)adherence.A charting form,a flow chart of the study selection process,and a combination of a descriptive numerical analysis and a thematic analysis of 24 studies were performed.Results:The results of this review indicate high variability rates(range:13-50%,M=24%,SD=10%)of people possessing OLVAs but not using them.Most authors do not use a precise definition of“non-use”,and when a definition is provided,the terminology is inconsistent.As expected,the four categories of variables identified are likely to be involved in OLVAs’(non-)use:(I)the largest number of concerns were personal factors.Several aspects regarding personal characteristics were identified,such as demographic,physical,psychological,social-emotional,and occupational factors.Some variables,such as age,diagnosis and visual acuity were reported as contradictorily influencing the OLVAs’usage;(II)ATs factors were associated with quality,appearance,practical aspects of use and the very type of OLVAs;(III)environmental factors referred to social support,physical barriers,expectations of the social environment,presence of a helper,and stigmatization;(IV)finally,intervention factors consisted of taking into account user’s opinions,positive health care experiences,instruction and training,provision processes,delivery periods,and follow-up services.Conclusions:This scoping review provides the preliminary evidence that factors related to OLVAs non-use could be classified into the same four typical categories described in the theory of non-adherence.These results suggest that strategies intended to enhance adherence might be for OLVAs should focus on these four aspects of device use.展开更多
To assess functional outcomes of optical low vision aids(LVAs) for pediatric visual impairment due to central nervous system(CNS) tumors. A prospective case study was conducted on 15 children with history of CNS tumor...To assess functional outcomes of optical low vision aids(LVAs) for pediatric visual impairment due to central nervous system(CNS) tumors. A prospective case study was conducted on 15 children with history of CNS tumors with mean age of 10.47±1.85 y. Lighthouse distance, near visual acuity tests, cycloplegic refraction, reading speed measurement and visual field examination were done. Prescription of far and near LVAs followed by training sessions. LVPrasad-functional vision questionnaire was done to evaluate performance. Visual impairment was moderate(13.3%), severe(73.3%), profound(6.7%) and near blindness in 6.7%. Telescopes prescribed in 33.4%, video magnifier in 46.7%. Questionnaire scores were significantly improved for distant rather than near tasks(P≤0.05) after training. LVAs rehabilitation is an effective method of improving vision in pediatric visual defects secondary to CNS tumors.展开更多
Smart antennas have received great attention for their potentials to enable communication and perception functions at the same time.However,realizing the function synthesis remains an open challenge,and most existing ...Smart antennas have received great attention for their potentials to enable communication and perception functions at the same time.However,realizing the function synthesis remains an open challenge,and most existing system solutions are limited to narrow operating bands and high complexity and cost.Here,we propose an externally perceivable leakywave antenna(LWA)based on spoof surface plasmon polaritons(SSPPs),which can realize adaptive real-time switching between the“radiating”and“non-radiating”states and beam tracking at different frequencies.With the assistance of computer vision,the smart SSPP-LWA is able to detect the external target user or jammer,and intelligently track the target by self-adjusting the operating frequency.The proposed scheme helps to reduce the power consumption through dynamically controlling the radiating state of the antenna,and improve spectrum utilization and avoid spectrum conflicts through intelligently deciding the radiating frequency.On the other hand,it is also helpful for the physical layer communication security through switching the antenna working state according to the presence of the target and target beam tracking in real time.In addition,the proposed smart antenna can be generalized to other metamaterial systems and could be a candidate for synaesthesia integration in future smart antenna systems.展开更多
This paper presents a travel-aid system for sight-impaired pedestrians in outdoor environment.Unlike many existing travel-aid systems that rely on stereo-vision,the proposed system aims to detect generic obstacles in ...This paper presents a travel-aid system for sight-impaired pedestrians in outdoor environment.Unlike many existing travel-aid systems that rely on stereo-vision,the proposed system aims to detect generic obstacles in a cluttered road environment by using just the single camera attached to user's body.To achieve this goal,the original image is re-sampled and mapped to a bird-eye view virtual plane,on which background edges are sub-sampled while obstacle edges are oversampled.Morphology filters with connected component analysis are used to enhance obstacle edges as edge-blobs with larger size,whereas sparse edges from background are filtered out.Based on the identified obstacles,safe walking areas are estimated by calculating a polar edge histogram.The algorithm is tested in different sidewalk scenes with complex pavements,and its efficiency has been confirmed.展开更多
文摘Background:In recent decades,several studies have been performed in the field of(non-)use of assistive technology devices(ATs)and have found that many variables are likely to be involved in the decision-making process of whether a person with a disability uses or abandons their aids.In low vision rehabilitation,high variability rates and a variety of reasons for non-use of low vision aids has been reported.Determinants of non-use of ATs have previously been categorized into personal factors,ATs factors,environmental factors of the user,and intervention factors.It is probable that some of these factors are also associated with the use of optical low vision aids(OLVAs).Thus,using a framework about adherence with medical interventions,the aim of this scoping review was to explore barriers and facilitators related to OLVAs(non-)use.Methods:Existing guidelines of the scoping review Methods were used to examine and summarize the extent,range,and nature of findings regarding factor categories associated to OLVAs usage.Searches were conducted using the following online databases:Embase,MedLine,and ERIC without limitation on publication dates.A combination of key words and MeSH terms was used based upon the identified core concepts of the research question:(I)low vision;(II)assistive technology;and(III)adherence.A charting form,a flow chart of the study selection process,and a combination of a descriptive numerical analysis and a thematic analysis of 24 studies were performed.Results:The results of this review indicate high variability rates(range:13-50%,M=24%,SD=10%)of people possessing OLVAs but not using them.Most authors do not use a precise definition of“non-use”,and when a definition is provided,the terminology is inconsistent.As expected,the four categories of variables identified are likely to be involved in OLVAs’(non-)use:(I)the largest number of concerns were personal factors.Several aspects regarding personal characteristics were identified,such as demographic,physical,psychological,social-emotional,and occupational factors.Some variables,such as age,diagnosis and visual acuity were reported as contradictorily influencing the OLVAs’usage;(II)ATs factors were associated with quality,appearance,practical aspects of use and the very type of OLVAs;(III)environmental factors referred to social support,physical barriers,expectations of the social environment,presence of a helper,and stigmatization;(IV)finally,intervention factors consisted of taking into account user’s opinions,positive health care experiences,instruction and training,provision processes,delivery periods,and follow-up services.Conclusions:This scoping review provides the preliminary evidence that factors related to OLVAs non-use could be classified into the same four typical categories described in the theory of non-adherence.These results suggest that strategies intended to enhance adherence might be for OLVAs should focus on these four aspects of device use.
文摘To assess functional outcomes of optical low vision aids(LVAs) for pediatric visual impairment due to central nervous system(CNS) tumors. A prospective case study was conducted on 15 children with history of CNS tumors with mean age of 10.47±1.85 y. Lighthouse distance, near visual acuity tests, cycloplegic refraction, reading speed measurement and visual field examination were done. Prescription of far and near LVAs followed by training sessions. LVPrasad-functional vision questionnaire was done to evaluate performance. Visual impairment was moderate(13.3%), severe(73.3%), profound(6.7%) and near blindness in 6.7%. Telescopes prescribed in 33.4%, video magnifier in 46.7%. Questionnaire scores were significantly improved for distant rather than near tasks(P≤0.05) after training. LVAs rehabilitation is an effective method of improving vision in pediatric visual defects secondary to CNS tumors.
基金supports from the National Natural Science Foundation of China(Grant Nos.62288101,and 61971134)National Key Research and Development Program of China(Grant Nos.2021YFB3200502,and 2017YFA0700200)+2 种基金the Major Project of the Natural Science Foundation of Jiangsu Province(Grant No.BK20212002)the Fundamental Research Funds for Central Universities(Grant No.2242021R41078)the 111 Project(Grant No.111-2-05).
文摘Smart antennas have received great attention for their potentials to enable communication and perception functions at the same time.However,realizing the function synthesis remains an open challenge,and most existing system solutions are limited to narrow operating bands and high complexity and cost.Here,we propose an externally perceivable leakywave antenna(LWA)based on spoof surface plasmon polaritons(SSPPs),which can realize adaptive real-time switching between the“radiating”and“non-radiating”states and beam tracking at different frequencies.With the assistance of computer vision,the smart SSPP-LWA is able to detect the external target user or jammer,and intelligently track the target by self-adjusting the operating frequency.The proposed scheme helps to reduce the power consumption through dynamically controlling the radiating state of the antenna,and improve spectrum utilization and avoid spectrum conflicts through intelligently deciding the radiating frequency.On the other hand,it is also helpful for the physical layer communication security through switching the antenna working state according to the presence of the target and target beam tracking in real time.In addition,the proposed smart antenna can be generalized to other metamaterial systems and could be a candidate for synaesthesia integration in future smart antenna systems.
基金The MKE(The Ministry of Knowledge Economy),Korea,under the ITRC(Infor mation Technology Research Center)support programsupervised by the NIPA(National IT Industry Promotion Agency)(NIPA-2012-(C1090-1021-0010))The Brain Korea 21 Project in 2012
文摘This paper presents a travel-aid system for sight-impaired pedestrians in outdoor environment.Unlike many existing travel-aid systems that rely on stereo-vision,the proposed system aims to detect generic obstacles in a cluttered road environment by using just the single camera attached to user's body.To achieve this goal,the original image is re-sampled and mapped to a bird-eye view virtual plane,on which background edges are sub-sampled while obstacle edges are oversampled.Morphology filters with connected component analysis are used to enhance obstacle edges as edge-blobs with larger size,whereas sparse edges from background are filtered out.Based on the identified obstacles,safe walking areas are estimated by calculating a polar edge histogram.The algorithm is tested in different sidewalk scenes with complex pavements,and its efficiency has been confirmed.