期刊文献+
共找到401,302篇文章
< 1 2 250 >
每页显示 20 50 100
Rational and Continuous Measurement of the Emotional Decision Making in Visual Recognition of Facial Emotional Expressions with M.A.R.I.E.: First Half
1
作者 Philippe Granato Shreekumar Vinekar +1 位作者 Jean-Pierre Van Gansberghe Raymond Bruyer 《Open Journal of Psychiatry》 2024年第3期223-264,共42页
Context: The advent of Artificial Intelligence (AI) requires modeling prior to its implementation in algorithms for most human skills. This observation requires us to have a detailed and precise understanding of the i... Context: The advent of Artificial Intelligence (AI) requires modeling prior to its implementation in algorithms for most human skills. This observation requires us to have a detailed and precise understanding of the interfaces of verbal and emotional communications. The progress of AI is significant on the verbal level but modest in terms of the recognition of facial emotions even if this functionality is one of the oldest in humans and is omnipresent in our daily lives. Dysfunction in the ability for facial emotional expressions is present in many brain pathologies encountered by psychiatrists, neurologists, psychotherapists, mental health professionals including social workers. It cannot be objectively verified and measured due to a lack of reliable tools that are valid and consistently sensitive. Indeed, the articles in the scientific literature dealing with Visual-Facial-Emotions-Recognition (ViFaEmRe), suffer from the absence of 1) consensual and rational tools for continuous quantified measurement, 2) operational concepts. We have invented a software that can use computer-morphing attempting to respond to these two obstacles. It is identified as the Method of Analysis and Research of the Integration of Emotions (M.A.R.I.E.). Our primary goal is to use M.A.R.I.E. to understand the physiology of ViFaEmRe in normal healthy subjects by standardizing the measurements. Then, it will allow us to focus on subjects manifesting abnormalities in this ability. Our second goal is to make our contribution to the progress of AI hoping to add the dimension of recognition of facial emotional expressions. Objective: To study: 1) categorical vs dimensional aspects of recognition of ViFaEmRe, 2) universality vs idiosyncrasy, 3) immediate vs ambivalent Emotional-Decision-Making, 4) the Emotional-Fingerprint of a face and 5) creation of population references data. Methods: With M.A.R.I.E. enable a rational quantified measurement of Emotional-Visual-Acuity (EVA) of 1) a) an individual observer, b) in a population aged 20 to 70 years old, 2) measure the range and intensity of expressed emotions by 3 Face-Tests, 3) quantify the performance of a sample of 204 observers with hyper normal measures of cognition, “thymia,” (ibid. defined elsewhere) and low levels of anxiety 4) analysis of the 6 primary emotions. Results: We have individualized the following continuous parameters: 1) “Emotional-Visual-Acuity”, 2) “Visual-Emotional-Feeling”, 3) “Emotional-Quotient”, 4) “Emotional-Deci-sion-Making”, 5) “Emotional-Decision-Making Graph” or “Individual-Gun-Trigger”6) “Emotional-Fingerprint” or “Key-graph”, 7) “Emotional-Finger-print-Graph”, 8) detecting “misunderstanding” and 9) detecting “error”. This allowed us a taxonomy with coding of the face-emotion pair. Each face has specific measurements and graphics. The EVA improves from ages of 20 to 55 years, then decreases. It does not depend on the sex of the observer, nor the face studied. In addition, 1% of people endowed with normal intelligence do not recognize emotions. The categorical dimension is a variable for everyone. The range and intensity of ViFaEmRe is idiosyncratic and not universally uniform. The recognition of emotions is purely categorical for a single individual. It is dimensional for a population sample. Conclusions: Firstly, M.A.R.I.E. has made possible to bring out new concepts and new continuous measurements variables. The comparison between healthy and abnormal individuals makes it possible to take into consideration the significance of this line of study. From now on, these new functional parameters will allow us to identify and name “emotional” disorders or illnesses which can give additional dimension to behavioral disorders in all pathologies that affect the brain. Secondly, the ViFaEmRe is idiosyncratic, categorical, and a function of the identity of the observer and of the observed face. These findings stack up against Artificial Intelligence, which cannot have a globalist or regionalist algorithm that can be programmed into a robot, nor can AI compete with human abilities and judgment in this domain. *Here “Emotional disorders” refers to disorders of emotional expressions and recognition. 展开更多
关键词 M.A.R.I.E. UNIVERSALITY Idiosyncrasy measurement of Emotional Quotient Emotional Fingerprint Emotional Decision-Making Limbic Lobe
下载PDF
Values of macular ganglion cell-inner plexiform layer and 10-2 visual field measurements in detecting and evaluating glaucoma
2
作者 Hai-Jian Hu Ping Li +7 位作者 Bin Tong Yu-Lian Pang Hong-Dou Luo Fei-Fei Wang Chan Xiong Yu-Lin Yu Hai He Xu Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第5期852-860,共9页
AIM:To assess the performance of macular ganglion cell-inner plexiform layer thickness(mGCIPLT)and 10-2 visual field(VF)parameters in detecting early glaucoma and evaluating the severity of advanced glaucoma.METHODS:T... AIM:To assess the performance of macular ganglion cell-inner plexiform layer thickness(mGCIPLT)and 10-2 visual field(VF)parameters in detecting early glaucoma and evaluating the severity of advanced glaucoma.METHODS:Totally 127 eyes from 89 participants(36 eyes of 19 healthy participants,45 eyes of 31 early glaucoma patients and 46 eyes of 39 advanced glaucoma patients)were included.The relationships between the optical coherence tomography(OCT)-derived parameters and VF sensitivity were determined.Patients with early glaucoma were divided into eyes with or without central 10°of the VF damages(CVFDs),and the diagnostic performances of OCT-derived parameters were assessed.RESULTS:In early glaucoma,the mGCIPLT was significantly correlated with 10-2 VF pattern standard deviation(PSD;with average mGCIPLT:β=-0.046,95%CI,-0.067 to-0.024,P<0.001).In advanced glaucoma,the mGCIPLT was related to the 24-2 VF mean deviation(MD;with average mGCIPLT:β=0.397,95%CI,0.199 to 0.595,P<0.001),10-2 VF MD(with average mGCIPLT:β=0.762,95%CI,0.485 to 1.038,P<0.001)and 24-2 VF PSD(with average mGCIPLT:β=0.244,95%CI,0.124 to 0.364,P<0.001).Except for the minimum and superotemporal mGCIPLT,the decrease of mGCIPLT in early glaucomatous eyes with CVFDs was more severe than that of early glaucomatous eyes without CVFDs.The area under the curve(AUC)of the average mGCIPLT(AUC=0.949,95%CI,0.868 to 0.982)was greater than that of the average circumpapillary retinal nerve fiber layer thickness(cpRNFLT;AUC=0.827,95%CI,0.674 to 0.918)and rim area(AUC=0.799,95%CI,0.610 to 0.907)in early glaucomatous eyes with CVFDs versus normal eyes.CONCLUSION:The 10-2 VF and mGCIPLT parameters are complementary to 24-2 VF,cpRNFLT and ONH parameters,especially in detecting early glaucoma with CVFDs and evaluating the severity of advanced glaucoma in group level. 展开更多
关键词 10-2 visual field ganglion cell-inner plexiform layer retinal nerve fiber layer thickness GLAUCOMA
下载PDF
Measurement Analysis and Evaluation of Twenty-Five Years of Mathematics Education Research in China:Visual Econometric Analysis Based on CiteSpace Knowledge Mapping(1999-2024)
3
作者 Jie Wang Songlin Qi 《Journal of Contemporary Educational Research》 2024年第5期128-140,共13页
Since the new century,China’s mathematics curriculum reform in basic education has continued to move forward in attempts and explorations,presenting many new changes,trends,movements,and developments.Sorting out,anal... Since the new century,China’s mathematics curriculum reform in basic education has continued to move forward in attempts and explorations,presenting many new changes,trends,movements,and developments.Sorting out,analyzing,and summarizing the achievements,experiences,problems,and challenges in this journey are conducive to providing insights for the reform and development of the Chinese basic education mathematics curriculum in the new era.This paper analyses the research on mathematics education in China(1999-2024)using the visual measurement of CiteSpace knowledge mapping,hoping to provide directions for the future of mathematics education in China. 展开更多
关键词 Mathematics education visual econometric analysis CITESPACE
下载PDF
Measurement Analysis and Evaluation of Twenty- Five Years of Chinese Mathematics Textbooks: Visual Analysis Based on CiteSpace Knowledge Graph (1999-2024)
4
作者 Jie Wang 《Journal of Contemporary Educational Research》 2024年第6期243-254,共12页
At present,textbooks based on core literacy have become the inevitable demands of China’s curriculum reform,and the literacy of textbook goal construction is the key to the implementation of core literacy requirement... At present,textbooks based on core literacy have become the inevitable demands of China’s curriculum reform,and the literacy of textbook goal construction is the key to the implementation of core literacy requirements,which is a huge challenge for textbook compilers.In this paper,we use the visual metrology of the CiteSpace knowledge graph to analyze Chinese mathematics textbooks(1999-2024),hoping to guide the future direction of Chinese mathematics textbook research. 展开更多
关键词 visualization Mathematics textbooks Future outlook Keywords clustering Time zone
下载PDF
Visual Modflow在和田县农业经济新区地下水资源评价中的应用 被引量:1
5
作者 杭辉 苏前龙 《陕西水利》 2024年第3期27-30,共4页
为全面了解地下水系统受各种激励因素影响后的水动力场和地下水量变化规律,以及为当地地下水资源开发与利用提供科学的指导意见,本次在和田县农业经济新区地下水资源评价中采用可视化标准软件Visnal Modflow实现地下水资源的模拟与预报... 为全面了解地下水系统受各种激励因素影响后的水动力场和地下水量变化规律,以及为当地地下水资源开发与利用提供科学的指导意见,本次在和田县农业经济新区地下水资源评价中采用可视化标准软件Visnal Modflow实现地下水资源的模拟与预报,通过构建三维非稳定流数值模型,使用迭代方法求解,并根据设计开采量对地下水水位变动做出预测,再基于建模预测结果,结合经济新区地下水资源量确定合理的地下水开采量。 展开更多
关键词 visual Modflow 数值模拟 概念模型
下载PDF
Visual Semantic Segmentation Based on Few/Zero-Shot Learning:An Overview 被引量:2
6
作者 Wenqi Ren Yang Tang +2 位作者 Qiyu Sun Chaoqiang Zhao Qing-Long Han 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2024年第5期1106-1126,共21页
Visual semantic segmentation aims at separating a visual sample into diverse blocks with specific semantic attributes and identifying the category for each block,and it plays a crucial role in environmental perception... Visual semantic segmentation aims at separating a visual sample into diverse blocks with specific semantic attributes and identifying the category for each block,and it plays a crucial role in environmental perception.Conventional learning-based visual semantic segmentation approaches count heavily on largescale training data with dense annotations and consistently fail to estimate accurate semantic labels for unseen categories.This obstruction spurs a craze for studying visual semantic segmentation with the assistance of few/zero-shot learning.The emergence and rapid progress of few/zero-shot visual semantic segmentation make it possible to learn unseen categories from a few labeled or even zero-labeled samples,which advances the extension to practical applications.Therefore,this paper focuses on the recently published few/zero-shot visual semantic segmentation methods varying from 2D to 3D space and explores the commonalities and discrepancies of technical settlements under different segmentation circumstances.Specifically,the preliminaries on few/zeroshot visual semantic segmentation,including the problem definitions,typical datasets,and technical remedies,are briefly reviewed and discussed.Moreover,three typical instantiations are involved to uncover the interactions of few/zero-shot learning with visual semantic segmentation,including image semantic segmentation,video object segmentation,and 3D segmentation.Finally,the future challenges of few/zero-shot visual semantic segmentation are discussed. 展开更多
关键词 visual SEGMENTATION SEPARATING
下载PDF
Heterogeneous Image Knowledge Driven Visual Perception 被引量:1
7
作者 Lan Yan Wenbo Zheng Fei-Yue Wang 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2024年第1期255-257,共3页
Dear Editor,This letter is concerned with visual perception closely related to heterogeneous images.Facing the huge challenge brought by different image modalities,we propose a visual perception framework based on het... Dear Editor,This letter is concerned with visual perception closely related to heterogeneous images.Facing the huge challenge brought by different image modalities,we propose a visual perception framework based on heterogeneous image knowledge,i.e.,the domain knowledge associated with specific vision tasks,to better address the corresponding visual perception problems. 展开更多
关键词 visual visual KNOWLEDGE
下载PDF
集成PHAST-Visual Studio的岩溶区燃气管道灾害后果定量分析及应用
8
作者 李乔楚 陈军华 《科学技术与工程》 北大核心 2024年第12期5239-5248,共10页
为科学评估岩溶区燃气管道灾害的后果影响程度,基于管道失效特征确定喷射火和蒸气云爆炸两种典型后果模式,研判适用于岩溶区燃气管道灾害的热辐射和冲击波超压危害准则,从危害面积、伤亡人数、经济损失、环境破坏4个维度提出岩溶区燃气... 为科学评估岩溶区燃气管道灾害的后果影响程度,基于管道失效特征确定喷射火和蒸气云爆炸两种典型后果模式,研判适用于岩溶区燃气管道灾害的热辐射和冲击波超压危害准则,从危害面积、伤亡人数、经济损失、环境破坏4个维度提出岩溶区燃气管道灾害后果严重程度的评估模型体系,并结合Visual Studio平台开发“岩溶区燃气管道灾害后果分析软件”。立足岩溶区实际工程案例,结合区域经济社会发展、岩溶自然地质以及燃气管道工程特征,基于PHAST软件仿真分析灾害后果的影响范围,结合危害准则对区内人员、物体提出针对性灾害风险管控措施,并通过引入政府、行业、企业等颁布的标准条例,量化得出灾害后果的影响程度。结果表明:提出的PHAST-Visual Studio集成方法能够弥补以往研究的评估主观性问题,将社会科学思想带入工程风险评价研究,并通过计算机软件编程提高灾害后果分析效率,从而有助于显著控制岩溶区燃气管道灾害后果水平。 展开更多
关键词 PHAST仿真 visual Studio 岩溶区 燃气管道 灾害后果 定量分析
下载PDF
Prevalence of visual impairment and estimation of refractive errors among school children in Kakamega,Kenya 被引量:1
9
作者 Isabel Signes-Soler Alfred Ragot +2 位作者 Sheilah Nangena Andrew Wekesa Raúl Montalbán Llamusí 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第5期932-939,共8页
AIM:To investigate the prevalence of visual impairment(VI)and provide an estimation of uncorrected refractive errors in school-aged children,conducted by optometry students as a community service.METHODS:The study was... AIM:To investigate the prevalence of visual impairment(VI)and provide an estimation of uncorrected refractive errors in school-aged children,conducted by optometry students as a community service.METHODS:The study was cross-sectional.Totally 3343 participants were included in the study.The initial examination involved assessing the uncorrected distance visual acuity(UDVA)and visual acuity(VA)while using a+2.00 D lens.The inclusion criteria for a subsequent comprehensive cycloplegic eye examination,performed by an optometrist,were as follows:a UDVA<0.6 decimal(0.20 logMAR)and/or a VA with+2.00 D≥0.8 decimal(0.96 logMAR).RESULTS:The sample had a mean age of 10.92±2.13y(range 4 to 17y),and 51.3%of the children were female(n=1715).The majority of the children(89.7%)fell within the age range of 8 to 14y.Among the ethnic groups,the highest representation was from the Luhya group(60.6%)followed by Luo(20.4%).Mean logMAR UDVA choosing the best eye for each student was 0.29±0.17(range 1.70 to 0.22).Out of the total,246 participants(7.4%)had a full eye examination.The estimated prevalence of myopia(defined as spherical equivalent≤-0.5 D)was found to be 1.45%of the total sample.While around 0.18%of the total sample had hyperopia value exceeding+1.75 D.Refractive astigmatism(cil<-0.75 D)was found in 0.21%(7/3343)of the children.The VI prevalence was 1.26%of the total sample.Among our cases of VI,76.2%could be attributed to uncorrected refractive error.Amblyopia was detected in 0.66%(22/3343)of the screened children.There was no statistically significant correlation observed between age or gender and refractive values.CONCLUSION:The primary cause of VI is determined to be uncorrected refractive errors,with myopia being the most prevalent refractive error observed.These findings underscore the significance of early identification and correction of refractive errors in school-aged children as a means to alleviate the impact of VI. 展开更多
关键词 visual impairment refractive errors MYOPIA AMBLYOPIA sustainable development goals
下载PDF
Improved calibration method for displacement transformation coefficient in optical and visual measurements
10
作者 Haopeng Li Zurong Qiu 《Nanotechnology and Precision Engineering》 CAS CSCD 2023年第1期12-25,共14页
Optical and visual measurement technology is used widely in fields that involve geometric measurements,and among such technology are laser and vision-based displacement measuring modules(LVDMMs).The displacement trans... Optical and visual measurement technology is used widely in fields that involve geometric measurements,and among such technology are laser and vision-based displacement measuring modules(LVDMMs).The displacement transformation coefficient(DTC)of an LVDMM changes with the coordinates in the camera image coordinate system during the displacement measuring process,and these changes affect the displacement measurement accuracy of LVDMMs in the full field of view(FFOV).To give LVDMMs higher accuracy in the FFOV and make them adaptable to widely varying measurement demands,a new calibration method is proposed to improve the displacement measurement accuracy of LVDMMs in the FFOV.First,an image coordinate system,a pixel measurement coordinate system,and a displacement measurement coordinate system are established on the laser receiving screen of the LVDMM.In addition,marker spots in the FFOV are selected,and the DTCs at the marker spots are obtained from calibration experiments.Also,a fitting method based on locally weighted scatterplot smoothing(LOWESS)is selected,and with this fitting method the distribution functions of the DTCs in the FFOV are obtained based on the DTCs at the marker spots.Finally,the calibrated distribution functions of the DTCs are applied to the LVDMM,and experiments conducted to verify the displacement measurement accuracies are reported.The results show that the FFOV measurement accuracies for horizontal and vertical displacements are better than±15μm and±19μm,respectively,and that for oblique displacement is better than±24μm.Compared with the traditional calibration method,the displacement measurement error in the FFOV is now 90%smaller.This research on an improved calibration method has certain significance for improving the measurement accuracy of LVDMMs in the FFOV,and it provides a new method and idea for other vision-based fields in which camera parameters must be calibrated. 展开更多
关键词 Displacement transformation coefficient(DTC) Laser and vision-based displacement measuring module(LVDMM) Displacement measurement Locally weighted scatterplot smoothing(LOWESS) Calibration method
下载PDF
Evaluation of Arterial Signal Coordination with Commercial Connected Vehicle Data: Empirical Traffic Flow Visualization and Performance Measurement
11
作者 Shoaib Mahmud Christopher M. Day 《Journal of Transportation Technologies》 2023年第3期327-352,共26页
Emerging connected vehicle (CV) data sets have recently become commercially available, enabling analysts to develop a variety of powerful performance measures without deploying any field infrastructure. This paper pre... Emerging connected vehicle (CV) data sets have recently become commercially available, enabling analysts to develop a variety of powerful performance measures without deploying any field infrastructure. This paper presents several tools using CV data to evaluate traffic progression quality along a signalized corridor. These include both performance measures for high-level analysis as well as visualizations to examine details of the coordinated operation. With the use of CV data, it is possible to assess not only the movement of traffic on the corridor but also to consider its origin-destination (O-D) path through the corridor. Results for the real-world operation of an eight-intersection signalized arterial are presented. A series of high-level performance measures are used to evaluate overall performance by time of day, with differing results by metric. Next, the details of the operation are examined with the use of two visualization tools: a cyclic time-space diagram (TSD) and an empirical platoon progression diagram (PPD). Comparing flow visualizations developed with different included O-D paths reveals several features, such as the presence of secondary and tertiary platoons on certain sections that cannot be seen when only end-to-end journeys are included. In addition, speed heat maps are generated, providing both speed performance along the corridor and locations and the extent of the queue. The proposed visualization tools portray the corridor’s performance holistically instead of combining individual signal performance metrics. The techniques exhibited in this study are compelling for identifying locations where engineering solutions such as access management or timing plan change are required. The recent progress in infrastructure-free sensing technology has significantly increased the scope of CV data-based traffic management systems, enhancing the significance of this study. The study demonstrates the utility of CV trajectory data for obtaining high-level details of the corridor performance as well as drilling down into the minute specifics. 展开更多
关键词 Traffic Signal Performance Measures Vehicle Trajectory Data Connected Vehicle Data
下载PDF
Morphological disruption and visual tuning alterations in the primary visual cortex in glaucoma(DBA/2J)mice 被引量:1
12
作者 Yin Yang Zhaoxi Yang +9 位作者 Maoxia Lv Ang Jia Junjun Li Baitao Liao Jing’an Chen Zhengzheng Wu Yi Shi Yang Xia Dezhong Yao Ke Chen 《Neural Regeneration Research》 SCIE CAS CSCD 2024年第1期220-225,共6页
Glaucoma is a leading cause of irreve rsible blindness wo rldwide,and previous studies have shown that,in addition to affecting the eyes,it also causes abnormalities in the brain.However,it is not yet clear how the pr... Glaucoma is a leading cause of irreve rsible blindness wo rldwide,and previous studies have shown that,in addition to affecting the eyes,it also causes abnormalities in the brain.However,it is not yet clear how the primary visual cortex(V1)is altered in glaucoma.This study used DBA/2J mice as a model for spontaneous secondary glaucoma.The aim of the study was to compare the electrophysiological and histomorphological chara cteristics of neurons in the V1between 9-month-old DBA/2J mice and age-matched C57BL/6J mice.We conducted single-unit recordings in the V1 of light-anesthetized mice to measure the visually induced responses,including single-unit spiking and gamma band oscillations.The morphology of layerⅡ/Ⅲneurons was determined by neuronal nuclear antigen staining and Nissl staining of brain tissue sections.Eighty-seven neurons from eight DBA/2J mice and eighty-one neurons from eight C57BL/6J mice were examined.Compared with the C57BL/6J group,V1 neurons in the DBA/2J group exhibited weaker visual tuning and impaired spatial summation.Moreove r,fewer neuro ns were observed in the V1 of DBA/2J mice compared with C57BL/6J mice.These findings suggest that DBA/2J mice have fewer neurons in the VI compared with C57BL/6J mice,and that these neurons have impaired visual tuning.Our findings provide a better understanding of the pathological changes that occur in V1 neuron function and morphology in the DBA/2J mouse model.This study might offer some innovative perspectives regarding the treatment of glaucoma. 展开更多
关键词 DBA/2J DEGENERATION gamma band oscillations GLAUCOMA primary visual cortex(V1) RETINA single-unit recording tuning curve
下载PDF
Bioactive material promotes longdistance regeneration of optic nerve to restore visual functions
13
作者 Kai Liu 《Neural Regeneration Research》 SCIE CAS CSCD 2024年第1期160-160,共1页
Visual system is vital to human beings.Unfortunately,the optic nerve lacks the ability to regenerate after injury.Therefo re,long-distance regeneration of the optic nerve is a major unsolved medical problem in the wor... Visual system is vital to human beings.Unfortunately,the optic nerve lacks the ability to regenerate after injury.Therefo re,long-distance regeneration of the optic nerve is a major unsolved medical problem in the world(Laha et al.,2017).Recently,Li and So groups' study showed that the bioactive material(ciliary neurotrophic factor[CNTF]-chitosan) could promote long-distance regeneration of the completely transected optic nerve in adult rats and partially restored the visual functions(Liu et al.,2023).This study sheds light on the clinical potential for repairing the severely injured optic nerve. 展开更多
关键词 visual visual FUNCTIONS
下载PDF
Bunch-length measurement at a bunch-by-bunch rate based on time–frequency-domain joint analysis techniques and its application
14
作者 Hong-Shuang Wang Xing Yang +2 位作者 Yong-Bin Leng Yi-Mei Zhou Ji-Gang Wang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第4期165-175,共11页
This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch si... This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch signal to obtain bunch-by-bunch and turn-by-turn longitudinal parameters,such as bunch length and synchronous phase.The bunch signal is obtained using a button electrode with a bandwidth of several gigahertz.The data acquisition device was a high-speed digital oscilloscope with a sampling rate of more than 10 GS/s,and the single-shot sampling data buffer covered thousands of turns.The bunch-length and synchronous phase information were extracted via offline calculations using Python scripts.The calibration coefficient of the system was determined using a commercial streak camera.Moreover,this technique was tested on two different storage rings and successfully captured various longitudinal transient processes during the harmonic cavity debugging process at the Shanghai Synchrotron Radiation Facility(SSRF),and longitudinal instabilities were observed during the single-bunch accumulation process at Hefei Light Source(HLS).For Gaussian-distribution bunches,the uncertainty of the bunch phase obtained using this technique was better than 0.2 ps,and the bunch-length uncertainty was better than 1 ps.The dynamic range exceeded 10 ms.This technology is a powerful and versatile beam diagnostic tool that can be conveniently deployed in high-energy electron storage rings. 展开更多
关键词 Bunch-by-bunch diagnostic Bunch-length measurement Synchronous phase measurement Joint time–frequency-domain analysis Longitudinal instability
下载PDF
Effect of capsule treatment on visual acuity and quality after phacoemulsification lens implantation in myopic patients with cataract
15
作者 Wei Liu Qi Liu +2 位作者 Fang Zhou Bo Feng Wan-Ling Wu 《World Journal of Clinical Cases》 SCIE 2024年第19期3882-3889,共8页
BACKGROUND Cataracts pose a significant clinical burden due to their complex pathogenesis.In recent years,an increase in cataracts coexisting with myopia has heightened the incidence of retinopathy and posterior vitre... BACKGROUND Cataracts pose a significant clinical burden due to their complex pathogenesis.In recent years,an increase in cataracts coexisting with myopia has heightened the incidence of retinopathy and posterior vitreous detachment.Additionally,symptoms of ocular axis elongation,lens nucleus hardening,and vitreous liquefaction have become more prevalent.While conventional extracapsular cataract extraction is commonly employed,it often yields suboptimal visual outcomes.Subsequent advancements in cataract phacoemulsification and lens implantation surgeries have gained widespread acceptance for their ability to improve refraction and significantly improve uncorrected visual acuity.AIM To investigate the effect of capsular treatment after phacoemulsification lens implantation in myopic patients with cataract.METHODS We selected 110 patients(with 134 eyes)with myopia and cataracts treated.These patients were categorized into two groups:an observation group(57 patients with 70 eyes)and a control group(53 patients with 64 eyes).The control group underwent cataract phacoemulsification and lens implantation,while the observation group received a refined capsular treatment based on the control group’s procedure.We assessed the differences in visual acuity and quality between the two groups before and after surgery.RESULTS At six months post-operation,the observation group exhibited significantly improved far vision,intermediate vision,near vision,lower objective scattering index,higher Modulation transfer function cut-off frequency,and overall vision metrics at different contrast levels(100%,20%and 9%)compared to the control group(P<0.05).The total score of the National Eye Institute Visual Function Questionnaire in the observation group at 6 months after operation was significantly higher than that in the control group(P<0.05).No significant difference in the incidence of adverse reactions was observed between the observation group and control group(P>0.05).CONCLUSION Capsular treatment demonstrates efficacy in improving visual acuity and quality after phacoemulsification lens implantation in myopic patients with cataracts,warranting its clinical application. 展开更多
关键词 Capsular treatment MYOPIA CATARACT Phacoemulsification and lens implantation visual acuity visual quality Uncorrected visual acuity
下载PDF
A New Device for Gas-Liquid Flow Measurements Relying on Forced Annular Flow
16
作者 Tiantian Yu Youping Lv +5 位作者 Hao Zhong Ming Liu Pingyuan Gai Zeju Jiang Peng Zhang Xingkai Zhang 《Fluid Dynamics & Materials Processing》 EI 2024年第8期1759-1772,共14页
A new measurement device,consisting of swirling blades and capsule-shaped throttling elements,is proposed in this study to eliminate typical measurement errors caused by complex flow patterns in gas-liquid flow.The sw... A new measurement device,consisting of swirling blades and capsule-shaped throttling elements,is proposed in this study to eliminate typical measurement errors caused by complex flow patterns in gas-liquid flow.The swirling blades are used to transform the complex flow pattern into a forced annular flow.Drawing on the research of existing blockage flow meters and also exploiting the single-phase flow measurement theory,a formula is introduced to measure the phase-separated flow of gas and liquid.The formula requires the pressure ratio,Lockhart-Martinelli number(L-M number),and the gas phase Froude number.The unknown parameters appearing in the formula are fitted through numerical simulation using computational fluid dynamics(CFD),which involves a comprehensive analysis of the flow field inside the device from multiple perspectives,and takes into account the influence of pressure fluctuations.Finally,the measurement model is validated through an experimental error analysis.The results demonstrate that the measurement error can be maintained within±8%for various flow patterns,including stratified flow,bubble flow,and wave flow. 展开更多
关键词 Gas-liquid flow measurement blocking flowmeter measurement model pressure fluctuations numerical simulation experimental control
下载PDF
RMPC-Based Visual Servoing for Trajectory Tracking of Quadrotor UAVs With Visibility Constraints
17
作者 Qifan Yang Huiping Li 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2024年第9期2027-2029,共3页
Dear Editor,This letter deals with the tracking problem of quadrotors subject to external disturbances and visibility constraints by designing a robust model predictive control(RMPC) scheme. According to the imagebase... Dear Editor,This letter deals with the tracking problem of quadrotors subject to external disturbances and visibility constraints by designing a robust model predictive control(RMPC) scheme. According to the imagebased visual servoing(IBVS) method, a virtual camera is constructed to express image moments of the tracking target. 展开更多
关键词 visual IMAGE VISIBILITY
下载PDF
Women in visual neural regeneration research
18
作者 Tonia S.Rex David J.Calkins 《Neural Regeneration Research》 SCIE CAS 2025年第2期489-490,共2页
The year 2024 marks the 60^(th)anniversary of Title IX and 25 years since the New York Times revealed bias against female faculty members at the Massachusetts Institute of Technology.We take an opportunity here to exa... The year 2024 marks the 60^(th)anniversary of Title IX and 25 years since the New York Times revealed bias against female faculty members at the Massachusetts Institute of Technology.We take an opportunity here to examine the state of gender bias in a relatively new yet already prominent field,neural regeneration in the visual system,for which there is a well-defined context useful for this purpose.The National Eye Institute(NEI)provided the first round of research funding for its Audacious Goals Initiative(AGI)on visual neural regeneration in 2013 and the last round in 2021.Therefore,we focus on this timespan.Data sources included PubMed,the National Science Foundation(NSF),the NEI,the Blue Ridge Institute for Medical Research and data from the major professional organization for eye and vision research,the Association for Research in Vision and Ophthalmology(ARVO). 展开更多
关键词 NEURAL visual TIMES
下载PDF
A New Perspective in the Study of Medical History through Visuals
19
作者 ZHANG Shujian 《Chinese Medicine and Culture》 2024年第3期183-184,共2页
In pre-modern cultural history,both textual and visual documentation played crucial roles,each possessing its own narrative logic.Historically,text has been a dominant medium for cultural documentation,whereas images,... In pre-modern cultural history,both textual and visual documentation played crucial roles,each possessing its own narrative logic.Historically,text has been a dominant medium for cultural documentation,whereas images,which predate text,have often been undervalued. 展开更多
关键词 visual HISTORY visual
下载PDF
Enhancing Energy Efficiency with a Dynamic Trust Measurement Scheme in Power Distribution Network
20
作者 Yilei Wang Xin Sun +4 位作者 Guiping Zheng Ahmar Rashid Sami Ullah Hisham Alasmary Muhammad Waqas 《Computers, Materials & Continua》 SCIE EI 2024年第3期3909-3927,共19页
The application of Intelligent Internet of Things(IIoT)in constructing distribution station areas strongly supports platform transformation,upgrade,and intelligent integration.The sensing layer of IIoT comprises the e... The application of Intelligent Internet of Things(IIoT)in constructing distribution station areas strongly supports platform transformation,upgrade,and intelligent integration.The sensing layer of IIoT comprises the edge convergence layer and the end sensing layer,with the former using intelligent fusion terminals for real-time data collection and processing.However,the influx of multiple low-voltage in the smart grid raises higher demands for the performance,energy efficiency,and response speed of the substation fusion terminals.Simultaneously,it brings significant security risks to the entire distribution substation,posing a major challenge to the smart grid.In response to these challenges,a proposed dynamic and energy-efficient trust measurement scheme for smart grids aims to address these issues.The scheme begins by establishing a hierarchical trust measurement model,elucidating the trust relationships among smart IoT terminals.It then incorporates multidimensional measurement factors,encompassing static environmental factors,dynamic behaviors,and energy states.This comprehensive approach reduces the impact of subjective factors on trust measurements.Additionally,the scheme incorporates a detection process designed for identifying malicious low-voltage end sensing units,ensuring the prompt identification and elimination of any malicious terminals.This,in turn,enhances the security and reliability of the smart grid environment.The effectiveness of the proposed scheme in pinpointing malicious nodes has been demonstrated through simulation experiments.Notably,the scheme outperforms established trust metric models in terms of energy efficiency,showcasing its significant contribution to the field. 展开更多
关键词 IIoT trusted measure energy efficient
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部