The key to the wavelet based denoising teehniquea is how to manipulate the wavelet coefficients. By referring to the idea of Inclusive-OR in the design of circuits, this paper proposes a new algorithm called wavelet d...The key to the wavelet based denoising teehniquea is how to manipulate the wavelet coefficients. By referring to the idea of Inclusive-OR in the design of circuits, this paper proposes a new algorithm called wavelet domain Inclusive-OR denoising algorithm(WDIDA), which distinguishes the wavelet coefficients belonging to image or noise by considering their phases and modulus maxima simultaneously. Using this new algorithm, the denoising effects are improved and the computation time is reduced. Furthermore, in order to enhance the edges of the image but not magnify noise, a contrast nonlinear enhancing algorithm is presented according to human visual properties. Compared with traditional enhancing algorithms, the algorithm that we proposed has a better noise reducing performanee , preserving edges and improving the visual quality of images.展开更多
AIM:To compare the corneal biomechanical properties difference by ocular response analyzer(ORA) in normal tension glaucoma(NTG) patients with different visual field(VF) progression speed. METHODS:NTG patients ...AIM:To compare the corneal biomechanical properties difference by ocular response analyzer(ORA) in normal tension glaucoma(NTG) patients with different visual field(VF) progression speed. METHODS:NTG patients with well-controlled Goldmann applanation tonometer(GAT) who routinely consulted Kitasato University Hospital Glaucoma Department between January 2010 and February 2014 were enrolled.GAT and ORA parameters including corneal compensated intraocular pressure(lOPcc),Goldmann estimated intraocular pressure(lOPg),corneal hysteresis(CH),corneal resistance factor(CRF) were recorded.VF was tested by Swedish interactive threshold algorithm(SITA)-standard 30-2 fields.All patients underwent VF measurement regularly and GAT did not exceed 15 mm Hg at any time during the 3y follow up.Patients were divided into four groups according to VF change over 3y,and ORA findings were compared between the upper 25th percentile group(slow progression group) and the lower 25th percentile group(rapid progression group).RESULTS:Eighty-two eyes of 56 patients were studied.There were 21 eyes(21 patients) each in rapid and slow progression groups respectively.GAT,lOPcc,lOPg,CH,CRF were 12.1+1.4 mm Hg,15.8±1.8 mm Hg,12.8±2.0 mm Hg,8.4±1.1 mm Hg,7.9±1.3 mm Hg respectively in rapid progression group and 11.5±1.3 mm Hg,13.5±2.1 mm Hg,11.2±1.6 mm Hg,9.3±1.1 mm Hg,8.2±0.9 mm Hg respectively in slow progression group(P=0.214,〈0.001,0.007,0.017,0.413,respectively).In bivariate correlation analysis,lOPcc,lOPcc-GAT and CH were significant correlated with m△MD(r =-0.292,-0.312,0.228 respectively,P =0.008,0.004,0.039 respectively).CONCLUSION:Relatively rapid VF progression occurred in NTG patients whose lOPcc are rather high,CH are rather low and the difference between lOPcc and GAT are relatively large.Higher lOPcc and lower CH are associated with VF progression in NTG patients.This study suggests that GAT measures might underestimate the IOP in such patients.展开更多
文摘The key to the wavelet based denoising teehniquea is how to manipulate the wavelet coefficients. By referring to the idea of Inclusive-OR in the design of circuits, this paper proposes a new algorithm called wavelet domain Inclusive-OR denoising algorithm(WDIDA), which distinguishes the wavelet coefficients belonging to image or noise by considering their phases and modulus maxima simultaneously. Using this new algorithm, the denoising effects are improved and the computation time is reduced. Furthermore, in order to enhance the edges of the image but not magnify noise, a contrast nonlinear enhancing algorithm is presented according to human visual properties. Compared with traditional enhancing algorithms, the algorithm that we proposed has a better noise reducing performanee , preserving edges and improving the visual quality of images.
文摘AIM:To compare the corneal biomechanical properties difference by ocular response analyzer(ORA) in normal tension glaucoma(NTG) patients with different visual field(VF) progression speed. METHODS:NTG patients with well-controlled Goldmann applanation tonometer(GAT) who routinely consulted Kitasato University Hospital Glaucoma Department between January 2010 and February 2014 were enrolled.GAT and ORA parameters including corneal compensated intraocular pressure(lOPcc),Goldmann estimated intraocular pressure(lOPg),corneal hysteresis(CH),corneal resistance factor(CRF) were recorded.VF was tested by Swedish interactive threshold algorithm(SITA)-standard 30-2 fields.All patients underwent VF measurement regularly and GAT did not exceed 15 mm Hg at any time during the 3y follow up.Patients were divided into four groups according to VF change over 3y,and ORA findings were compared between the upper 25th percentile group(slow progression group) and the lower 25th percentile group(rapid progression group).RESULTS:Eighty-two eyes of 56 patients were studied.There were 21 eyes(21 patients) each in rapid and slow progression groups respectively.GAT,lOPcc,lOPg,CH,CRF were 12.1+1.4 mm Hg,15.8±1.8 mm Hg,12.8±2.0 mm Hg,8.4±1.1 mm Hg,7.9±1.3 mm Hg respectively in rapid progression group and 11.5±1.3 mm Hg,13.5±2.1 mm Hg,11.2±1.6 mm Hg,9.3±1.1 mm Hg,8.2±0.9 mm Hg respectively in slow progression group(P=0.214,〈0.001,0.007,0.017,0.413,respectively).In bivariate correlation analysis,lOPcc,lOPcc-GAT and CH were significant correlated with m△MD(r =-0.292,-0.312,0.228 respectively,P =0.008,0.004,0.039 respectively).CONCLUSION:Relatively rapid VF progression occurred in NTG patients whose lOPcc are rather high,CH are rather low and the difference between lOPcc and GAT are relatively large.Higher lOPcc and lower CH are associated with VF progression in NTG patients.This study suggests that GAT measures might underestimate the IOP in such patients.