Objective:To study the potential role of subjective visual vertical(SVV)as a prognostic marker for canalith repositioning maneuver(CRM)in patients with posterior canal benign paroxysmal positional vertigo(PC-BPPV)for ...Objective:To study the potential role of subjective visual vertical(SVV)as a prognostic marker for canalith repositioning maneuver(CRM)in patients with posterior canal benign paroxysmal positional vertigo(PC-BPPV)for the Indian population.Methods:SVV was examined in 30 patients with PC-BPPV before and after canalith repositioning maneuver and after complete resolution of PC-BPPV.Study parameters included the mean of 10 angular tilt readings and direction of deviation,which were compared before and after CRM and following complete resolution of PC-BPPV.Results:The angle of SVV tilt was greater and deviated towards the affected ear before CRM in all patients,which decreased significantly shortly after CRM and continued to decrease after complete resolution of PC-BPPV(p<0.0001).Conclusions:SVV can be used to test utricular dysfunction in PC-BPPV.The angle of tilt improves in response to CRM,which may be used as a prognostic marker in patients with PC-BPPV receiving CRM.展开更多
Objective To study the value of the subjective visual vertical(SVV)in the diagnosis of vestibular migraine(VM).Methods This study recruited 128 VM patients and 64 age-matched normal subjects.We detected the SVV during...Objective To study the value of the subjective visual vertical(SVV)in the diagnosis of vestibular migraine(VM).Methods This study recruited 128 VM patients and 64 age-matched normal subjects.We detected the SVV during the interval between attacks in both groups,in sitting upright,and the head tilted at 45°to the left or right.We then examined the correlation between the SVV results with the vestibular evoked myogenic potential(VEMP)and canal paresis(CP).Results It was found there was a significant difference in SVV at the upright position between VM patients and normal controls(P=0.006)and no significant difference was found at the tilts of 45°to the left or right between the two groups.The SVV results at the upright position were significantly correlated with cervical VEMP(P=0.042)whereas not significantly correlated with CP and VEMP.There existed no significant difference in the conformity to the Müller effect(M effect)between the two groups.ROC analysis exhibited that the sensitivity,specificity of SVVs at the upright were 67.200%and 62.500%respectively.The diagnostic value of SVV at the upright position was significantly higher than that at tilts of 45°to the left and right(P=0.006).Nonetheless the diagnostic accuracy was relatively low.Conclusion Abnormality in SVV possibly stems from the lasting functional disorder of cerebellar or high-level cortical centers in VM patients or is linked to the vestibular compensation.The SVV is of low diagnostic value for VM and the value of SVV in VM warrants further study.展开更多
Subjective visual vertical(SVV)and subjective visual horizontal(SVH)tests can be used to evaluate the perception of verticality and horizontality,respectively,and can aid the diagnosis of otolith dysfunction in clinic...Subjective visual vertical(SVV)and subjective visual horizontal(SVH)tests can be used to evaluate the perception of verticality and horizontality,respectively,and can aid the diagnosis of otolith dysfunction in clinical practice.In this study,SVV and SVH screen version tests are implemented using virtual reality(VR)equipment;the proposed test method promotes a more immersive feeling for the subject while using a simple equipment configuration and possessing excellent mobility.To verify the performance of the proposed VR-based SVV and SVH tests,a reliable comparison was made between the traditional screen-based SVV and SVH tests and the proposed method,based on 30 healthy subjects.The average results of our experimental tests on the VR-based binocular SVV and SVH equipment were−0.15◦±1.74 and 0.60◦±1.18,respectively.The proposed VR-based method satisfies the normal tolerance for horizontal or vertical lines,i.e.,a±3◦error,as defined in previous studies,and it can be used to replace existing test methods.展开更多
Purpose:.To analyze the retinal symmetry of multifocal visual evoked potential (mfVEP) in both eyes of normal subjects. Methods: The monocular mfVEP in both eyes of 36 normal subjects (72 eyes) were tested with VERIS ...Purpose:.To analyze the retinal symmetry of multifocal visual evoked potential (mfVEP) in both eyes of normal subjects. Methods: The monocular mfVEP in both eyes of 36 normal subjects (72 eyes) were tested with VERIS Science 4.0. The stimulus was the pattern reversal dart array consisted of 60 sectors each including 16 black-white reverse patterns. The visual stimulation was controlled by a binary pseudo-random m-sequence and subtended 25 degrees of retinal region. Results: The mfVEP patterns between left and right eyes of each subject were similar, and P1 latency and amplitude in correspondent visual field quadrants between left and right eyes had no significant difference(P>0.05). The latency of superotemporal visual field quadrant in right eyes was shorter than that of superonasal visual field quadrant in left eyes,and the amplitude of superonasal visual field quadrant in right eyes was longer than that of superotemporal visual field quadrant in left eyes(P<0.05). The P1 latency and amplitude among four visual field quadrants of each eye had significant difference(P<0.05). The P1 latency between the superonasal visual field quadrant and inferotemporal visual field quadrant or between the superonasal visual field quadrant and inferonasal quadrant visual field had significant differences in right or left eyes(P<0.05). Conclusion: The mfVEP of normal subjects exists retinal symmetry.展开更多
Virtual reality(VR) environment can provide immersive experience to viewers.Under the VR environment, providing a good quality of experience is extremely important.Therefore, in this paper, we present an image quality...Virtual reality(VR) environment can provide immersive experience to viewers.Under the VR environment, providing a good quality of experience is extremely important.Therefore, in this paper, we present an image quality assessment(IQA) study on omnidirectional images. We first build an omnidirectional IQA(OIQA) database, including 16 source images with their corresponding 320 distorted images. We add four commonly encountered distortions. These distortions are JPEG compression, JPEG2000 compression, Gaussian blur, and Gaussian noise. Then we conduct a subjective quality evaluation study in the VR environment based on the OIQA database. Considering that visual attention is more important in VR environment, head and eye movement data are also tracked and collected during the quality rating experiments. The 16 raw and their corresponding distorted images,subjective quality assessment scores, and the head-orientation data and eye-gaze data together constitute the OIQA database. Based on the OIQA database, we test some state-of-the-art full-reference IQA(FR-IQA) measures on equirectangular format or cubic formatomnidirectional images. The results show that applying FR-IQA metrics on cubic format omnidirectional images could improve their performance. The performance of some FR-IQA metrics combining the saliency weight of three different types are also tested based on our database. Some new phenomena different from traditional IQA are observed.展开更多
目的老年人群中主观认知下降(Subjective Cognitive Decline,SCD)的研究显著增加。本研究采用文献计量学的方法分析近20年老年人SCD研究的热点和趋势,旨在为研究者开展该领域的研究提供参考。方法本研究选择Web of Science核心合集中200...目的老年人群中主观认知下降(Subjective Cognitive Decline,SCD)的研究显著增加。本研究采用文献计量学的方法分析近20年老年人SCD研究的热点和趋势,旨在为研究者开展该领域的研究提供参考。方法本研究选择Web of Science核心合集中2003年至2023年发表的关于老年人SCD的研究,初步检索获得1502篇,最终纳入1436篇。采用CiteSpace软件对国家、机构、作者、期刊、关键词和突现词等进行分析。结果老年人SCD研究整体呈现上升趋势。美国在该研究领域占据主导地位,其次为中国和法国;加州大学系统、法国国家健康与医学研究院及UDICE法国研究型大学联盟是发文量处于前3位的研究机构;Frank Jessen、韩瑛和Kathryn Ellis是发文量处于前3位的研究者;被引频次处于前3位的期刊为Neurology、Alzheimers&Dementia、Journal of Alzheimer’s Disease。关键词聚类分析显示关注热点涉及“抑郁”“功能连接”“认知储备”“认知功能”“身体活动”、“痴呆症预防”“行为障碍”“初级保健”和“早期诊断”等;关键词的突现词包括“身体活动”“临床前阿尔茨海默病”“框架”“未来痴呆症”和“老年抑郁症”。结论老年人SCD的研究逐年增长,成为研究者关注的热点,其研究范围和主题也逐渐扩大,重点关注早期筛查和预防、负性情绪及症状管理,可为后期护理研究者开展相关研究提供借鉴和参考。展开更多
目的探讨视听障碍(audio-visual impairments)对主观幸福感(subjective well-being,SWB)的影响,以及抑郁倾向是否中介了视听障碍与主观幸福感之间的关联。方法中国健康与退休纵向调查(The China Health and Retirement Longitudinal Sur...目的探讨视听障碍(audio-visual impairments)对主观幸福感(subjective well-being,SWB)的影响,以及抑郁倾向是否中介了视听障碍与主观幸福感之间的关联。方法中国健康与退休纵向调查(The China Health and Retirement Longitudinal Survey,CHARLS)对45岁及以上的中老年人进行问卷调查,在全国30个省级行政单位中采用多阶段抽样,分别在县(区)-村(居)-家户-个人层面上进行抽样,并在县(区)-村(居)两级抽样中,采用按人口规模成比例的概率(proportional probability sampling,PPS)抽样,最终纳入了28个省份150个县(区)的450个村/社区。本研究基于2018年的CHARLS数据展开研究,纳入标准为:(1)年龄≥60岁;(2)有完整的自我报告的视力和听力状况;(3)至少含有生活满意度、主观期望寿命、自评健康状况3项主观幸福感指标中的一个。CHARLS使用Likert五分量表测定老年人的主观幸福感,使用10项流调中心抑郁自评量表(the Center for Epidemiology Studies Depression Scale-10,CESD-10)测定老年人的抑郁倾向。本研究采用多元回归分析视听障碍与抑郁倾向、主观幸福感之间的关联,并通过中介模型分析抑郁倾向的中介作用。双侧P值<0.05被认为有统计学意义。结果最终纳入符合标准的研究对象7620人。其中有视听障碍的患者抑郁倾向水平明显更高,主观幸福感的三项指标均较低(P值均小于0.05)。视觉障碍、听觉障碍和视听双重障碍与更高的抑郁倾向水平和更低的自评健康、主观期望寿命有关;视觉障碍和视听双重障碍与较低的生活满意度有关。抑郁倾向在视听双重障碍与生活满意度间及视觉障碍、听觉障碍、视听双重障碍与自评健康和主观期望寿命间起部分中介作用。结论在中国老年人群中,视听障碍与较低的主观幸福感状态有关,抑郁倾向在其中起着中介作用。展开更多
文摘Objective:To study the potential role of subjective visual vertical(SVV)as a prognostic marker for canalith repositioning maneuver(CRM)in patients with posterior canal benign paroxysmal positional vertigo(PC-BPPV)for the Indian population.Methods:SVV was examined in 30 patients with PC-BPPV before and after canalith repositioning maneuver and after complete resolution of PC-BPPV.Study parameters included the mean of 10 angular tilt readings and direction of deviation,which were compared before and after CRM and following complete resolution of PC-BPPV.Results:The angle of SVV tilt was greater and deviated towards the affected ear before CRM in all patients,which decreased significantly shortly after CRM and continued to decrease after complete resolution of PC-BPPV(p<0.0001).Conclusions:SVV can be used to test utricular dysfunction in PC-BPPV.The angle of tilt improves in response to CRM,which may be used as a prognostic marker in patients with PC-BPPV receiving CRM.
基金funded by grants from the Shanghai Science and Technology Commission(No.18ZR1439200)the National Natural Science Foundation of China(No.81873701)+1 种基金the Innovation Items in the Military Service Field of Changzheng Hospital(No.2019CZJS102,No.2020CZWJFW10)the National Twelfth Five-Year Research Program of China(No.2012BAI12B02).
文摘Objective To study the value of the subjective visual vertical(SVV)in the diagnosis of vestibular migraine(VM).Methods This study recruited 128 VM patients and 64 age-matched normal subjects.We detected the SVV during the interval between attacks in both groups,in sitting upright,and the head tilted at 45°to the left or right.We then examined the correlation between the SVV results with the vestibular evoked myogenic potential(VEMP)and canal paresis(CP).Results It was found there was a significant difference in SVV at the upright position between VM patients and normal controls(P=0.006)and no significant difference was found at the tilts of 45°to the left or right between the two groups.The SVV results at the upright position were significantly correlated with cervical VEMP(P=0.042)whereas not significantly correlated with CP and VEMP.There existed no significant difference in the conformity to the Müller effect(M effect)between the two groups.ROC analysis exhibited that the sensitivity,specificity of SVVs at the upright were 67.200%and 62.500%respectively.The diagnostic value of SVV at the upright position was significantly higher than that at tilts of 45°to the left and right(P=0.006).Nonetheless the diagnostic accuracy was relatively low.Conclusion Abnormality in SVV possibly stems from the lasting functional disorder of cerebellar or high-level cortical centers in VM patients or is linked to the vestibular compensation.The SVV is of low diagnostic value for VM and the value of SVV in VM warrants further study.
基金supported by the Soonchunhyang University Research Fund and 2018 Ulsan University Hospital Research Grant(UUH-2018-12)(Grantee:JYP,http://www.uuh.ulsan.kr).The authors are grateful for their supports.
文摘Subjective visual vertical(SVV)and subjective visual horizontal(SVH)tests can be used to evaluate the perception of verticality and horizontality,respectively,and can aid the diagnosis of otolith dysfunction in clinical practice.In this study,SVV and SVH screen version tests are implemented using virtual reality(VR)equipment;the proposed test method promotes a more immersive feeling for the subject while using a simple equipment configuration and possessing excellent mobility.To verify the performance of the proposed VR-based SVV and SVH tests,a reliable comparison was made between the traditional screen-based SVV and SVH tests and the proposed method,based on 30 healthy subjects.The average results of our experimental tests on the VR-based binocular SVV and SVH equipment were−0.15◦±1.74 and 0.60◦±1.18,respectively.The proposed VR-based method satisfies the normal tolerance for horizontal or vertical lines,i.e.,a±3◦error,as defined in previous studies,and it can be used to replace existing test methods.
文摘Purpose:.To analyze the retinal symmetry of multifocal visual evoked potential (mfVEP) in both eyes of normal subjects. Methods: The monocular mfVEP in both eyes of 36 normal subjects (72 eyes) were tested with VERIS Science 4.0. The stimulus was the pattern reversal dart array consisted of 60 sectors each including 16 black-white reverse patterns. The visual stimulation was controlled by a binary pseudo-random m-sequence and subtended 25 degrees of retinal region. Results: The mfVEP patterns between left and right eyes of each subject were similar, and P1 latency and amplitude in correspondent visual field quadrants between left and right eyes had no significant difference(P>0.05). The latency of superotemporal visual field quadrant in right eyes was shorter than that of superonasal visual field quadrant in left eyes,and the amplitude of superonasal visual field quadrant in right eyes was longer than that of superotemporal visual field quadrant in left eyes(P<0.05). The P1 latency and amplitude among four visual field quadrants of each eye had significant difference(P<0.05). The P1 latency between the superonasal visual field quadrant and inferotemporal visual field quadrant or between the superonasal visual field quadrant and inferonasal quadrant visual field had significant differences in right or left eyes(P<0.05). Conclusion: The mfVEP of normal subjects exists retinal symmetry.
文摘Virtual reality(VR) environment can provide immersive experience to viewers.Under the VR environment, providing a good quality of experience is extremely important.Therefore, in this paper, we present an image quality assessment(IQA) study on omnidirectional images. We first build an omnidirectional IQA(OIQA) database, including 16 source images with their corresponding 320 distorted images. We add four commonly encountered distortions. These distortions are JPEG compression, JPEG2000 compression, Gaussian blur, and Gaussian noise. Then we conduct a subjective quality evaluation study in the VR environment based on the OIQA database. Considering that visual attention is more important in VR environment, head and eye movement data are also tracked and collected during the quality rating experiments. The 16 raw and their corresponding distorted images,subjective quality assessment scores, and the head-orientation data and eye-gaze data together constitute the OIQA database. Based on the OIQA database, we test some state-of-the-art full-reference IQA(FR-IQA) measures on equirectangular format or cubic formatomnidirectional images. The results show that applying FR-IQA metrics on cubic format omnidirectional images could improve their performance. The performance of some FR-IQA metrics combining the saliency weight of three different types are also tested based on our database. Some new phenomena different from traditional IQA are observed.
文摘目的老年人群中主观认知下降(Subjective Cognitive Decline,SCD)的研究显著增加。本研究采用文献计量学的方法分析近20年老年人SCD研究的热点和趋势,旨在为研究者开展该领域的研究提供参考。方法本研究选择Web of Science核心合集中2003年至2023年发表的关于老年人SCD的研究,初步检索获得1502篇,最终纳入1436篇。采用CiteSpace软件对国家、机构、作者、期刊、关键词和突现词等进行分析。结果老年人SCD研究整体呈现上升趋势。美国在该研究领域占据主导地位,其次为中国和法国;加州大学系统、法国国家健康与医学研究院及UDICE法国研究型大学联盟是发文量处于前3位的研究机构;Frank Jessen、韩瑛和Kathryn Ellis是发文量处于前3位的研究者;被引频次处于前3位的期刊为Neurology、Alzheimers&Dementia、Journal of Alzheimer’s Disease。关键词聚类分析显示关注热点涉及“抑郁”“功能连接”“认知储备”“认知功能”“身体活动”、“痴呆症预防”“行为障碍”“初级保健”和“早期诊断”等;关键词的突现词包括“身体活动”“临床前阿尔茨海默病”“框架”“未来痴呆症”和“老年抑郁症”。结论老年人SCD的研究逐年增长,成为研究者关注的热点,其研究范围和主题也逐渐扩大,重点关注早期筛查和预防、负性情绪及症状管理,可为后期护理研究者开展相关研究提供借鉴和参考。
文摘目的探讨视听障碍(audio-visual impairments)对主观幸福感(subjective well-being,SWB)的影响,以及抑郁倾向是否中介了视听障碍与主观幸福感之间的关联。方法中国健康与退休纵向调查(The China Health and Retirement Longitudinal Survey,CHARLS)对45岁及以上的中老年人进行问卷调查,在全国30个省级行政单位中采用多阶段抽样,分别在县(区)-村(居)-家户-个人层面上进行抽样,并在县(区)-村(居)两级抽样中,采用按人口规模成比例的概率(proportional probability sampling,PPS)抽样,最终纳入了28个省份150个县(区)的450个村/社区。本研究基于2018年的CHARLS数据展开研究,纳入标准为:(1)年龄≥60岁;(2)有完整的自我报告的视力和听力状况;(3)至少含有生活满意度、主观期望寿命、自评健康状况3项主观幸福感指标中的一个。CHARLS使用Likert五分量表测定老年人的主观幸福感,使用10项流调中心抑郁自评量表(the Center for Epidemiology Studies Depression Scale-10,CESD-10)测定老年人的抑郁倾向。本研究采用多元回归分析视听障碍与抑郁倾向、主观幸福感之间的关联,并通过中介模型分析抑郁倾向的中介作用。双侧P值<0.05被认为有统计学意义。结果最终纳入符合标准的研究对象7620人。其中有视听障碍的患者抑郁倾向水平明显更高,主观幸福感的三项指标均较低(P值均小于0.05)。视觉障碍、听觉障碍和视听双重障碍与更高的抑郁倾向水平和更低的自评健康、主观期望寿命有关;视觉障碍和视听双重障碍与较低的生活满意度有关。抑郁倾向在视听双重障碍与生活满意度间及视觉障碍、听觉障碍、视听双重障碍与自评健康和主观期望寿命间起部分中介作用。结论在中国老年人群中,视听障碍与较低的主观幸福感状态有关,抑郁倾向在其中起着中介作用。