期刊文献+
共找到208篇文章
< 1 2 11 >
每页显示 20 50 100
Meta-analysis of the efficacy of volar plate internal fixation versus closed reduction and external fixation in the treatment of adult distal radius fractures
1
作者 CHEN Jian-ge ZHANG Hai-ning +4 位作者 ZHAO Hong-zhou LIU Ming-jun XING Jia-hui WANG Ping WANG Wei-min 《Journal of Hainan Medical University》 CAS 2023年第19期44-56,共13页
Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The ... Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority. 展开更多
关键词 volar plate Internal fixation Closed reduction External fixation PLASTER SPLINT Distal radius fracture Meta analysis
下载PDF
Finite Element Analysis Study of Prototype of a Novel Intramedullary Injectable Bioresorbable Polymer Fixator versus a Volar Plate for Surgical Treatment of Distal Radius Fractures
2
作者 Adam Zysk Gladius Lewis 《World Journal of Engineering and Technology》 2017年第4期648-667,共20页
Complications and shortcomings of volar plating, which is very widely used for surgical treatment of distal radius fractures, are well known. Thus, there is scope for alternative innovative surgical methods. In the pr... Complications and shortcomings of volar plating, which is very widely used for surgical treatment of distal radius fractures, are well known. Thus, there is scope for alternative innovative surgical methods. In the present work, we used the finite element analysis method to compare the biomechanical performance of a model of a construct comprising a simulated distal radius fracture considered fixated using a notional intramedullary injectable bioresorbable polymer-bioresorbable balloon osteosynthesis system (“fixator”) versus using a commercially-available volar locking plate (VP). The biomechanical parameters determined were longitudinal stiffness and factor of safety under each of the applied loads.?For the fixator model, 1) each of the biomechanical parameters was markedly influenced by fracture gap fill ratio (FGFR) (defined as the proportion of the volume of the fracture gap that is considered occupied by the expanded polymer-filled balloon)?but not by modulus of elasticity assigned to the polymer;2) with FGFR = 100%, stiffness was comparable to that of the Ti-6Al-4V alloy VP construct model;and 3) stiffness was within the range of literature values for stiffness of constructs comprising simulated fractures in fresh cadaveric distal radii fixated using metal volar locking plate. These results suggest that the fixator may be an alternative modality to metal volar plating and, as such, deserves further evaluation. 展开更多
关键词 DISTAL Radius Fracture volar Locking plate INTRAMEDULLARY Fixation Finite Element Analysis
下载PDF
A comparative study of variable angle volar plate and bridging external fixator with K-wire augmentation in comminuted distal radius fractures 被引量:3
3
作者 Ratish Kumar Mishra Bhagwati Prasad Sharma +1 位作者 Amit Kumar Rohit Sherawat 《Chinese Journal of Traumatology》 CAS CSCD 2021年第5期301-305,共5页
Purpose:Comminuted intraarticular distal radial fractures are difficult to treat conservatively and require operative treatment.This study compared the functional outcomes between variable angle volar plating and exte... Purpose:Comminuted intraarticular distal radial fractures are difficult to treat conservatively and require operative treatment.This study compared the functional outcomes between variable angle volar plating and external fixator with K-wire augmentation in open reduction and internal fixation.Methods:A total of 62 adult patients with comminuted intraarticular distal radius fracture were randomized into 2 groups:volar plate group and external fixator group.These patients aged between 18 and 60 years had unilateral fractures,and agreed to be included in the study.Patients with a history of fracture,bilateral fracture,associated other injuries,delayed injury for more than 2 weeks,open fracture,pre-existing arthrosis or disability,psychiatric illness and pathological fracture were excluded.Patients were followed up at 6 weeks,3 months,6 months and 1 year.The assessment of pain,functional activity,range of motion and grip strength was done at each stage of follow-up.The pain and functional activities were assessed by patient rated wrist evaluation(PRWE)score and disabilities of the arm,shoulder and hand(DASH)score.Results:Patients in volar plate group had superior PRWE score and DASH score at each stage of followup.At 1 year follow-up,the mean PRWE score were 7.48 for volar plate group and 7.35 for external fixator group;while the mean DASH score was 4.65 for volar plate group and 5.61 for external fixator group.They had better flexion and extension range of movement.They also had better pronation and supination range of motion at initial follow-up,however the difference get attenuated by 1 year.Volar plate group had significantly better grip strength than external fixator group.Complication rates were higher in external fixation group.Conclusion:Fixation with variable angle volar plate results in early wrist mobilization,better range of movement,less pain and disability and early return of function. 展开更多
关键词 COMMINUTED Distal radius fracture INTRAARTICULAR volar plate External fixator
原文传递
Distal radius volar rim plate: Technical and radiographic considerations 被引量:3
4
作者 Michelle Spiteri Darren Roberts +2 位作者 Wayne Ng Jamie Matthews Dominic Power 《World Journal of Orthopedics》 2017年第7期567-573,共7页
AIM To determine technical considerations and radiographic outcomes of the Synthes volar rim distal radius plate to treat complex intra-articular fractures. METHODS This review highlights technical considerations lear... AIM To determine technical considerations and radiographic outcomes of the Synthes volar rim distal radius plate to treat complex intra-articular fractures. METHODS This review highlights technical considerations learnt using this implant since it was introduced in a major trauma unit in November 2011, including anatomical reduction and whether this was maintained radiographically. RESULTS Twenty-six of the 382 internally fixed distal radial fractures at our unit(6.8%) were deemed to require this plate in order to achieve optimal fracture fixation between November 2011 and May 2014. A further dorsal and/or radial plate was necessary in 35% and variable angle screws were used in 54% of cases. Postoperatively, mean radial height, inclination, volar tilt and ulnar variance restored were 11.7 mm, 21o, 4.3o and-1.2 mm respectively. There were no cases of non-union or flexor/extensor tendon rupture; one case of loss of fracture reduction. Overall incidence of plate removal was 15% with one plate removed for flexor and one for extensor tendon irritation CONCLUSION The use of a rim plate enables control of challenging fardistal fracture patterns. However, additional plates were required to improve and maintain reduction. Variable angle screws were necessary in half the cases to avoid intra-articular screw penetration. If used judiciously, this implant can achieve stable fixation despite the complexity of the fracture pattern. 展开更多
关键词 DISTAL RADIUS fractures volar RIM plate volar plating DISTAL RADIUS
下载PDF
Volar locking distal radius plates show better short-term results than other treatment options: A prospective randomised controlled trial 被引量:18
5
作者 Herwig Drobetz Lidia Koval +4 位作者 Patrick Weninger Ruth Luscombe Paula Jeffries Stefan Ehrendorfer Clare Heal 《World Journal of Orthopedics》 2016年第10期687-694,共8页
AIM To compare the outcomes of displaced distal radius fractures treated with volar locking plates and with immediate postoperative mobilisation with the outcomes of these fractures treated with modalities that necess... AIM To compare the outcomes of displaced distal radius fractures treated with volar locking plates and with immediate postoperative mobilisation with the outcomes of these fractures treated with modalities that necessitate 6 wk wrist immobilisation.METHODS A prospective, randomised controlled single-centre trial was conducted with 56 patients who had a displaced radius fracture were randomised to treatment either with a volar locking plate(n = 29), or another treatment modality(n = 27; cast immobilisation with or without wires or external fixator). Outcomes were measured at 12 wk. Functional outcome scores measured were the Patient-Rated Wrist Evaluation(PRWE) Score; Disabilities of the Arm, Shoulder and Hand and activities of daily living(ADLs). Clinical outcomes were wrist range of motion and grip strength. Radiographic parameters were volar inclination and ulnar variance.RESULTS Patients in the volar locking plate group had significantly better PRWE scores, ADL scores, grip strength and range of extension at three months compared with the control group. All radiological parameters were significantly better in the volar locking plate group at 3 mo. CONCLUSION The present study suggests that volar locking plates produced significantly better functional and clinical outcomes at 3 mo compared with other treatment modalities. Anatomical reduction was significantly more likely to be preserved in the plating group. Level of evidence: Ⅱ. 展开更多
关键词 volar LOCKING DISTAL RADIUS plate PROSPECTIVE randomised controlled Postoperative mobilisation DISTAL RADIUS fracture SHORT-TERM outcome
下载PDF
Biomechanical Comparison of Prototype of a Novel Intramedullary Injectable Bioresorbable Polymer-Bioresorbable Balloon Osteosynthesis and a Volar Locking Plate for Treatment of Distal Radius Fractures 被引量:1
6
作者 Adam Zysk Gladius Lewis +1 位作者 Daniel Taxier John Rose 《World Journal of Engineering and Technology》 2017年第2期309-323,共15页
Background: There is a large assortment of modalities for the surgical treatment/management of distal radius fractures (DRFs), where the most widely used is the fixed-angle volar plating (VLP) system, which, sometimes... Background: There is a large assortment of modalities for the surgical treatment/management of distal radius fractures (DRFs), where the most widely used is the fixed-angle volar plating (VLP) system, which, sometimes, is referred to as the “surgical modality of choice”. While outcomes with each modality are usually good to excellent, each has its share of shortcomings and complications. Thus, there is scope for improvements to existing modalities and/or introduction of new ones. Study Purpose: We introduce a novel modality, namely, the prototype of an intramedullary injectable bioresorbable polymer-bioresorbable balloon osteosynthesis (IPBO) system, and investigated its plausibility. Experimental Procedures: The biomechanical performance of a construct comprising a synthetic distal radius (fourth-generation Sawbones?) on which a simulated fracture was created (4-mm wide osteotomy positioned 25 mm from the most distal end of the radius) and fixated with a placement of the IPBO system (SIPBO Construct) was compared to that when the fixation was with an approved Ti-6Al-4V alloy VLP system (SVLP Construct), under a clinically-relevant compressive loading protocol. Performance involved determination of quantitative parameters of the construct (initial longitudinal stiffness (ICLS), final longitudinal stiffness (FCLS), and load-to-failure (Pf)) and observation and recording of features of the construct at the fracture point. We also determined the quantitative parameters for the intact synthetic distal radius (control). Results: For each of the quantitative parameters, the range of values for SIPBO Construct was within that for SVLP Construct, suggesting that the IPBO System is a plausible modality. Also, for SIPBO Construct, failure occurred within the polymer zone, whereas, for SVLP Construct, some failure features were fracture of the cortical wall and of the dorsal proximal fragments. Conclusion: The findings suggest that the IPBO system is plausible. As such, it merits further study;for example, determination of the influence of fracture gap fill ratio (defined as the proportion of the fracture gap that is filled by the expanding balloon as the polymer is injected into the balloon) on a large collection of quantitative biomechanical parameters. 展开更多
关键词 Distal Radius Fractures volar Locking plate INJECTABLE BIORESORBABLE POLYMER BIOMECHANICAL Tests
下载PDF
Screw placement is everything: Risk factors for loss of reduction with volar locking distal radius plates 被引量:1
7
作者 Herwig Drobetz Alyce Black +2 位作者 Jonathan Davies Petra Buttner Clare Heal 《World Journal of Orthopedics》 2018年第10期203-209,共7页
AIM To determine factors correlated with postoperative radial shortening in patients with distal radius fractures treated with volar locking distal radius plates.METHODS A total of 250 patients with a distal radius fr... AIM To determine factors correlated with postoperative radial shortening in patients with distal radius fractures treated with volar locking distal radius plates.METHODS A total of 250 patients with a distal radius fracture stabilised with volar locking plates between January 2010 and December 2014 were included in a multicentre retrospective cohort study. We measured the distance of the distal locking screws to the joint line immediately postoperatively and then measured radial shortening after six to eight weeks using the change in ulnar variance.RESULTS Multivariate linear regression analysis showed that there was a significant linear association between the distance of the screws from the joint line and radial shortening. No other patient, injury, or treatment-related characteristic significantly influenced radial shortening in multivariate analysis.CONCLUSION Distal locking screws should be placed as close as possible to the subchondral joint line to prevent postoperative loss of reduction. 展开更多
关键词 LOSS of REDUCTION volar LOCKING DISTAL RADIUS plate DISTAL RADIUS fracture Screw placement Cohort study
下载PDF
Dynamic External Fixator Combined with Volar Locking Plate Fixation for the Treatment of AO Type C3 Distal Radius Fractures
8
作者 Kinya Nishida Yong Ho Che +3 位作者 Hideto Irifune Kazuhiro Uesugi Akane Maeda Koji Miyata 《Open Journal of Orthopedics》 2022年第4期131-141,共11页
Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic... Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic outcomes of comminuted intra-articular DRFs treated with a dynamic external fixator combined with a volar locking plate (VLP). Methods: Eleven patients (mean age, 61 years) with comminuted intra-articular DRFs were treated with a dynamic type of external fixator combined with a VLP. Following reduction and fixation with a VLP, the dynamic external fixator was applied and the distal ball joint of the fixator was aligned with the lunate-capitate line. The ball joint was unlocked approximately 2 weeks after surgery to allow wrist mobilization. The fixator was removed 3 - 6 weeks (mean, 5 weeks) after surgery. Consequently, clinical and radiographic assessments were carried out at the final follow-up. Results: At the final follow-up, the mean range values of wrist extension and flexion were 76&deg;and 64&deg;, respectively. Compared with the contralateral side, the mean grip strength was 84%. The mean Modified Mayo Wrist Score and the Disabilities of the Arm, Shoulder and Hand score were 88 and 9, respectively. No significant differences in the radiographic parameters exist between after surgery and final follow-up. Conclusions: This study indicated that the dynamic wrist fixator combined with a VLP is effective for the treatment of AO type C3 DRFs. 展开更多
关键词 Distal Radius Fracture Intra-Articular Fracture External Fixator Dynamic External Fixator volar Locking plate
下载PDF
累及背侧关节面桡骨远端骨折的骨折线地图特征:螺钉有效固定治疗术后移位
9
作者 胡流超 罗毅文 吴志方 《中国组织工程研究》 CAS 北大核心 2025年第3期524-530,共7页
背景:掌侧锁定钢板固定是桡骨远端骨折临床上最常用的固定方式,但当骨折线累及背侧关节面时,掌侧钢板固定则存在术后背侧骨块移位风险,尤其是乙状切迹背侧骨块术后移位风险较高。目的:分析桡骨远端骨折累及背侧关节面的骨折线特点,进而... 背景:掌侧锁定钢板固定是桡骨远端骨折临床上最常用的固定方式,但当骨折线累及背侧关节面时,掌侧钢板固定则存在术后背侧骨块移位风险,尤其是乙状切迹背侧骨块术后移位风险较高。目的:分析桡骨远端骨折累及背侧关节面的骨折线特点,进而深入研究累及乙状切迹背侧骨块发生术后移位的危险因素,为临床上提高复位成功率提供依据。方法:对2021年1月至2022年9月在广州中医药大学第三附属医院就诊的桡骨远端骨折患者进行回顾性分析。根据术前CT影像桡骨远端背侧骨折块数量1,2,3块及以上分别记为Ⅰ,Ⅱ,Ⅲ型骨折,分别绘制骨折线地图,分析其背侧骨折线形态特征。对存在乙状切迹背侧骨折的患者进行3个月以上随访,根据术后是否发生乙状切迹背侧骨块移位分为移位组和无移位组,比较两组患者年龄、性别、术前和术后CT解剖参数。结果与结论:①对AO/OTA分型C型累及背侧关节面145例患者进行骨折线地图分析,其中根据背侧骨折块数量:Ⅰ型25例(17.2%)、Ⅱ型82例(56.6%)、Ⅲ型38例(26.2%);骨折线地图显示Ⅰ型骨折块骨折线主要累及乙状切迹,Ⅱ型主要累及乙状切迹和lister结节,Ⅲ型则累及乙状切迹、lister结节和桡侧柱背侧。145例患者中86.2%(125/145例)累及乙状切迹,其中Ⅲ型累及比例高达94.7%(36/38例),Ⅱ型88.0%(72/82例),Ⅰ型68%(17/25例)。②76例AO/OTA分型C型累及乙状切迹背侧患者纳入进一步研究,其中术后未移位组65例,移位组11例;在单因素分析中,两组患者的年龄、性别、受伤部位、术前CT乙状切迹背侧骨块背侧边长(d1)、尺侧边长(d2)、乙状切迹背侧骨块背侧高度(d4)和钢板距桡骨尺侧边缘距离(d5)比较差异均无显著性意义(P>0.05);乙状切迹背侧骨块累及下尺桡关节占比[d2/(d2+d3)]、乙状切迹背侧骨块关节面占比(s1/s2)、尺侧螺钉尾端距背侧乙状切迹边缘的距离(d6)和乙状切迹背侧骨块螺钉固定的数量比较差异有显著性意义(P<0.05)。③Logistic多因素回归分析显示,乙状切迹骨块螺钉固定的数量是影响尺背侧乙状切迹骨块移位唯一的危险因素(P<0.05)。④提示在累及桡骨背侧的桡骨远端关节内骨折中,Ⅱ型最常见,Ⅲ型和Ⅰ型次之,大部分患者均存在乙状切迹背侧骨块。而乙状切迹背侧骨块其受下尺桡关节韧带影响易发生术后移位,术中至少1枚有效螺钉固定能降低其移位风险并有助于提高治疗效果。 展开更多
关键词 桡骨远端骨折 乙状切迹背侧骨块 掌侧钢板 内固定 骨折线
下载PDF
经旋前方肌下肌骨通道保留旋前方肌内固定治疗桡骨远端骨折
10
作者 郭永杰 徐建 +1 位作者 刘赟 盛飞 《临床骨科杂志》 2024年第2期238-242,共5页
目的探讨经旋前方肌下肌骨通道保留旋前方肌内固定治疗桡骨远端骨折的疗效。方法将100例桡骨远端骨折患者根据是否保留旋前方肌分为对照组(采用倒L形切口切开旋前方肌内固定治疗,54例)和观察组(采用经旋前方肌下肌骨通道保留旋前方肌内... 目的探讨经旋前方肌下肌骨通道保留旋前方肌内固定治疗桡骨远端骨折的疗效。方法将100例桡骨远端骨折患者根据是否保留旋前方肌分为对照组(采用倒L形切口切开旋前方肌内固定治疗,54例)和观察组(采用经旋前方肌下肌骨通道保留旋前方肌内固定治疗,46例)。记录骨折复位及愈合情况、疼痛VAS评分、腕关节影像学指标、前臂及腕关节活动度、Gartland-Werley评分。结果患者均获得随访,时间12~20个月。术后X线片显示:骨折均对位对线良好,关节面恢复平整,达到解剖复位。两组骨折均愈合良好,时间2.7~5.5个月。术后6周疼痛VAS评分、前臂旋前及旋后活动度、Gartland-Werley评分观察组均优于对照组(P<0.05);末次随访时前臂旋前活动度观察组大于对照组(P<0.05),前臂旋后活动度、Gartland-Werley评分两组比较差异均无统计学意义(P>0.05)。末次随访时腕关节掌屈、背伸活动度及掌倾角、尺偏角两组比较差异均无统计学意义(P>0.05)。结论经旋前方肌下肌骨通道保留旋前方肌内固定治疗桡骨远端骨折,可缩短患者康复时间,最大程度保留前臂旋前功能,且安全有效。 展开更多
关键词 桡骨远端骨折 掌侧锁定钢板 保留旋前方肌
下载PDF
改良Henry入路保留旋前方肌掌侧锁定钢板内固定治疗桡骨远端骨折疗效分析
11
作者 黎成成 殷子敬 +1 位作者 张云航 区钰强 《中国烧伤创疡杂志》 2024年第3期214-217,236,共5页
目的探讨改良Henry入路保留旋前方肌掌侧锁定钢板内固定治疗桡骨远端骨折的临床疗效。方法选取2018年1月至2022年1月肇庆市中医院收治的84例桡骨远端骨折患者作为研究对象,按照不同手术方法将其分为观察组(42例)和对照组(42例),观察组... 目的探讨改良Henry入路保留旋前方肌掌侧锁定钢板内固定治疗桡骨远端骨折的临床疗效。方法选取2018年1月至2022年1月肇庆市中医院收治的84例桡骨远端骨折患者作为研究对象,按照不同手术方法将其分为观察组(42例)和对照组(42例),观察组患者采用改良Henry入路保留旋前方肌掌侧锁定钢板内固定治疗,对照组患者采用改良Henry入路离断旋前方肌掌侧锁定钢板内固定治疗,对比观察两组患者上肢功能障碍评定量表(Quick-DASH)评分、腕关节功能患者自行评估量表(PRWE)评分、Mayo腕关节功能评分(简称Mayo评分)、视觉模拟评分法(VAS)评分及不良事件发生情况。结果术后1、6个月,观察组患者Quick-DASH、PRWE及VAS评分均明显低于对照组,Mayo评分明显高于对照组(术后1个月:t=3293、4123、2902、2366,P=0002、P<0001、P=0005、P=0020;术后6个月:t=4877、4136、2139、2695,P<0001、P<0001、P=0035、P=0009);观察组患者术后不良事件发生率为714%,明显低于对照组患者的术后不良事件发生率2381%(χ^(2)=4459,P=0035)。结论桡骨远端骨折采用改良Henry入路保留旋前方肌掌侧锁定钢板内固定治疗更能明显减轻患者疼痛,促进上肢功能及腕关节功能恢复,降低术后不良事件发生风险。 展开更多
关键词 桡骨远端骨折 Henry入路 掌侧锁定钢板 保留旋前方肌 疼痛 上肢功能 腕关节功能
下载PDF
掌侧万向锁定接骨钢板与外固定夹板治疗桡骨远端骨折的对比研究
12
作者 肖芳繁 胡婷 林星良 《四川生理科学杂志》 2024年第2期305-307,共3页
目的:探讨掌侧万向锁定接骨钢板与外固定夹板治疗桡骨远端骨折对骨折部位关节功能的影响及安全性。方法:选取2020年1月-2023年1月本院收治的80例桡骨远端骨折的患者,根据手术方法的不同,将其分为观察组和对照组,观察组(n=42)使用掌侧万... 目的:探讨掌侧万向锁定接骨钢板与外固定夹板治疗桡骨远端骨折对骨折部位关节功能的影响及安全性。方法:选取2020年1月-2023年1月本院收治的80例桡骨远端骨折的患者,根据手术方法的不同,将其分为观察组和对照组,观察组(n=42)使用掌侧万向锁定接骨钢板治疗,对照组(n=38)使用外固定夹板治疗,观察并比较两组骨折线消失、骨痂出现时间,术前、术后4 w、术后8 w腕关节尺偏角、掌倾角,腕关节活动度(屈伸度、旋转度、内收外展活动度)以及并发症发生情况。结果:观察组骨痂出现时间、骨折线消失时间均早于对照组(P<0.05);两组术后3 m腕关节尺偏角、掌倾角均优于术前(P<0.05);两组术后3 m腕关节尺屈伸度、旋转度、内收外展活动度均优于术前,且观察组术后3 m腕关节屈伸度、旋转度、内收外展活动度优于对照组(P<0.05)。结论:与外固定夹板相比,桡骨远端骨折患者选择掌侧万向锁定接骨钢板治疗,在改善患者腕关节,缩短骨折线消失、骨痂出现时间方面优势更佳。 展开更多
关键词 桡骨远端骨折 掌侧万向锁定接骨钢板 外固定夹板
下载PDF
掌侧钢板内固定与闭合复位外固定治疗成人桡骨远端骨折疗效的Meta分析 被引量:2
13
作者 陈牮阁 张海宁 +4 位作者 赵洪洲 刘鸣峻 邢加辉 王平 王为民 《海南医学院学报》 2023年第19期1491-1504,共14页
目的:应用Meta分析的方法比较切开复位掌侧锁定钢板内固定与闭合复位外固定治疗桡骨远端骨折的疗效差异。方法:检索中国知网、万方、维普、中国生物医学文献、Pubmed、Embase、Cochrane Library数据库,收集自建库以来至2023年4月公开发... 目的:应用Meta分析的方法比较切开复位掌侧锁定钢板内固定与闭合复位外固定治疗桡骨远端骨折的疗效差异。方法:检索中国知网、万方、维普、中国生物医学文献、Pubmed、Embase、Cochrane Library数据库,收集自建库以来至2023年4月公开发表的直接比较钢板内固定与闭合复位外固定治疗桡骨远端骨折疗效差异的随机对照研究。2名研究者根据纳入及排除标准对检索文献进行独立筛选,提取数据并采用Cochrane风险偏倚评估工具进行质量评估,并使用RevMan 5.4软件进行Meta分析。结果:共纳入10篇随机对照试验研究,均为英文文献,共计1042例患者,其中9篇文献质量评为低风险。Meta分析结果显示,掌侧锁定钢板内固定治疗桡骨远端骨折在1年后DASH评分[MD=−5.64,95%CI(−7.21,−4.06),P<0.00001];1年后PRWE评分[MD=−5.90,95%CI(−8.88,−2.92),P=0.001];掌屈[MD=5.92,95%CI(1.29,10.55),P=0.01];旋前[MD=2.48,95%CI(0.59,4.36),P=0.01];旋后[MD=4.73,95%CI(2.15,7.31),P=0.0003];握力[MD=0.61,95%CI(0.12,1.10),P=0.02];掌倾角[MD=9.84,95%CI(5.66,14.02),P<0.00001];尺偏角[MD=4.33,95%CI(2.97,5.69),P<0.00001]方面均优于闭合复位石膏或夹板外固定治疗。二者在1年后欧洲五维健康量表(EQ‑5D‑5L)评分[MD=0.02,95%CI(−0.01,0.05),P=0.27];背伸[MD=2.22,95%CI(−4.15,8.59),P=0.49];尺偏[MD=3.49,95%CI(−0.80,7.78),P=0.11];桡偏[MD=2.05,95%CI(−2.39,6.50),P=0.37];尺骨变异[MD=−1.14,95%CI(−3.16,0.88),P=0.27];并发症[MD=0.77,95%CI(0.54,1.10),P=0.16]方面差异均无统计学意义(P>0.05)。结论:基于当前临床数据,掌侧锁定钢板内固定较闭合复位石膏或夹板外固定治疗更有利于中期DASH评分和握力恢复,但患者的生活质量及并发症等无明显差异。对于成人桡骨远端骨折,应谨慎把握手术适应症,优先考虑非手术治疗。 展开更多
关键词 钢板 内固定 闭合复位 外固定 石膏 夹板 桡骨远端骨折 META分析
下载PDF
保留旋前方肌完整性联合掌侧锁定钢板内固定治疗桡骨远端骨折 被引量:12
14
作者 黄晓夏 贾麒钰 +4 位作者 伊尔夏提·克力木 彭聪 孔维奇 滕勇 赵岩 《中国组织工程研究》 CAS 北大核心 2023年第31期4959-4964,共6页
背景:桡骨远端骨折最常用入路是传统Henry入路,但术中需切断旋前方肌,修复旋前方肌失败会带来一系列并发症。目的:探讨保留旋前方肌联合掌侧锁定钢板治疗桡骨远端骨折的临床效果。方法:回顾性分组对照分析64例桡骨远端骨折患者的临床资... 背景:桡骨远端骨折最常用入路是传统Henry入路,但术中需切断旋前方肌,修复旋前方肌失败会带来一系列并发症。目的:探讨保留旋前方肌联合掌侧锁定钢板治疗桡骨远端骨折的临床效果。方法:回顾性分组对照分析64例桡骨远端骨折患者的临床资料,其中采取保留旋前方肌完整性方法的为改良组32例,按AO分型,23-B1型8例,23-B2型7例,23-B3例7例,23-C1型6例,23-C2型4例;采取传统Henry入路切断旋前方肌方法的为传统组32例,其中23-B1型7例,23-B2型9例,23-B3型3例,23-C1型6例,23-C2型7例。观察两组患者术后内固定、骨折愈合、术后并发症等情况,比较两组术后腕部疼痛目测类比评分(VAS),分别采用Dienst关节评分标准评估患者腕关节功能、影像学指标评估手术疗效。结果与结论:①改良组患者的平均手术时间及术中平均失血量均显著少于传统组(Z=-6.77,P<0.01;Z=-5.41,P<0.01);②改良组患者骨折平均愈合时间短于传统组(Z=-2.08,P<0.05);③术后12个月改良组和传统组患者腕关节功能优良率分别为94%(30/32)、88%(28/32),差异无显著性意义(χ2=0.767,P=0.682);④术后3 d及1,3个月两组患者腕关节正侧位X射线片显示,桡骨高度、掌倾角、尺偏角相比差异均无显著性意义(P>0.05);⑤术后1周及1,3个月改良组患者目测类比评分均低于传统组(P<0.05),而术后12个月两组患者目测类比评分相比差异无显著性意义(P>0.05);⑥两组患者术后均未出现创伤性关节炎;传统组有2例腕管综合(Ⅱ期取出内固定装置症状缓解);⑦结果说明,保留旋前方肌的改良Henry方法在后期旋前角度和疼痛上没有显著优势;然而,术中可以缩短手术时间,减少术中出血,减少术后早期疼痛,促进早期活动。 展开更多
关键词 桡骨远端 骨折 保留 掌侧钢板 旋前方肌 Henry入路
下载PDF
腕关节四位片术中透视联合桡骨远端掌侧“T”型万向锁定钛板内固定应用于桡骨远端骨折的疗效研究 被引量:1
15
作者 张仲传 朱勋兵 +3 位作者 袁伶俐 韩俊柱 徐文弟 未洋洋 《蚌埠医学院学报》 CAS 2023年第8期1045-1049,1055,共6页
目的:观察腕关节四位片术中透视联合桡骨远端掌侧“T”型万向锁定钛板内固定应用于桡骨远端骨折的疗效。方法:回顾性分析行切开复位锁定钢板内固定治疗的42例桡骨远端骨折病例,手术均采用Henry入路,术中均行腕关节四位片透视(标准正侧... 目的:观察腕关节四位片术中透视联合桡骨远端掌侧“T”型万向锁定钛板内固定应用于桡骨远端骨折的疗效。方法:回顾性分析行切开复位锁定钢板内固定治疗的42例桡骨远端骨折病例,手术均采用Henry入路,术中均行腕关节四位片透视(标准正侧位、侧位切线位和腕掌屈切线位),明确螺钉有无进入关节腔、下尺桡关节及穿出桡骨远端背侧皮质,所有病人术后常规行腕关节CT三维重建检查,进行影像学评估。比较桡骨远端骨折术前术后骨折复位质量情况,比较术前及末次随访时Cooney腕关节功能评分,比较术中腕关节正侧位及四位片问题螺钉检出率。结果:所有病人手术时间45~90 min,手术出血量20~100 mL,手术切口均临床一期愈合,无切口感染、钢板外露等并发症。末次随访时Cooney腕关节功能评分优良率明显高于术前(P<0.01)。治疗后病人的桡骨高度、掌倾角及尺偏角均明显大于治疗前(P<0.01)。正侧位透视与四位片透视问题螺钉检出率比较差异有统计学意义(P<0.01)。术中所有问题螺钉均予以及时调整,术后复查腕关节三维CT发现42例病例中1例病人桡侧柱一枚螺钉突破背侧皮质约2 mm,后期随访未出现背侧肌腱激惹症状。结论:桡骨远端掌侧“T”型万向锁定钛板应用于桡骨远端骨折,可以取得满意的骨折复位和较好的临床疗效,病人可以实现快速康复锻炼。 展开更多
关键词 桡骨远端骨折 掌侧“T”型钢板 腕关节四位片
下载PDF
特殊透视方法在掌侧锁定钢板治疗桡骨远端骨折中的临床应用 被引量:1
16
作者 章荣 牛和明 +4 位作者 郭涛 解平锋 吴加明 谢加兵 王林 《中国骨伤》 CAS CSCD 2023年第2期128-132,共5页
目的:通过术中附加透视拍摄侧斜位X线片观察桡骨远端螺钉与腕关节面关系及腕背切线位X线片观察远端螺钉是否穿出背侧皮质,从而评价掌侧锁定钢板治疗桡骨远端骨折的临床疗效。方法:自2020年1月至2021年6月,手术采用掌侧Henry入路治疗新... 目的:通过术中附加透视拍摄侧斜位X线片观察桡骨远端螺钉与腕关节面关系及腕背切线位X线片观察远端螺钉是否穿出背侧皮质,从而评价掌侧锁定钢板治疗桡骨远端骨折的临床疗效。方法:自2020年1月至2021年6月,手术采用掌侧Henry入路治疗新鲜桡骨远端骨折45例,其中男20例,女25例,年龄32~75(52.4±8.1)岁。术中根据不同透视方法分为两组:对照组20例,为单纯透视拍摄标准正侧位X线片;观察组25例,在透视拍摄标准正侧位X线片基础上附加透视拍摄侧斜位X线片及腕背切线位X线片。观察两组术后6周及3、6个月腕关节功能评分和术后并发症发生情况。结果:45例患者均获得随访,时间为6~14(10.8±1.7)个月,患者切口愈合良好,均获得骨性愈合。观察组并发症发生率低于对照组(P<0.05)。腕关节功能Gartland-Werley评分,观察组术后6周(4.58±1.31)分、3个月(2.98±0.63)分、6个月(1.95±0.65)分,均优于对照组术后6周(6.32±1.96)分、3个月(3.63±0.76)分、6个月(2.43±0.73)分,差异具有统计学意义(P<0.05)。观察组25例患者,术中通过加摄侧斜位X线片及腕背切线位X线片透视发现问题7例,阳性率为28%。结论:术中附加透视拍摄侧斜位X线片及腕背切线位X线片,可以提高远端螺钉置入的准确性,减少术后并发症的发生,实现早期功能锻炼,有利于腕关节功能恢复。 展开更多
关键词 桡骨远端骨折 掌侧入路 锁定钢板 透视方法
下载PDF
背侧克氏针增强AO C型桡骨远端骨折尺背侧骨折块稳定性的有限元分析 被引量:8
17
作者 殷浩 陈光 +2 位作者 李燕 周恩昌 宁仁德 《中国组织工程研究》 CAS 北大核心 2023年第31期4921-4925,共5页
背景:波及尺背侧骨折块的桡骨远端骨折属于不稳定型骨折,属于AO分型的23C型、三柱分型中波及中间柱的骨折,尺背侧骨折块不能得到有效固定,将影响桡腕关节和下尺桡关节的稳定性,而当前单纯掌侧钢板固定尺背侧骨折块的作用有限,若附加背... 背景:波及尺背侧骨折块的桡骨远端骨折属于不稳定型骨折,属于AO分型的23C型、三柱分型中波及中间柱的骨折,尺背侧骨折块不能得到有效固定,将影响桡腕关节和下尺桡关节的稳定性,而当前单纯掌侧钢板固定尺背侧骨折块的作用有限,若附加背侧钢板虽然固定效果好,但将增加手术创伤、导致肌腱损伤粘连,并提高了治疗费用,不符合当前疾病诊断相关分组的政策,附加背侧克氏针固定是个较为可行的方案。目的:通过建立AO/ASIF 23-C1桡骨远端骨折的有限元模型,比较掌侧锁定钢板和掌侧锁定钢板附加背侧克氏针两种内固定方式生物力学稳定性的差异,尤其关注尺背侧骨折块的固定效果,为临床应用提供参考。方法:利用逆向建模技术,将42岁男性志愿者健康前臂CT数据及内固定数据导入相关软件,分别建立AO/ASIF 23-C1桡骨远端骨折掌侧锁定钢板和掌侧锁定钢板附加背侧克氏针内固定三维有限元模型。对模型分别施以100 N轴向载荷、1 Nm的弯曲及扭转载荷,比较两组尺背侧骨折块最大位移、内固定上最大Von Mises应力及应力分布等指标。结果与结论:①两种固定方式下,内固定上的应力均2-10倍于骨骼,符合骨折早期稳定的要求;②在3种不同载荷下,两组间应力峰值比较,无论是骨骼上还是内固定上的应力均差别不大(<30%);在轴向载荷下内固定上的应力峰值为骨骼的三四倍;但在弯曲载荷下,内固定上的应力峰值为骨骼的8-10倍;而在扭转载荷下内固定上的应力峰值仅为骨骼的2倍;③在轴向载荷下,两组间尺背侧骨折块的最大位移极小且差别不大,仅为0.056 mm和0.047 mm,表明骨折块的稳定性好;在弯曲载荷下,单一钢板固定组最大位移为克氏针固定组的2.4倍;在扭转载荷下,单一钢板固定组最大位移为克氏针固定组的2.7倍;④提示附加克氏针的掌骨锁定钢板能更好地固定尺背侧骨折块,应力分布更均匀,提高了固定强度,且未明显增加手术费用,更适合于当前疾病诊断相关分组控费下涉及尺背侧骨折块的桡骨远端骨折的治疗。 展开更多
关键词 桡骨远端骨折 内固定 掌侧锁定钢板 克氏针 位移 应力 生物力学 有限元分析
下载PDF
部分保留旋前方肌应用于桡骨远端骨折掌侧钢板螺钉内固定术的效果 被引量:1
18
作者 蓝思彬 谭睿 《中外医学研究》 2023年第25期125-129,共5页
目的:探讨部分保留旋前方肌应用于桡骨远端骨折掌侧钢板螺钉内固定术的效果。方法:选择2018年7月—2022年7月广州中医药大学第三附属医院收治的81例桡骨远端骨折掌侧钢板螺钉内固定术患者作为研究对象,根据随机数表法将其分为传统组(n=... 目的:探讨部分保留旋前方肌应用于桡骨远端骨折掌侧钢板螺钉内固定术的效果。方法:选择2018年7月—2022年7月广州中医药大学第三附属医院收治的81例桡骨远端骨折掌侧钢板螺钉内固定术患者作为研究对象,根据随机数表法将其分为传统组(n=40)和试验组(n=41)。传统组切开旋前方肌,试验组部分保留旋前方肌,比较两组临床指标、疼痛、腕关节活动度及切口愈合情况。结果:两组手术时间、住院时间、切口长度、术中出血量比较,差异无统计学意义(P>0.05);但试验组骨折愈合时间早于传统组,差异有统计学意义(P<0.05)。术后3 d,试验组视觉模拟评分法(VAS)评分低于传统组,差异有统计学意义(P<0.05);术后3个月,两组VAS评分均低于术后3 d,差异有统计学意义(P<0.05),但两组组间比较,差异无统计学意义(P>0.05)。术后3 d,试验组腕关节活动度优于传统组,差异有统计学意义(P<0.05);术后3个月,两组腕关节活动度均优于术后3 d,差异有统计学意义(P<0.05),但两组组间比较,差异无统计学意义(P>0.05)。试验组术后切口愈合不良率为4.88%(2/41),低于传统组的22.50%(9/40),差异有统计学意义(P<0.05)。结论:部分保留旋前方肌能缩短桡骨远端骨折掌侧钢板螺钉内固定术骨折愈合时间,减轻早期疼痛,有利于腕关节功能恢复,减少术后切口愈合不良。 展开更多
关键词 部分保留旋前方肌 桡骨远端骨折掌侧钢板螺钉内固定术 疼痛 腕关节活动度
下载PDF
VLP固定对桡骨远端C2/C3型骨折腕关节活动度、握力、尺骨变异的改善作用 被引量:2
19
作者 吴凤林 汤林海 《实用手外科杂志》 2023年第4期537-540,共4页
目的 探究掌侧锁定接骨板(Volar locking plate,VLP)固定对桡骨远端C2/C3型骨折腕关节活动度、握力、尺骨变异的改善作用。方法 选取2019年6月-2022年11月收治的82例桡骨远端C2/C3型骨折患者资料,根据治疗方式分为观察组(47例)和对照组... 目的 探究掌侧锁定接骨板(Volar locking plate,VLP)固定对桡骨远端C2/C3型骨折腕关节活动度、握力、尺骨变异的改善作用。方法 选取2019年6月-2022年11月收治的82例桡骨远端C2/C3型骨折患者资料,根据治疗方式分为观察组(47例)和对照组(35例),观察组使用VLP固定治疗,对照组使用外固定架治疗。比较两组手术时间、术中失血量、骨折愈合时间、腕关节活动度(掌屈度、背伸度、旋前度、旋后度)、握力、桡骨远端形态(掌倾角、尺倾角、尺骨变异)、术后并发症。结果 观察组手术时间长于对照组,术中失血量多于对照组,骨折愈合时间短于对照组,差异有统计学意义(P <0.05);术后6个月,观察组患侧腕关节掌屈度、背伸度、旋前度、旋后度、握力均大于对照组,差异有统计学意义(P <0.05);术后6个月,观察组患侧掌倾角、尺倾角均大于对照组,尺骨变异小于对照组,差异有统计学意义(P <0.05);两组术后并发症发生率比较差异无统计学意义(P>0.05)。结论 VLP固定有助于改善桡骨远端C2/C3型骨折腕关节活动度、握力,减少尺骨变异,具有较高安全性。 展开更多
关键词 掌侧锁定接骨板固定 桡骨远端C2/C3型骨折 腕关节活动度 握力 尺骨变异
下载PDF
桡骨远端骨折掌侧钢板内固定后关节僵硬的相关影响因素分析
20
作者 桂宇芳 胡波 陆文杰 《中国医学创新》 CAS 2023年第22期160-163,共4页
目的:分析桡骨远端骨折(DRF)掌侧钢板内固定后关节僵硬发生的影响因素,以便临床采取相关干预措施。方法:回顾性分析2019年8月—2021年8月于江西省中西医结合医院行掌侧钢板内固定治疗的100例DRF患者的临床资料,统计其术后关节僵硬发生情... 目的:分析桡骨远端骨折(DRF)掌侧钢板内固定后关节僵硬发生的影响因素,以便临床采取相关干预措施。方法:回顾性分析2019年8月—2021年8月于江西省中西医结合医院行掌侧钢板内固定治疗的100例DRF患者的临床资料,统计其术后关节僵硬发生情况,另收集所有患者的年龄、性别等一般资料,以多因素logistic回归分析模型分析DRF患者行掌侧钢板内固定治疗后关节僵硬发生的影响因素。结果:100例行掌侧钢板内固定治疗的DRF患者,术后发生关节僵硬26例,发生率为26.00%(26/100)。单因素分析显示:发生组和未发生组性别、体重指数(BMI)、骨折部位、受伤到手术时间比较,差异均无统计学意义(P>0.05);发生组年龄≥60岁、外固定时间>4周、功能锻炼不规律、术前肿胀程度为中重度占比均高于未发生组,差异均有统计学意义(P<0.05)。多因素logistic回归分析显示:年龄≥60岁、外固定时间>4周、功能锻炼不规律、术前中重度肿胀为DRF患者行掌侧钢板内固定治疗后发生关节僵硬的影响因素(P<0.05)。结论:DRF患者行掌侧钢板内固定治疗后关节僵硬发生率较高,而年龄≥60岁、外固定时间>4周、功能锻炼不规律、术前中重度肿胀为术后关节僵硬发生的影响因素,针对此临床需对上述因素予以高度重视,并施以针对性的干预措施,以加快患者恢复,减少术后关节僵硬的发生。 展开更多
关键词 桡骨远端骨折 掌侧钢板内固定 关节僵硬 影响因素
下载PDF
上一页 1 2 11 下一页 到第
使用帮助 返回顶部