Patients with complete spinal cord injury retain the potential for volitional muscle activity in muscles located below the spinal injury level.However,because of prolonged inactivity,initial attempts to activate these...Patients with complete spinal cord injury retain the potential for volitional muscle activity in muscles located below the spinal injury level.However,because of prolonged inactivity,initial attempts to activate these muscles may not effectively engage any of the remaining neurons in the descending pathway.A previous study unexpectedly found that a brief clinical round of passive activity significantly increased volitional muscle activation,as measured by surface electromyography.In this study,we further explored the effect of passive activity on surface electromyographic signals during volitional control tasks among individuals with complete spinal cord injury.Eleven patients with chronic complete thoracic spinal cord injury were recruited.Surface electromyography data from eight major leg muscles were acquired and compared before and after the passive activity protocol.The results indicated that the passive activity led to an increased number of activated volitional muscles and an increased frequency of activation.Although the cumulative root mean square of surface electromyography amplitude for volitional control of movement showed a slight increase after passive activity,the difference was not statistically significant.These findings suggest that brief passive activity may enhance the ability to initiate volitional muscle activity during surface electromyography tasks and underscore the potential of passive activity for improving residual motor control among patients with motor complete spinal cord injury.展开更多
The intelligent knee prosthesis is capable of human-like bionic lower limb control through advanced control systems and artificial intelligence algorithms that will potentially minimize gait limitations for above-knee...The intelligent knee prosthesis is capable of human-like bionic lower limb control through advanced control systems and artificial intelligence algorithms that will potentially minimize gait limitations for above-knee amputees and facilitate their reintegration into society.In this paper,we sum up the control strategies corresponding to the prevailing control objectives(position and impedance)of the current intelligent knee prosthesis.Although these control strategies have been successfully implemented and validated in relevant experiments,the existing deficiencies still fail to achieve optimal performance of the controllers,which complicates the definition of a standard control method.Before a mature control system can be developed,it is more important to realize the full potential for the control strategy,which requires upgrading and refining the relevant key technologies based on the existing control methods.For this reason,we discuss potential areas for improvement of the prosthetic control system based on the summarized control strategies,including intent recognition,sensor system,prosthetic evaluation,and parameter optimization algorithms,providing future directions toward optimizing control strategies for the next generation of intelligent knee prostheses.展开更多
基金supported by the Fundamental Research Funds for Central Public Welfare Research Institute,No.2020CZ-5(to WS and GS)the National Natural Science Foundation of China,No.31970970(to JSR)Fundamental Research Funds for the Central Universities,No.YWF-23-YG-QB-010(to JSR)。
文摘Patients with complete spinal cord injury retain the potential for volitional muscle activity in muscles located below the spinal injury level.However,because of prolonged inactivity,initial attempts to activate these muscles may not effectively engage any of the remaining neurons in the descending pathway.A previous study unexpectedly found that a brief clinical round of passive activity significantly increased volitional muscle activation,as measured by surface electromyography.In this study,we further explored the effect of passive activity on surface electromyographic signals during volitional control tasks among individuals with complete spinal cord injury.Eleven patients with chronic complete thoracic spinal cord injury were recruited.Surface electromyography data from eight major leg muscles were acquired and compared before and after the passive activity protocol.The results indicated that the passive activity led to an increased number of activated volitional muscles and an increased frequency of activation.Although the cumulative root mean square of surface electromyography amplitude for volitional control of movement showed a slight increase after passive activity,the difference was not statistically significant.These findings suggest that brief passive activity may enhance the ability to initiate volitional muscle activity during surface electromyography tasks and underscore the potential of passive activity for improving residual motor control among patients with motor complete spinal cord injury.
基金The authors would liketo thank the support of the National Natural Science Foundation of China(grant no.62073224)National Key Research and Development Program of China(grant no.2018YFB1307303).
文摘The intelligent knee prosthesis is capable of human-like bionic lower limb control through advanced control systems and artificial intelligence algorithms that will potentially minimize gait limitations for above-knee amputees and facilitate their reintegration into society.In this paper,we sum up the control strategies corresponding to the prevailing control objectives(position and impedance)of the current intelligent knee prosthesis.Although these control strategies have been successfully implemented and validated in relevant experiments,the existing deficiencies still fail to achieve optimal performance of the controllers,which complicates the definition of a standard control method.Before a mature control system can be developed,it is more important to realize the full potential for the control strategy,which requires upgrading and refining the relevant key technologies based on the existing control methods.For this reason,we discuss potential areas for improvement of the prosthetic control system based on the summarized control strategies,including intent recognition,sensor system,prosthetic evaluation,and parameter optimization algorithms,providing future directions toward optimizing control strategies for the next generation of intelligent knee prostheses.