This paper proposes a novel AC filter system for a line commutated converter high voltage DC(LCC-HVDC)transmission system.Through the coordination of the hybrid active power filters(APF)and the existing reactive compe...This paper proposes a novel AC filter system for a line commutated converter high voltage DC(LCC-HVDC)transmission system.Through the coordination of the hybrid active power filters(APF)and the existing reactive compensation devices,the proposed filter system can not only enhance the suppression performance for LCC-HVDC harmonics,but also optimize the AC yard layout with reduced reactive power subbanks,reducing the cost of HVDC projects.The novel filter system adopts a serial passive resonance topology obtained by careful comparison of different APFs.A proper control scheme is then designed integrating the control strategy of the APF and impedance characteristics of the HVDC system,which is able to realize harmonic suppression and dynamic reactive power support simultaneously.In addition,a novel self-adaption digital low-pass filter algorithm is presented,which is used in the APF harmonic detecting step,enhancing both high precision and fast dynamic response.On the basis of a real HVDC project,the advantages of proposed filter system in harmonic suppression,reactive power regulation,and sub-banks reduction are simulated and demonstrated.展开更多
In line commutated converter based high-voltage direct current(LCC-HVDC)transmission systems,the transformer saturation can induce harmonic instability,which poses a serious threat to the safe operation of the power s...In line commutated converter based high-voltage direct current(LCC-HVDC)transmission systems,the transformer saturation can induce harmonic instability,which poses a serious threat to the safe operation of the power system.However,the nonlinear characteristics of the power grids introduced by the transformer saturation considerably limit the application of the conventional analysis methods.To address the issue,this paper derives a linear model for the transformer saturation caused by the DC current due to the converter modulation.Afterwards,the nonlinear characteristics of power grids with the transformer saturation is described by a complex valued impedance matrix.Based on the derived impedance matrix,the system harmonic stability is analyzed and the mechanism of the transformer saturation induced harmonic instability is revealed.Finally,the sensitivity analysis is conducted to find the key factors that influence the system core saturation instability.The proposed impedance model is verified by the electromagnetic transient simulation,and the simulation results corroborate the effectiveness of the proposed impedance model.Index TermsLine commutated converter based high voltage direct current(LCC-HVDC),transformer saturation,harmonic instability,impedance model.展开更多
基金This work was supported in part by the National Natural Science Foundation of China(U1766210,51625702)Science and Technology Program of SGCC.
文摘This paper proposes a novel AC filter system for a line commutated converter high voltage DC(LCC-HVDC)transmission system.Through the coordination of the hybrid active power filters(APF)and the existing reactive compensation devices,the proposed filter system can not only enhance the suppression performance for LCC-HVDC harmonics,but also optimize the AC yard layout with reduced reactive power subbanks,reducing the cost of HVDC projects.The novel filter system adopts a serial passive resonance topology obtained by careful comparison of different APFs.A proper control scheme is then designed integrating the control strategy of the APF and impedance characteristics of the HVDC system,which is able to realize harmonic suppression and dynamic reactive power support simultaneously.In addition,a novel self-adaption digital low-pass filter algorithm is presented,which is used in the APF harmonic detecting step,enhancing both high precision and fast dynamic response.On the basis of a real HVDC project,the advantages of proposed filter system in harmonic suppression,reactive power regulation,and sub-banks reduction are simulated and demonstrated.
文摘In line commutated converter based high-voltage direct current(LCC-HVDC)transmission systems,the transformer saturation can induce harmonic instability,which poses a serious threat to the safe operation of the power system.However,the nonlinear characteristics of the power grids introduced by the transformer saturation considerably limit the application of the conventional analysis methods.To address the issue,this paper derives a linear model for the transformer saturation caused by the DC current due to the converter modulation.Afterwards,the nonlinear characteristics of power grids with the transformer saturation is described by a complex valued impedance matrix.Based on the derived impedance matrix,the system harmonic stability is analyzed and the mechanism of the transformer saturation induced harmonic instability is revealed.Finally,the sensitivity analysis is conducted to find the key factors that influence the system core saturation instability.The proposed impedance model is verified by the electromagnetic transient simulation,and the simulation results corroborate the effectiveness of the proposed impedance model.Index TermsLine commutated converter based high voltage direct current(LCC-HVDC),transformer saturation,harmonic instability,impedance model.