期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
FRT Control Method Including Islanding Detection in PCS Model for Photovoltaic Generation
1
作者 Miyazaki Takahiro Cheng Wai Tatt Yoshimura Kazuaki Taoka Hisao Kawasaki Shoji Matsuki Junya 《Journal of Energy and Power Engineering》 2013年第7期1388-1393,共6页
The experimental results by the simulated PV (photovoltaic) system for understanding the cause of disconnection when instantaneous voltage sag occurs are reported in this study. Moreover, it is understood that the P... The experimental results by the simulated PV (photovoltaic) system for understanding the cause of disconnection when instantaneous voltage sag occurs are reported in this study. Moreover, it is understood that the PCS with the voltage phase jump detection method which is one of the main causes of the disconnection. We modeled it in the simulation. When fault occurs, even though the residual voltage is more than 20% and the voltage sag time is within 1.0 s, the PCS disconnected by the voltage phase jump detection was confirmed in the simulation results. Ifa large number of PV systems are interconnected in the power system, this study is verified through the simulation that the interaction caused by the disconnection which generated by the voltage phase jump detection. This study is proposed threshold limit value of islanding detection. The validity of proposed method was verified through the simulation in this study. 展开更多
关键词 FRT function PCS islanding detection voltage sag voltage phase jump detection.
下载PDF
Residual current compensation for single-phase grounding fault in coal mine power network 被引量:3
2
作者 Jia Chenxi Wang Chonglin Du Guifu 《International Journal of Mining Science and Technology》 SCIE EI 2014年第2期213-218,共6页
The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding curren... The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced. 展开更多
关键词 Full compensation arc suppression co Residual current compensation Grounding current detection Zero sequence voltage detection
下载PDF
Self-diagnosis method for faulty modules on wireless sensor node
3
作者 赵军 陈祥光 +1 位作者 李智敏 吴磊 《Journal of Beijing Institute of Technology》 EI CAS 2013年第2期271-277,共7页
In order to diagnose the working status of each module on sensor node and make sure the wireless sensor networks (WSN) work properly, the components of sensor node and their working characteristics are studied. An o... In order to diagnose the working status of each module on sensor node and make sure the wireless sensor networks (WSN) work properly, the components of sensor node and their working characteristics are studied. An on-line fault self-diagnosis method for sensor node is proposed. First, a flexible fault sensing circuit is designed as a state detection module on sensor node. Second, a self- diagnosis algorithm is proposed based on the hardware design and the failure analysis on sensor node. Finally, in order to ensure the WSN reliability, the voltage changes of each module working statuses can be observed using the state detection module and the faulty module will be found out timely. The experimental results show that this self-diagnosis method is suitable to sensor nodes in WSN. 展开更多
关键词 voltage detection self-diagnose algorithm state detection module wireless sensor net- work
下载PDF
Application of new directional logic to improve DC side fault discrimination for high resistance faults in HVDC grids 被引量:7
4
作者 Naushath M.HALEEM Athula D.RAJAPAKSE 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第4期560-573,共14页
This paper proposes a simple and fast way to determine the direction of a fault in a multi-terminal high voltage direct current(HVDC) grid by comparing the rate of change of voltage(ROCOV) values at either side of the... This paper proposes a simple and fast way to determine the direction of a fault in a multi-terminal high voltage direct current(HVDC) grid by comparing the rate of change of voltage(ROCOV) values at either side of the di/dt limiting inductors at the line terminals. A local measurement based secure and fast protection method is implemented by supervising a basic ROCOV relay with a directional element. This directional information is also used to develop a slower communication based DC line protection scheme for detecting high resistance faults. The proposed protection scheme is applied to a multi-level modular converter based three-terminal HVDC grid and its security and sensitivity are evaluated through electromagnetic transient simulations. A methodology to set the protection thresholds considering the constraints imposed by the breaker technology and communication delays is also presented. With properly designed di/dt limiting inductors,the ability of clearing any DC transmission system fault before fault currents exceeds a given breaker capacity is demonstrated. 展开更多
关键词 Directional relay DC line protection Multiterminal HVDC grid protection Rate of change of voltage(ROCOV)based HVDC transmission fault detection
原文传递
上一页 1 下一页 到第