The experimental results by the simulated PV (photovoltaic) system for understanding the cause of disconnection when instantaneous voltage sag occurs are reported in this study. Moreover, it is understood that the P...The experimental results by the simulated PV (photovoltaic) system for understanding the cause of disconnection when instantaneous voltage sag occurs are reported in this study. Moreover, it is understood that the PCS with the voltage phase jump detection method which is one of the main causes of the disconnection. We modeled it in the simulation. When fault occurs, even though the residual voltage is more than 20% and the voltage sag time is within 1.0 s, the PCS disconnected by the voltage phase jump detection was confirmed in the simulation results. Ifa large number of PV systems are interconnected in the power system, this study is verified through the simulation that the interaction caused by the disconnection which generated by the voltage phase jump detection. This study is proposed threshold limit value of islanding detection. The validity of proposed method was verified through the simulation in this study.展开更多
The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding curren...The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced.展开更多
In order to diagnose the working status of each module on sensor node and make sure the wireless sensor networks (WSN) work properly, the components of sensor node and their working characteristics are studied. An o...In order to diagnose the working status of each module on sensor node and make sure the wireless sensor networks (WSN) work properly, the components of sensor node and their working characteristics are studied. An on-line fault self-diagnosis method for sensor node is proposed. First, a flexible fault sensing circuit is designed as a state detection module on sensor node. Second, a self- diagnosis algorithm is proposed based on the hardware design and the failure analysis on sensor node. Finally, in order to ensure the WSN reliability, the voltage changes of each module working statuses can be observed using the state detection module and the faulty module will be found out timely. The experimental results show that this self-diagnosis method is suitable to sensor nodes in WSN.展开更多
This paper proposes a simple and fast way to determine the direction of a fault in a multi-terminal high voltage direct current(HVDC) grid by comparing the rate of change of voltage(ROCOV) values at either side of the...This paper proposes a simple and fast way to determine the direction of a fault in a multi-terminal high voltage direct current(HVDC) grid by comparing the rate of change of voltage(ROCOV) values at either side of the di/dt limiting inductors at the line terminals. A local measurement based secure and fast protection method is implemented by supervising a basic ROCOV relay with a directional element. This directional information is also used to develop a slower communication based DC line protection scheme for detecting high resistance faults. The proposed protection scheme is applied to a multi-level modular converter based three-terminal HVDC grid and its security and sensitivity are evaluated through electromagnetic transient simulations. A methodology to set the protection thresholds considering the constraints imposed by the breaker technology and communication delays is also presented. With properly designed di/dt limiting inductors,the ability of clearing any DC transmission system fault before fault currents exceeds a given breaker capacity is demonstrated.展开更多
文摘The experimental results by the simulated PV (photovoltaic) system for understanding the cause of disconnection when instantaneous voltage sag occurs are reported in this study. Moreover, it is understood that the PCS with the voltage phase jump detection method which is one of the main causes of the disconnection. We modeled it in the simulation. When fault occurs, even though the residual voltage is more than 20% and the voltage sag time is within 1.0 s, the PCS disconnected by the voltage phase jump detection was confirmed in the simulation results. Ifa large number of PV systems are interconnected in the power system, this study is verified through the simulation that the interaction caused by the disconnection which generated by the voltage phase jump detection. This study is proposed threshold limit value of islanding detection. The validity of proposed method was verified through the simulation in this study.
基金The financial support from the National Natural Science Foundation of China (No. 51107143)
文摘The way of neutral point to earth via full compensation arc suppression coil can solve the problem of residual current compensation in coal mine power network effectively. Based on the analysis on the grounding current detection results of Xieqiao coal mine, the conclusion that harmonic component of grounding current is dominated by higher harmonics with complex harmonic sources in coal mine power network system was obtained. The influences of harmonic source type and fault point position on harmonic voltage and harmonic current were analyzed theoretically. The influences of earthed fault feeder detection result and the estimation errors of parameters to earth on residual current compensation were analyzed. A new thought of residual current prediction and the selections of model method and control method were proposed on this basis. The simulation results prove that harmonic amplitudes of zero sequence voltage and zero sequence current are determined by harmonic source type as well as fault point position in coal mine power network, and also prove that zero sequence voltage detection can avoid the unstable problem of coal mine power network system caused by undercompensation of capacitive current. Finally, the experimental device of full compensation arc suppression coil is introduced.
基金Supported by the Basic Research Foundation of Beijing Institute of Technology(200705422009)
文摘In order to diagnose the working status of each module on sensor node and make sure the wireless sensor networks (WSN) work properly, the components of sensor node and their working characteristics are studied. An on-line fault self-diagnosis method for sensor node is proposed. First, a flexible fault sensing circuit is designed as a state detection module on sensor node. Second, a self- diagnosis algorithm is proposed based on the hardware design and the failure analysis on sensor node. Finally, in order to ensure the WSN reliability, the voltage changes of each module working statuses can be observed using the state detection module and the faulty module will be found out timely. The experimental results show that this self-diagnosis method is suitable to sensor nodes in WSN.
文摘This paper proposes a simple and fast way to determine the direction of a fault in a multi-terminal high voltage direct current(HVDC) grid by comparing the rate of change of voltage(ROCOV) values at either side of the di/dt limiting inductors at the line terminals. A local measurement based secure and fast protection method is implemented by supervising a basic ROCOV relay with a directional element. This directional information is also used to develop a slower communication based DC line protection scheme for detecting high resistance faults. The proposed protection scheme is applied to a multi-level modular converter based three-terminal HVDC grid and its security and sensitivity are evaluated through electromagnetic transient simulations. A methodology to set the protection thresholds considering the constraints imposed by the breaker technology and communication delays is also presented. With properly designed di/dt limiting inductors,the ability of clearing any DC transmission system fault before fault currents exceeds a given breaker capacity is demonstrated.