This paper presents a unique novel design of the phase-shifted cascade high voltage inverter. Thehigh voltage inverter utilizes fewer power switches and supplies a balance load. The usage of phase shifttransformer and...This paper presents a unique novel design of the phase-shifted cascade high voltage inverter. Thehigh voltage inverter utilizes fewer power switches and supplies a balance load. The usage of phase shifttransformer and phase shifting SPWM ensures that input and output harmonic wave content is low and outputvoltage change (du/dt) has a low rate, meeting all the requirements of the power authorities. The most out-standing feature is the energy saving with very fast cost recovery.展开更多
This paper proposes a new concept of synthesized voltage vector to address dead-time effect issue for Finite Control Set Model Predictive Control(FCS-MPC)technique.For a voltage source inverter(VSI),dead-time is inevi...This paper proposes a new concept of synthesized voltage vector to address dead-time effect issue for Finite Control Set Model Predictive Control(FCS-MPC)technique.For a voltage source inverter(VSI),dead-time is inevitably inserted between the turn off and turn on instants of power devices to avoid short circuit phenomenon.The influence of dead-time leads to output voltage vector error of three-phase inverters.Furthermore,it will result in computing deviation in cost function,and will deteriorate the performance of the system if not properly dealt with.In this paper,the problem is clearly analyzed,and the solution to this issue is proposed by introducing a synthesized voltage vector.The proposed solution is verified by Hardware-in-the-loop(HiL)test in real time,and results validate the effectiveness of the proposed solution.展开更多
Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used t...Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients.展开更多
This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power osci...This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power oscillations and current distortions are inevitable.In the proposed strategy,the extended power theory is introduced to compute the power feedbacks together with the classical power theory.Based on the combination of the classical and extended power theory,the proposed strategy can achieve the sinusoidal current provision and the flexible regulation between three common targets,i.e.,constant active power,balanced current,and constant reactive power.Meanwhile,the proposed strategy is associated with a power limiter,which is capable to keep the currents under the pre-defined threshold and to compute the maximum apparent power for better utilization of the inverter capacity.With this power limiter,the rated inverter capacity is fully used for both the active and reactive power provisions under unbalanced grid faults.Using the proposed power regulation and limitation,the VSI can avoid overcurrent tripping and flexibly regulate its power under unbalanced grid faults.All the conclusions are verified by the real-time hardware-in-loop tests.展开更多
This paper presents a simple approach of a topology already known in the literature, applied in active power transfer from direct current source to any alternating current voltage source, whether the utility power or ...This paper presents a simple approach of a topology already known in the literature, applied in active power transfer from direct current source to any alternating current voltage source, whether the utility power or a voltage inverter that is forming an isolated AC grid. The photovoltaic inverter works as current controlled voltage source inverter that provides a sinusoidal current to the AC grid. The inverter is insulated from the grid by a transformer. The system is discussed and modeled. Simulation results of this application are presented and experimental results validate this topology.展开更多
This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (f...This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (finite set-model predictive control) strategy for a three-phase VSI for RES (renewable energy systems) applications is implemented. The renewable energy systems model is used in this paper to investigate the system performance when power is supplied to resistive-inductive load. With three different cases, the evaluation of the system is done. Firstly, the robustness of control strategy under variable DC-Link is done in terms of the THD (total harmonic distortion). Secondly, with one prediction step, the system performance is tested using different sampling time, and lastly, the dynamic response of the system with step change in the amplitude of the reference is investigated. The simulations and result analyses are carried out using Matlab/Simulink to test the effectiveness and robustness of FS-MPC for two-level VSI with AC filter for resistive-inductive load supplied by a renewable energy system.展开更多
In this manuscript it is proposed and demonstrated that how an ANFIS (Adaptive Neuro Fuzzy Inference System) can be used in the control of a Voltage Source Inverter (VSI) connected to the grid. Volatile changes in the...In this manuscript it is proposed and demonstrated that how an ANFIS (Adaptive Neuro Fuzzy Inference System) can be used in the control of a Voltage Source Inverter (VSI) connected to the grid. Volatile changes in the gird parameters rising by its variable demands and other related issues may humiliate the efficiency with which power can be injected into the grid. The system becomes a higher order one with the filters used at the terminal of the Voltage Source Inverter (VSI) along with the parameters of the grid which change from time to time. Single time tuned mathematical controllers like the PID variants are not suitable for such applications. Considering the increased order of the system and the associated non-linearity we have to look out for intelligent controllers. An ANFIS based control is found to be promising;the development and implementation of one such are demonstrated in this paper using the MATLAB SIMULINK platform and through experimental verification using the Reduced Instruction Set Computer (RISC) Microcontroller Advanced RISC Machine (ARM) processor as the central controller for the VSI.展开更多
The multiplicity of vector combinations for vectors of combined three-level inverters plays an important role, when deciding on the modulation scheme, to obtain minimum switching per inverter vector change, as describ...The multiplicity of vector combinations for vectors of combined three-level inverters plays an important role, when deciding on the modulation scheme, to obtain minimum switching per inverter vector change, as described in the next Section. This is not possible with reduced common-mode three-level inverter structure, obtained with a five-level cascaded H-bridge configuration, as the space vectors locations do not exhibit multiplicity. Moreover, the proposed configuration requires only two power supplies, whereas the scheme with the five-level H-bridge configuration requires six isolated power supplies.展开更多
The multiplicity of vector combinations for vectors of combined three-level inverters plays an important role, when deciding on the modulation scheme, to obtain minimum switching per inverter vector change, as describ...The multiplicity of vector combinations for vectors of combined three-level inverters plays an important role, when deciding on the modulation scheme, to obtain minimum switching per inverter vector change, as described in the next Section. This is not possible with reduced common-mode three-level inverter structure, obtained with a five-level cascaded H-bridge configuration, as the space vectors locations do not exhibit multiplicity. Moreover, the proposed configuration requires only two power supplies, whereas the scheme with the five-level H-bridge configuration requires six isolated power supplies.展开更多
Renewable energy has become important for electricity generation because of the high air pollution associated with conventional fossil-based energy systems.Conventional fossil-based power plants are gradually transiti...Renewable energy has become important for electricity generation because of the high air pollution associated with conventional fossil-based energy systems.Conventional fossil-based power plants are gradually transitioning by incorporating renewable energy sources,such as photovoltaic(PV)cells.In a PV system,an inverter converts DC power from solar panels to AC power required to serve common electrical loads.A conventional H-bridge inverter topology has several disadvantages,such as the voltage being not sinusoidal,switching the DC voltage and high common-mode voltage.The common-mode voltage can cause a large leaked capacitive current,which can result in undesirable operation in solar power applications.A common solution to this problem is the addition of a large filter to the input or output of an inverter.An inherent sinusoidal voltage source inverter based on a modified Cuk converter as its basic cell,which simultaneously generates a sinusoidal output voltage and a lower common-mode voltage,is proposed.The proposed topology does not require additional input or output filters.Analytical expressions are derived to confirm the operation of the proposed topology.Simulation results confirm the mathematical analysis.A laboratory-scale experiment is performed to verify the proposed inverter.展开更多
Presented field-circuit coupled adaptive time-stepping finite element method to study on permanent magnet linear synchronous motor (PMLSM) characteristics fed by SPWM voltage source inverter.In air-gap field where the...Presented field-circuit coupled adaptive time-stepping finite element method to study on permanent magnet linear synchronous motor (PMLSM) characteristics fed by SPWM voltage source inverter.In air-gap field where the direction or magnitude of the field is changing rapidly,the smallest elements are demanded due to high accuracy to use adaptive meshing technique.The co-simulation was used with the status space functions and time-step finite element functions,in which time-step of the status space functions was the smallest than finite element functions'.The magnitude relation of the normal elec- tromagnetic force and tangential electromagnetic force and the period were attained,and current curve was very abrupt at current zero area due to the bigger resistance and leak- age reactance,including main characteristics of motor voltage and velocity.The simulation results compare triumphantly with the experiments results.展开更多
The single-phase three-level voltage source inverter based on wavelet modulation(WM) is proposed.The WM technique is based on constructing a nondyadic-type multi-resolution analysis(MRA),which supports sampling contin...The single-phase three-level voltage source inverter based on wavelet modulation(WM) is proposed.The WM technique is based on constructing a nondyadic-type multi-resolution analysis(MRA),which supports sampling continuous-time sinusoidal signals in a nonuniform recurrent manner,and then reconstructing it by using inverter switching actions. In order to further improve the output voltage waveform and reduce harmonic distortion,the wavelet modulation is used to three-level inverter. The high magnitude of fundamental component and significantly reduced harmonic contents of the inverter output voltage can be achieved by using WM in the single-phase three-level voltage source inverter. Furthermore,the WM algorithm is implemented by using only one element government(EV) in DSP. The simulated and experimental results prove the accuracy and feasibility of the WM scheme for single-phase three-level voltage source inverter.展开更多
The output current harmonic distortion of a three-level inverter is less than the traditional twolevel inverter.The voltage stress of the semiconductor switch is low.A neutral point potential drift control method is p...The output current harmonic distortion of a three-level inverter is less than the traditional twolevel inverter.The voltage stress of the semiconductor switch is low.A neutral point potential drift control method is proposed to solve the problem of the neutral point potential drift of the three-level inverter.The interaction mechanism between the neutral point potential and the space voltage vector is presented.The small vector output by the inverter is found to be the root cause of the midpoint potential drift.It is found that the fluctuation of the midpoint potential could be suppressed by increasing the capacitance value of the inverter bus voltage stabilizing capacitor.Furthermore,it inhibits the fluctuation of the midpoint potential.The experimental results verify the efficiency and precision of the proposed method.展开更多
The main objective of this paper is to reduce the total harmonics in a single phase voltage source inverter using Artificial Bee Colony (ABC) optimization technique for critical load applications. Single phase inverte...The main objective of this paper is to reduce the total harmonics in a single phase voltage source inverter using Artificial Bee Colony (ABC) optimization technique for critical load applications. Single phase inverter is a non-linear load using power electronic components causing distortions in the load voltage and current wave patterns from the sinusoidal waveforms due to harmonics. The mapping state space model for a full bridge voltage source inverter was developed using output load resistance. An optimal ABC technique has been designed and optimized values are estimated using a full bridge voltage controlled inverter using Proportional Integral Algorithm. The MATLAB/SIMULINK tool and Experimental setup were implemented and their THD values were estimated. Also this ABC scheme is compared with the previous results such as PI Algorithm, Fuzzy logic controller and Neuro-fuzzy controllers. From the simulation and experimental results using ABC algorithm, it is observed that the total harmonics are mitigated considerably compared to previous results with respect to the power quality standards such as IEEE-519 and IEC 61000.展开更多
The generation of electricity based on renewable energy sources,parti-cularly Photovoltaic(PV)system has been greatly increased and it is simply insti-gated for both domestic and commercial uses.The power generated fr...The generation of electricity based on renewable energy sources,parti-cularly Photovoltaic(PV)system has been greatly increased and it is simply insti-gated for both domestic and commercial uses.The power generated from the PV system is erratic and hence there is a need for an efficient converter to perform the extraction of maximum power.An improved interleaved Single-ended Primary Inductor-Converter(SEPIC)converter is employed in proposed work to extricate most of power from renewable source.This proposed converter minimizes ripples,reduces electromagnetic interference due tofilter elements and the contin-uous input current improves the power output of PV panel.A Crow Search Algo-rithm(CSA)based Proportional Integral(PI)controller is utilized for controlling the converter switches effectively by optimizing the parameters of PI controller.The optimized PI controller reduces ripples present in Direct Current(DC)vol-tage,maintains constant voltage at proposed converter output and reduces over-shoots with minimum settling and rise time.This voltage is given to single phase grid via 1�Voltage Source Inverter(VSI).The command pulses of 1�VSI are produced by simple PI controller.The response of the proposed converter is thus improved with less input current.After implementing CSA based PI the efficiency of proposed converter obtained is 96%and the Total Harmonic Distor-tion(THD)is found to be 2:4%.The dynamics and closed loop operation is designed and modeled using MATLAB Simulink tool and its behavior is performed.展开更多
The 3Φinduction motor is a broadly used electric machine in industrial applications,which plays a vital role in industries because of having plenty of beneficial impacts like low cost and easiness but the problems lik...The 3Φinduction motor is a broadly used electric machine in industrial applications,which plays a vital role in industries because of having plenty of beneficial impacts like low cost and easiness but the problems like decrease in motor speed due to load,high consumption of current and high ripple occurrence of ripples have reduced its preferences.The ultimate objective of this study is to control change in motor speed due to load variations.An improved Trans Z Source Inverter(ΓZSI)with a clamping diode is employed to maintain constant input voltage,reduce ripples and voltage overshoot.To operate induction motor at rated speed,different controllers are used.The conventional Proportional-Inte-gral(PI)controller suffers from high settling time and maximum peak overshoot.To overcome these limitations,Fractional Order Proportional Integral Derivative(FOPID)controller optimized by Gray Wolf Optimization(GWO)technique is employed to provide better performance by eliminating maximum peak overshoot pro-blems.The proposed speed controller provides good dynamic response and controls the induction motor more effectively.The complete setup is implemented in MATLAB Simulation to verify the simulation results.The proposed approach provides optimal performance with high torque and speed along with less steady state error.展开更多
The application of LCL filters has become popular for inverters connected to the power grid due to their advantages in harmonic current reductions. However,the power grid in a distribution system is non-ideal, present...The application of LCL filters has become popular for inverters connected to the power grid due to their advantages in harmonic current reductions. However,the power grid in a distribution system is non-ideal, presenting itself as a voltage source with significant impedance. This means that an inverter using an LCL filter may interact with other grid-connected inverters via the nonideal grid. In this paper, damping optimization of LCLfilters to reduce this interaction is studied for a three-phase voltage source inverter(VSI). Simulation results show that resonant oscillation occurs in a distributed power grid, even if the VSI with an LCL filter is well designed for standalone applications. A small-signal analysis is performed to predict this stability problem and to locate the boundary of the instability using an impedance approach. Based on these analytical results, optimized damping of the LCLfilter can be designed. The oscillation phenomena and optimized damping design are verified by simulations and experimental measurements.展开更多
This paper proposes the optimum controller for shunt active filter(SAF)to mitigate the harmonics and maintain the power quality in the distribution system.It consists of shunt active filter,Voltage Source Inverter(VSI...This paper proposes the optimum controller for shunt active filter(SAF)to mitigate the harmonics and maintain the power quality in the distribution system.It consists of shunt active filter,Voltage Source Inverter(VSI),series inductor and DC bus and nonlinear load.The proposed hybrid approach is a combination of Particle Swarm Optimization(PSO)and Artificial Neural Network(ANN)termed as PSOANN.The PI controller gain parameters of kp and ki are optimized with the help of PSOANN.The PSOANN improves the accuracy of tuning the gain parameters under steady and dynamic load conditions;thereby it reduces the values of THD within the prescribed limits of IEEE 519.The PSO optimizes the dataset of terminal voltage and DC voltage present in shunt active filter for different load condition.The optimized dataset acts as the input for the controller to predict the optimal gain with minimal error and to generate the optimized control signal for the SAF.The proposed methodology is modelled and simulated with the help of MATLAB/Simulink platform and illustrated the few test cases considered for exhibiting the performance of proposed hybrid controller.The experimental results are measured with developed laboratory prototype and compared with the simulation results to validate the effectiveness of the proposed control methodology.展开更多
This paper deals with a combined test rig for a traction system in the laboratory environment.An experimental system was designed and implemented to verify the performance of the traction system for a metro train.For ...This paper deals with a combined test rig for a traction system in the laboratory environment.An experimental system was designed and implemented to verify the performance of the traction system for a metro train.For a highly accurate control of the system,a hybrid control algorithm combining vector control and slip frequency control was applied to control the traction inverter.The design method of the flywheels,which represent the equivalent model of the train moment inertia,was elaborated.A train runtime diagnosis system was completed by adopting the multifunction vehicle bus(MVB) protocol.The dynamic performance of the metro power traction system was emulated under the control of the train runtime diagnosis system.Using the combined test rig,the performances of the traction system in traction,braking,temperature rise,etc.,were verified through traction and breaking experiments.展开更多
The paper deals with the designing of an electric drive system used for hybrid electric vehicles. The driving system is realized with an induction motor and a voltage source inverter. Specifically, the application is ...The paper deals with the designing of an electric drive system used for hybrid electric vehicles. The driving system is realized with an induction motor and a voltage source inverter. Specifically, the application is for a series hybrid vehicle powered by electric storage batteries charged by solar batteries. In the first part of the paper the designing of the electric storage batteries and of the photoelectric system is presented. In the second part of the paper some aspects regarding the designing of the induction motor are presented. Then some aspects concerning the voltage source inverter designing are exposed.展开更多
文摘This paper presents a unique novel design of the phase-shifted cascade high voltage inverter. Thehigh voltage inverter utilizes fewer power switches and supplies a balance load. The usage of phase shifttransformer and phase shifting SPWM ensures that input and output harmonic wave content is low and outputvoltage change (du/dt) has a low rate, meeting all the requirements of the power authorities. The most out-standing feature is the energy saving with very fast cost recovery.
文摘This paper proposes a new concept of synthesized voltage vector to address dead-time effect issue for Finite Control Set Model Predictive Control(FCS-MPC)technique.For a voltage source inverter(VSI),dead-time is inevitably inserted between the turn off and turn on instants of power devices to avoid short circuit phenomenon.The influence of dead-time leads to output voltage vector error of three-phase inverters.Furthermore,it will result in computing deviation in cost function,and will deteriorate the performance of the system if not properly dealt with.In this paper,the problem is clearly analyzed,and the solution to this issue is proposed by introducing a synthesized voltage vector.The proposed solution is verified by Hardware-in-the-loop(HiL)test in real time,and results validate the effectiveness of the proposed solution.
文摘Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients.
基金This work is supported by the National Key Research and Development Program of China under Project 2021YFB2601600。
文摘This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power oscillations and current distortions are inevitable.In the proposed strategy,the extended power theory is introduced to compute the power feedbacks together with the classical power theory.Based on the combination of the classical and extended power theory,the proposed strategy can achieve the sinusoidal current provision and the flexible regulation between three common targets,i.e.,constant active power,balanced current,and constant reactive power.Meanwhile,the proposed strategy is associated with a power limiter,which is capable to keep the currents under the pre-defined threshold and to compute the maximum apparent power for better utilization of the inverter capacity.With this power limiter,the rated inverter capacity is fully used for both the active and reactive power provisions under unbalanced grid faults.Using the proposed power regulation and limitation,the VSI can avoid overcurrent tripping and flexibly regulate its power under unbalanced grid faults.All the conclusions are verified by the real-time hardware-in-loop tests.
文摘This paper presents a simple approach of a topology already known in the literature, applied in active power transfer from direct current source to any alternating current voltage source, whether the utility power or a voltage inverter that is forming an isolated AC grid. The photovoltaic inverter works as current controlled voltage source inverter that provides a sinusoidal current to the AC grid. The inverter is insulated from the grid by a transformer. The system is discussed and modeled. Simulation results of this application are presented and experimental results validate this topology.
文摘This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (finite set-model predictive control) strategy for a three-phase VSI for RES (renewable energy systems) applications is implemented. The renewable energy systems model is used in this paper to investigate the system performance when power is supplied to resistive-inductive load. With three different cases, the evaluation of the system is done. Firstly, the robustness of control strategy under variable DC-Link is done in terms of the THD (total harmonic distortion). Secondly, with one prediction step, the system performance is tested using different sampling time, and lastly, the dynamic response of the system with step change in the amplitude of the reference is investigated. The simulations and result analyses are carried out using Matlab/Simulink to test the effectiveness and robustness of FS-MPC for two-level VSI with AC filter for resistive-inductive load supplied by a renewable energy system.
文摘In this manuscript it is proposed and demonstrated that how an ANFIS (Adaptive Neuro Fuzzy Inference System) can be used in the control of a Voltage Source Inverter (VSI) connected to the grid. Volatile changes in the gird parameters rising by its variable demands and other related issues may humiliate the efficiency with which power can be injected into the grid. The system becomes a higher order one with the filters used at the terminal of the Voltage Source Inverter (VSI) along with the parameters of the grid which change from time to time. Single time tuned mathematical controllers like the PID variants are not suitable for such applications. Considering the increased order of the system and the associated non-linearity we have to look out for intelligent controllers. An ANFIS based control is found to be promising;the development and implementation of one such are demonstrated in this paper using the MATLAB SIMULINK platform and through experimental verification using the Reduced Instruction Set Computer (RISC) Microcontroller Advanced RISC Machine (ARM) processor as the central controller for the VSI.
文摘The multiplicity of vector combinations for vectors of combined three-level inverters plays an important role, when deciding on the modulation scheme, to obtain minimum switching per inverter vector change, as described in the next Section. This is not possible with reduced common-mode three-level inverter structure, obtained with a five-level cascaded H-bridge configuration, as the space vectors locations do not exhibit multiplicity. Moreover, the proposed configuration requires only two power supplies, whereas the scheme with the five-level H-bridge configuration requires six isolated power supplies.
文摘The multiplicity of vector combinations for vectors of combined three-level inverters plays an important role, when deciding on the modulation scheme, to obtain minimum switching per inverter vector change, as described in the next Section. This is not possible with reduced common-mode three-level inverter structure, obtained with a five-level cascaded H-bridge configuration, as the space vectors locations do not exhibit multiplicity. Moreover, the proposed configuration requires only two power supplies, whereas the scheme with the five-level H-bridge configuration requires six isolated power supplies.
基金Supported by Institut Teknologi Bandung(Grant No.223/IT1.B07.1/TA.00/2022)。
文摘Renewable energy has become important for electricity generation because of the high air pollution associated with conventional fossil-based energy systems.Conventional fossil-based power plants are gradually transitioning by incorporating renewable energy sources,such as photovoltaic(PV)cells.In a PV system,an inverter converts DC power from solar panels to AC power required to serve common electrical loads.A conventional H-bridge inverter topology has several disadvantages,such as the voltage being not sinusoidal,switching the DC voltage and high common-mode voltage.The common-mode voltage can cause a large leaked capacitive current,which can result in undesirable operation in solar power applications.A common solution to this problem is the addition of a large filter to the input or output of an inverter.An inherent sinusoidal voltage source inverter based on a modified Cuk converter as its basic cell,which simultaneously generates a sinusoidal output voltage and a lower common-mode voltage,is proposed.The proposed topology does not require additional input or output filters.Analytical expressions are derived to confirm the operation of the proposed topology.Simulation results confirm the mathematical analysis.A laboratory-scale experiment is performed to verify the proposed inverter.
基金National Natural Sciences Foundation(60474043)Henan Province Science Fund for Distinguished Young Scholars(0412002200)Henan Province Major Projects(0223025300)
文摘Presented field-circuit coupled adaptive time-stepping finite element method to study on permanent magnet linear synchronous motor (PMLSM) characteristics fed by SPWM voltage source inverter.In air-gap field where the direction or magnitude of the field is changing rapidly,the smallest elements are demanded due to high accuracy to use adaptive meshing technique.The co-simulation was used with the status space functions and time-step finite element functions,in which time-step of the status space functions was the smallest than finite element functions'.The magnitude relation of the normal elec- tromagnetic force and tangential electromagnetic force and the period were attained,and current curve was very abrupt at current zero area due to the bigger resistance and leak- age reactance,including main characteristics of motor voltage and velocity.The simulation results compare triumphantly with the experiments results.
基金Sponsored by the National Natural Science Foundation of China(Grant No.51107016)
文摘The single-phase three-level voltage source inverter based on wavelet modulation(WM) is proposed.The WM technique is based on constructing a nondyadic-type multi-resolution analysis(MRA),which supports sampling continuous-time sinusoidal signals in a nonuniform recurrent manner,and then reconstructing it by using inverter switching actions. In order to further improve the output voltage waveform and reduce harmonic distortion,the wavelet modulation is used to three-level inverter. The high magnitude of fundamental component and significantly reduced harmonic contents of the inverter output voltage can be achieved by using WM in the single-phase three-level voltage source inverter. Furthermore,the WM algorithm is implemented by using only one element government(EV) in DSP. The simulated and experimental results prove the accuracy and feasibility of the WM scheme for single-phase three-level voltage source inverter.
基金the National Natural Science Foundation of China(No.51407007)。
文摘The output current harmonic distortion of a three-level inverter is less than the traditional twolevel inverter.The voltage stress of the semiconductor switch is low.A neutral point potential drift control method is proposed to solve the problem of the neutral point potential drift of the three-level inverter.The interaction mechanism between the neutral point potential and the space voltage vector is presented.The small vector output by the inverter is found to be the root cause of the midpoint potential drift.It is found that the fluctuation of the midpoint potential could be suppressed by increasing the capacitance value of the inverter bus voltage stabilizing capacitor.Furthermore,it inhibits the fluctuation of the midpoint potential.The experimental results verify the efficiency and precision of the proposed method.
文摘The main objective of this paper is to reduce the total harmonics in a single phase voltage source inverter using Artificial Bee Colony (ABC) optimization technique for critical load applications. Single phase inverter is a non-linear load using power electronic components causing distortions in the load voltage and current wave patterns from the sinusoidal waveforms due to harmonics. The mapping state space model for a full bridge voltage source inverter was developed using output load resistance. An optimal ABC technique has been designed and optimized values are estimated using a full bridge voltage controlled inverter using Proportional Integral Algorithm. The MATLAB/SIMULINK tool and Experimental setup were implemented and their THD values were estimated. Also this ABC scheme is compared with the previous results such as PI Algorithm, Fuzzy logic controller and Neuro-fuzzy controllers. From the simulation and experimental results using ABC algorithm, it is observed that the total harmonics are mitigated considerably compared to previous results with respect to the power quality standards such as IEEE-519 and IEC 61000.
文摘The generation of electricity based on renewable energy sources,parti-cularly Photovoltaic(PV)system has been greatly increased and it is simply insti-gated for both domestic and commercial uses.The power generated from the PV system is erratic and hence there is a need for an efficient converter to perform the extraction of maximum power.An improved interleaved Single-ended Primary Inductor-Converter(SEPIC)converter is employed in proposed work to extricate most of power from renewable source.This proposed converter minimizes ripples,reduces electromagnetic interference due tofilter elements and the contin-uous input current improves the power output of PV panel.A Crow Search Algo-rithm(CSA)based Proportional Integral(PI)controller is utilized for controlling the converter switches effectively by optimizing the parameters of PI controller.The optimized PI controller reduces ripples present in Direct Current(DC)vol-tage,maintains constant voltage at proposed converter output and reduces over-shoots with minimum settling and rise time.This voltage is given to single phase grid via 1�Voltage Source Inverter(VSI).The command pulses of 1�VSI are produced by simple PI controller.The response of the proposed converter is thus improved with less input current.After implementing CSA based PI the efficiency of proposed converter obtained is 96%and the Total Harmonic Distor-tion(THD)is found to be 2:4%.The dynamics and closed loop operation is designed and modeled using MATLAB Simulink tool and its behavior is performed.
文摘The 3Φinduction motor is a broadly used electric machine in industrial applications,which plays a vital role in industries because of having plenty of beneficial impacts like low cost and easiness but the problems like decrease in motor speed due to load,high consumption of current and high ripple occurrence of ripples have reduced its preferences.The ultimate objective of this study is to control change in motor speed due to load variations.An improved Trans Z Source Inverter(ΓZSI)with a clamping diode is employed to maintain constant input voltage,reduce ripples and voltage overshoot.To operate induction motor at rated speed,different controllers are used.The conventional Proportional-Inte-gral(PI)controller suffers from high settling time and maximum peak overshoot.To overcome these limitations,Fractional Order Proportional Integral Derivative(FOPID)controller optimized by Gray Wolf Optimization(GWO)technique is employed to provide better performance by eliminating maximum peak overshoot pro-blems.The proposed speed controller provides good dynamic response and controls the induction motor more effectively.The complete setup is implemented in MATLAB Simulation to verify the simulation results.The proposed approach provides optimal performance with high torque and speed along with less steady state error.
基金supported by National Natural Science Foundation of China(No.51507118)by Open Fund of State Key Laboratory of Operation and Control of Renewable Energy and Storage Systems,China Electric Power Research Institute(Research on renewable energy power generation grid-connected converter fault tolerance evaluation method
文摘The application of LCL filters has become popular for inverters connected to the power grid due to their advantages in harmonic current reductions. However,the power grid in a distribution system is non-ideal, presenting itself as a voltage source with significant impedance. This means that an inverter using an LCL filter may interact with other grid-connected inverters via the nonideal grid. In this paper, damping optimization of LCLfilters to reduce this interaction is studied for a three-phase voltage source inverter(VSI). Simulation results show that resonant oscillation occurs in a distributed power grid, even if the VSI with an LCL filter is well designed for standalone applications. A small-signal analysis is performed to predict this stability problem and to locate the boundary of the instability using an impedance approach. Based on these analytical results, optimized damping of the LCLfilter can be designed. The oscillation phenomena and optimized damping design are verified by simulations and experimental measurements.
文摘This paper proposes the optimum controller for shunt active filter(SAF)to mitigate the harmonics and maintain the power quality in the distribution system.It consists of shunt active filter,Voltage Source Inverter(VSI),series inductor and DC bus and nonlinear load.The proposed hybrid approach is a combination of Particle Swarm Optimization(PSO)and Artificial Neural Network(ANN)termed as PSOANN.The PI controller gain parameters of kp and ki are optimized with the help of PSOANN.The PSOANN improves the accuracy of tuning the gain parameters under steady and dynamic load conditions;thereby it reduces the values of THD within the prescribed limits of IEEE 519.The PSO optimizes the dataset of terminal voltage and DC voltage present in shunt active filter for different load condition.The optimized dataset acts as the input for the controller to predict the optimal gain with minimal error and to generate the optimized control signal for the SAF.The proposed methodology is modelled and simulated with the help of MATLAB/Simulink platform and illustrated the few test cases considered for exhibiting the performance of proposed hybrid controller.The experimental results are measured with developed laboratory prototype and compared with the simulation results to validate the effectiveness of the proposed control methodology.
基金supported by the Innovation Funds for Technology Based Firms (09C26214301971)
文摘This paper deals with a combined test rig for a traction system in the laboratory environment.An experimental system was designed and implemented to verify the performance of the traction system for a metro train.For a highly accurate control of the system,a hybrid control algorithm combining vector control and slip frequency control was applied to control the traction inverter.The design method of the flywheels,which represent the equivalent model of the train moment inertia,was elaborated.A train runtime diagnosis system was completed by adopting the multifunction vehicle bus(MVB) protocol.The dynamic performance of the metro power traction system was emulated under the control of the train runtime diagnosis system.Using the combined test rig,the performances of the traction system in traction,braking,temperature rise,etc.,were verified through traction and breaking experiments.
文摘The paper deals with the designing of an electric drive system used for hybrid electric vehicles. The driving system is realized with an induction motor and a voltage source inverter. Specifically, the application is for a series hybrid vehicle powered by electric storage batteries charged by solar batteries. In the first part of the paper the designing of the electric storage batteries and of the photoelectric system is presented. In the second part of the paper some aspects regarding the designing of the induction motor are presented. Then some aspects concerning the voltage source inverter designing are exposed.