This article is based on a recent model specifically defining magnetic field values around electrical wires. With this model, calculations of field around parallel wires were obtained. Now, this model is extended with...This article is based on a recent model specifically defining magnetic field values around electrical wires. With this model, calculations of field around parallel wires were obtained. Now, this model is extended with the new concept of magnetic equipotential surface to magnetic field curves around crossing wires. Cases of single, double, and triple wires are described. Subsequent article will be conducted for more general scenarios where wires are neither infinite nor parallel.展开更多
The role played by equipotential connection in lightning protection was summarized in terms of lightning protection,static electricity,electromagnetic shielding,protection from electric shocks,and earth fault protecti...The role played by equipotential connection in lightning protection was summarized in terms of lightning protection,static electricity,electromagnetic shielding,protection from electric shocks,and earth fault protection.In addition,drawbacks of independent grounding and common grounding were concluded.According to standards and researches,such as Building Lightning Protection Design Standard (GB50057-2010),further demands and rules of equipotential connection in lightning protection engineering were proposed,providing references for lightning prevention design,construction and examination by related scientific workers and staffs.展开更多
提出了在等电位工作状态下校准多元感应分流器(multiple inductive current divider,MICD)的1种方法。在校准装置中加入由跟随器和电阻组成的I/V变换器,以使MICD各支路间的电流比例与其工作状态保持一致;用参考电流互感器(CT)提供独立...提出了在等电位工作状态下校准多元感应分流器(multiple inductive current divider,MICD)的1种方法。在校准装置中加入由跟随器和电阻组成的I/V变换器,以使MICD各支路间的电流比例与其工作状态保持一致;用参考电流互感器(CT)提供独立的参考电流,以避免影响支路电流的比例关系。在20、55、400 Hz及1 kHz下对11支路MICD校准所得10:1电流比例的比值差合成标准不确定度优于0.2μA/A,相位差合成标准不确定度优于1.5μrad。展开更多
文摘This article is based on a recent model specifically defining magnetic field values around electrical wires. With this model, calculations of field around parallel wires were obtained. Now, this model is extended with the new concept of magnetic equipotential surface to magnetic field curves around crossing wires. Cases of single, double, and triple wires are described. Subsequent article will be conducted for more general scenarios where wires are neither infinite nor parallel.
文摘The role played by equipotential connection in lightning protection was summarized in terms of lightning protection,static electricity,electromagnetic shielding,protection from electric shocks,and earth fault protection.In addition,drawbacks of independent grounding and common grounding were concluded.According to standards and researches,such as Building Lightning Protection Design Standard (GB50057-2010),further demands and rules of equipotential connection in lightning protection engineering were proposed,providing references for lightning prevention design,construction and examination by related scientific workers and staffs.