Volumetric-modulated arc therapy vs c-IMRT in esophageal cancer:A treatment planning comparison 被引量:36
1
作者 Li Yin Hao Wu +8 位作者 Jian Gong Jian-Hao Geng Fan Jiang An-Hui Shi Rong Yu Yong-Heng Li Shu-Kui Han Bo Xu Guang-Ying Zhu 《World Journal of Gastroenterology》 SCIE CAS CSCD 2012年第37期5266-5275,共10页
AIM: To compare the volumetric-modulated arc ther- apy (VMAT) plans with conventional sliding window intensity-modulated radiotherapy (c-IMRT) plans in esophageal cancer (EC). METHODS: Twenty patients with EC ... AIM: To compare the volumetric-modulated arc ther- apy (VMAT) plans with conventional sliding window intensity-modulated radiotherapy (c-IMRT) plans in esophageal cancer (EC). METHODS: Twenty patients with EC were selected, including 5 cases located in the cervical, the upper, the middle and the lower thorax, respectively. Five plans were generated with the eclipse planning sys- tem: three using c-IMRT with 5 fields (5F), 7 fields (7F) and 9 fields (gF), and two using VMAT with a single arc (1A) and double arcs (2A). The treatment plans were designed to deliver a dose of 60 Gy to the plan-ning target volume (PTV) with the same constrains in a 2.0 Gy daily fraction, 5 d a week. Plans were normal- ized to 95% of the PTV that received 100% of the pre- scribed dose. We examined the dose-volume histogram parameters of PTV and the organs at risk (OAR) such as lungs, spinal cord and heart. Monitor units (MU) and normal tissue complication probability (NTCP) of OAR were also reported. RESULTS: Both c-IMRT and VMAT plans resulted in abundant dose coverage of PTV for EC of different Io- cations. The dose conformity to PTV was improved as the number of field in c-IMRT or rotating arc in VMAT was increased. The doses to PTV and OAR in VMAT plans were not statistically different in comparison with c-IMRT plans, with the following exceptions: in cervical and upper thoracic EC, the conformity index (CI) was higher in VMAT (1A 0.78 and 2A 0.8) than in c-IMRT (5F 0.62, 7F 0.66 and 9F 0.73) and homogeneity was slightly better in c-IMRT (7F 1.09 and 9F 1.07) than in VMAT (1A 1,1 and 2A 1.09), Lung V30 was lower in VMAT (1A 12.52 and 2A 12.29) than in c-IMRT (7F 14.35 and 9F 14.81). The humeral head doses were significantly increased in VMAT as against c-IMRT. In the middle and lower thoracic EC, CI in VMAT (1A 0.76 and 2A 0.74) was higher than in c-IMRT (5F 0.63 Gy and 7F 0.67 Gy), and homogeneity was almost similar between VMAT and c-IMRT. V20 (2A 21.49 Gy vs 7F 24.59 Gy and 9F 24.16 Gy) and V30 (2A 9.73 Gy vs 5F 12.61 Gy, 7F 11.5 Gy and 9F 11.37 Gy) of lungs in VMAT were lower than in c-IMRT, but low doses to lungs (V5 and Vl0) were increased. V30 (1A 48.12 Gy vs 5F 59.2 Gy, 7F 58.59 Gy and 9F 57.2 Gy), V40 and V50 of heart in VMAT was lower than in c-IMRT. MUs in VMAT plans were significantly reduced in comparison with c-IMRT, maximum doses to the spinal cord and mean doses of lungs were similar between the two techniques. NTCP of spinal cord was 0 for all cases. NTCP of lungs and heart in VMAT were lower than in c-IMRT. The advantage of VMAT plan was enhanced by doubling the arc. CONCLUSION: Compared with c-IMRT, VMAT, especial- ly the 2A, slightly improves the OAR dose sparing, such as lungs and heart, and reduces NTCP and MU with a better PTV coverage. 展开更多
关键词 Esophageal cancer Treatment planning Intensity modulated radiotherapy volumetric modulat-ed arc radiotherapy Normal tissue complication prob-ability
下载PDF
Dosimetry Comparison between Volumetric Modulated Arc Therapy with RapidArc and Fixed Field Dynamic IMRT for Local-Regionally Advanced Nasopharyngeal Carcinoma 被引量:7
2
作者 Bao-min Zheng Xiao-xia Dong +3 位作者 Hao Wu You-jia Duan Shu-kui Han Yan Sun 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2011年第4期259-264,共6页
Objective: A dosimetric study was performed to evaluate the performance of volumetric modulated arc radiotherapy with RapidArc on locally advanced nasopharyngeal carcinoma (NPC). Methods: The CT scan data sets of 20 p... Objective: A dosimetric study was performed to evaluate the performance of volumetric modulated arc radiotherapy with RapidArc on locally advanced nasopharyngeal carcinoma (NPC). Methods: The CT scan data sets of 20 patients of locally advanced NPC were selected randomly. The plans were managed using volumetric modulated arc with RapidArc and fixed nine-field coplanar dynamic intensity-modulated radiotherapy (IMRT) for these patients. The dosimetry of the planning target volumes (PTV), the organs at risk (OARs) and the healthy tissue were evaluated. The dose prescription was set to 70 Gy to the primary tumor and 60 Gy to the clinical target volumes (CTV) in 33 fractions. Each fraction applied daily, five fractions per week. The monitor unit (MU) values and the delivery time were scored to evaluate the expected treatment efficiency. Results: Both techniques had reached clinical treatment’s requirement. The mean dose (Dmean), maximum dose (Dmax) and minimum dose (Dmin) in RapidArc and fixed field IMRT for PTV were 68.4±0.6 Gy, 74.8±0.9 Gy and 56.8±1.1 Gy; and 67.6±0.6 Gy, 73.8±0.4 Gy and 57.5±0.6 Gy (P<0.05), respectively. Homogeneity index was 78.85±1.29 in RapidArc and 80.34±0.54 (P<0.05) in IMRT. The conformity index (CI: 95%) was 0.78±0.01 for both techniques (P>0.05). Compared to IMRT, RapidArc allowed a reduction of Dmean to the brain stem, mandible and optic nerves of 14.1% (P<0.05), 5.6% (P<0.05) and 12.2% (P<0.05), respectively. For the healthy tissue and the whole absorbed dose, Dmean of RapidArc was reduced by 3.6% (P<0.05), and 3.7% (P<0.05), respectively. The Dmean to the parotids, the spinal cord and the lens had no statistical difference among them. The mean MU values of RapidArc and IMRT were 550 and 1,379. The mean treatment time of RapidArc and IMRT was 165 s and 447 s. Compared to IMRT, the delivery time and the MU values of RapidArc were reduced by 63% and 60%, respectively. Conclusion: For locally advanced NPC, both RapidArc and IMRT reached the clinic requirement. The target volume coverage was similar for the different techniques. The RapidArc technique showed some improvements in OARs and other tissue sparing while using reduced MUs and delivery time. 展开更多
关键词 volumetric modulated arc therapy Intensity-modulated radiotherapy DOSIMETRY Target volume Nasopharyngeal carcinoma
下载PDF
Helical tomotherapy and volumetric modulated arc therapy:New therapeutic arms in the breast cancer radiotherapy 被引量:7
3
作者 Olivier Lauche Youlia M Kirova +8 位作者 Pascal Fenoglietto Emilie Costa Claire Lemanski Celine Bourgier Olivier Riou David Tiberi Francois Campana Alain Fourquet David Azria 《World Journal of Radiology》 CAS 2016年第8期735-742,共8页
AIM To analyse clinical and dosimetric results of helical tomotherapy(HT) and volumetric modulated arc therapy(VMAT) in complex adjuvant breast and nodes irradiation.METHODS Seventy-three patients were included(31 HT ... AIM To analyse clinical and dosimetric results of helical tomotherapy(HT) and volumetric modulated arc therapy(VMAT) in complex adjuvant breast and nodes irradiation.METHODS Seventy-three patients were included(31 HT and 42 VMAT). Dose were 63.8 Gy(HT) and 63.2 Gy(VMAT) in the tumour bed, 52.2 Gy in the breast, 50.4 Gy in supraclavicular nodes(SCN) and internal mammary chain(IMC) with HT and 52.2 Gy and 49.3 Gy in IMC and SCN with VMAT in 29 fractions. Margins to particle tracking velocimetry were greater in the VMAT cohort(7 mm vs 5 mm).RESULTS For the HT cohort, the coverage of clinical target volumes was as follows: Tumour bed: 99.4% ± 2.4%; breast: 98.4% ± 4.3%; SCN: 99.5% ± 1.2%; IMC:96.5% ± 13.9%. For the VMAT cohort, the coverage was as follows: Tumour bed: 99.7% ± 0.5%, breast: 99.3% ± 0.7%; SCN: 99.6% ± 1.4%; IMC: 99.3% ± 3%. For ipsilateral lung, Dmean and V20 were 13.6 ± 1.2 Gy, 21.1% ± 5%(HT) and 13.6 ± 1.4 Gy, 20.1% ± 3.2%(VMAT). Dmean and V30 of the heart were 7.4 ± 1.4 Gy, 1% ± 1%(HT) and 10.3 ± 4.2 Gy, 2.5% ± 3.9%(VMAT). For controlateral breast Dmean was 3.6 ± 0.2 Gy(HT) and 4.6 ± 0.9 Gy(VMAT). Acute skin toxicity grade 3 was 5% in the two cohorts.CONCLUSION HT and VMAT in complex adjuvant breast irradiation allow a good coverage of target volumes with an acceptable acute tolerance. A longer follow-up is needed to assess the impact of low doses to healthy tissues. 展开更多
关键词 Three-dimensional conformal radiotherapy Intensity modulated radiation therapy TOXICITY Helical tomotherapy volumetric modulated arc therapy Breast cancer radiotherapy
下载PDF
Partial and Full Arc Volumetric Modulated Arc Therapy in Lung Cancer Stereotactic Body Radiotherapy with Different Definitions of Internal Target Volume Based on 4D CT 被引量:2
4
作者 Wu Wang Didi Chen +5 位作者 Ce Han Xiaomin Zheng Yongqiang Zhou Changfei Gong Congying Xie Xiance Jin 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2018年第4期491-502,共12页
Purpose: To investigate the feasibility of partial arc volumetric modulated arc therapy (VMAT) in lung cancer stereotactic body radiotherapy (SBRT), as well the volumetric and dosimetric effects of different internal ... Purpose: To investigate the feasibility of partial arc volumetric modulated arc therapy (VMAT) in lung cancer stereotactic body radiotherapy (SBRT), as well the volumetric and dosimetric effects of different internal target volume (ITV) definitions with 4D CT. Methods: Fourteen patients with primary and metastatic lung cancer underwent SBRT were enrolled. Full and partial arc VMAT plans were generated with four different ITVs: ITVall, ITVMIP, ITVAIP and ITV2phases, representing ITVs generated from all 10 respiratory phases, maximum intensity projection (MIP), average intensity projection (AIP), and 2 extreme respiratory phases. Volumetric and dosimetric differences, as well as MU and delivery time were investigated. Results: Partial arc VMAT irradiated more dose at 2 cm away from planning target volume (PTV) (P = 0.002), however, it achieved better protection on mean lung dose , lung V5, spinal cord, heart and esophagus compared with full arc VMAT. The average MU and delivery time of partial arc VMAT were 240 and 1.6 min less than those of full arc VMAT. There were no significant differences on target coverage and organ at risks (OARs) sparing among four ITVs. The average percent volume differences of ITVMIP, ITVAIP and ITV2phases to ITVall were 8.6%, 13.4%, and 25.2%, respectively. Conclusions: Although partial arc VMAT delivered more dose 2 cm out of PTV, it decreases the dose to lung, spinal cord, and esophagus, as well decreased the total MU and delivery time compared with full arc VMAT without sacrificing target coverage. Partial arc VMAT was feasible and more efficient for lung SBRT. 展开更多
关键词 Lung Cancer STEREOTACTIC Body RADIOTHERAPY Four Dimensional COMPUTED Tomography Internal Target Volume volumetric modulated arc Therapy
下载PDF
A prospective trial of volumetric intensity-modulated arc therapy vs conventional intensity modulated radiation therapy in advanced head and neck cancer 被引量:2
5
作者 Simon D Fung-Kee-Fung Rachel Hackett +2 位作者 Lee Hales Graham Warren Anurag K Singh 《World Journal of Clinical Oncology》 CAS 2012年第4期57-62,共6页
AIM: To prospectively compare volumetric intensitymodulated arc therapy(VMAT) and conventional intensity-modulated radiation therapy(IMRT) in coverage of planning target volumes and avoidance of multiple organs at ris... AIM: To prospectively compare volumetric intensitymodulated arc therapy(VMAT) and conventional intensity-modulated radiation therapy(IMRT) in coverage of planning target volumes and avoidance of multiple organs at risk(OARs) in patients undergoing definitive chemoradiotherapy for advanced(stage Ⅲ or Ⅳ)squamous cell cancer of the head and neck. METHODS: Computed tomography scans of 20 patients with advanced tumors of the larynx, naso-, oroand hypopharynx were prospectively planned using IMRT(7 field) and VMAT using two arcs. Calculated doses to planning target volume(PTV) and OAR were compared between IMRT and VMAT plans. Dose-volume histograms(DVH) were utilized to obtain calculated doses to PTV and OAR, including parotids, cochlea,spinal cord, brainstem, anterior tongue, pituitary and brachial plexus. DVH's for all structures were compared between IMRT and VMAT plans. In addition the planswere compared for dose conformity and homogeneity. The final treatment plan was chosen by the treating radiation oncologist. RESULTS: VMAT was chosen as the ultimate plan in 18 of 20 patients(90%) because the plans were thought to be otherwise clinically equivalent. The IMRT plan was chosen in 2 of 20 patients because the VMAT plan produced concentric irradiation of the cord which was not overcome even with an avoidance structure. For all patients, VMAT plans had a lower number of average monitor units on average(MU = 542.85) than IMRT plans(MU = 1612.58)(P < 0.001). Using the conformity index(CI), defined as the 95% isodose volume divided by the PTV, the IMRT plan was more conformal with a lower conformity index(CI = 1.61) than the VMAT plan(CI = 2.00)(P = 0.003). Dose homogeneity, as measured by average standard deviation of dose distribution over the PTV, was not different with VMAT(1.45 Gy) or IMRT(1.73 Gy)(P = 0.069). There were no differences in sparing organs at risk.CONCLUSION: In this prospective study, VMAT plans were chosen over IMRT 90% of the time. Compared to IMRT, VMAT plans used only one third of the MUs, had shorter treatment times, and similar sparing of OAR. Overall, VMAT provided similar dose homogeneity but less conformity in PTV irradiation compared to IMRT. This difference in conformity was not clinically significant. 展开更多
关键词 volumetric INTENSITY-modulated arc THERAPY INTENSITY-modulated radiation THERAPY Target COVERAGE ORGANS at risk
下载PDF
A dosimetric evaluation of flattening filter-free volumetric modulated arc therapy for postoperative treatment of cervical cancer 被引量:1
6
作者 Fuli Zhang Huayong Jiang +10 位作者 Weidong Xu Yadi Wang Junmao Gao Qingzhi Liu Ping Wang Na Lu Diandian Chen Bo Yao Jun Hou Heliang He Jianping Chen 《Oncology and Translational Medicine》 2016年第4期179-184,共6页
Objective The aim of the study was to compare flattening filter-free(FFF) beams and conventional flattening filter(FF) beams in volumetric modulated arc therapy(VMAT) for cervical cancer after surgery, through a retro... Objective The aim of the study was to compare flattening filter-free(FFF) beams and conventional flattening filter(FF) beams in volumetric modulated arc therapy(VMAT) for cervical cancer after surgery, through a retrospective planning study.Methods VMAT plans of FFF beams and normal FF beams were designed for a cohort of 15 patients. The prescribed dose was 45 Gy to 1.8 Gy per fraction, and at least 95% of the planning target volume received this dose. Doses were computed with a commercially available treatment planning system using a Monte Carlo(MC) algorithm. Plans were compared according to dose-volume histogram analysis in terms of planning target volume homogeneity and conformity indices(HI and CI), as well as organs at risk(OAR) dose and volume parameters. Results FFF-VMAT was similar to FF-VMAT in terms of CI, but inferior to FF-VMAT considering HI. No statistically differences were observed between FFF-VMAT and FF-VMAT in following organ at risks including pelvic bone marrow, small bowel, bladder, rectum, and normal tissue(NT)..Conclusion For patients with cervical cancer after hysterectomy, the FFF beam achieved target and OAR dose distribution similar to that of the FF beam. Reduction of beam-on time in cervical cancer is beneficial. 展开更多
关键词 flattening filter-free(FFF) cervical cancer dosimetry volumetric modulated arc therapy(VMAT)
下载PDF
DICOM-RT Plan Complexity Verification for Volumetric Modulated Arc Therapy
7
作者 Hideharu Miura Masao Tanooka +7 位作者 Hiroyuki Inoue Masayuki Fujiwara Kengo Kosaka Hiroshi Doi Yasuhiro Takada Soichi Odawara Norihiko Kamikonya Shozo Hirota 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2014年第3期117-124,共8页
The purpose of this study was to investigate the relationship between plan parameters verified with DICOM-RT and dosimetric results for volumetric modulated arc therapy (VMAT). We investigated three treatment location... The purpose of this study was to investigate the relationship between plan parameters verified with DICOM-RT and dosimetric results for volumetric modulated arc therapy (VMAT). We investigated three treatment locations: prostate cancer (ten cases), maxillary sinus cancer (four cases), and malignant pleura mesothelioma (four cases) with treatment plans generated by a MonacoTM treatment planning system (TPS), and delivered with an Elekta SynergyTM linear accelerator. We calculated plan parameters, including gantry and multileaf collimator (MLC) positions, Monitor Units (MU), and millimeters of MLC motion per degree of gantry rotation (mm/degree), and performed quality assurance (QA) with a DICOM-RT plan verification system. We measured the VMAT dose with a two-dimensional diode array detector. The average gamma passing rate with percent dose acceptance criteria and distance to agreement criteria of 2 mm and 2% (2 mm/2%) were 97.4%, 97.8% and 92.0% for prostate cancer, maxillary sinus cancer, and malignant pleural mesothelioma, respectively. The mean 95th percentile value for DICOM-calculated mm/degree was 4.0, 5.2, and 11.1 for prostate cancer, maxillary sinus cancer, and malignant pleural mesothelioma, respectively. The gamma passing rate showed a correlation with calculated mm/degree, with a coefficient of determination (R2) of 0.60. Higher calculated mm/degree values led to increased dosimetric errors. We conclude that dose distribution calculated by a TPS is more reliable at smaller mm/degree. 展开更多
关键词 volumetric modulated arc Therapy Quality ASSURANCE RADIATION Treatment Planning RADIATION DOSIMETRY
下载PDF
Dosimetric comparison of different multileaf collimators in volumetric modulated arc therapy for malignant pleural mesothelioma
8
作者 Fuli Zhang Huayong Jiang +8 位作者 Weidong Xu Yadi Wang Junmao Gao Qingzhi Liu Na Lu Diandian Chen Bo Yao Jun Hou Jianping Chen 《Oncology and Translational Medicine》 CAS 2015年第4期186-189,共4页
Objective The aiom of the study was to compare the impacts of two types of multileaf collimators (MLC) [standard MLC with a width of 10 mm (sMLC) and micro-MLC with a width of 5 mm (mMLC)] on volumetric modulate... Objective The aiom of the study was to compare the impacts of two types of multileaf collimators (MLC) [standard MLC with a width of 10 mm (sMLC) and micro-MLC with a width of 5 mm (mMLC)] on volumetric modulated arc therapy (VMAT) planning for malignant pleural mesothelioma. Methods VMAT for ten patients with inoperable malignant pleural mesotheliomas was retrospectively planned with the sMLC and mMLC. Histogram-based dose-volume parameters of the planning target vol- ume (PTV) [conformity index (CI) and homogeneous index (HI)] and organs-at-risk were compared for VMAT plans with sMLC (sMLC-VMAT) and mMLC (mMLC-VMAT). Results The mMLC-VMAT plans were more efficient (average delivery time: 2.67±1.49 min) than the sMLC-VMAT plans (average delivery time: 4.21 ± 2.03 min; P 〈 0.05). Moreover, compared to the sMLC plans, the mMLC plans demonstrated advantages in the dose coverage of the PTV (CI 0.75 ± 0.08 vs 0.73± 0.09; HI 1.09 ±0.02 vs 1.10± 0.02), although the difference was not statistically significant (P 〉 0.05). In addition, significant dose sparing in the fraction of the ipsilateral lung volume receiving 〉 20 Gy (V20; 54.72± 27.08 vs 58.52 ± 29.30) and 〉 30 Gy (V30; 42.74 ± 27.86 vs 46.86± 31.49) radiation, respectively, was observed for the mMLC plans (P 〈 0.05). Conclusion Comparing sMLC-VMAT and mMLC-VMAT not only demonstrated the higher efficiency and better optimal target coverage of mMLC-VMAT, but also considerably improved the dose sparing of the ipsilateral lung in the VMAT plans for mali qnant pleural mesothelioma. 展开更多
关键词 multileaf collimator (MLC) MESOTHELIOMA volumetric modulated arc therapy (VMAT)
下载PDF
Benefits and Limitations of Volumetric Modulated Arc Therapy in Treating Bilateral Breast Cancer with Regional Lymph Nodes
9
作者 R. P. Srivastava K. Vandeputte C. De Wagter 《Advances in Breast Cancer Research》 2020年第4期119-126,共8页
<strong>Purpose:</strong><span style="font-family:""><span style="font-family:Verdana;"> The study was performed comparing dosimetric characteristics of volumetric modu... <strong>Purpose:</strong><span style="font-family:""><span style="font-family:Verdana;"> The study was performed comparing dosimetric characteristics of volumetric modulated arc therapy (VMAT) and field-in-field (FiF) techniques on a patient with synchronous bilateral breast carcinoma. </span><b><span style="font-family:Verdana;">Methods:</span></b><span style="font-family:Verdana;"> The patients with bilateral breast cancer treatment were included in this study. A total dose of 40.05 Gy in 15 fractions was prescribed to the Planning Target Volume (PTV) of the whole bilateral breast cancer with the supraclavicular and infraclavicular nodes, with a complementary boost of 10 Gy in 4 fractions to the surgical bed (PTV</span><sub><span style="font-family:Verdana;">boost</span></sub><span style="font-family:Verdana;">). For both radiotherapy techniques, several V</span><sub><span style="font-family:Verdana;">xGy</span></sub><span style="font-family:Verdana;"> parameters were analyzed for the PTVs, together with the Conformity index (CI), the Homogeneity index (HI) and the critical organs at risk (OARs), lungs and heart. </span><b><span style="font-family:Verdana;">Results:</span></b><span style="font-family:Verdana;"> The patient was treated by the VMAT technique and the daily treatment time was less than 20 minutes with daily CBCT imaging. In the VMAT plan, the PTV 95% dose covered 38.89 ± 0.81 Gy, compared to 37.26 ± 1.02 Gy in the FiF technique. The VMAT plan improved the dose homogeneity index and lower dose in lung towards high dose region. </span><b><span style="font-family:Verdana;">Conclusion:</span></b><span style="font-family:Verdana;"> The study demonstrates the viability of the VMAT technique in the treatment of bilateral breast cancer. The introduced single isocentric VMAT technique is fast to deliver and it increases the dose homogeneity of the target volume with some limitations. The treatment was well tolerated, without interruption of the treatment courses caused by treatment</span></span><span style="font-family:Verdana;">-</span><span style="font-family:Verdana;">related toxicities.</span> 展开更多
关键词 Bilateral Breast Cancer (BCC) volumetric modulated arc Therapy (VMAT) Field in Field (FiF) Planning Target Volume (PTV) Organ’s Volume That Receives x Gy of Dose (VxGy)
下载PDF
Predicting Delivery Error Using a DICOM-RT Plan for Volumetric Modulated Arc Therapy
10
作者 Hideharu Miura Masao Tanooka +6 位作者 Masayuki Fujiwara Yasuhiro Takada Hiroshi Doi Soichi Odawara Kengo Kosaka Norihiko Kamikonya Shozo Hirota 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2014年第2期82-87,共6页
The purpose of this study was to investigate the prediction of mechanical error using DICOM-RT plan parameters for volumetric modulated arc therapy (VMAT). We created plans for gantry rotation arcs of 360° and 18... The purpose of this study was to investigate the prediction of mechanical error using DICOM-RT plan parameters for volumetric modulated arc therapy (VMAT). We created plans for gantry rotation arcs of 360° and 180° (full-arc and half-arc VMAT) for six maxillary sinus cancer cases using a Monaco treatment planning system, and delivered the doses with a linear accelerator. We calculated DICOM-RT plan parameters, including gantry, multileaf collimator (MLC) positions and Monitor Units (MU). We compared plans with regard to gantry angle per MU (degrees/MU) and MLC travel per MU (mm/MU) for each segment. Calculated gantry angle/MLC position speeds and errors were evaluated by comparison with the log file. On average, the half-arc VMAT plan resulted in 47% and 35% fewer degrees/MU and mm/MU than the full-arc VMAT plan, respectively. The root mean square (r.m.s.) gantry and MLC speeds showed a linear relationship with calculated degrees/MU and mm/MU, with coefficients of determination (R2) of 0.86 and 0.72, respectively. The r.m.s. gantry angle and MLC position errors showed a linear relationship with calculated degrees/MU and mm/MU with R2 of 0.63 and 0.76, respectively. Deviations from plan parameters were related to mechanical error for VMAT, and provided quantitative information without the need for VMAT delivery. These parameters can be used in the selection of treatment planning. 展开更多
关键词 volumetric-modulated arc Therapy DICOM-RT PLAN PATIENT-SPECIFIC QA RADIOTHERAPY Planning COMPUTER-ASSISTED
下载PDF
Volumetric modulated arc radiotherapy for limited osteosclerotic myeloma
11
作者 Aurélie Robles Antonin Levy +9 位作者 Coralie Moncharmont Lamine Farid Jean-Baptiste Guy Nadia Malkoun Lysian Cartier Cyrus Chargari Isabelle Guichard Jean-Noёl Talabard Guy de Laroche Nicolas Magné 《World Journal of Radiology》 CAS 2013年第4期173-177,共5页
AIM:To assess the feasibility of volumetric intensity-modulated arc radiotherapy (VMAT) in patients with limited polyneuropathy, organomegaly, endocrinopathy, monoclonal gammopathy, and skin changes syndrome. METHODS:... AIM:To assess the feasibility of volumetric intensity-modulated arc radiotherapy (VMAT) in patients with limited polyneuropathy, organomegaly, endocrinopathy, monoclonal gammopathy, and skin changes syndrome. METHODS:A 70-year-old male with histologically confirmed osteosclerotic myeloma was treated in our department in July 2010 with VMAT. Fourty-six Gray in 23 fractions were given on three bone lesions. Doses delivered to target volume and critical organs were compared with a tridimensional conformal radiotherapy (3D-RT) plan. Treatment was well tolerated without any side effects.RESULTS:VMAT improved dose homogeneity within the target volume, as compared to 3D-RT (standard deviations:2.9 Gy and 1.6 Gy for 3D and VMAT, respectively). VMAT resulted in a better sparing of critical organs. Dose delivered to 20% of organ volume (D20) was reduced from 22 Gy (3D-RT) to 15 Gy (VMAT) for small bowel, from 24 Gy (3D-RT) to 17 Gy (VMAT) for bladder and from 47 Gy (3D-RT) to 3 Gy (VMAT) for spinal cord. Volumes of critical organs that received at least 20 Gy (V20) were decreased by the use of VMAT, as compared to 3D-RT (V20 bladder:10% vs 99%; V20 small bowel:6% vs 21%). One year after treatment completion, no tumor progression has been reported. CONCLUSION:VMAT improved dose distribution as compared to 3D-RT for limited osteosclerotic myeloma, with better saving of critical organs. 展开更多
关键词 volumetric intensity-modulated arc RADIOTHERAPY Conformal RADIOTHERAPY Critical organs Osteosclerotic MYELOMA Polyneuropathy organomegaly ENDOCRINOPATHY monoclonal GAMMOPATHY and skin change syndrome
下载PDF
Dosimetric Comparative Analysis of Volumetric Modulated Arc Therapy and Intensity-Modulated Radiation Therapy in Cervical Cancer
12
作者 Ruixin He 《Proceedings of Anticancer Research》 2023年第3期13-17,共5页
Objective:To carry out dosimetric comparison between volumetric modulated arc therapy(VMAT)and intensity-modulated radiation therapy(IMRT)in cervical cancer.Methods:50 postoperative cervical cancer patients were inclu... Objective:To carry out dosimetric comparison between volumetric modulated arc therapy(VMAT)and intensity-modulated radiation therapy(IMRT)in cervical cancer.Methods:50 postoperative cervical cancer patients were included in this study.The patients were admitted for treatment from January 2021 to January 2022.VMAT and IMRT plans were designed for each patient to analyze the dose distribution in the target area of the two treatment techniques.Results:Comparing the monitor unit for single treatment(638.21±116.21 MU)and time of single treatment(143.21±23.14 s)in the observation group and the monitor unit for single treatment(932.14±74.11 MU)and time of single treatment(223.14±17.26 s)in the control group,there was significant difference(P<0.05);there was also significant difference(P<0.05)between the normal tissue(bladder and rectum)of the observation group and that(bladder and rectum)of the control group.Conclusion:VMAT is more effective in cervical cancer,and it has a certain protective effect on normal tissues in patients and can reduce the radiation dose. 展开更多
关键词 volumetric modulated arc therapy Intensity-modulated radiation therapy Radiotherapy for cervical cancer DOSE
下载PDF
Volumetric modulation arc radiotherapy with flattening filter-free beams compared with conventional beams for nasopharyngeal carcinoma:a feasibility study 被引量:3
13
作者 Mingzan Zhuang Tuodan Zhang +5 位作者 Zhijian Chen Zhixiong Lin Derui Li Xun Peng Qingchun Qiu Renhua Wu 《Chinese Journal of Cancer》 SCIE CAS CSCD 2013年第7期397-402,共6页
There is increasing interest in the clinical use of flattening filter-free(FFF) beams.In this study,we aimed to investigate the dosimetric characteristics of volumetric modulated arc radiotherapy(VMAT) with FFF beams ... There is increasing interest in the clinical use of flattening filter-free(FFF) beams.In this study,we aimed to investigate the dosimetric characteristics of volumetric modulated arc radiotherapy(VMAT) with FFF beams for nasopharyngeal carcinoma(NPC).Ten NPC patients were randomly selected to undergo a RapidArc plan with either FFF beams(RA-FFF) or conventional beams(RA-C).The doses to the planning target volumes(PTVs),organs at risk(OARs),and normal tissues were compared.The technical delivery parameters for RapidArc plans were also assessed to compare the characteristics of FFF and conventional beams.Both techniques delivered adequate doses to PTVs.For PTVs,RA-C delivered lower maximum and mean doses and improved conformity and homogeneity compared with RA-FFF.Both techniques provided similar maximum doses to the optic nerves and lenses.For the brain stem,spinal cord,larynx,parotid glands,oral cavity,and skin,RA-FFF showed significant dose increases compared to RA-C.The dose to normal tissue was lower in RA-FFF.The monitor units(MUs) were(536 ± 46) MU for RA-FFF and(501± 25) MU for RA-C.The treatment duration did not significantly differbetween plans.Although both treatment plans could meet clinical needs,RA-C is dosimetrically superior to RA-FFF for NPC radiotherapy. 展开更多
关键词 无滤波器 鼻咽癌 无梁 放疗 剂量学特性 传统 平坦 调制
下载PDF
ArcCHECK Machine QA工具在医用直线加速器质量保证中的应用效果
14
作者 张上超 曾华驱 王思阳 《医疗装备》 2024年第7期19-24,共6页
目的探讨ArcCHECK Machine QA工具在医用直线加速器质量保证中的应用效果。方法利用ArcCHECK Machine QA工具和ArcCHECK体模对医用直线加速器进行性能测试,项目包括机架角度、机架旋转速度、机架旋转中心、多叶准直器和铅门位置的一致... 目的探讨ArcCHECK Machine QA工具在医用直线加速器质量保证中的应用效果。方法利用ArcCHECK Machine QA工具和ArcCHECK体模对医用直线加速器进行性能测试,项目包括机架角度、机架旋转速度、机架旋转中心、多叶准直器和铅门位置的一致性、机架旋转出束时的平坦度和对称性,评估该工具在医用直线加速器质量保证中的应用效果。结果旋转模式下机架平均旋转速度为3.6 deg/s,最大偏差约0.5 deg/s;机架旋转等中心形成的平均半径为0.4 mm,多叶准直器与铅门的最大距离正、负差异平均值分别为0.7 mm、-0.7 mm;旋转出束模式下Y方向的平坦度为1.8%,Y方向的对称性为1.1%,X方向的对称性为4.3%。结论ArcCHECK Machine QA工具可用于医用直线加速器常规及容积调强出束性能质量保证。 展开更多
关键词 arcCHECK Machine QA工具 质量保证 容积调强 等中心
下载PDF
A Systematic Approach to Patient-Specific Quality Assurance for Volumetric Modulated Arc Therapy
15
作者 SONG Yu-lin Ceferino Obcemea +1 位作者 Boris Mueller Borys Mychalczak 《Chinese Journal of Biomedical Engineering(English Edition)》 CSCD 2015年第2期58-65,共8页
We developed the first non-commercial treatment planning system for volumetric modulated arc therapy(VMAT) in the United States. Because VMAT involves multi-parameter modulations, it is imperative to develop a compreh... We developed the first non-commercial treatment planning system for volumetric modulated arc therapy(VMAT) in the United States. Because VMAT involves multi-parameter modulations, it is imperative to develop a comprehensive, rigorous and yet, practical procedure for routine patient-specific quality assurance(QA). In this paper, we presented our own approach as being currently implemented in our institution.Our patient-specific QA procedure involves multi-levels: pre-treatment QA,on-treatment QA, and posttreatment QA. The pre-treatment QA focuses on dosimetry verification, which is done with the commercial Map CHECK in Map PHAN mounted on an isocentric mounting fixture(IMF). This method is also referred to the fixed-gantry technique,i.e., the beams always remain perpendicular to the detector plane. The on-treatment QA involves in vivo optically stimulated luminescent dosimetry(OSLD).Prior to the treatment, two nano Dot TM OSLD dosimeters are placed on the patient abdomen under 1 cm bolus at the isocenter location. The irradiated dosimeters are then read by a nano Dot TM reader and the average reading of the two is calculated. The post-treatment QA involves the analysis of the Dyna Log and DLog files. The Dyna Log is a treatment log file that contains the planned and actual leaf positions at a given gantry angle. The DLog is a treatment log file that contains the planned segmented treatment table(STT) and the corresponding segment boundary samples, i.e., the actual delivered MU and gantry angle increment at each control point. 展开更多
关键词 volumetric modulated arc therapy(VMAT) quality assurance intensity modulated radiation therapy(IMRT) rapid arc
原文传递
ArcCheck模体与胶片在鼻咽癌VMAT剂量验证中的比较研究 被引量:7
16
作者 易金玲 金献测 +5 位作者 周永强 韩策 郑晓敏 吴志勤 黄珂靖 谢聪颖 《中国医疗器械杂志》 CAS 2013年第3期228-231,共4页
比较研究ArcCheck与胶片在鼻咽癌容积弧形调强(VMAT)验证中的应用,探讨ArcCheck在VMAT剂量验证中的可行性。随机选取5例鼻咽癌病人的VMAT治疗计划,分别用ArcCheck和胶片两种方法进行剂量验证,比较两种方法的验证结果。ArcCheck验证的平... 比较研究ArcCheck与胶片在鼻咽癌容积弧形调强(VMAT)验证中的应用,探讨ArcCheck在VMAT剂量验证中的可行性。随机选取5例鼻咽癌病人的VMAT治疗计划,分别用ArcCheck和胶片两种方法进行剂量验证,比较两种方法的验证结果。ArcCheck验证的平均通过率为96.74±2.60,胶片验证的平均通过率是95.95±1.17,利用统计分析t检验,结果表明ArcCheck和胶片验证两种结果在剂量学上没有明显差异。ArcCheck分析软件可以直接获取三维合成的剂量分布,且操作过程较胶片验证简单,可以更为便捷的进行VMAT剂量验证。 展开更多
关键词 鼻咽癌 VAMT计划 arcCheck验证 胶片验证
下载PDF
ArcCheck系统在鼻咽癌容积旋转调强剂量验证中的应用 被引量:13
17
作者 张俊俊 邱小平 +6 位作者 李奇欣 柏朋刚 张秀春 蔡勇君 陈开强 李江山 程燕铭 《中国医学物理学杂志》 CSCD 2014年第5期5136-5138,5168,共4页
目的:研究ArcCheck验证系统在鼻咽癌容积旋转调强剂量验证中的应用。在病人接受放射治疗之前,进行容积调强计划的验证,使其满足计划设计要求。保证患者实际照射中接受到准确的剂量,确保治疗的安全。方法:选择34例鼻咽癌病例用热塑型体... 目的:研究ArcCheck验证系统在鼻咽癌容积旋转调强剂量验证中的应用。在病人接受放射治疗之前,进行容积调强计划的验证,使其满足计划设计要求。保证患者实际照射中接受到准确的剂量,确保治疗的安全。方法:选择34例鼻咽癌病例用热塑型体部网罩固定,CT扫描定位,将计划CT传到Pinnacle计划系统(9.2版本)中进行容积旋转调强治疗计划设计,然后将设计好的计划传输至MOSAIQ网络系统上。同时把治疗计划导入ArcCheck模体中重新新型剂量计算。在验证之前,对Arccheck系统进行本底校准,矩阵校准,绝对剂量校准。分析方法采用的是Gamma方法在ArcCHECK自带软件中对治疗计划系统中计算的结果和实际测量的结果二者的差异,阈值标准选择3%,3mm,10%。采用微软Excel2003数据统计软件。结果:Gamma分析方法相对量通过率97.9%,绝对量通过率为95.9%;实测剂量分布图与理论计算剂量分布图在高低剂量点分布上重合很好;另外X方向和Y方向的平坦度,实测结果与计算结果很接近。结论:ArcCheck验证系统在鼻咽癌容积旋转剂量验证中是可行的。它是一种方便快捷准确的旋转调强剂量验证方法。 展开更多
关键词 arcCheck系统 容积旋转调强 鼻咽癌 Gamma方法
下载PDF
非晶硅电子射野影像系统与ArcCHECK在直肠癌容积旋转调强剂量验证中的应用 被引量:9
18
作者 黎旦 宾石珍 +3 位作者 程品晶 单冬勇 成树林 张俊俊 《中国医学物理学杂志》 CSCD 2016年第7期674-677,共4页
目的:比较非晶硅电子射野影像系统(a-Si EPID)与旋转照射剂量验证仪器(Arc CHECK)在直肠癌容积旋转调强(VMAT)剂量验证中的应用。方法:随机选取20例直肠癌VMAT病例,分别设计a-Si EPID与Arc CHECK的验证计划,并在UNIQUE加速器上进行验证... 目的:比较非晶硅电子射野影像系统(a-Si EPID)与旋转照射剂量验证仪器(Arc CHECK)在直肠癌容积旋转调强(VMAT)剂量验证中的应用。方法:随机选取20例直肠癌VMAT病例,分别设计a-Si EPID与Arc CHECK的验证计划,并在UNIQUE加速器上进行验证。采用γ分析方法(3 mm,3%)比较两种不同验证工具的相对剂量与绝对剂量通过率、X和Y方向的profile。结果:Arc CHECK的绝对剂量通过率为(97.73±1.98)%,相对剂量通过率为(96.96±2.34)%;aSi EPID的绝对剂量通过率为(97.58±1.88)%,相对剂量通过率为(98.13±1.47)%。X、Y方向的profile理论值与实测值很相近,理论剂量分布图与实测计算剂量分布图在高低剂量点分布上重合度较高。结论:Arc CHECK和a-Si EPID的验证结果在剂量学上没有明显差异,两者在直肠癌VMAT剂量验证中都是可行的,但a-Si EPID操作简单、使用方便、显示剂量即时,可以更便捷地进行VMAT剂量验证。 展开更多
关键词 直肠癌 非晶硅电子射野影像系统 arc CHECK 容积旋转调强 剂量验证
下载PDF
晚期鼻咽癌RapidArc与固定野调强放疗的比较研究 被引量:4
19
作者 庄名赞 张拓丹 +3 位作者 彭逊 陈志坚 林志雄 李德锐 《中国肿瘤临床》 CAS CSCD 北大核心 2013年第3期140-143,共4页
目的:近年RapidArc的临床应用已引起越来越多的关注,本研究比较RapidArc与固定野调强放射治疗(IMRT)两种放疗技术在晚期鼻咽癌治疗计划中的差异。方法:随机选取10例晚期鼻咽癌患者,采用RapidArc与IMRT两种技术进行计划设计与剂量验证,... 目的:近年RapidArc的临床应用已引起越来越多的关注,本研究比较RapidArc与固定野调强放射治疗(IMRT)两种放疗技术在晚期鼻咽癌治疗计划中的差异。方法:随机选取10例晚期鼻咽癌患者,采用RapidArc与IMRT两种技术进行计划设计与剂量验证,比较计划的靶区剂量、危及器官与正常组织剂量、机器跳数、治疗时间与剂量验证结果。结果:两种计划的剂量分布基本一致,均能提供足够的靶区剂量。RapidArc的PTVnx最小剂量,PTVnd、PTV60、喉、腮腺的平均剂量低于IMRT,PTV60的HI值高于IMRT,机器跳数比IMRT减少约58%,治疗时间减少约70%。以3%/3mm为界,RapidArc验证的γ指数通过率为(98.75±0.50)%,IMRT的通过率为(98.86±0.67)%。结论:两种放疗技术均能够满足临床治疗需要,剂量验证结果能够较好的符合计划计算结果。RapidArc比IMRT有着更多的优势,不仅可以减少机器跳数,缩短治疗时间,而且可以减少喉、腮腺的受照剂量。 展开更多
关键词 鼻咽癌 RAPIDarc 固定野调强放射治疗 旋转调强放射治疗
下载PDF
运用ArcCHECK实施旋转调强全骨髓照射超长靶区的计划验证 被引量:7
20
作者 解传滨 徐寿平 +5 位作者 徐伟 丛小虎 葛瑞刚 巩汉顺 鞠忠建 戴相昆 《中国医疗器械杂志》 CAS 2015年第1期68-71,共4页
探讨利用Arc CHECK对VMAT(Volumetric Modulated Arc Therapy)和HT(Helical Tomotherapy)全骨髓照射(TMI)超长靶区计划的验证方法。选取8例全身扫描患者,分别设计TMI计划。采用Arc CHECK对两组计划头颈、胸腹及盆腔三部位行验证分析。V... 探讨利用Arc CHECK对VMAT(Volumetric Modulated Arc Therapy)和HT(Helical Tomotherapy)全骨髓照射(TMI)超长靶区计划的验证方法。选取8例全身扫描患者,分别设计TMI计划。采用Arc CHECK对两组计划头颈、胸腹及盆腔三部位行验证分析。VMAT组采用模体Merge功能通过平移治疗床实现,HT组采用双计划(参考/执行)法得以完成,三部位验证通过率分别为98.9%±1.9%/94.3%±1.5%、98.4%±1.8%/96.5%±1.2%、97.4%±2.1%/94.1%±1.9%。表明利用Arc CHECK的Merge功能能较好地完成VMAT超长靶区的验证,采用双计划法实现了对HT超长靶区及远离中心部分靶区的验证。 展开更多
关键词 剂量验证 全骨髓照射(TMI) 容积旋转调强放射治疗(VMAT) 螺旋断层放射治疗(HT)