To reduce the walk-off angle of the extraordinary third-harmonic ultraviolet wave at 355 nm generated by type ⅡKTiOPO4 and type I β-BaB2O4 optical crystals,and the Gaussian output beam of a Q-switched Nd:YAG laser,...To reduce the walk-off angle of the extraordinary third-harmonic ultraviolet wave at 355 nm generated by type ⅡKTiOPO4 and type I β-BaB2O4 optical crystals,and the Gaussian output beam of a Q-switched Nd:YAG laser,a simple theoretical model was developed based on a rotatable BK7 plate of variable thickness.By rotating the plate up to 35°along the beam direction,we reduced the walk-off angle up to ~ 13%.The same phenomenon is predicted by the model,confirming the performance of the model.It is found that,due to the walk-off effect,the intensity profile of the thirdharmonic generation beam is slightly degraded.To compensate for the observed phenomena and further reduce the walkoff,we used a combination of a convex lens and an axicon to transform the beam profile of the interacting fundamental and second-harmonic generation waves to the zero-order Bessel-Gaussian form.As a result,the walk-off is decreased to~ 48.81 mrad,providing ~ 30%relative reduction.By using the same BK7 plate rotated up to 35° along the third-harmonic beam direction,the walk-off angle is further reduced to 38.9 mrad.Moreover,it is observed that the beam profile of the emerged Bessel-Gaussian third-harmonic generation beam remains unchanged with no degradation.展开更多
文摘To reduce the walk-off angle of the extraordinary third-harmonic ultraviolet wave at 355 nm generated by type ⅡKTiOPO4 and type I β-BaB2O4 optical crystals,and the Gaussian output beam of a Q-switched Nd:YAG laser,a simple theoretical model was developed based on a rotatable BK7 plate of variable thickness.By rotating the plate up to 35°along the beam direction,we reduced the walk-off angle up to ~ 13%.The same phenomenon is predicted by the model,confirming the performance of the model.It is found that,due to the walk-off effect,the intensity profile of the thirdharmonic generation beam is slightly degraded.To compensate for the observed phenomena and further reduce the walkoff,we used a combination of a convex lens and an axicon to transform the beam profile of the interacting fundamental and second-harmonic generation waves to the zero-order Bessel-Gaussian form.As a result,the walk-off is decreased to~ 48.81 mrad,providing ~ 30%relative reduction.By using the same BK7 plate rotated up to 35° along the third-harmonic beam direction,the walk-off angle is further reduced to 38.9 mrad.Moreover,it is observed that the beam profile of the emerged Bessel-Gaussian third-harmonic generation beam remains unchanged with no degradation.