Sodium hypochlorite has significant potential as a sanitation solution in hard-to-reach areas.Few studies have investigated the optimal electrolysis parameters for its production with volumes greater than 1o L.This st...Sodium hypochlorite has significant potential as a sanitation solution in hard-to-reach areas.Few studies have investigated the optimal electrolysis parameters for its production with volumes greater than 1o L.This study evaluated sodium hypochlorite production through electrolysis in a 22-L prototype and identified the optimal operating parameters.Tests were performed using graphite electrodes with areas of 68.4 cm^(2) at the laboratory scale and 1865.0 cm^(2) at the prototype scale.A design for experiments with different operating times,chloride concentrations,and electric current intensities was developed.The optimal operating time,sodium chloride concentration,and current intensity at the laboratory scale were 120 min,150 g of chloride per liter,and 3 A,respectively,leading to the production of 5.02 g/L of the disinfectant with an energy efficiency of 12.21 mg of Cl_(2) per kilojoule.At the prototype scale,the maximum sodium hypochlorite concentration of 3.99 g of chloride per liter was achieved with an operating time of 120 min,a sodium chloride concentration of 100 g of chloride per liter,and a current intensity of 70 A,reaching an energy efficiency of 42.56 mg of Cl_(2) per kilojoule.In addition,this study evaluated the influences of the chloride concentration,current intensity,and operating time on the production of sodium hypochlorite at the two scales,and formulated the equations showing the trends of sodium hypochlorite production and energy efficiency in the electrochemical systems.The 22-L prototype model for production of this oxidizing substance is promising for disinfection of large volumes of water in areas that are difficult to access.展开更多
Objective To study the effectiveness and feasibility of cryogenic disinfectants in different cold scenarios and analyze the key points of on-site cryogenic disinfection.Methods Qingdao and Suifenhe were selected as ap...Objective To study the effectiveness and feasibility of cryogenic disinfectants in different cold scenarios and analyze the key points of on-site cryogenic disinfection.Methods Qingdao and Suifenhe were selected as application sites for the manual or mechanical spraying of cryogenic disinfectants.The same amount of disinfectant(3,000 mg/L)was applied on cold chain food packaging,cold chain containers,transport vehicles,alpine environments,and article surfaces.The killing log value of the cryogenic disinfectant against the indicator microorganisms(Staphylococcus aureus and Escherichia coli)was used to evaluate the on-site disinfection effect.Results When using 3,000 mg/L with an action time of 10 min on the ground in alpine regions,the surface of frozen items,cold-chain containers,and cold chain food packaging in supermarkets,all external surfaces were successfully disinfected,with a pass rate of 100%.The disinfection pass rates for cold chain food packaging and cold chain transport vehicles of centralized supervised warehouses and food processing enterprises were 12.5%(15/120),81.67%(49/60),and 93.33%(14/15),respectively;yet,the surfaces were not fully sprayed.Conclusion Cryogenic disinfectants are effective in disinfecting alpine environments and the outer packaging of frozen items.The application of cryogenic disinfectants should be regulated to ensure that they cover all surfaces of the disinfected object,thus ensuring effective cryogenic disinfection.展开更多
To investigate the corrosion behaviors and antibacterial effects of sodium hypochlorite(NaClO)and hydrogen peroxide silver ion(HPSI)disinfectants with different concentrations against dental unit waterlines and provid...To investigate the corrosion behaviors and antibacterial effects of sodium hypochlorite(NaClO)and hydrogen peroxide silver ion(HPSI)disinfectants with different concentrations against dental unit waterlines and provide guidance and reference for the use of chemical disinfectants,polyurethane tubes were immersed in ultrapure water(control group),0.1%NaClO,0.5%NaClO,1.0%NaClO,2.5%HPSI,5.0%HPSI,and 10%HPSI solutions for 6,12,and 18 weeks.Contact angles and Fourier transform infrared spectra were detected.Surface morphologies were observed using scanning electron microscopy and antibacterial activity was evaluated using Gram-positive Staphylococcus aureus(S.aureus).The results showed that sodium hypochlorite and hydrogen peroxide silver ion disinfectants presented good antibacterial activity against S.aureus.However,sodium hypochlorite could cause serious damage to the water pipes where corrosion pits and cracks were observed,and increasing the concentration of sodium hypochlorite could accelerate the corrosion process.Hydrogen peroxide silver ion disinfectants had no obvious damage to the water pipes.Therefore,hydrogen peroxide silver ion disinfectants are recommended to use for controlling bacterial infection in dental unit waterlines which can reduce the damage to the water pipes.展开更多
Tracing the contamination origins in water sources and identifying the impacts of natural and human processes are essential for ecological safety and public health.However,current analysis approaches are not ideal,as ...Tracing the contamination origins in water sources and identifying the impacts of natural and human processes are essential for ecological safety and public health.However,current analysis approaches are not ideal,as they tend to be laborious,time-consuming,or technically difficult.Disinfection byproducts(DBPs)are a family of well-known secondary pollutants formed by the reactions of chemical disinfectants with DBP precursors during water disinfection treatment.Since DBP precursors have various origins(e.g.,natural,domestic,industrial,and agricultural sources),and since the formation of DBPs from different precursors in the presence of specific disinfectants is distinctive,we argue that DBPs and DBP precursors can serve as alternative indicators to assess the contamination in water sources and identify pollution origins.After providing a retrospective of the origins of DBPs and DBP precursors,as well as the specific formation patterns of DBPs from different precursors,this article presents an overview of the impacts of various natural and anthropogenic factors on DBPs and DBP precursors in drinking water sources.In practice,the DBPs(i.e.,their concentration and speciation)originally present in source water and the DBP precursors determined using DBP formation potential tests—in which water samples are dosed with a stoichiometric excess of specific disinfectants in order to maximize DBP formation under certain reaction conditions—can be considered as alternative metrics.When jointly used with other water quality parameters(e.g.,dissolved organic carbon,dissolved organic nitrogen,fluorescence,and molecular weight distribution)and specific contaminants of emerging concern(e.g.,certain pharmaceuticals and personal care products),DBPs and DBP precursors in drinking water sources can provide a more comprehensive picture of water pollution for better managing water resources and ensuring human health.展开更多
BACKGROUND Aerosols containing disease-causing microorganisms are produced during oral diagnosis and treatment can cause secondary contamination.AIM To investigate the use of graphene material for air disinfection in ...BACKGROUND Aerosols containing disease-causing microorganisms are produced during oral diagnosis and treatment can cause secondary contamination.AIM To investigate the use of graphene material for air disinfection in dental clinics by leveraging its adsorption and antibacterial properties.METHODS Patients who received ultrasonic cleaning at our hospital from April 2023 to April 2024.They were randomly assigned to three groups(n=20 each):Graphene nanocomposite material suction group(Group A),ordinary filter suction group(Group B),and no air suction device group(Group C).The air quality and air colony count in the clinic rooms were assessed before,during,and after the procedure.Additionally,bacterial colony counts were obtained from the air outlets of the suction devices and the filter screens in Groups A and B.RESULTS Before ultrasonic cleaning,no significant differences in air quality PM2.5 and colony counts were observed among the three groups.However,significant differences in air quality PM2.5 and colony counts were noted among the three groups during ultrasonic cleaning and after ultrasonic treatment.Additionally,the number of colonies on the exhaust port of the suction device and the surface of the filter were significantly lower in Group A than in Group B(P=0.000 and P=0.000,respectively).CONCLUSION Graphene nanocomposites can effectively sterilize the air in dental clinics by exerting their antimicrobial effects and may be used to reduce secondary pollution.展开更多
This study aimed to examine the effect of different disinfection methods on the callus of Amorphophallus albus in the tissue culture and rapid propagation system.The calluses induced from buds of A.albus were disinfec...This study aimed to examine the effect of different disinfection methods on the callus of Amorphophallus albus in the tissue culture and rapid propagation system.The calluses induced from buds of A.albus were disinfected with benzalkonium bromide,mercury bichloride,sodium hypochlorite,and ethanol,respectively,for different time periods.The growth of calluses was compared between different treatments and observed in detail by dissection.The results showed that the disinfection with 0.1% mercury bichloride for 5 min and 75% ethanol for 5 s had mild effect on the callus,with the lowest browning rates of 16.32% and 15.46% and the lowest vitrification rates of 3.24% and 9.72%,respectively,after 20 d.The disinfection with benzalkonium bromide and sodium hypochlorite had strong effect on the callus cells,with the lowest browning rate of 50.69% and 25.12% and the lowest vitrification rates of 28.47% and 28.43%,respectively.The cytological observation result showed that the calluses disinfected with ethanol and mercury bichloride showcased compact structures,while those disinfected with sodium hypochlorite and benzalkonium bromide exhibited loose structures.To sum up,it is recommended that 75% ethanol or 0.1% mercury bichloride can be used for disinfection in the tissue culture and rapid propagation of A.albus,while the use of benzalkonium bromide and sodium hypochlorite should be avoided as much as possible.展开更多
Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization sup...Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization supply center from January 2021 to January 2023.The work situation before January 31,2022,was classified as the control group;a routine quality control management model was implemented,and the work situation after January 31,2022,was classified as the observation group.The quality of medical device management and department satisfaction between the two groups were compared.Results:The timely recovery and supply rate,classification and cleaning pass rate,disinfection pass rate,packaging pass rate,sterilization pass rate,and department satisfaction score in the observation group were all higher than those of the control group(P<0.05).Conclusion:Implementing a refined quality control management model in the sterilization supply center can improve the quality management level of medical devices and department satisfaction and is worthy of promotion.展开更多
Since the catalytic activity of most nanozymes is still far lower than the corresponding natural enzymes,there is urgent need to discover novel highly efficient enzyme-like materials.In this work,Co_(3)V_(2)O_(8)with ...Since the catalytic activity of most nanozymes is still far lower than the corresponding natural enzymes,there is urgent need to discover novel highly efficient enzyme-like materials.In this work,Co_(3)V_(2)O_(8)with hollow hexagonal prismatic pencil structures were prepared as novel artificial enzyme mimics.They were then decorated by photo-depositing Ag nanoparticles(Ag NPs)on the surface to further improve its catalytic activities.The Ag NPs decorated Co_(3)V_(2)O_(8)(ACVPs)showed both excellent oxidase-and peroxidase-like catalytic activities.They can oxidize the colorless 3,3’,5,5’-tetramethylbenzidine rapidly to induce a blue change.The enhanced enzyme mimetic activities can be attributed to the surface plasma resonance(SPR)effect of Ag NPs as well as the synergistic catalytic effect between Ag NPs and Co_(3)V_(2)O_(8),accelerating electron transfer and promoting the catalytic process.ACVPs were applied in constructing a colorimetric sensor,validating the occurrence of the Fenton reaction,and disinfection,presenting favorable catalytic performance.The enzyme-like catalytic mechanism was studied,indicating the chief role of⋅O_(2)-radicals in the catalytic process.This work not only discovers a novel functional material with double enzyme mimetic activity but also provides a new insight into exploiting artificial enzyme mimics with highly efficient catalytic ability.展开更多
BACKGROUND Pelvic floor dysfunction(PFD)is related to muscle fiber tearing during childbirth,negatively impacting postpartum quality of life of parturient.Appropriate and effective intervention is necessary to promote...BACKGROUND Pelvic floor dysfunction(PFD)is related to muscle fiber tearing during childbirth,negatively impacting postpartum quality of life of parturient.Appropriate and effective intervention is necessary to promote PFD recovery.AIM To analyze the use of hydrogen peroxide and silver ion disinfection for vaginal electrodes in conjunction with comprehensive rehabilitation therapy for postpartum women with PFD.METHODS A total of 59 women with PFD who were admitted to the hospital from May 2019 to July 2022 were divided into two groups:Control group(n=27)received comprehensive rehabilitation therapy and observation group(n=32)received intervention with pelvic floor biostimulation feedback instrument in addition to comprehensive rehabilitation therapy.The vaginal electrodes were disinfected with hydrogen peroxide and silver ion before treatment.Intervention for both groups was started 6 weeks postpartum,and rehabilitation lasted for 3 months.Pelvic floor muscle voltage,pelvic floor muscle strength,vaginal muscle voltage,vaginal muscle tone,pelvic floor function,quality of life,and incidence of postpartum PFD were compared between the two groups.RESULTS Before comprehensive rehabilitation treatment,basic data and pelvic floor function were not significantly different between the two groups.After treatment,the observation group showed significant improvements in the maximum voltage and average voltage of pelvic floor muscles,contraction time of type I and type II fibers,pelvic floor muscle strength,vaginal muscle tone,vaginal muscle voltage,and quality of life(GQOLI-74 reports),compared with the control group.The observation group had lower scores on the pelvic floor distress inventory(PFDI-20)and a lower incidence of postpartum PFD,indicating the effectiveness of the pelvic floor biostimulation feedback instrument in promoting the recovery of maternal pelvic floor function.CONCLUSION The combination of the pelvic floor biostimulation feedback instrument and comprehensive rehabilitation nursing can improve pelvic floor muscle strength,promote the recovery of vaginal muscle tone,and improve pelvic floor function and quality of life.The use of hydrogen peroxide and silver ion disinfectant demonstrated favorable antibacterial efficacy and is worthy of clinical application.展开更多
The UV irradiation is used for removing Antibiotic Resistant Bacteria(ARB)and Antibiotic Resistance Genes(ARG)from wastewater treatment.Bacteriophages are viruses that infect within bacteria,are recognized for bacteri...The UV irradiation is used for removing Antibiotic Resistant Bacteria(ARB)and Antibiotic Resistance Genes(ARG)from wastewater treatment.Bacteriophages are viruses that infect within bacteria,are recognized for bacterial control.The influence of some parameters in quantification and performance influencing of pathogen demobilization could be considered in disinfection of wastewater.The comparison of Polyvalent phage(NE1)versus Coliphage(NE4)in suppressing a bacterium Escherichia coli(NDM-1:b-lactam-resistant)with UV irradiation was observed the efficacy in reduction of cells in the disinfection and parameter process.The results with the effect of UV-C irradiation on NDM-1 infected with 1%of NE4 showed a decrease of cells from 8×10^(6)to 2×10^(5)in 60 min with UV-C dose.The NDM1(E.coli)was infected with 1%of NE4(Polyvalent Phage)under magnetic stirring for 1 h,the cells count was 8×10^(6).After 1 h in UV-C e×posure,the cells number reached 3×10^(5).The NDM1 that was e×posed in 1 h of UV-C irradiation and then was infected with 1%of NE4.Cells counting were done 24 h after this procedure.These cells were e×posed in UV-C and showed a reduction in the number of cells from 1×10^(8)to 4×10^(5)after 60 min.The results indicate that bacteriophages can mitigate bacteria species,and combined the conventional water disinfection technologies that can support the microbial safety control strategies.展开更多
Ensuring the health and safety of drinking water is crucial for both nations and their citizens.Since the 20th century,the disinfection of drinking water,effectively controlling pathogens in water sources,has become o...Ensuring the health and safety of drinking water is crucial for both nations and their citizens.Since the 20th century,the disinfection of drinking water,effectively controlling pathogens in water sources,has become one of the significant advances in public health.However,the disinfectants used in the process,such as chlorine and chlorine dioxide,react with natural organic matter in the water to produce disinfection by-products(DBPs).Most of these DBPs contain chlorine,and if the source water contains bromine or iodine,brominated or iodinated DBPs,collectively referred to as Halogenated disinfection byproducts(X-DBPs),are formed.Numerous studies have found that X-DBPs pose potential risks to human health and the environment,leading to widespread concern.Mass spectrometry has become an important means of discovering new types of X-DBPs.This paper focuses on the study of methods for analyzing X-DBPs in drinking water using mass spectrometry.展开更多
[Objective] This study was conducted to investigate the effects of Penicillium spp. and Trichoderma spp. on the growth of Pleurotus ostreatus (oyster mushroom) and to screen effective disinfectants to control them a...[Objective] This study was conducted to investigate the effects of Penicillium spp. and Trichoderma spp. on the growth of Pleurotus ostreatus (oyster mushroom) and to screen effective disinfectants to control them and other pathogenic microbes. [Method] Six strains or species of Penicilliurn and Trichoderma were inocu- lated into PDA plates growing with P. ostreatus to observe the growth of their mycelia. And the inhibitory effects of hydrogen peroxide, bromogeramine bromide, 84 disinfectant, lysol, potassium permanganate, and 75% medical alcohol on Trichoderma pleuroticola, Trichoderma viride, Trichoderma harzianum, Penicillium citrinum, Penicillium thomii and Penicillium brevicompactum were detected. [Result] Confrontation test revealed that Penicillium spp. and Trichoderma spp. competed for nutrients with P. ostreatus mycelia, antagonized against the growth of P. ostreatus mycelia, invaded and twined around P. ostreatus mycelia, and also produced toxins poisoning P. ostreatus mycelia. The six disinfectants exhibited different inhibitory effects against different species of Penicillium and Trichoderma. Among them the in- hibitory effects of bromogeramine bromide against the six species of Penicillium and Trichoderma were significantly different. However, the inhibitory effects of 3% hydrogen peroxide, 84 disinfectant, 5% lysol, potassium permanganate and 75% medical alcohol were significantly different among Penicillium spp., but did not among Tri- choderma spp. [Conclusion] Bromogeramine bromide can be used to control the bacteria and fungi in mushroom production for it has significant inhibitory effects on the six species of both Penicillium and Trichoderma.展开更多
The prevalence of antibiotic susceptibility and disinfectant resistance in bacterial pathogens causes a serious problem not only to food safety but also to public health, which directly or indirectly leads to treatmen...The prevalence of antibiotic susceptibility and disinfectant resistance in bacterial pathogens causes a serious problem not only to food safety but also to public health, which directly or indirectly leads to treatment and disinfection failures. In this review, multidrug resistance, the mechanism of disinfectant resistance, the methods for detecting disinfectant resistance and the cross-resistance between an- tibiotics and disinfectants are summarized. More efforts should be devoted to explor- ing the professional guidance of using antibiotics and disinfectants, and to develop- ing the comprehensive detection with genetic and molecular methods is highly ex- pected.展开更多
Objective To prepare and evaluate novel chlorine dioxide-based disinfectant powder in single-pack that is more convenient for use and transportation. Methods Orthogonal experiment was performed to determine the recipe...Objective To prepare and evaluate novel chlorine dioxide-based disinfectant powder in single-pack that is more convenient for use and transportation. Methods Orthogonal experiment was performed to determine the recipe of the disinfectant powder. Stability test, suspension quantitative bactericidal test, simulation field triM, and animal toxicity test were carded out to observe its bactericidal and toxicological effects. Results The orthogonal experiment showed that the type of water solution had no effect on the disinfectant powder and the best ratio of sodium chlorite to solid acid was 1:3. Ten grams of the disinfectant powder was fully dissolved in 20 mL water for 2 min, and diluted to 500 mL in water. After 5-10 min, the concentration of chlorine dioxide (CIO2) solution was 266 mg/L to 276 mg/L. After stored at 54℃ for 14 d, the average concentration of CIO2 was decreased by 5.03%. Suspension quantitative bactericidal test showed that the average killing logarithm (KL) value for both Staphylococcus aureus and Escherichia coli in 100 mg/L CIO2 solution for 2 min was over 5.00. In simulation field triM, the average descending KL value for Escherichia coli in the solution containing 100 mg/L CIO2 for 5 min was over 3.00. The mouse acute LD50 in the solution 5 times exceeded 5000 mg/kg. The disinfectant powder was not toxic and irritative to rabbit skin and had no mutagenic effect on mouse marrow polychromatic erythrocytes (PCE). Conclusion The stability and bactericidal efficacy of solid chlorine dioxide-based disinfectant powder in single-pack are good. The solution containing 100 mg/L CIO2 can kill vegetative forms of bacteria. The concentration of CIO2 on the disinfecting surface of objects is 100 mg/L. The disinfectant powder is not toxic and irritative.展开更多
A compound disinfectant, which consisted of didecyldimethylammonium chloride (DDAC), ortho-dichlorobenzene (1,2-dichlorobenzene, ODB), and chlorocresol (4-chloro-3-methylphenol, CC), and its component chemicals were i...A compound disinfectant, which consisted of didecyldimethylammonium chloride (DDAC), ortho-dichlorobenzene (1,2-dichlorobenzene, ODB), and chlorocresol (4-chloro-3-methylphenol, CC), and its component chemicals were individually tested for effectiveness against bovine herpes virus type 1 (BHV-1). DDAC, DDAC+ODB, DDAC+CC, and DDAC+ODB+CC showed effectiveness against BHV-1 at room temperature. However, ODB, CC, and ODB+CC showed no virucidal effects. The effects of all disinfectants tested were decreased at low temperature. DDAC showed disinfectant effects at a dilution of 1/800 and DDAC+ODB, DDAC+CC, and DDAC+ODB+CC at dilutions of 1/800 and 1/1600 at low temperature in the presence of 2% fetal bovine serum (FBS) but ODB, CC, and ODB+CC showed no virucidal effects. At low temperature and in the presence of 10% FBS, DDAC, DDAC+ODB, and DDAC+CC showed disinfectant effects at dilutions of 1/800, whereas ODB, CC, and ODB+CC showed no virucidal effects. DDAC+ ODB+CC was more effective (at 1/800 and 1/1600) than the other disinfectants under these conditions. In conclusion, a combination of three disinfectant components (DDAC+ODB+CC), enhanced the disinfectant effects at low temperature and in organic matter contamination.展开更多
Aim: This study aims to assess the infection risks of flashlight contamination in a stomatology hospital and compare the disinfection effectiveness of alcohol (75%) and disinfecting wipes.Background: The flashlight is...Aim: This study aims to assess the infection risks of flashlight contamination in a stomatology hospital and compare the disinfection effectiveness of alcohol (75%) and disinfecting wipes.Background: The flashlight is a basic non-critical medical device in oral and maxillofacial surgery wards. Wounds are mostly found in oral cavities;therefore, reusable flashlights may be a potential source of nosocomial infections (NIs). However, the microbial flora present in flashlights used in hospitals has not yet been explored. Methods: This study investigated the microbial contamination of 41 flashlights used in a stomatology hospital in Guangzhou in March 2016. Results: Results indicated that 75.6%(31/41) of the flashlights had microbial contamination. Gram-positive bacteria accounted for 72.7%(24/33)of the microbial groups contaminating the flashlights, and Gram-negative bacteria (21.2%, 7/33), and fungi (6.1%, 2/33) constituted the remaining contaminants. The predominantly isolated species was Staphyloccus (66.7%, 22/33), especially Staphylococcus aureus (24.2%, 8/33). Approximately 77.3%(17/22) of the types of bacteria detected in the hands were same as those in the corresponding flashlights. Both the bacterial overstandard and S. aureus detection rates of doctors' flashlights were higher than those of nurses' flashlights (16/17 vs. 14/23, 7/17 vs. 1/23, respectively) (P < 0.05). Moreover, both disinfectants performed excellently, and their eligibility rates were not significantly different (17/17 vs. 14/14) (P>0.05). Conclusion: Flashlights are potential causes of NIs. Disinfecting flashlights could be an effective and practical infection control method.展开更多
BACKGROUND Misuse of disinfectants during the coronavirus disease 2019 pandemic has led to several poisoning incidents.However,there are few clinical case reports on poisoning caused by improper mixing of household di...BACKGROUND Misuse of disinfectants during the coronavirus disease 2019 pandemic has led to several poisoning incidents.However,there are few clinical case reports on poisoning caused by improper mixing of household disinfectants.AIM To summarize the clinical characteristics and treatment effects of chlorine poisoning caused by improper mixing of hypochlorite bleach with acidic cleaning agents.METHODS We retrospectively analyzed baseline and clinical data,clinical symptoms,and treatment methods of seven patients with chlorine poisoning who were admitted to the National Army Poisoning Treatment Center.RESULTS Among the seven patients,the average poisoning time(exposure to admission)was 57 h(4-240 h).All patients were involved in cleaning bathrooms.Chest computed tomography scans revealed bilateral lung effusions or inflammatory changes in five patients.The partial pressure of oxygen decreased in six patients,and respiratory failure occurred in one.Five patients had different degrees of increase in white blood cell count.Humidified oxygen therapy,non-invasive mechanical ventilation,anti-inflammatory corticosteroids,antioxidants,and antibiotics were administered for treatment.The average length of hospital stay was 7 d(4-9 d).All seven patients recovered and were discharged.CONCLUSION Improper mixing of household disinfectants may cause damage to the respiratory system due to chlorine poisoning.Corticosteroids may improve lung exudation in severe cases,and symptomatic supportive treatment should be performed early.展开更多
This review provides an insight and up-to-date information on the application of Moringa oleifera seeds, the short falls of existing technologies as a coagulant and disinfectant in domestic water treatment. While the ...This review provides an insight and up-to-date information on the application of Moringa oleifera seeds, the short falls of existing technologies as a coagulant and disinfectant in domestic water treatment. While the coagulant properties are well reported, the disinfectant properties are not well studied. Literatures on low cost alternative technologies such as the application of hiocoagulants and slow sand filters are extensively reported. However, there is limited work addressing the limitations of these technologies that have restricted its widespread use to solve the global soaring water crises. Slow sand filters have a very slow filtration rate that depends on the biofilm layer which takes about 17 days to form. Moringa oleifera treated water cannot last more than 48 hours without bacteria regrowth. Investigation of the best method of isolating coagulant component continues with differing opinions over the nature of its coagulant ingredient not resolved in ongoing literature. An attempt was made in this paper to highlight the advantages of a Moringa disinfectant sand filter hybrid system that can purify water. Microbiological advantages of this system in providing a 100% removal of pathogens, and engineering considerations such as water treatment within an hour residence time, faster flow rates, less clogging and backwashing could be some of the advantages ofa Moringa sand filter system. The need to focus on integrating Moringa and sand filter systems for more practical applications is recommended.展开更多
Acacia bark efficiency for disinfecting polluted water for the purpose of using it for drinking purposes was tested. Five polluted water samples were collected from different locations in Jordan, namely, King Abdullah...Acacia bark efficiency for disinfecting polluted water for the purpose of using it for drinking purposes was tested. Five polluted water samples were collected from different locations in Jordan, namely, King Abdullah Canal, an Agricultural pond in the Jordan Valley, Yajouz wells, Hazeir spring, and Wadi-Seer spring. Different volumes of the water samples were treated with 10 g of the shredded acacia bark (obtained from Somalia) for different retention times. The volumes used were 1 L, 2.5 L, and 5 L and the detention times were 2, 4, and 24 hours. The samples were tested for total coliform, E. coli, electrical conductivity, pH, total dissolved solids, turbidity and color before and after treatment with the acacia bark. Results revealed that the optimum conditions for disinfection were: 1 L polluted water treated with 10 g acacia bark for 24 hours. Log removals of about 2.5 for E. coli were obtained under these conditions. Higher removals could be achieved by using larger amounts of the acacia bark, but the chemical water quality regarding turbidity and color will not be suitable for drinking purposes and levels of tannic acids present in the acacia bark might reach toxic levels. Toxic levels will not be reached if 1 glass of water/kg body weight every 4 - 5 hours daily is consumed.展开更多
Objective: Infection control protocols dictate the disinfection of dentures. There are no products available which are designed for the specific use of disinfecting dentures. The objective of this study was to investi...Objective: Infection control protocols dictate the disinfection of dentures. There are no products available which are designed for the specific use of disinfecting dentures. The objective of this study was to investigate the impact of chemical disinfectants on elastic modulus, flexural strength and color stability of denture base resins. Methods: 256 specimens from four acrylic denture base resins were manufactured. Two cold-curing denture base resins: PalaXpress (Heraeus Kulzer, Hanau, Germany), Futura Gen (Schuetz Dental, Roßbach, Germany) and two heat-curing denture base resins: Paladon 65 (Heraeus Kulzer, Hanau, Germany), FuturAcryl 2000 (Schuetz Dental, Roßbach, Germany) were used. Three chemical disinfecting agents were tested: Impresept, D050 Instru-Gen, Stammopur DR. Specimens were stored in distilled water and in chemical disinfecting agents. They were divided randomly into groups. E-Modulus and flexural strength were measured using the three-point bending test. Color changes (ΔE) were determined spectrophotometrically. Results: The disinfection agents showed no significant influence on the E-modulus compared to distilled water (Acrylic vs. distilled water from (Futura Gen) 2688.80 ± 230.78 vs. 2766.60 ± 91.22 MPa to (PalaXpress) 3004.20 ± 26.40 vs. 2851.00 ± 95.23 MPa). Flexural strength after storage in distilled water and disinfection did not differ significantly (Acrylic vs. distilled water from (Paladon65) 27.28 ± 1.30 vs. 28.42 ± 0.84 N/mm2, (p > 0.05) to (PalaXpress) 30.88 ± 0.25 vs. 29.68 ± 0.79 N/mm2, p < 0.001). Disinfection caused a significant color change with Impresept of Paladon 65 (p ≤ 0.001), FuturaAcryl 2000 with Stammopur DR and D 050 Instru-Gen (p ≤ 0.001). Conclusions: The investigated disinfection agents did not influence elastic modulus and flexural strength of denture base resins negatively. ΔE-values were in a range of 1 to 2. Thus, the detected color changes may be marginal. Clinical relevance: Single use disinfections are feasible for acrylic dentures regarding to elastic modulus and flexural strength.展开更多
基金supported by the America University,the Swiss Agency for Development and Cooperation,and the Central Technical Institute.
文摘Sodium hypochlorite has significant potential as a sanitation solution in hard-to-reach areas.Few studies have investigated the optimal electrolysis parameters for its production with volumes greater than 1o L.This study evaluated sodium hypochlorite production through electrolysis in a 22-L prototype and identified the optimal operating parameters.Tests were performed using graphite electrodes with areas of 68.4 cm^(2) at the laboratory scale and 1865.0 cm^(2) at the prototype scale.A design for experiments with different operating times,chloride concentrations,and electric current intensities was developed.The optimal operating time,sodium chloride concentration,and current intensity at the laboratory scale were 120 min,150 g of chloride per liter,and 3 A,respectively,leading to the production of 5.02 g/L of the disinfectant with an energy efficiency of 12.21 mg of Cl_(2) per kilojoule.At the prototype scale,the maximum sodium hypochlorite concentration of 3.99 g of chloride per liter was achieved with an operating time of 120 min,a sodium chloride concentration of 100 g of chloride per liter,and a current intensity of 70 A,reaching an energy efficiency of 42.56 mg of Cl_(2) per kilojoule.In addition,this study evaluated the influences of the chloride concentration,current intensity,and operating time on the production of sodium hypochlorite at the two scales,and formulated the equations showing the trends of sodium hypochlorite production and energy efficiency in the electrochemical systems.The 22-L prototype model for production of this oxidizing substance is promising for disinfection of large volumes of water in areas that are difficult to access.
基金supported by National Key R&D Program of China[grant number:2021YFC0863000]。
文摘Objective To study the effectiveness and feasibility of cryogenic disinfectants in different cold scenarios and analyze the key points of on-site cryogenic disinfection.Methods Qingdao and Suifenhe were selected as application sites for the manual or mechanical spraying of cryogenic disinfectants.The same amount of disinfectant(3,000 mg/L)was applied on cold chain food packaging,cold chain containers,transport vehicles,alpine environments,and article surfaces.The killing log value of the cryogenic disinfectant against the indicator microorganisms(Staphylococcus aureus and Escherichia coli)was used to evaluate the on-site disinfection effect.Results When using 3,000 mg/L with an action time of 10 min on the ground in alpine regions,the surface of frozen items,cold-chain containers,and cold chain food packaging in supermarkets,all external surfaces were successfully disinfected,with a pass rate of 100%.The disinfection pass rates for cold chain food packaging and cold chain transport vehicles of centralized supervised warehouses and food processing enterprises were 12.5%(15/120),81.67%(49/60),and 93.33%(14/15),respectively;yet,the surfaces were not fully sprayed.Conclusion Cryogenic disinfectants are effective in disinfecting alpine environments and the outer packaging of frozen items.The application of cryogenic disinfectants should be regulated to ensure that they cover all surfaces of the disinfected object,thus ensuring effective cryogenic disinfection.
基金Funded by the Xuhui District Medical Research Project(No.SHXH201913)the Clinical Research on Health Industry of Shanghai Municipal Health Commission(No.202040085)+1 种基金the Shanghai Medical Key Specialty(No.ZK2019B12)the National Natural Science Foundation of China(No.32000945)。
文摘To investigate the corrosion behaviors and antibacterial effects of sodium hypochlorite(NaClO)and hydrogen peroxide silver ion(HPSI)disinfectants with different concentrations against dental unit waterlines and provide guidance and reference for the use of chemical disinfectants,polyurethane tubes were immersed in ultrapure water(control group),0.1%NaClO,0.5%NaClO,1.0%NaClO,2.5%HPSI,5.0%HPSI,and 10%HPSI solutions for 6,12,and 18 weeks.Contact angles and Fourier transform infrared spectra were detected.Surface morphologies were observed using scanning electron microscopy and antibacterial activity was evaluated using Gram-positive Staphylococcus aureus(S.aureus).The results showed that sodium hypochlorite and hydrogen peroxide silver ion disinfectants presented good antibacterial activity against S.aureus.However,sodium hypochlorite could cause serious damage to the water pipes where corrosion pits and cracks were observed,and increasing the concentration of sodium hypochlorite could accelerate the corrosion process.Hydrogen peroxide silver ion disinfectants had no obvious damage to the water pipes.Therefore,hydrogen peroxide silver ion disinfectants are recommended to use for controlling bacterial infection in dental unit waterlines which can reduce the damage to the water pipes.
基金supported by the National Natural Science Foundation of China(52325001,52170009,and 52091542)the National Key Research and Development Program of China(2021YFC3200700)+3 种基金the Program of Shanghai Academic Research Leader,China(21XD1424000)the International Cooperation Project of Shanghai Science and Technology Commission(20230714100)the Key-Area Research and Development Program of Guangdong Province(2020B1111350001)Tongji University Youth 100 Program.
文摘Tracing the contamination origins in water sources and identifying the impacts of natural and human processes are essential for ecological safety and public health.However,current analysis approaches are not ideal,as they tend to be laborious,time-consuming,or technically difficult.Disinfection byproducts(DBPs)are a family of well-known secondary pollutants formed by the reactions of chemical disinfectants with DBP precursors during water disinfection treatment.Since DBP precursors have various origins(e.g.,natural,domestic,industrial,and agricultural sources),and since the formation of DBPs from different precursors in the presence of specific disinfectants is distinctive,we argue that DBPs and DBP precursors can serve as alternative indicators to assess the contamination in water sources and identify pollution origins.After providing a retrospective of the origins of DBPs and DBP precursors,as well as the specific formation patterns of DBPs from different precursors,this article presents an overview of the impacts of various natural and anthropogenic factors on DBPs and DBP precursors in drinking water sources.In practice,the DBPs(i.e.,their concentration and speciation)originally present in source water and the DBP precursors determined using DBP formation potential tests—in which water samples are dosed with a stoichiometric excess of specific disinfectants in order to maximize DBP formation under certain reaction conditions—can be considered as alternative metrics.When jointly used with other water quality parameters(e.g.,dissolved organic carbon,dissolved organic nitrogen,fluorescence,and molecular weight distribution)and specific contaminants of emerging concern(e.g.,certain pharmaceuticals and personal care products),DBPs and DBP precursors in drinking water sources can provide a more comprehensive picture of water pollution for better managing water resources and ensuring human health.
基金The Natural Science Research Project of Minhang District,No.2021MHZ070.
文摘BACKGROUND Aerosols containing disease-causing microorganisms are produced during oral diagnosis and treatment can cause secondary contamination.AIM To investigate the use of graphene material for air disinfection in dental clinics by leveraging its adsorption and antibacterial properties.METHODS Patients who received ultrasonic cleaning at our hospital from April 2023 to April 2024.They were randomly assigned to three groups(n=20 each):Graphene nanocomposite material suction group(Group A),ordinary filter suction group(Group B),and no air suction device group(Group C).The air quality and air colony count in the clinic rooms were assessed before,during,and after the procedure.Additionally,bacterial colony counts were obtained from the air outlets of the suction devices and the filter screens in Groups A and B.RESULTS Before ultrasonic cleaning,no significant differences in air quality PM2.5 and colony counts were observed among the three groups.However,significant differences in air quality PM2.5 and colony counts were noted among the three groups during ultrasonic cleaning and after ultrasonic treatment.Additionally,the number of colonies on the exhaust port of the suction device and the surface of the filter were significantly lower in Group A than in Group B(P=0.000 and P=0.000,respectively).CONCLUSION Graphene nanocomposites can effectively sterilize the air in dental clinics by exerting their antimicrobial effects and may be used to reduce secondary pollution.
文摘This study aimed to examine the effect of different disinfection methods on the callus of Amorphophallus albus in the tissue culture and rapid propagation system.The calluses induced from buds of A.albus were disinfected with benzalkonium bromide,mercury bichloride,sodium hypochlorite,and ethanol,respectively,for different time periods.The growth of calluses was compared between different treatments and observed in detail by dissection.The results showed that the disinfection with 0.1% mercury bichloride for 5 min and 75% ethanol for 5 s had mild effect on the callus,with the lowest browning rates of 16.32% and 15.46% and the lowest vitrification rates of 3.24% and 9.72%,respectively,after 20 d.The disinfection with benzalkonium bromide and sodium hypochlorite had strong effect on the callus cells,with the lowest browning rate of 50.69% and 25.12% and the lowest vitrification rates of 28.47% and 28.43%,respectively.The cytological observation result showed that the calluses disinfected with ethanol and mercury bichloride showcased compact structures,while those disinfected with sodium hypochlorite and benzalkonium bromide exhibited loose structures.To sum up,it is recommended that 75% ethanol or 0.1% mercury bichloride can be used for disinfection in the tissue culture and rapid propagation of A.albus,while the use of benzalkonium bromide and sodium hypochlorite should be avoided as much as possible.
文摘Objective:To evaluate the application value of a refined quality control management model for a sterilization supply center.Methods:A retrospective analysis was conducted on the work situation of the sterilization supply center from January 2021 to January 2023.The work situation before January 31,2022,was classified as the control group;a routine quality control management model was implemented,and the work situation after January 31,2022,was classified as the observation group.The quality of medical device management and department satisfaction between the two groups were compared.Results:The timely recovery and supply rate,classification and cleaning pass rate,disinfection pass rate,packaging pass rate,sterilization pass rate,and department satisfaction score in the observation group were all higher than those of the control group(P<0.05).Conclusion:Implementing a refined quality control management model in the sterilization supply center can improve the quality management level of medical devices and department satisfaction and is worthy of promotion.
基金supported by National Natural Science Foundation of China(52208272,41706080 and 51702328)the Basic Scientific Fund for National Public Research Institutes of China(2020S02 and 2019Y03)+3 种基金the Basic Frontier Science Research Program of Chinese Academy of Sciences(ZDBS-LY-DQC025)the Young Elite Scientists Sponsorship Program by CAST(No.YESS20210201)the Strategic Leading Science&Technology Program of the Chinese Academy of Sciences(XDA13040403)the Key Research and Development Program of Shandong Province(Major Scientific and Technological Innovation Project)(2019JZZY020711).
文摘Since the catalytic activity of most nanozymes is still far lower than the corresponding natural enzymes,there is urgent need to discover novel highly efficient enzyme-like materials.In this work,Co_(3)V_(2)O_(8)with hollow hexagonal prismatic pencil structures were prepared as novel artificial enzyme mimics.They were then decorated by photo-depositing Ag nanoparticles(Ag NPs)on the surface to further improve its catalytic activities.The Ag NPs decorated Co_(3)V_(2)O_(8)(ACVPs)showed both excellent oxidase-and peroxidase-like catalytic activities.They can oxidize the colorless 3,3’,5,5’-tetramethylbenzidine rapidly to induce a blue change.The enhanced enzyme mimetic activities can be attributed to the surface plasma resonance(SPR)effect of Ag NPs as well as the synergistic catalytic effect between Ag NPs and Co_(3)V_(2)O_(8),accelerating electron transfer and promoting the catalytic process.ACVPs were applied in constructing a colorimetric sensor,validating the occurrence of the Fenton reaction,and disinfection,presenting favorable catalytic performance.The enzyme-like catalytic mechanism was studied,indicating the chief role of⋅O_(2)-radicals in the catalytic process.This work not only discovers a novel functional material with double enzyme mimetic activity but also provides a new insight into exploiting artificial enzyme mimics with highly efficient catalytic ability.
文摘BACKGROUND Pelvic floor dysfunction(PFD)is related to muscle fiber tearing during childbirth,negatively impacting postpartum quality of life of parturient.Appropriate and effective intervention is necessary to promote PFD recovery.AIM To analyze the use of hydrogen peroxide and silver ion disinfection for vaginal electrodes in conjunction with comprehensive rehabilitation therapy for postpartum women with PFD.METHODS A total of 59 women with PFD who were admitted to the hospital from May 2019 to July 2022 were divided into two groups:Control group(n=27)received comprehensive rehabilitation therapy and observation group(n=32)received intervention with pelvic floor biostimulation feedback instrument in addition to comprehensive rehabilitation therapy.The vaginal electrodes were disinfected with hydrogen peroxide and silver ion before treatment.Intervention for both groups was started 6 weeks postpartum,and rehabilitation lasted for 3 months.Pelvic floor muscle voltage,pelvic floor muscle strength,vaginal muscle voltage,vaginal muscle tone,pelvic floor function,quality of life,and incidence of postpartum PFD were compared between the two groups.RESULTS Before comprehensive rehabilitation treatment,basic data and pelvic floor function were not significantly different between the two groups.After treatment,the observation group showed significant improvements in the maximum voltage and average voltage of pelvic floor muscles,contraction time of type I and type II fibers,pelvic floor muscle strength,vaginal muscle tone,vaginal muscle voltage,and quality of life(GQOLI-74 reports),compared with the control group.The observation group had lower scores on the pelvic floor distress inventory(PFDI-20)and a lower incidence of postpartum PFD,indicating the effectiveness of the pelvic floor biostimulation feedback instrument in promoting the recovery of maternal pelvic floor function.CONCLUSION The combination of the pelvic floor biostimulation feedback instrument and comprehensive rehabilitation nursing can improve pelvic floor muscle strength,promote the recovery of vaginal muscle tone,and improve pelvic floor function and quality of life.The use of hydrogen peroxide and silver ion disinfectant demonstrated favorable antibacterial efficacy and is worthy of clinical application.
基金Fundação de Amparo a Pesquisa do Estado de São Paulo(FAPESP)and the Conselho Nacional de Desenvolvimento Científico e Tecnológico(CNPq),São Paulo,Brazil for PhD scholarship(Process N°.141086/2015-7)financial support(Process No.870243/1997-7).
文摘The UV irradiation is used for removing Antibiotic Resistant Bacteria(ARB)and Antibiotic Resistance Genes(ARG)from wastewater treatment.Bacteriophages are viruses that infect within bacteria,are recognized for bacterial control.The influence of some parameters in quantification and performance influencing of pathogen demobilization could be considered in disinfection of wastewater.The comparison of Polyvalent phage(NE1)versus Coliphage(NE4)in suppressing a bacterium Escherichia coli(NDM-1:b-lactam-resistant)with UV irradiation was observed the efficacy in reduction of cells in the disinfection and parameter process.The results with the effect of UV-C irradiation on NDM-1 infected with 1%of NE4 showed a decrease of cells from 8×10^(6)to 2×10^(5)in 60 min with UV-C dose.The NDM1(E.coli)was infected with 1%of NE4(Polyvalent Phage)under magnetic stirring for 1 h,the cells count was 8×10^(6).After 1 h in UV-C e×posure,the cells number reached 3×10^(5).The NDM1 that was e×posed in 1 h of UV-C irradiation and then was infected with 1%of NE4.Cells counting were done 24 h after this procedure.These cells were e×posed in UV-C and showed a reduction in the number of cells from 1×10^(8)to 4×10^(5)after 60 min.The results indicate that bacteriophages can mitigate bacteria species,and combined the conventional water disinfection technologies that can support the microbial safety control strategies.
文摘Ensuring the health and safety of drinking water is crucial for both nations and their citizens.Since the 20th century,the disinfection of drinking water,effectively controlling pathogens in water sources,has become one of the significant advances in public health.However,the disinfectants used in the process,such as chlorine and chlorine dioxide,react with natural organic matter in the water to produce disinfection by-products(DBPs).Most of these DBPs contain chlorine,and if the source water contains bromine or iodine,brominated or iodinated DBPs,collectively referred to as Halogenated disinfection byproducts(X-DBPs),are formed.Numerous studies have found that X-DBPs pose potential risks to human health and the environment,leading to widespread concern.Mass spectrometry has become an important means of discovering new types of X-DBPs.This paper focuses on the study of methods for analyzing X-DBPs in drinking water using mass spectrometry.
文摘[Objective] This study was conducted to investigate the effects of Penicillium spp. and Trichoderma spp. on the growth of Pleurotus ostreatus (oyster mushroom) and to screen effective disinfectants to control them and other pathogenic microbes. [Method] Six strains or species of Penicilliurn and Trichoderma were inocu- lated into PDA plates growing with P. ostreatus to observe the growth of their mycelia. And the inhibitory effects of hydrogen peroxide, bromogeramine bromide, 84 disinfectant, lysol, potassium permanganate, and 75% medical alcohol on Trichoderma pleuroticola, Trichoderma viride, Trichoderma harzianum, Penicillium citrinum, Penicillium thomii and Penicillium brevicompactum were detected. [Result] Confrontation test revealed that Penicillium spp. and Trichoderma spp. competed for nutrients with P. ostreatus mycelia, antagonized against the growth of P. ostreatus mycelia, invaded and twined around P. ostreatus mycelia, and also produced toxins poisoning P. ostreatus mycelia. The six disinfectants exhibited different inhibitory effects against different species of Penicillium and Trichoderma. Among them the in- hibitory effects of bromogeramine bromide against the six species of Penicillium and Trichoderma were significantly different. However, the inhibitory effects of 3% hydrogen peroxide, 84 disinfectant, 5% lysol, potassium permanganate and 75% medical alcohol were significantly different among Penicillium spp., but did not among Tri- choderma spp. [Conclusion] Bromogeramine bromide can be used to control the bacteria and fungi in mushroom production for it has significant inhibitory effects on the six species of both Penicillium and Trichoderma.
基金Supported by the National Key Research and Development Program of China(2016YFD0501208)the Social Development Program of Yangzhou(YZ2016058)+1 种基金the National Major Project for Agro-product Quality&Safety Risk Assessment(GJFP2017007)the Project for the Construction of Science and Technology Service Platform for Poultry Quality and Safety of Yangzhou(yz2015162)~~
文摘The prevalence of antibiotic susceptibility and disinfectant resistance in bacterial pathogens causes a serious problem not only to food safety but also to public health, which directly or indirectly leads to treatment and disinfection failures. In this review, multidrug resistance, the mechanism of disinfectant resistance, the methods for detecting disinfectant resistance and the cross-resistance between an- tibiotics and disinfectants are summarized. More efforts should be devoted to explor- ing the professional guidance of using antibiotics and disinfectants, and to develop- ing the comprehensive detection with genetic and molecular methods is highly ex- pected.
文摘Objective To prepare and evaluate novel chlorine dioxide-based disinfectant powder in single-pack that is more convenient for use and transportation. Methods Orthogonal experiment was performed to determine the recipe of the disinfectant powder. Stability test, suspension quantitative bactericidal test, simulation field triM, and animal toxicity test were carded out to observe its bactericidal and toxicological effects. Results The orthogonal experiment showed that the type of water solution had no effect on the disinfectant powder and the best ratio of sodium chlorite to solid acid was 1:3. Ten grams of the disinfectant powder was fully dissolved in 20 mL water for 2 min, and diluted to 500 mL in water. After 5-10 min, the concentration of chlorine dioxide (CIO2) solution was 266 mg/L to 276 mg/L. After stored at 54℃ for 14 d, the average concentration of CIO2 was decreased by 5.03%. Suspension quantitative bactericidal test showed that the average killing logarithm (KL) value for both Staphylococcus aureus and Escherichia coli in 100 mg/L CIO2 solution for 2 min was over 5.00. In simulation field triM, the average descending KL value for Escherichia coli in the solution containing 100 mg/L CIO2 for 5 min was over 3.00. The mouse acute LD50 in the solution 5 times exceeded 5000 mg/kg. The disinfectant powder was not toxic and irritative to rabbit skin and had no mutagenic effect on mouse marrow polychromatic erythrocytes (PCE). Conclusion The stability and bactericidal efficacy of solid chlorine dioxide-based disinfectant powder in single-pack are good. The solution containing 100 mg/L CIO2 can kill vegetative forms of bacteria. The concentration of CIO2 on the disinfecting surface of objects is 100 mg/L. The disinfectant powder is not toxic and irritative.
文摘A compound disinfectant, which consisted of didecyldimethylammonium chloride (DDAC), ortho-dichlorobenzene (1,2-dichlorobenzene, ODB), and chlorocresol (4-chloro-3-methylphenol, CC), and its component chemicals were individually tested for effectiveness against bovine herpes virus type 1 (BHV-1). DDAC, DDAC+ODB, DDAC+CC, and DDAC+ODB+CC showed effectiveness against BHV-1 at room temperature. However, ODB, CC, and ODB+CC showed no virucidal effects. The effects of all disinfectants tested were decreased at low temperature. DDAC showed disinfectant effects at a dilution of 1/800 and DDAC+ODB, DDAC+CC, and DDAC+ODB+CC at dilutions of 1/800 and 1/1600 at low temperature in the presence of 2% fetal bovine serum (FBS) but ODB, CC, and ODB+CC showed no virucidal effects. At low temperature and in the presence of 10% FBS, DDAC, DDAC+ODB, and DDAC+CC showed disinfectant effects at dilutions of 1/800, whereas ODB, CC, and ODB+CC showed no virucidal effects. DDAC+ ODB+CC was more effective (at 1/800 and 1/1600) than the other disinfectants under these conditions. In conclusion, a combination of three disinfectant components (DDAC+ODB+CC), enhanced the disinfectant effects at low temperature and in organic matter contamination.
基金This research was supported by the Extracurricular Scientific Research Program for Students of Sun Yat-Sen University
文摘Aim: This study aims to assess the infection risks of flashlight contamination in a stomatology hospital and compare the disinfection effectiveness of alcohol (75%) and disinfecting wipes.Background: The flashlight is a basic non-critical medical device in oral and maxillofacial surgery wards. Wounds are mostly found in oral cavities;therefore, reusable flashlights may be a potential source of nosocomial infections (NIs). However, the microbial flora present in flashlights used in hospitals has not yet been explored. Methods: This study investigated the microbial contamination of 41 flashlights used in a stomatology hospital in Guangzhou in March 2016. Results: Results indicated that 75.6%(31/41) of the flashlights had microbial contamination. Gram-positive bacteria accounted for 72.7%(24/33)of the microbial groups contaminating the flashlights, and Gram-negative bacteria (21.2%, 7/33), and fungi (6.1%, 2/33) constituted the remaining contaminants. The predominantly isolated species was Staphyloccus (66.7%, 22/33), especially Staphylococcus aureus (24.2%, 8/33). Approximately 77.3%(17/22) of the types of bacteria detected in the hands were same as those in the corresponding flashlights. Both the bacterial overstandard and S. aureus detection rates of doctors' flashlights were higher than those of nurses' flashlights (16/17 vs. 14/23, 7/17 vs. 1/23, respectively) (P < 0.05). Moreover, both disinfectants performed excellently, and their eligibility rates were not significantly different (17/17 vs. 14/14) (P>0.05). Conclusion: Flashlights are potential causes of NIs. Disinfecting flashlights could be an effective and practical infection control method.
基金Supported by the National Natural Science Foundation of China,No.81873116。
文摘BACKGROUND Misuse of disinfectants during the coronavirus disease 2019 pandemic has led to several poisoning incidents.However,there are few clinical case reports on poisoning caused by improper mixing of household disinfectants.AIM To summarize the clinical characteristics and treatment effects of chlorine poisoning caused by improper mixing of hypochlorite bleach with acidic cleaning agents.METHODS We retrospectively analyzed baseline and clinical data,clinical symptoms,and treatment methods of seven patients with chlorine poisoning who were admitted to the National Army Poisoning Treatment Center.RESULTS Among the seven patients,the average poisoning time(exposure to admission)was 57 h(4-240 h).All patients were involved in cleaning bathrooms.Chest computed tomography scans revealed bilateral lung effusions or inflammatory changes in five patients.The partial pressure of oxygen decreased in six patients,and respiratory failure occurred in one.Five patients had different degrees of increase in white blood cell count.Humidified oxygen therapy,non-invasive mechanical ventilation,anti-inflammatory corticosteroids,antioxidants,and antibiotics were administered for treatment.The average length of hospital stay was 7 d(4-9 d).All seven patients recovered and were discharged.CONCLUSION Improper mixing of household disinfectants may cause damage to the respiratory system due to chlorine poisoning.Corticosteroids may improve lung exudation in severe cases,and symptomatic supportive treatment should be performed early.
文摘This review provides an insight and up-to-date information on the application of Moringa oleifera seeds, the short falls of existing technologies as a coagulant and disinfectant in domestic water treatment. While the coagulant properties are well reported, the disinfectant properties are not well studied. Literatures on low cost alternative technologies such as the application of hiocoagulants and slow sand filters are extensively reported. However, there is limited work addressing the limitations of these technologies that have restricted its widespread use to solve the global soaring water crises. Slow sand filters have a very slow filtration rate that depends on the biofilm layer which takes about 17 days to form. Moringa oleifera treated water cannot last more than 48 hours without bacteria regrowth. Investigation of the best method of isolating coagulant component continues with differing opinions over the nature of its coagulant ingredient not resolved in ongoing literature. An attempt was made in this paper to highlight the advantages of a Moringa disinfectant sand filter hybrid system that can purify water. Microbiological advantages of this system in providing a 100% removal of pathogens, and engineering considerations such as water treatment within an hour residence time, faster flow rates, less clogging and backwashing could be some of the advantages ofa Moringa sand filter system. The need to focus on integrating Moringa and sand filter systems for more practical applications is recommended.
文摘Acacia bark efficiency for disinfecting polluted water for the purpose of using it for drinking purposes was tested. Five polluted water samples were collected from different locations in Jordan, namely, King Abdullah Canal, an Agricultural pond in the Jordan Valley, Yajouz wells, Hazeir spring, and Wadi-Seer spring. Different volumes of the water samples were treated with 10 g of the shredded acacia bark (obtained from Somalia) for different retention times. The volumes used were 1 L, 2.5 L, and 5 L and the detention times were 2, 4, and 24 hours. The samples were tested for total coliform, E. coli, electrical conductivity, pH, total dissolved solids, turbidity and color before and after treatment with the acacia bark. Results revealed that the optimum conditions for disinfection were: 1 L polluted water treated with 10 g acacia bark for 24 hours. Log removals of about 2.5 for E. coli were obtained under these conditions. Higher removals could be achieved by using larger amounts of the acacia bark, but the chemical water quality regarding turbidity and color will not be suitable for drinking purposes and levels of tannic acids present in the acacia bark might reach toxic levels. Toxic levels will not be reached if 1 glass of water/kg body weight every 4 - 5 hours daily is consumed.
文摘Objective: Infection control protocols dictate the disinfection of dentures. There are no products available which are designed for the specific use of disinfecting dentures. The objective of this study was to investigate the impact of chemical disinfectants on elastic modulus, flexural strength and color stability of denture base resins. Methods: 256 specimens from four acrylic denture base resins were manufactured. Two cold-curing denture base resins: PalaXpress (Heraeus Kulzer, Hanau, Germany), Futura Gen (Schuetz Dental, Roßbach, Germany) and two heat-curing denture base resins: Paladon 65 (Heraeus Kulzer, Hanau, Germany), FuturAcryl 2000 (Schuetz Dental, Roßbach, Germany) were used. Three chemical disinfecting agents were tested: Impresept, D050 Instru-Gen, Stammopur DR. Specimens were stored in distilled water and in chemical disinfecting agents. They were divided randomly into groups. E-Modulus and flexural strength were measured using the three-point bending test. Color changes (ΔE) were determined spectrophotometrically. Results: The disinfection agents showed no significant influence on the E-modulus compared to distilled water (Acrylic vs. distilled water from (Futura Gen) 2688.80 ± 230.78 vs. 2766.60 ± 91.22 MPa to (PalaXpress) 3004.20 ± 26.40 vs. 2851.00 ± 95.23 MPa). Flexural strength after storage in distilled water and disinfection did not differ significantly (Acrylic vs. distilled water from (Paladon65) 27.28 ± 1.30 vs. 28.42 ± 0.84 N/mm2, (p > 0.05) to (PalaXpress) 30.88 ± 0.25 vs. 29.68 ± 0.79 N/mm2, p < 0.001). Disinfection caused a significant color change with Impresept of Paladon 65 (p ≤ 0.001), FuturaAcryl 2000 with Stammopur DR and D 050 Instru-Gen (p ≤ 0.001). Conclusions: The investigated disinfection agents did not influence elastic modulus and flexural strength of denture base resins negatively. ΔE-values were in a range of 1 to 2. Thus, the detected color changes may be marginal. Clinical relevance: Single use disinfections are feasible for acrylic dentures regarding to elastic modulus and flexural strength.