期刊文献+
共找到708篇文章
< 1 2 36 >
每页显示 20 50 100
Performance analysis on a novel water chiller using liquid desiccant
1
作者 曹熔泉 张小松 殷勇高 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期192-196,共5页
A new type of liquid desiccant water chiller for applications on air-conditioning and refrigeration is introduced.The system can be driven by low-grade heat sources with temperatures of 60 to 80 ℃,which can be easily... A new type of liquid desiccant water chiller for applications on air-conditioning and refrigeration is introduced.The system can be driven by low-grade heat sources with temperatures of 60 to 80 ℃,which can be easily obtained by a flat plat solar collector,waste heat,etc.A numerical model is developed to study the system performance.The effects of different parameters on performance are discussed,including evaporating temperature,regenerating temperature,ambient condition,and mass flow rates of closed moist air and regenerating air.The results show that an acceptable performance of a cooling capacity of 2.5 kW and a coefficient of performance of 0.37 can be achieved in a reference case.The regenerating temperature and the humidity ratios of ambient air are two main factors affecting system performance,while the temperature of ambient air functions less.In addition,the mass flow rate of regenerating air and closed moist air should be carefully determined for economical operation. 展开更多
关键词 liquid desiccant water chiller coefficient of perfor-mance low-grade energy utilization
下载PDF
Energy, Exergy and Thermoeconomics Analysis of Water Chiller Cooler for Gas Turbines Intake Air Cooling 被引量:1
2
作者 Galal Mohammed Zaki Rahim Kadhim Jassim Majed Moalla Alhazmy 《Smart Grid and Renewable Energy》 2011年第3期190-205,共16页
Gas turbine (GT) power plants operating in arid climates suffer a decrease in output power during the hot summer months because of the high specific volume of air drawn by the compressor. Cooling the air intake to the... Gas turbine (GT) power plants operating in arid climates suffer a decrease in output power during the hot summer months because of the high specific volume of air drawn by the compressor. Cooling the air intake to the compressor has been widely used to mitigate this shortcoming. Energy and exergy analysis of a GT Brayton cycle coupled to a refrigeration air cooling unit shows a promise for increasing the output power with a little decrease in thermal efficiency. A thermo-economics algorithm is developed to estimate the economic feasibility of the cooling system. The analysis is applied to an open cycle, HITACHI-FS7001B GT plant at the industrial city of Yanbu (Latitude 24o 05” N and longitude 38o E) by the Red Sea in the Kingdom of Saudi Arabia. Result show that the enhancement in output power depends on the degree of chilling the air intake to the compressor (a 12 - 22 K decrease is achieved). For this case study, maximum power gain ratio (PGR) is 15.46% (average of 12.25%), at an insignificant decrease in thermal efficiency. The second law analysis show that the exergetic power gain ratio drops to an average 8.5%. The cost of adding the air cooling system is also investigated and a cost function is derived that incorporates time-dependent meteorological data, operation characteristics of the GT and the air intake cooling system and other relevant parameters such as interest rate, lifetime, and operation and maintenance costs. The profit of adding the air cooling system is calculated for different electricity tariff. 展开更多
关键词 Gas Turbine EXERGY Analysis Power BOOSTING Hot Climate Air Cooling water chiller
下载PDF
From laboratory to on-site operation:Reevaluation of empirically based electric water chiller models 被引量:4
3
作者 Bin Zhang Shijun You +3 位作者 Sheng Wang Xiaoxiao Ding Chuang Wang Yan Gao 《Building Simulation》 SCIE EI CSCD 2022年第2期213-232,共20页
Chiller model is a key factor to building energy simulation and chiller performance prediction.With spread of new types of electric water chillers that have higher performance and wider operating range,new challenges ... Chiller model is a key factor to building energy simulation and chiller performance prediction.With spread of new types of electric water chillers that have higher performance and wider operating range,new challenges have been faced by building energy simulation tools and their chiller models.This work takes a new type of electric water chiller as a case study and reevaluates eight typical empirically based models for predicting the energy performance of electric water chiller to verify whether they are suitable for the new type of chiller,using both laboratory test data from chiller manufacturer and online monitoring data from on-site operation of a central cooling plant with chillers of the same type.The prediction ability of the chiller models(including model prediction accuracy and generation ability)in laboratory test and on-site operation situations are examined.The results show that the existing models can well describe the chiller performance in the laboratory test situation but perform poorly in the on-site operation situation.As the best two models in the laboratory dataset,the overall prediction errors of DOE-2 and GN model increase more than 250%and 75%respectively in the field dataset.The big discrepancy of model prediction accuracy in the two situations is mainly due to the differences of evaporator and condenser water flow rates between the laboratory and on-site operation datasets,which indicates the limitations of the empirical chiller models and implies further research in future in order to improve the suitability and reliability of chiller model. 展开更多
关键词 electric water chiller performance model model validation model prediction ability variable water flow rates
原文传递
Thermodynamic and Experimental Analysis of an Ammonia-Water Absorption Chiller 被引量:1
4
作者 Dingfeng Kong Jianhua Liu +2 位作者 Liang Zhang Hang He Zhiyun Fang 《Energy and Power Engineering》 2010年第4期298-305,共8页
A single stage ammonia-water absorption chiller with complete condensation is designed, built and tested. The apparatus is designed for a cooling capacity of 2814 W, which is obtained using electric heater as heating ... A single stage ammonia-water absorption chiller with complete condensation is designed, built and tested. The apparatus is designed for a cooling capacity of 2814 W, which is obtained using electric heater as heating source. The thermodynamic models have been derived using the First and Second Laws. Calculated results are compared with experimental data. The results show that the cooling capacity of experimental apparatus is found between 1900 and 2200 W with the actual coefficient of performance (COP) between 0.32 and 0.36. The contribution of the components to internal entropy production is analyzed. It shows that the larger irreversibility is caused by spanning the largest temperature and dissipated thermal energy by heat transfer losses at the generator and evaporator. In the experimentation, the low pressure is lower than the designed value. This is a consequence of a large capacity in the falling film absorber which performs as expected. This decreases the evaporation pressure, and the evaporating temperature could be reduced to the designed value. 展开更多
关键词 ABSORPTION chiller AMMONIA-water THERMODYNAMIC MODELING EXPERIMENTAL Performance
下载PDF
Evaluation of Performance of Thermal and Electrical Hybrid Adsorption Chiller Cycles with Mechanical Booster Pumps
5
作者 Tao Zeng Takehiro Esaki +2 位作者 Jun Li Noriyuki Kobayashi Hongyu Huang 《Journal of Materials Science and Chemical Engineering》 2017年第5期22-32,共11页
Large amounts of waste heat below 100oC from the industrial sector are re-leased into the atmosphere. It has been suggested that energy system efficiency can be increased with adsorption chillers. However, the cooling... Large amounts of waste heat below 100oC from the industrial sector are re-leased into the atmosphere. It has been suggested that energy system efficiency can be increased with adsorption chillers. However, the cooling power and coefficient of performance (COP) of conventional adsorption chillers significantly decrease with the desorption temperature. In this paper, we proposed a mechanical booster pump (MBP)-assisted adsorption chiller cycle, and evaluated its performances. In the cycle, a MBP was incorporated into a zeolite-water-type adsorption chiller for facilitating water vapor transportation between an adsorber and an evaporator/condenser. We have experimentally studied the effect of the input electrical power of MBP on the performances of adsorption chiller cycle. It has been demonstrated that the heat input achieved by using MBP at the desorption temperature of 50oC was 1.6 times higher than that of without MBP at the desorption temperature of 60oC. And the increase of pump power was found to be effective in increasing the heat input. Therefore, it was confirmed that the operation range of desorption temperature, which can be generated by using the waste heat, was extended and the cooling power was increased directly by using MBP. 展开更多
关键词 Adsorption chiller Cycle Zeolite/water PAIR MECHANICAL BOOSTER PUMP
下载PDF
Exergetic Optimization of Absorption Chiller Single Stage H2O-NH3 by Experiments Design Method
6
作者 Mohamed Izzedine Serge Adjibade Kokouvi Edem N'Tsoukpoe +2 位作者 Ababacar Thiam Christophe Awanto Dorothe Azilinon 《材料科学与工程(中英文A版)》 2017年第3期143-156,共14页
关键词 吸收式制冷机 设计方法 单级 实验 优化 运行温度 目标函数 不可逆损失
下载PDF
太阳能吸收式制冷系统及其蓄能技术研究 被引量:1
7
作者 张丽影 毕月虹 +1 位作者 李召金 刘林威 《制冷与空调》 2024年第4期12-23,32,共13页
在分析国内外现有太阳能吸收式制冷系统的基础上,从太阳能集热器、蓄能形式、辅助热源、吸收式冷水机组以及太阳能集热器与吸收式冷水机组的匹配等方面详细阐述太阳能吸收式制冷系统及其蓄能技术的发展现状,并对太阳能制冷空调系统的控... 在分析国内外现有太阳能吸收式制冷系统的基础上,从太阳能集热器、蓄能形式、辅助热源、吸收式冷水机组以及太阳能集热器与吸收式冷水机组的匹配等方面详细阐述太阳能吸收式制冷系统及其蓄能技术的发展现状,并对太阳能制冷空调系统的控制策略、优化分析及理论研究进行总结,最后指出太阳能吸收式制冷系统及其蓄能技术的发展方向。 展开更多
关键词 制冷 空调 冷水机组 吸收式 太阳能 集热器 蓄能
下载PDF
夏热冬冷地区空调冷热源配置的多目标优化
8
作者 朱晓玥 杨玲 +2 位作者 熊帝战 范钟引 刘希臣 《建筑节能(中英文)》 CAS 2024年第7期87-94,共8页
为实现“双碳”背景下清零建筑直接碳排放的目标,夏热冬冷地区建筑空调冷热源越来越多地采用空气源热泵加水冷式冷水机组的复合架构。其中,空气源热泵冬季供热,夏季与水冷式机组共同供冷。由于空气源热泵供冷能效较低,提高水冷式机组容... 为实现“双碳”背景下清零建筑直接碳排放的目标,夏热冬冷地区建筑空调冷热源越来越多地采用空气源热泵加水冷式冷水机组的复合架构。其中,空气源热泵冬季供热,夏季与水冷式机组共同供冷。由于空气源热泵供冷能效较低,提高水冷式机组容量配置,尽可能使之分担更多的冷负荷,有利于降低系统供冷能耗,但系统投资也将随之上升。因此,有必要研究复合架构下空调冷热源配置的综合优化方法。利用层次分析法,计算空调冷热源系统的节能性、环保性、经济性、节材性等不同目标维度的权重,建立空调冷热源的综合优化目标函数。设计空调冷热源配置的优化流程,并以上海某办公建筑为例进行分析。结果表明,随着水冷机组容量的增加,空调冷热源系统的全年能耗降低,耗材生产能耗、折算年费上升,而碳排放呈先降后升的规律。多目标优化方法可以更好地实现各项指标之间的平衡,为相关研究及实际项目决策提供参考。 展开更多
关键词 多目标优化 层次分析法 空气源热泵 水冷式冷水机组 夏热冬冷地区
下载PDF
GB 19577—2024《热泵和冷水机组能效限定值及能效等级》解析
9
作者 王志坤 张子祺 +2 位作者 亓新 陈宇劲 马颜 《中国标准化》 2024年第23期165-169,178,共6页
热泵和冷水机组作为获取冷、热水的装置,节能环保,得到了广泛的普及和应用。GB 19577—2015《冷水机组能效限定值及能效等级》已经执行了9年时间,随着制造工艺、新材料、新科技的应用,整体的能效水平得到了提高,为此国家市场监督管理总... 热泵和冷水机组作为获取冷、热水的装置,节能环保,得到了广泛的普及和应用。GB 19577—2015《冷水机组能效限定值及能效等级》已经执行了9年时间,随着制造工艺、新材料、新科技的应用,整体的能效水平得到了提高,为此国家市场监督管理总局、国家标准化管理委员会于2024年4月29日发布了标准GB 19577—2024《热泵和冷水机组能效限定值及能效等级》,并将于2025年2月1日正式实施,该标准代替了GB 19577—2015、GB 29540—2013、GB 30721—2014、GB 37480—2019。本文通过分析GB 19577—2024与GB 19577—2015等标准的差异,为从事热泵和冷水机组生产制造企业及检测机构和市场监管部门理解并执行标准提供了基础。 展开更多
关键词 热泵和冷水机组 能效限定值 能效等级
下载PDF
磁悬浮冷水机组冷冻出水温度DMC控制仿真研究
10
作者 雷良燕 陈洪科 《机电产品开发与创新》 2024年第3期91-94,共4页
针对磁悬浮冷水机组冷冻水出水温度控制存在时滞、外界干扰而传统PID控制效果不佳的问题,基于动态矩阵控制算法建立控制与仿真模型,通过预测冷水机组出水温度并加以校正,局部动态优化得到控制器最优控制量。仿真结果表明,动态矩阵控制... 针对磁悬浮冷水机组冷冻水出水温度控制存在时滞、外界干扰而传统PID控制效果不佳的问题,基于动态矩阵控制算法建立控制与仿真模型,通过预测冷水机组出水温度并加以校正,局部动态优化得到控制器最优控制量。仿真结果表明,动态矩阵控制算法能够实现平稳、无超调的控制,出水温度调整速度相比传统PID控制提升3倍以上,抗干扰能力也优于传统PID算法。 展开更多
关键词 磁悬浮冷水机组 出水温度 动态矩阵控制 PID
下载PDF
蒸发冷却式冷水机组热岛效应研究
11
作者 王亮添 林建锋 +2 位作者 黄国斌 唐力 徐浩 《制冷与空调》 2024年第7期11-17,共7页
蒸发冷却式冷水机组应用于实际工程时,排风气流易倒流至进风口,从而产生热岛效应,影响机组性能。在相同进风风量、进风入口温湿度的条件下,数值模拟研究蒸发冷却式冷水机组在不同排风百叶角度下的压力分布、温度分布和速度分布等流动特... 蒸发冷却式冷水机组应用于实际工程时,排风气流易倒流至进风口,从而产生热岛效应,影响机组性能。在相同进风风量、进风入口温湿度的条件下,数值模拟研究蒸发冷却式冷水机组在不同排风百叶角度下的压力分布、温度分布和速度分布等流动特性,得到排风气流组织和空间流场分布较佳状态下的排风百叶角度,并进行工程现场测试验证。结果表明:排风百叶角度不低于30°时,理论上可避免热岛效应发生;工程应用推荐排风百叶角度为45°,应对突发状况时冗余系数更高。 展开更多
关键词 蒸发冷却式冷水机组 排风百叶角度 气流组织 热岛效应 数值模拟
下载PDF
基于仿真对比的某办公建筑空调系统改造分析
12
作者 王丽文 李俊泽 +1 位作者 肖雅琴 彭鹏 《暖通空调》 2024年第6期65-69,94,共6页
对某办公建筑的老旧空调系统进行改造,比较了冷水机组与多联机2种改造方案,探讨了人员加班情况对系统选择的影响。首先,对建筑改造区域进行了负荷模拟,针对每种方案进行设备选型。然后,对2种方案供冷、供暖季的空调系统能耗进行了仿真... 对某办公建筑的老旧空调系统进行改造,比较了冷水机组与多联机2种改造方案,探讨了人员加班情况对系统选择的影响。首先,对建筑改造区域进行了负荷模拟,针对每种方案进行设备选型。然后,对2种方案供冷、供暖季的空调系统能耗进行了仿真和比对,多联机系统能耗更低,投资回收期仅4.6 a。最后,针对不同的加班模式和加班率进行了仿真分析,绘制了能耗-加班率曲线,发现多联机系统更适用于有人员加班情况出现的建筑。当独立办公室加班率为10%时,改造区域多联机系统的供冷季能耗比冷水机组系统低41.7%。 展开更多
关键词 办公建筑 空调系统改造 能耗 仿真模拟 冷水机组 多联机 加班率
下载PDF
大型商业建筑冷水机组运行调研及装机容量分析
13
作者 孙宇 《工程建设与设计》 2024年第9期49-51,共3页
通过对南北方不同区域的7个建筑案例中,冷水机组的装机容量和使用数据进行调研分析可知:北京地区,商业建筑实际运行的冷负荷指标约为90~130W/m^(2),对于南方的夏热冬暖地区,商业建筑实际运行的冷负荷指标为130~170W/m^(2)。究其原因,除... 通过对南北方不同区域的7个建筑案例中,冷水机组的装机容量和使用数据进行调研分析可知:北京地区,商业建筑实际运行的冷负荷指标约为90~130W/m^(2),对于南方的夏热冬暖地区,商业建筑实际运行的冷负荷指标为130~170W/m^(2)。究其原因,除室外干球温度南方稍高于北京外,湿球温度较高,室外空气焓值较高,潜热负荷大,因此,总负荷较大。 展开更多
关键词 暖通空调 冷水机 装机容量
下载PDF
旋风式油分离器仿真优化及试验验证
14
作者 赵华 韩朋飞 《制冷与空调》 2024年第1期6-11,29,共7页
采用流体仿真技术研究旋风式油分离器内部结构对其压降和油循环率OCR的影响,通过增大排气管管径、增加挡油环和导油管,设计一款新型油分离器,并进行试验验证。结果表明,与现有油分离器相比,在同一状态下,新型油分离器压力损失下降28%,OC... 采用流体仿真技术研究旋风式油分离器内部结构对其压降和油循环率OCR的影响,通过增大排气管管径、增加挡油环和导油管,设计一款新型油分离器,并进行试验验证。结果表明,与现有油分离器相比,在同一状态下,新型油分离器压力损失下降28%,OCR降低24%,该结构有利于改善其应用系统的能效。 展开更多
关键词 冷水机组 油分离器 OCR 仿真
下载PDF
常用冷水机组的性能特征和选型案例分析
15
作者 张勇华 胡攀 《节能》 2024年第3期17-20,共4页
根据厂家提供的变频螺杆式、定频离心式、变频离心式和磁悬浮离心式冷水机组的全负荷、变冷凝器进水温度性能系数曲线,分析各类冷水机组的节能特性,并提出其适用场所。以长沙市某综合商业体项目为例,设计3种常用的冷源配置方案,分别以... 根据厂家提供的变频螺杆式、定频离心式、变频离心式和磁悬浮离心式冷水机组的全负荷、变冷凝器进水温度性能系数曲线,分析各类冷水机组的节能特性,并提出其适用场所。以长沙市某综合商业体项目为例,设计3种常用的冷源配置方案,分别以变频螺杆式冷水机组和磁悬浮离心式冷水机组调节部分负荷,根据初投资、运行费用、投资回收期、全寿命周期运行成本和碳减排量等对比方案,提出优化建议。 展开更多
关键词 螺杆式冷水机组 离心式冷水机组 磁悬浮离心式冷水机组 性能系数 冷凝器进水温度
下载PDF
换流站阀厅空调冷水机组蒸发器泄漏原因分析与优化改进措施的研究
16
作者 张俊杰 董浩声 徐亚艳 《今日自动化》 2024年第5期90-92,共3页
换流站阀厅的稳定性关系到电网的正常运行,然而,阀厅空调冷水机组的蒸发器经常出现泄漏现象,对阀厅的运行稳定性构成威胁。文章对换流站阀厅空调冷水机组蒸发器泄漏原因进行了分析,发现蒸发器泄漏的主要原因在于制冷系统管道设计不合理... 换流站阀厅的稳定性关系到电网的正常运行,然而,阀厅空调冷水机组的蒸发器经常出现泄漏现象,对阀厅的运行稳定性构成威胁。文章对换流站阀厅空调冷水机组蒸发器泄漏原因进行了分析,发现蒸发器泄漏的主要原因在于制冷系统管道设计不合理及维护保养不到位。针对这些问题,提出了相应的优化改进措施,如优化管道设计,减少机械应力及强化设备维护保养,及时更换或修复磨损部件。实施优化改进措施后,冷水机组的稳定性明显提高,阀厅运行效率也得到了提升。 展开更多
关键词 换流站阀厅 冷水机组蒸发器 泄漏原因 设备维护保养 优化改进措施
下载PDF
离心冷水机组动态仿真与控制开发研究
17
作者 祝用华 《制冷与空调》 2024年第5期30-35,共6页
冷水机组控制系统影响机组的运行性能,利用仿真的方法对其进行设计可以加快设计效率、降低开发周期及成本。文章介绍了基于冷水机组动态仿真的智能控制器设计与仿真测试。首先在Modelica环境下基于热力学定律建立了冷水机组物理模型并... 冷水机组控制系统影响机组的运行性能,利用仿真的方法对其进行设计可以加快设计效率、降低开发周期及成本。文章介绍了基于冷水机组动态仿真的智能控制器设计与仿真测试。首先在Modelica环境下基于热力学定律建立了冷水机组物理模型并进行了模型验证和测试,再将冷水机组仿真模型与控制器模型结合形成动态-控制仿真平台,在此平台上开发并测试了智能加载PID(Proportion、Integral、Differential,结合比例、积分和微分三种环节于一体)、智能整定PID等算法,结果表明,基于仿真平台的控制设计可行,智能PID控制器能很好地降低系统超调量、消除系统震荡,使机组稳定可靠运行。 展开更多
关键词 冷水机组 控制 动态仿真 智能PID
下载PDF
水冷式冷水机组性能试验装置中变频器常见故障分析
18
作者 黄陆 周会平 +4 位作者 徐进兵 柯瑶 刘欣 苟盼 鲁琳琳 《制冷》 2024年第5期57-60,共4页
本文介绍了水冷式冷水机组性能试验装置运行原理,阐述了试验装置中变频器的主要应用情形和常见故障形式,从产品选型、安装及维护、参数设定及定期检查等方面提出了降低水冷式冷水机组性能试验装置变频器故障率的具体措施。
关键词 冷水机组 试验装置 变频器 故障分析
下载PDF
制冷与热泵产品的能效标准研究和循环热力学完善度的分析 被引量:16
19
作者 马一太 田华 +2 位作者 刘春涛 袁秋霞 刘忠彦 《制冷学报》 CAS CSCD 北大核心 2012年第6期1-6,共6页
为了建立评价冷水机组和水源热泵的EER或COP等能效指标的公共平台,提出了热力学完善度的分析方法,并计算了我国的房间空调器、冷水机组和水源热泵等制冷装置的热力学完善度的数据范围。大多水冷产品的热力学完善度在0.3至0.5之间,高效... 为了建立评价冷水机组和水源热泵的EER或COP等能效指标的公共平台,提出了热力学完善度的分析方法,并计算了我国的房间空调器、冷水机组和水源热泵等制冷装置的热力学完善度的数据范围。大多水冷产品的热力学完善度在0.3至0.5之间,高效产品可以达到0.6,但风冷产品热力学完善度在0.2左右,空气源热泵热水机等介于两者之间。热力学完善度可用于同类产品或相似产品在不同工况下的性能比较。分析可见热力学完善度表征着当前产品设计制造的综合水平,是制定相关产品能效标准的限定值、节能值及能效等级的依据。 展开更多
关键词 热工学 热力学完善度 EER COP 冷水机组 水源热泵
下载PDF
热源塔液气比优化分析与实验研究 被引量:17
20
作者 文先太 梁彩华 +2 位作者 张小松 周晓林 张跃 《东南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2011年第4期767-771,共5页
针对夏热冬冷地区对冬夏两季双高效供冷/供热空调设备的需求,提出了采用热源塔热泵达到夏季高效供冷而冬季高效供热效果的解决方法.对热源塔热泵的原理和工作过程及其与冷水机组和空气源热泵的异同点进行了分析,建立了叉流式热源塔装置... 针对夏热冬冷地区对冬夏两季双高效供冷/供热空调设备的需求,提出了采用热源塔热泵达到夏季高效供冷而冬季高效供热效果的解决方法.对热源塔热泵的原理和工作过程及其与冷水机组和空气源热泵的异同点进行了分析,建立了叉流式热源塔装置,并在不同室外空气参数情况下,以水和溶液(乙二醇水溶液)作为介质且在不同液气比时,对热源塔换热性能进行了研究.实验结果表明:调节室外空气温度从5.5℃升高到18.5℃,分别运行乙二醇水溶液和水,热源塔液气比优化值基本保持在0.25~0.4,而热源塔作为冷却塔使用时液气比优化值为1.33~1.67左右.冷却塔/热源塔的液气比优化值在冬季时小于夏季,此结果将为热源塔的设计及其应用提供实验数据支撑. 展开更多
关键词 热源塔 优化液气比 供热效率 冷水机组
下载PDF
上一页 1 2 36 下一页 到第
使用帮助 返回顶部