In this paper,it presents the results of calculation of solidification process of copper continuous cast bar by cross section size 120 mm × 70 mm with application of Pro Cast 2010 software. The estimation of moul...In this paper,it presents the results of calculation of solidification process of copper continuous cast bar by cross section size 120 mm × 70 mm with application of Pro Cast 2010 software. The estimation of mould design effect on solidification process of continuos copper cast bar is completed at various speeds of casting.Profiles of liquid metal cavities and temperature allocations in the cast bar at various casting speeds are defined.The analysis of received liquid metal cavity profiles shows that a new mold construction allows significantly decrease of the length of the liquid metal cavity during continuous copper casting at HAZELETTcasting machine and the increase of maximum casting speed from 10 to 11 m / min. Adequacy of the results of copper continuous cast bar solidification process calculation is confirmed by the experimental data.展开更多
The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit ...The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2.展开更多
The work presents a parametric analysis of the performance of a solar-driven thermoelectric system to dehumidify air and produce fresh water. The system is combined with a solar distiller humidifying ambient air to en...The work presents a parametric analysis of the performance of a solar-driven thermoelectric system to dehumidify air and produce fresh water. The system is combined with a solar distiller humidifying ambient air to enhance distillate output to meet the specified fresh water needs for a residential application. The presented system is a totally renewable energy-based system taking advantage of the clean solar energy. A model is developed to simulate the air dehumidification process using TEC (thermoelectrically cooled) channels. An optimization problem for setting system operational parameters is formulated to meet the fresh water requirement of 10 liters per day for a typical residential application in the Lebanese coastal humid climate. Using five TEC channels of length of 1.2 m and area of 0.07 - 0.05 m^2 integrated with 1.2 m^2 solar distiller is capable of meeting the water demand, where the air mass flow rate introduced to each TEC channel is optimally set at 0.0155 kg/s. The optimal electrical current input to the TEC modules from the photovoltaic solar panels varied depending on the month and is set at 2.2 A in June, 2.1 A in July and 2.0 A in August, September and October per each TEC module.展开更多
文摘In this paper,it presents the results of calculation of solidification process of copper continuous cast bar by cross section size 120 mm × 70 mm with application of Pro Cast 2010 software. The estimation of mould design effect on solidification process of continuos copper cast bar is completed at various speeds of casting.Profiles of liquid metal cavities and temperature allocations in the cast bar at various casting speeds are defined.The analysis of received liquid metal cavity profiles shows that a new mold construction allows significantly decrease of the length of the liquid metal cavity during continuous copper casting at HAZELETTcasting machine and the increase of maximum casting speed from 10 to 11 m / min. Adequacy of the results of copper continuous cast bar solidification process calculation is confirmed by the experimental data.
文摘The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2.
文摘The work presents a parametric analysis of the performance of a solar-driven thermoelectric system to dehumidify air and produce fresh water. The system is combined with a solar distiller humidifying ambient air to enhance distillate output to meet the specified fresh water needs for a residential application. The presented system is a totally renewable energy-based system taking advantage of the clean solar energy. A model is developed to simulate the air dehumidification process using TEC (thermoelectrically cooled) channels. An optimization problem for setting system operational parameters is formulated to meet the fresh water requirement of 10 liters per day for a typical residential application in the Lebanese coastal humid climate. Using five TEC channels of length of 1.2 m and area of 0.07 - 0.05 m^2 integrated with 1.2 m^2 solar distiller is capable of meeting the water demand, where the air mass flow rate introduced to each TEC channel is optimally set at 0.0155 kg/s. The optimal electrical current input to the TEC modules from the photovoltaic solar panels varied depending on the month and is set at 2.2 A in June, 2.1 A in July and 2.0 A in August, September and October per each TEC module.