The heat transfer coefficient is very low at bulk temperatures higher than the pseudo-critical point,because the supercritical pressure leads to a vapor-like fluid.In this paper,the heat transfer downstream an obstacl...The heat transfer coefficient is very low at bulk temperatures higher than the pseudo-critical point,because the supercritical pressure leads to a vapor-like fluid.In this paper,the heat transfer downstream an obstacle-bearing vertical tube is simulated by the CFD code of Fluent 6.1,using an adaptive grid in the supercritical condition.The reliable results are obtained by the RNG k-ε model using the enhanced wall treatment.The blockage ratio and local temperature of obstacle affect greatly the heat transfer enhancement,and the resultant influence region and decay trend are compared with the existing equations.展开更多
We conducted a transient experimental investigation of steam–water direct contact condensation in the absence of noncondensible gas in a laboratory-scale column with the inner diameter of 325 mm and the height of 104...We conducted a transient experimental investigation of steam–water direct contact condensation in the absence of noncondensible gas in a laboratory-scale column with the inner diameter of 325 mm and the height of 1045 mm. We applied a new analysis method for the steam state equation to analyze the molar quantity change in steam over the course of the experiment and determined the transient steam variation. We also investigated the influence of flow rates and temperatures ofcooling water on the efficiency ofsteam condensation. Our experimental results show that appropriate increasing of the cooling water flow rate can significantly accelerate the steam condensation. We achieved a rapid increase in the total volumetric heat transfer coefficient by increasing the flow rate of cooling water, which indicated a higher thermal convection between the steam and the cooling water with higher flow rates. We found that the temperature ofcooling water did not play an important role on steam condensation. This method was confirmed to be effective for rapid recovering ofsteam.展开更多
Coupled transfer of soil water and heat in closed columns of homogeneous red soil was studied under laboratory conditions. A coupled model was constructed using soil physical theory, empirical equations and experiment...Coupled transfer of soil water and heat in closed columns of homogeneous red soil was studied under laboratory conditions. A coupled model was constructed using soil physical theory, empirical equations and experimental data to predict the coupled transfer. The results show that transport of soil water was affected by temperature gradient, and the largest net water transport was found in the soil column with initial water content of 0.148 m3 m-3. At the same time, temperature changes with the transport of soil water was in a nonlinear shape as heat parameters were function of water content, and the changes of temperature were positively correlated with the net amount of water transported. Numerical modelling results show that the predicted values of temperature distribution were close to the observed values, while the predicted values of water content exhibited limited deviation at both ends of the soil column due to the slight temperature changes at both ends. It was indicated that the model proposed here was applicable.展开更多
Boiling of water/triethyleneglycol(TEG)binary solution has a wide-ranging application in the gas processing engineering.Design,operation and optimization of the involved boilers require accurate prediction of boiling ...Boiling of water/triethyleneglycol(TEG)binary solution has a wide-ranging application in the gas processing engineering.Design,operation and optimization of the involved boilers require accurate prediction of boiling heat transfer coefficient between surface and solution.In this investigation,nucleate pool boiling heat transfer coefficient has been experimentally measured on a horizontal rod heater in water/TEG binary solutions in a wide range of concentrations and heat fluxes under ambient condition.The present experimental data are correlated using major existing correlations.In addition a correlation is presented for prediction of pool boiling heat transfer for the system in which the vapour pressure of one component is negligible.This model is based on the mass transfer rate equation for prediction of the concentration at the bubble vapor/liquid interface.Based on this prediction,the temperature of the interface and accordingly,the boiling heat transfer coefficient could be straightforwardly calculated from the known concentration at the interface.It is shown that this simple model has sufficient accuracy and is acceptable below the medium concentrations of TEG when the vapor equilibrium concentration of TEG is almost zero.The presented model excludes any tuning parameter and requires very few physical properties to apply.展开更多
In the direct fired furnace of a continuous annealing line, seal rolls are susceptible to deformation that leads to surface defects of steel strips. According to failure analysis, the reasons include improper structur...In the direct fired furnace of a continuous annealing line, seal rolls are susceptible to deformation that leads to surface defects of steel strips. According to failure analysis, the reasons include improper structural design and heat imbalance. An improved design has been proposed to reduce stress concentration and thermal radiation. A heat transfer model has been employed to determine the proper water flow rate for roll cooling. Industrial application proves that seal rolls with the new design has less deformation and longer service life.展开更多
For predicting and controlling the melted depth of bottomelectrode during the process of steelmaking, the water-cooling steel-stick electrode is taken as an example, to analyze the process ofheat transfer, then 3D mat...For predicting and controlling the melted depth of bottomelectrode during the process of steelmaking, the water-cooling steel-stick electrode is taken as an example, to analyze the process ofheat transfer, then 3D mathematical model by control capacity methodis built. At the same time, the measurement on the melted depth ofbottom electrode is conducted which verified the correctness of thebuilt mathematical model. On the base of verification, all kinds ofkey parameters are calculated through the application and a series ofresults are simulated. Finally, the optimum parameters are found andthe service life of bottom electrode is prolonged.展开更多
Based on the analysis of the principles of heat and mass transfer from the liquid bulk to bubble surface during nucleation, a new estimation method to predict the heat transfer of the nucleate pool boiling in binary m...Based on the analysis of the principles of heat and mass transfer from the liquid bulk to bubble surface during nucleation, a new estimation method to predict the heat transfer of the nucleate pool boiling in binary mixtures is proposed in this paper by using t he heat and mass transfer analogy (Colburn analogy) at the bubble surface transfer layers. With the use of Thome's eaacept of boiling range, an approximate method is derived to vealise the calculation. The peedictbd results by this method are in good agreement with the experimental data from different sources.展开更多
In order to realize safe and stable operation of a water-cooled W/Cu divertor under high heating condition,the exact knowledge of its subcooled boiling heat transfer characteristics under different design parameters i...In order to realize safe and stable operation of a water-cooled W/Cu divertor under high heating condition,the exact knowledge of its subcooled boiling heat transfer characteristics under different design parameters is crucial.In this paper,subcooled boiling heat transfer in a water-cooled W/Cu divertor was numerically investigated based on computational fluid dynamic(CFD).The boiling heat transfer was simulated based on the Euler homogeneous phase model,and local differences of liquid physical properties were considered under one-sided high heating conditions.The calculated wall temperature was in good agreement with experimental results,with the maximum error of 5%only.On this basis,the void fraction distribution,flow field and heat transfer coefficient(HTC)distribution were obtained.The effects of heat flux,inlet velocity and inlet temperature on temperature distribution and pressure drop of a water-cooled W/Cu divertor were also investigated.These results provide a valuable reference for the thermal-hydraulic design of a water-cooled W/Cu divertor.展开更多
The processes of heat and humidity transfer between air and water are what to be studied mainly in the paper, we put forward some main factors which influence the processes of heat and humidity transfer in the air was...The processes of heat and humidity transfer between air and water are what to be studied mainly in the paper, we put forward some main factors which influence the processes of heat and humidity transfer in the air washer. We come to the conclusion that we can change these main factors to achieve different heat and humidity transfer processes and decide processes of heat and humidity transfer of air and water with the initial temperature of spraying water in the air washer. All these results can make things convenient for the air conditioning management.展开更多
Studies on coupled transfer of soil moisture and heat have been widely carried out for decades. However, little work has been done on red soils, widespread in southern China. The simultaneous transfer of soil moisture...Studies on coupled transfer of soil moisture and heat have been widely carried out for decades. However, little work has been done on red soils, widespread in southern China. The simultaneous transfer of soil moisture and heat depends on soil physical properties and the climate conditions. Red soil is heavy clay and high content of free iron and aluminum oxide. The climate conditions are characterized by the clear four seasons and the serious seasonal drought. The great annual and diurnal air temperature differences result in significant fluctuation in soil temperature in top layer. The closed and evaporating columns experiments with red soil were conducted to simulate the coupled transfer of soil water and heat under the overlaying and opening fields’ conditions, and to analyze the effects of soil temperature gradient on the water transfer and the effects of initial soil water contents on the transfer of soil water and heat. The closed and evaporating columns were designed similarly with about 18 °C temperatures differences between the top and bottom boundary, except of the upper end closed or exposed to the air, respectively. Results showed that in the closed column, water moved towards the cold end driven by temperature gradient, while the transported water decreased with the increasing initial soil water content until the initial soil water content reached to field capacity equivalent, when almost no changes for the soil moisture profile. In the evaporating column, the net transport of soil water was simultaneously driven by evaporation and temperature gradients, and the drier soil was more influenced by temperature gradient than by evapo- ration. In drier soil, it took a longer time for the temperature to reach equilibrium, because of more net amount of transported water.展开更多
Natural gas is transported from producing regions to consumption regions by using transmission pipelines at high pressures. At consumption regions, the pressure of natural gas is reduced in city gate stations(CGSs). B...Natural gas is transported from producing regions to consumption regions by using transmission pipelines at high pressures. At consumption regions, the pressure of natural gas is reduced in city gate stations(CGSs). Before the pressure reduction process, the temperature of natural gas is increased usually by using a water bath heater,which burns natural gas as fuel, to protect against freezing of natural gas. These types of heat exchangers have a low efficiency and consume a lot of fuel to generate the required heat. In the current study, the twisted configuration of the heating coil is proposed and investigated to enhance the heat transfer through a water bath heater with a nominal capacity of 1000 m^3·h^-1. Firstly, the implementation procedure is validated with data collected from the CGS of Qaleh-Jiq(located in Golestan province of Iran). A very good agreement is achieved between the obtained results and the real data. Then, three different twist ratios are considered to examine the twisting effects. The proposed technique is evaluated in the terms of velocity, temperature, and pressure variations, and the results are compared with the conventional case, i.e. straight configuration. It is found that both the heat transfer rate and the pressure drop augment as the twist ratio is raised. Finally, it is concluded that the twisted tubes can reduce the length of the gas coil by about 12.5% for the model with low twist ratio, 18.75% for the model with medium twist ratio, and 25% for the model with high twist ratio as compared to the straight configuration.展开更多
Simulation models of heat and water transport have not been rigorously tested for the red soils of southern China. Based on the theory of nonisothermal water-heat coupled transfer, a simulation model, programmed in Vi...Simulation models of heat and water transport have not been rigorously tested for the red soils of southern China. Based on the theory of nonisothermal water-heat coupled transfer, a simulation model, programmed in Visual Basic 6.0, was developed to predict the coupled transfer of water and heat in hilly red soil. A series of soil column experiments for soil water and heat transfer, including soil columns with closed and evaporating top ends, were used to test the simulation model. Results showed that in the closed columns, the temporal and spatial distribution of moisture and heat could be very well predicted by the model, while in the evaporating columns, the simulated soil water contents were somewhat different from the observed ones. In the heat flow equation by Taylor and Lary (1964), the effect of soil water evaporation on the heat flow is not involved, which may be the main reason for the differences between simulated and observed results. The predicted temperatures were not in agreement with the observed one with thermal conductivities calculated by de Vries and Wierenga equations, so that it is suggested that Kh, soil heat conductivity, be multiplied by 8.0 for the first 6.5 h and by 1.2 later on. Sensitivity analysis of soil water and heat coefficients showed that the saturated hydraulic conductivity, KS, and the water diffusivity, D(θ), had great effects on soil water transport; the variation of soil porosity led to the difference of soil thermal properties, and accordingly changed temperature redistribution, which would affect water redistribution.展开更多
It is important to select suitable parameters of a submerged entry nozzle (SEN) for optimizing the flow and temperature patterns in a mold. The effect of SEN design on the mould level stability, meniscus steel flow ...It is important to select suitable parameters of a submerged entry nozzle (SEN) for optimizing the flow and temperature patterns in a mold. The effect of SEN design on the mould level stability, meniscus steel flow velocity, and heat transfer of the mold of a medium thin slab caster was studied by means of 1:1 water modeling and industrial testing. The advantages of a 2-port SEN compared with a 3-port SEN are the following: more optimal flow patterns with a lower mold level fluctuation and a lower meniscus steel flow velocity; proper powder consumption without slag bears due to a reasonable liquid powder thickness. The argon flow rate can be reduced and the mold average heat flux and temperature near the edges of the copper plate are reduced. At a casting speed of 2.5 m·min^-1, the mold level fluctuation lies within +5 mm. In addition, soft cooling of the steel shell in the mold is realized, which is suitable for casting crack susceptible steel grades.展开更多
Research activities involving heat transfer at supercritical pressures have attracted attention in recent years because of possibility of increase in thermal output of heat transfer and industrial equipment. Because o...Research activities involving heat transfer at supercritical pressures have attracted attention in recent years because of possibility of increase in thermal output of heat transfer and industrial equipment. Because of high pressure and temperature conditions associated with heat transfer at supercritical pressures, only few experimental heat transfer studies are being carried out at supercritical conditions. The use of numerical tools for heat transfer and other related studies at supercritical pressures is increasing because of the high-pressure-temperature limitation of experimental studies at supercritical conditions. Heat transfer correlations implemented in these numerical tools are used to obtain numerical heat transfer data to complement experimental heat transfer data provided through experimental studies. In order to further broaden the understanding of fluid flow and heat transfer, this review examines the performance of heat transfer correlations adopted at supercritical pressures. It is found from the review that most of the correlations could predict heat transfer quite well in the low enthalpy region and few of the correlations could predict heat transfer in the high enthalpy region near critical and pseudo-critical conditions (heat transfer deteriorated conditions). However, no single heat transfer correlation is able to accurately predict all the experimental results presented in this work.展开更多
基金Supported by Xi'an Jiaotong Unversity(XJTU)Atomic Energy of Canada Limited(AECL)
文摘The heat transfer coefficient is very low at bulk temperatures higher than the pseudo-critical point,because the supercritical pressure leads to a vapor-like fluid.In this paper,the heat transfer downstream an obstacle-bearing vertical tube is simulated by the CFD code of Fluent 6.1,using an adaptive grid in the supercritical condition.The reliable results are obtained by the RNG k-ε model using the enhanced wall treatment.The blockage ratio and local temperature of obstacle affect greatly the heat transfer enhancement,and the resultant influence region and decay trend are compared with the existing equations.
文摘We conducted a transient experimental investigation of steam–water direct contact condensation in the absence of noncondensible gas in a laboratory-scale column with the inner diameter of 325 mm and the height of 1045 mm. We applied a new analysis method for the steam state equation to analyze the molar quantity change in steam over the course of the experiment and determined the transient steam variation. We also investigated the influence of flow rates and temperatures ofcooling water on the efficiency ofsteam condensation. Our experimental results show that appropriate increasing of the cooling water flow rate can significantly accelerate the steam condensation. We achieved a rapid increase in the total volumetric heat transfer coefficient by increasing the flow rate of cooling water, which indicated a higher thermal convection between the steam and the cooling water with higher flow rates. We found that the temperature ofcooling water did not play an important role on steam condensation. This method was confirmed to be effective for rapid recovering ofsteam.
基金Project (No. 49671050) supported by the National Natural Science Foundation of China.
文摘Coupled transfer of soil water and heat in closed columns of homogeneous red soil was studied under laboratory conditions. A coupled model was constructed using soil physical theory, empirical equations and experimental data to predict the coupled transfer. The results show that transport of soil water was affected by temperature gradient, and the largest net water transport was found in the soil column with initial water content of 0.148 m3 m-3. At the same time, temperature changes with the transport of soil water was in a nonlinear shape as heat parameters were function of water content, and the changes of temperature were positively correlated with the net amount of water transported. Numerical modelling results show that the predicted values of temperature distribution were close to the observed values, while the predicted values of water content exhibited limited deviation at both ends of the soil column due to the slight temperature changes at both ends. It was indicated that the model proposed here was applicable.
文摘Boiling of water/triethyleneglycol(TEG)binary solution has a wide-ranging application in the gas processing engineering.Design,operation and optimization of the involved boilers require accurate prediction of boiling heat transfer coefficient between surface and solution.In this investigation,nucleate pool boiling heat transfer coefficient has been experimentally measured on a horizontal rod heater in water/TEG binary solutions in a wide range of concentrations and heat fluxes under ambient condition.The present experimental data are correlated using major existing correlations.In addition a correlation is presented for prediction of pool boiling heat transfer for the system in which the vapour pressure of one component is negligible.This model is based on the mass transfer rate equation for prediction of the concentration at the bubble vapor/liquid interface.Based on this prediction,the temperature of the interface and accordingly,the boiling heat transfer coefficient could be straightforwardly calculated from the known concentration at the interface.It is shown that this simple model has sufficient accuracy and is acceptable below the medium concentrations of TEG when the vapor equilibrium concentration of TEG is almost zero.The presented model excludes any tuning parameter and requires very few physical properties to apply.
文摘In the direct fired furnace of a continuous annealing line, seal rolls are susceptible to deformation that leads to surface defects of steel strips. According to failure analysis, the reasons include improper structural design and heat imbalance. An improved design has been proposed to reduce stress concentration and thermal radiation. A heat transfer model has been employed to determine the proper water flow rate for roll cooling. Industrial application proves that seal rolls with the new design has less deformation and longer service life.
文摘For predicting and controlling the melted depth of bottomelectrode during the process of steelmaking, the water-cooling steel-stick electrode is taken as an example, to analyze the process ofheat transfer, then 3D mathematical model by control capacity methodis built. At the same time, the measurement on the melted depth ofbottom electrode is conducted which verified the correctness of thebuilt mathematical model. On the base of verification, all kinds ofkey parameters are calculated through the application and a series ofresults are simulated. Finally, the optimum parameters are found andthe service life of bottom electrode is prolonged.
文摘Based on the analysis of the principles of heat and mass transfer from the liquid bulk to bubble surface during nucleation, a new estimation method to predict the heat transfer of the nucleate pool boiling in binary mixtures is proposed in this paper by using t he heat and mass transfer analogy (Colburn analogy) at the bubble surface transfer layers. With the use of Thome's eaacept of boiling range, an approximate method is derived to vealise the calculation. The peedictbd results by this method are in good agreement with the experimental data from different sources.
基金supported by the National Magnetic Confinement Fusion Science Program of China(No.2010GB104005)Funding of Jiangsu Innovation Program for Graduate Education(CXLX12.0170)the Fundamental Research Funds for the Central Universities of China
文摘In order to realize safe and stable operation of a water-cooled W/Cu divertor under high heating condition,the exact knowledge of its subcooled boiling heat transfer characteristics under different design parameters is crucial.In this paper,subcooled boiling heat transfer in a water-cooled W/Cu divertor was numerically investigated based on computational fluid dynamic(CFD).The boiling heat transfer was simulated based on the Euler homogeneous phase model,and local differences of liquid physical properties were considered under one-sided high heating conditions.The calculated wall temperature was in good agreement with experimental results,with the maximum error of 5%only.On this basis,the void fraction distribution,flow field and heat transfer coefficient(HTC)distribution were obtained.The effects of heat flux,inlet velocity and inlet temperature on temperature distribution and pressure drop of a water-cooled W/Cu divertor were also investigated.These results provide a valuable reference for the thermal-hydraulic design of a water-cooled W/Cu divertor.
文摘The processes of heat and humidity transfer between air and water are what to be studied mainly in the paper, we put forward some main factors which influence the processes of heat and humidity transfer in the air washer. We come to the conclusion that we can change these main factors to achieve different heat and humidity transfer processes and decide processes of heat and humidity transfer of air and water with the initial temperature of spraying water in the air washer. All these results can make things convenient for the air conditioning management.
基金Project supported by the National Natural Science Foundation ofChina (No. 40171047) and the Doctoral Foundation of NationalEducation Ministry China
文摘Studies on coupled transfer of soil moisture and heat have been widely carried out for decades. However, little work has been done on red soils, widespread in southern China. The simultaneous transfer of soil moisture and heat depends on soil physical properties and the climate conditions. Red soil is heavy clay and high content of free iron and aluminum oxide. The climate conditions are characterized by the clear four seasons and the serious seasonal drought. The great annual and diurnal air temperature differences result in significant fluctuation in soil temperature in top layer. The closed and evaporating columns experiments with red soil were conducted to simulate the coupled transfer of soil water and heat under the overlaying and opening fields’ conditions, and to analyze the effects of soil temperature gradient on the water transfer and the effects of initial soil water contents on the transfer of soil water and heat. The closed and evaporating columns were designed similarly with about 18 °C temperatures differences between the top and bottom boundary, except of the upper end closed or exposed to the air, respectively. Results showed that in the closed column, water moved towards the cold end driven by temperature gradient, while the transported water decreased with the increasing initial soil water content until the initial soil water content reached to field capacity equivalent, when almost no changes for the soil moisture profile. In the evaporating column, the net transport of soil water was simultaneously driven by evaporation and temperature gradients, and the drier soil was more influenced by temperature gradient than by evapo- ration. In drier soil, it took a longer time for the temperature to reach equilibrium, because of more net amount of transported water.
基金Islamic Azad University(IAU)Shahrood Branch,Shahrood,IranGolestan Province Gas Company,Gorgan,Iran for their sponsorships.
文摘Natural gas is transported from producing regions to consumption regions by using transmission pipelines at high pressures. At consumption regions, the pressure of natural gas is reduced in city gate stations(CGSs). Before the pressure reduction process, the temperature of natural gas is increased usually by using a water bath heater,which burns natural gas as fuel, to protect against freezing of natural gas. These types of heat exchangers have a low efficiency and consume a lot of fuel to generate the required heat. In the current study, the twisted configuration of the heating coil is proposed and investigated to enhance the heat transfer through a water bath heater with a nominal capacity of 1000 m^3·h^-1. Firstly, the implementation procedure is validated with data collected from the CGS of Qaleh-Jiq(located in Golestan province of Iran). A very good agreement is achieved between the obtained results and the real data. Then, three different twist ratios are considered to examine the twisting effects. The proposed technique is evaluated in the terms of velocity, temperature, and pressure variations, and the results are compared with the conventional case, i.e. straight configuration. It is found that both the heat transfer rate and the pressure drop augment as the twist ratio is raised. Finally, it is concluded that the twisted tubes can reduce the length of the gas coil by about 12.5% for the model with low twist ratio, 18.75% for the model with medium twist ratio, and 25% for the model with high twist ratio as compared to the straight configuration.
基金Project supported by the National Natural Science Foundation ofChina (No. 40171047) and the Doctoral Foundation of NationalEducation Ministry China
文摘Simulation models of heat and water transport have not been rigorously tested for the red soils of southern China. Based on the theory of nonisothermal water-heat coupled transfer, a simulation model, programmed in Visual Basic 6.0, was developed to predict the coupled transfer of water and heat in hilly red soil. A series of soil column experiments for soil water and heat transfer, including soil columns with closed and evaporating top ends, were used to test the simulation model. Results showed that in the closed columns, the temporal and spatial distribution of moisture and heat could be very well predicted by the model, while in the evaporating columns, the simulated soil water contents were somewhat different from the observed ones. In the heat flow equation by Taylor and Lary (1964), the effect of soil water evaporation on the heat flow is not involved, which may be the main reason for the differences between simulated and observed results. The predicted temperatures were not in agreement with the observed one with thermal conductivities calculated by de Vries and Wierenga equations, so that it is suggested that Kh, soil heat conductivity, be multiplied by 8.0 for the first 6.5 h and by 1.2 later on. Sensitivity analysis of soil water and heat coefficients showed that the saturated hydraulic conductivity, KS, and the water diffusivity, D(θ), had great effects on soil water transport; the variation of soil porosity led to the difference of soil thermal properties, and accordingly changed temperature redistribution, which would affect water redistribution.
文摘It is important to select suitable parameters of a submerged entry nozzle (SEN) for optimizing the flow and temperature patterns in a mold. The effect of SEN design on the mould level stability, meniscus steel flow velocity, and heat transfer of the mold of a medium thin slab caster was studied by means of 1:1 water modeling and industrial testing. The advantages of a 2-port SEN compared with a 3-port SEN are the following: more optimal flow patterns with a lower mold level fluctuation and a lower meniscus steel flow velocity; proper powder consumption without slag bears due to a reasonable liquid powder thickness. The argon flow rate can be reduced and the mold average heat flux and temperature near the edges of the copper plate are reduced. At a casting speed of 2.5 m·min^-1, the mold level fluctuation lies within +5 mm. In addition, soft cooling of the steel shell in the mold is realized, which is suitable for casting crack susceptible steel grades.
文摘Research activities involving heat transfer at supercritical pressures have attracted attention in recent years because of possibility of increase in thermal output of heat transfer and industrial equipment. Because of high pressure and temperature conditions associated with heat transfer at supercritical pressures, only few experimental heat transfer studies are being carried out at supercritical conditions. The use of numerical tools for heat transfer and other related studies at supercritical pressures is increasing because of the high-pressure-temperature limitation of experimental studies at supercritical conditions. Heat transfer correlations implemented in these numerical tools are used to obtain numerical heat transfer data to complement experimental heat transfer data provided through experimental studies. In order to further broaden the understanding of fluid flow and heat transfer, this review examines the performance of heat transfer correlations adopted at supercritical pressures. It is found from the review that most of the correlations could predict heat transfer quite well in the low enthalpy region and few of the correlations could predict heat transfer in the high enthalpy region near critical and pseudo-critical conditions (heat transfer deteriorated conditions). However, no single heat transfer correlation is able to accurately predict all the experimental results presented in this work.