In this paper, a combination of field measurement, theoretical analysis and numerical simulation were used to study the main control factors of coal mine water inrush in a main aquifer coal seam and its control scheme...In this paper, a combination of field measurement, theoretical analysis and numerical simulation were used to study the main control factors of coal mine water inrush in a main aquifer coal seam and its control scheme. On the basis of revealing and analyzing the coal seam as the main aquifer in western coal mine of Xiao Jihan coal mine, the simulation software of PHASE-2D was applied to analyze the water inflow under different influencing factors. The results showed that water inflow increases logarithmically with the coal seam thickness, increases as a power function with the permeability coefficient of the coal seam, and increases linearly with the coal seam burial depth and the head pressure; The evaluation model for the factors of coal seam water inrush was gained by using nonlinear regression analysis with SPSS. The mine water inrush risk evaluation partition within the scope of the mining field was obtained,through the engineering application in Xiao Jihan coal mine. To ensure the safe and efficient production of the mine, we studied the coal mine water disaster prevention and control measures of a main aquifer coal seam in aspects of roadway driving and coal seam mining.展开更多
In a karst tunnel, fissures or cracks that are filled with weathered materials are a type of potential water outlet as they are easily triggered and converted into groundwater outlets under the influence of high groun...In a karst tunnel, fissures or cracks that are filled with weathered materials are a type of potential water outlet as they are easily triggered and converted into groundwater outlets under the influence of high groundwater pressure. A terrible water inrush caused by potential water outlets can seriously hinder the project construction. Potential water outlets and water sources that surrounding the tunnel must be detected before water inflow can be treated. This paper provides a successful case of the detection and treatment of water inflow in a karst tunnel and proposes a potential water outlet detection(PWOD) method in which heavy rainfall(>50 mm/d) is considered a trigger for a potential water outlet. The Daba tunnel located in Hunan province, China, has been constructed in a karst stratum where the rock mass has been weathered intensely by the influence of two faults. Heavy rain triggered some potential water outlets, causing a serious water inrush. The PWOD method was applied in this project for the treatment of water inflow, and six potential water outlets in total were identified through three heavy rains. Meanwhile, a geophysical prospecting technique was also used to detect water sources. The connections between water outlets and water sources were identified with a 3-D graphic that included all of them. According to the distribution of water outlets and water sources, the detection area was divided into three sections and separately treated by curtain grouting.展开更多
Based on the stress field distribution rule of the mining floor under abutment pressure, we have established a simplified mechanical model, which contains multiple factors relating to activation and evolution of insid...Based on the stress field distribution rule of the mining floor under abutment pressure, we have established a simplified mechanical model, which contains multiple factors relating to activation and evolution of insidious water-conductive faults. The influence of normal and shear stresses on fault activation and effective shear stress distribution in the fault plane was acquired under mining conditions.Using fracture mechanics theory to calculate the stress intensity factor of an insidious fault front, we have derived the criterion for main fault activation. Results indicate that during the whole working face advance, transpressions are exerted on fault planes twice successively in opposite directions. In most cases, the second transpression is more likely to lead to fault activation. Activation is influenced by many factors, predominant among which are: burial depth of the insidious fault, friction angle of the fault plane, face advance direction and pore water pressure. Steep fault planes are more easily activated to induce a sustained water inrush in the face.展开更多
基金provided by the National Key Basic Research Program of China (No. 2013CB227905)the Science Fund for Creative Research Groups of the National Natural Science Foundation of China (No. 51421003)the Jiangsu Province Ordinary University Graduate Student Scientific Research Innovation Projects (No. KYLX16_0564)
文摘In this paper, a combination of field measurement, theoretical analysis and numerical simulation were used to study the main control factors of coal mine water inrush in a main aquifer coal seam and its control scheme. On the basis of revealing and analyzing the coal seam as the main aquifer in western coal mine of Xiao Jihan coal mine, the simulation software of PHASE-2D was applied to analyze the water inflow under different influencing factors. The results showed that water inflow increases logarithmically with the coal seam thickness, increases as a power function with the permeability coefficient of the coal seam, and increases linearly with the coal seam burial depth and the head pressure; The evaluation model for the factors of coal seam water inrush was gained by using nonlinear regression analysis with SPSS. The mine water inrush risk evaluation partition within the scope of the mining field was obtained,through the engineering application in Xiao Jihan coal mine. To ensure the safe and efficient production of the mine, we studied the coal mine water disaster prevention and control measures of a main aquifer coal seam in aspects of roadway driving and coal seam mining.
基金supported by the National Key Research and Development Project (Grant No.2016YFC0801604)Natural Science Foundation of Shandong Province (Grant No.ZR2017MEE070)
文摘In a karst tunnel, fissures or cracks that are filled with weathered materials are a type of potential water outlet as they are easily triggered and converted into groundwater outlets under the influence of high groundwater pressure. A terrible water inrush caused by potential water outlets can seriously hinder the project construction. Potential water outlets and water sources that surrounding the tunnel must be detected before water inflow can be treated. This paper provides a successful case of the detection and treatment of water inflow in a karst tunnel and proposes a potential water outlet detection(PWOD) method in which heavy rainfall(>50 mm/d) is considered a trigger for a potential water outlet. The Daba tunnel located in Hunan province, China, has been constructed in a karst stratum where the rock mass has been weathered intensely by the influence of two faults. Heavy rain triggered some potential water outlets, causing a serious water inrush. The PWOD method was applied in this project for the treatment of water inflow, and six potential water outlets in total were identified through three heavy rains. Meanwhile, a geophysical prospecting technique was also used to detect water sources. The connections between water outlets and water sources were identified with a 3-D graphic that included all of them. According to the distribution of water outlets and water sources, the detection area was divided into three sections and separately treated by curtain grouting.
基金funded by the Major Basic Research and Development Program of China(No.2014CB046905)the Ph.D.Programs Foundation of Ministry of Education of China(No.20130095110018)
文摘Based on the stress field distribution rule of the mining floor under abutment pressure, we have established a simplified mechanical model, which contains multiple factors relating to activation and evolution of insidious water-conductive faults. The influence of normal and shear stresses on fault activation and effective shear stress distribution in the fault plane was acquired under mining conditions.Using fracture mechanics theory to calculate the stress intensity factor of an insidious fault front, we have derived the criterion for main fault activation. Results indicate that during the whole working face advance, transpressions are exerted on fault planes twice successively in opposite directions. In most cases, the second transpression is more likely to lead to fault activation. Activation is influenced by many factors, predominant among which are: burial depth of the insidious fault, friction angle of the fault plane, face advance direction and pore water pressure. Steep fault planes are more easily activated to induce a sustained water inrush in the face.