As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scal...As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scale reinforced concrete(RC)frame structure.Different material pipes and different methods for penetrating the reinforced concrete floors are combined to evaluate the difference in seismic performance.Floor response spectra and pipe acceleration amplification factors based on test data are discussed and compared with code provisions.A seismic fragility study of displacement demand is conducted based on numerical simulation.The acceleration response and displacement response of different combinations are compared.The results show that the combination of different pipe materials and different passing-through methods can cause obvious differences in the seismic response of indoor riser pipes.展开更多
Mathematical physics equations are often utilized to describe physical phenomena in various fields of science and engineering.One such equation is the Fourier equation,which is a commonly used and effective method for...Mathematical physics equations are often utilized to describe physical phenomena in various fields of science and engineering.One such equation is the Fourier equation,which is a commonly used and effective method for evaluating the effectiveness of temperature control measures for mass concrete.One important measure for temperature control in mass concrete is the use of cooling water pipes.However,the mismatch of grids between large-scale concrete models and small-scale cooling pipe models can result in a significant waste of calculation time when using the finite element method.Moreover,the temperature of the water in the cooling pipe needs to be iteratively calculated during the thermal transfer process.The substructure method can effectively solve this problem,and it has been validated by scholars.The Abaqus/Python secondary development technology provides engineers with enough flexibility to combine the substructure method with an iteration algorithm,which enables the creation of a parametric modeling calculation for cooling water pipes.This paper proposes such a method,which involves iterating the water pipe boundary and establishing the water pipe unit substructure to numerically simulate the concrete temperature field that contains a cooling water pipe.To verify the feasibility and accuracy of the proposed method,two classic numerical examples were analyzed.The results showed that this method has good applicability in cooling pipe calculations.When the value of the iteration parameterαis 0.4,the boundary temperature of the cooling water pipes can meet the accuracy requirements after 4∼5 iterations,effectively improving the computational efficiency.Overall,this approach provides a useful tool for engineers to analyze the temperature control measures accurately and efficiently for mass concrete,such as cooling water pipes,using Abaqus/Python secondary development.展开更多
This study is the result of ongoing research for a European Union 7th Framework Program Project regarding energy converters for very low heads, and aims to analyze optimization of new cost-effective hydraulic turbine ...This study is the result of ongoing research for a European Union 7th Framework Program Project regarding energy converters for very low heads, and aims to analyze optimization of new cost-effective hydraulic turbine designs for possible implementation in water supply systems (WSSs) or in other pressurized water pipe infrastructures, such as irrigation, wastewater, or drainage systems. A new methodology is presented based on a theoretical, technical and economic analysis. Viability studies focused on small power values for different pipe systems were investigated. Detailed analyses of alternative typical volumetric energy converters were conducted on the basis of mathematical and physical fundamentals as well as computational fluid dynamics (CFD) associated with the interaction between the flow conditions and the system operation. Important constraints (e.g., size, stability, efficiency, and continuous steady flow conditions) can be identified and a search for alternative rotary yolumetric converters is being conducted. As promising cost-effective solutions for the coming years, adapted rotor-dynamic turbomachines and non-conventional axial propeller devices were analyzed based on the basic principles of pumps operating as turbines, as well as through an extensive comparison between simulations and experimental tests.展开更多
Solving the absent assignment problem of the shortest time limit in a weighted bipartite graph with the minimal weighted k-matching algorithm is unsuitable for situations in which large numbers of problems need to be ...Solving the absent assignment problem of the shortest time limit in a weighted bipartite graph with the minimal weighted k-matching algorithm is unsuitable for situations in which large numbers of problems need to be addressed by large numbers of parties. This paper simplifies the algorithm of searching for the even alternating path that contains a maximal element using the minimal weighted k-matching theorem and intercept graph. A program for solving the maximal efficiency assignment problem was compiled. As a case study, the program was used to solve the assignment problem of water piping repair in the case of a large number of companies and broken pipes, and the validity of the program was verified.展开更多
The article addresses the results of effective water losses prevention in public water supply systems, focusing on procedures for monitoring hidden leaks as the main part of losses and as the first step to control and...The article addresses the results of effective water losses prevention in public water supply systems, focusing on procedures for monitoring hidden leaks as the main part of losses and as the first step to control and prevent them. The described methodology has been applied based on a cross-border cooperation between twin capital cities Vienna and Bratislava in the Central Europe Region within the project deWaloP (Developing Water Loss Prevention) and adopted in Bratislava Water Company (BVS) in the Slovak Republic. The paper provides a complex of simple and easily available practices for analyses of water distribution measurements bringing essential information as to the necessity to use advanced procedures to actively reduce leakage. These practices involve minimum night flows analyses, hydrodynamic pressures analyses, pinpointing of water leakages by working with valves in the water network, the methodology of setting alarm limits for measured data, as well as use of advanced practices to obtain missing topologic data. As the water infrastructure in former socialistic countries are in bad technical condition and the lack of pertinent operational data is a significant obstacle to the application of a more sophisticated methodology based on GIS and other information systems, the procedures focus on using the most simple way to evaluate and control water losses. Finally, the introduction of described methodology in Bratislava Water Company after many years of unsuccessful effort even with expensive sophisticated leakage equipment brought positive outputs and the graph line of water losses level is finally going down. The use of expensive multi-correlating equipment together with human resources on the basis of implementing the above described leakage monitoring will subsequently become more effective, as it shall pinpoint major leakages, disclosure and removal of that shall significantly contribute to the effective reduction of water losses.展开更多
With a water-supply network by dynamic programming. The minimal as an example, the network was optimized annual discounted costs were taken as an objective function and node pressure etc. as constraint conditions. The...With a water-supply network by dynamic programming. The minimal as an example, the network was optimized annual discounted costs were taken as an objective function and node pressure etc. as constraint conditions. The alternative pipe diameters were optimized as per enumeration method and the group allowing objective function with the least values would be the optimized one. It is proved the optimized pipe network reduced by 11.49% in terms of cost and the optimized ben- efits proved much significant.展开更多
Objective To assess the health safety of copper, steel and plastic water pipes by field water quality investigations. Methods Four consumers were randomly selected for each type of water pipes. Two consumers of every ...Objective To assess the health safety of copper, steel and plastic water pipes by field water quality investigations. Methods Four consumers were randomly selected for each type of water pipes. Two consumers of every type of the water pipes had used the water pipes for more than 1 year and the other 2 consumers had used the water pipes for less than 3 months. The terminal volume of tap water in copper and steel water pipes should be not less than 0.1 liter, whereas that in plastic water pipes should be not less than 1 liter. Results The mean values of the experimental results in the second field water quality investigation of the copper and steel water pipes met the Sanitary Standards for Drinking Water Quality. The items of water sample of the plastic water pipes met the requirements of the Sanitary Standards for Drinking Water Quality. Conclusion Copper, steel, and plastic pipes can be used as drinking water pipes.展开更多
Minimizing water loss in water supply networks is one of the objectives for protecting water resources. Currently, the large amount of water loss is mainly due to leakage of the pipeline network. The leaking of pipe c...Minimizing water loss in water supply networks is one of the objectives for protecting water resources. Currently, the large amount of water loss is mainly due to leakage of the pipeline network. The leaking of pipe can be caused by incorrect construction, impacted by external forces, or corroded pipe material and aging. Therefore, to control and predict the cracking area on pipe, it is necessary to collect data about pipe conditions, approve the solution of technology improvement and define the ability of pipe capacity from setting up to the first preparing time. This paper will demonstrate how to evaluate corrosion pipe under the age of pipe and the impact level of internal pressure pipe at different times, and will put forward solution of effective leaking management on water supply network.展开更多
In water distribution systems,water leakage from cracked water pipes is a major concern for water providers.Generally,the relationship between the leakage rate and the water pressure can be modeled by a power function...In water distribution systems,water leakage from cracked water pipes is a major concern for water providers.Generally,the relationship between the leakage rate and the water pressure can be modeled by a power function developed from the orifice equation.This paper presents an approximate solution for the computation of the steady-state leakage rate through a longitudinal line crack of a water distribution pipe considering the surrounding soil properties.The derived solution agrees well with results of numerical simulations.Compared with the traditional models,the new solution allows assessment of all the parameters that related with leakage including the pressure head inside the pipe,hydraulic conductivity,crack size and its position,and pipe size and its depth.展开更多
The vortex-induced nonlinear vibration of casing pipes in the deep water was studied considering the loads of current and combined wave-current. The vortex-induced vibration equation of a casing pipe was set up consid...The vortex-induced nonlinear vibration of casing pipes in the deep water was studied considering the loads of current and combined wave-current. The vortex-induced vibration equation of a casing pipe was set up considering the beam mode and Morison's nonlinear fluid loads as well as the vortex-excited loads. The approach of calculating vortex-excited nonlinear vibration by Galerkin's method was proposed. The natural vibration frequencies and modes were obtained, and the response including primary resonance induced by current and the composite resonance under combined wave-current for the 170 m long casing pipe in the 160 m depth of water were investigated. The results show that the dynamics response of casing pipe obviously increases, and the complicated response behaviors of casing pipe are described under combined wavecurrent.展开更多
We establish a single diode laser sensor system to obtain temperature and water concentration in CH4/air premixed flame.Line-of-sight properties are analyzed,but line-of-sight results are not path average values for t...We establish a single diode laser sensor system to obtain temperature and water concentration in CH4/air premixed flame.Line-of-sight properties are analyzed,but line-of-sight results are not path average values for temperature measurements.The measurements are performed on a flat burner based on scannedwavelength direct absorption spectroscopy using two adjacent water lines at 7153.75 and 7154.35 cm 1.Real-time results are acquired using a data acquisition card with a Labview data processing program.The standard uncertainties of the temperature and water concentration measurements are 2.3% and 5.1%,respectively.展开更多
An electrochemical mass spectrometry technique was developed based on a homemade analytical device for sequential analysis of the heavy metals with various speciations in the scales.Four speciations(e.g.,water-soluble...An electrochemical mass spectrometry technique was developed based on a homemade analytical device for sequential analysis of the heavy metals with various speciations in the scales.Four speciations(e.g.,water-soluble speciation,organic speciation,indissoluble speciation and elemental speciation)of heavy metals are sequentially extracted by H_(2)O,CH_(3)OH,EDTA-2Na and electrolysis for online electrospray ionization mass spectrometry(ESI-MS)detection.The method takes significant advantages,such as requiring no tedious offline sample pretreatment,high speed of analysis(20 min),high throughput(multi-metals),good sensitivity(0.5µg/L)and rich chemical information(four speciations).As a result,the rapid comprehensive characterization of four speciations of Pb,Ni,Cu,Zn,Fe,Ba,Mn,Cr and Ca in water pipe scales has been qualitatively achieved.It demonstrated that the present method is a powerful tool for the effective assessment of potential hazards in drinking water,which provides a new analytical idea for evaluating water quality.展开更多
Water shortage is one of the major water related problems for many cities in the world.The planning for utilization of reclaimed water has been or would be drafted in these cities.For using the reclaimed water soundly...Water shortage is one of the major water related problems for many cities in the world.The planning for utilization of reclaimed water has been or would be drafted in these cities.For using the reclaimed water soundly,Beijing planned to build a large scale reclaimed water pipe networks with multi-sources.In order to support the plan,the integrated hydraulic model of planning pipe network was developed based on EPANET supported by geographic information system(GIS).The complicated pipe network was divided into four weak conjunction subzones according to the distribution of reclaimed water plants and the elevation.It could provide a better solution for the problem of overhigh pressure in several regions of the network.Through the scenarios analy-sis in different subzones,some of the initial diameter of pipes in the network was adjusted.At last the pipe network planning scheme of reclaimed water was proposed.The proposed planning scheme could reach the balances between reclaimed water requirements and reclaimed water supplies,and provided a scientific basis for the reclaimed water utilization in Beijing.Now the scheme had been adopted by Beijing municipal government.展开更多
基金Scientific Research Fund of Institute of Engineering Mechanics,China Earthquake Administration under Grant Nos.2021EEEVL0204 and 2018A02。
文摘As an important part of nonstructural components,the seismic response of indoor water supply pipes deserves much attention.This paper presents shaking table test research on water supply pipes installed in a full-scale reinforced concrete(RC)frame structure.Different material pipes and different methods for penetrating the reinforced concrete floors are combined to evaluate the difference in seismic performance.Floor response spectra and pipe acceleration amplification factors based on test data are discussed and compared with code provisions.A seismic fragility study of displacement demand is conducted based on numerical simulation.The acceleration response and displacement response of different combinations are compared.The results show that the combination of different pipe materials and different passing-through methods can cause obvious differences in the seismic response of indoor riser pipes.
文摘Mathematical physics equations are often utilized to describe physical phenomena in various fields of science and engineering.One such equation is the Fourier equation,which is a commonly used and effective method for evaluating the effectiveness of temperature control measures for mass concrete.One important measure for temperature control in mass concrete is the use of cooling water pipes.However,the mismatch of grids between large-scale concrete models and small-scale cooling pipe models can result in a significant waste of calculation time when using the finite element method.Moreover,the temperature of the water in the cooling pipe needs to be iteratively calculated during the thermal transfer process.The substructure method can effectively solve this problem,and it has been validated by scholars.The Abaqus/Python secondary development technology provides engineers with enough flexibility to combine the substructure method with an iteration algorithm,which enables the creation of a parametric modeling calculation for cooling water pipes.This paper proposes such a method,which involves iterating the water pipe boundary and establishing the water pipe unit substructure to numerically simulate the concrete temperature field that contains a cooling water pipe.To verify the feasibility and accuracy of the proposed method,two classic numerical examples were analyzed.The results showed that this method has good applicability in cooling pipe calculations.When the value of the iteration parameterαis 0.4,the boundary temperature of the cooling water pipes can meet the accuracy requirements after 4∼5 iterations,effectively improving the computational efficiency.Overall,this approach provides a useful tool for engineers to analyze the temperature control measures accurately and efficiently for mass concrete,such as cooling water pipes,using Abaqus/Python secondary development.
基金supported by the FCT (PTDC/ECM/65731/2006)the 7FP European HYLOW Project (Grant No. 212423)
文摘This study is the result of ongoing research for a European Union 7th Framework Program Project regarding energy converters for very low heads, and aims to analyze optimization of new cost-effective hydraulic turbine designs for possible implementation in water supply systems (WSSs) or in other pressurized water pipe infrastructures, such as irrigation, wastewater, or drainage systems. A new methodology is presented based on a theoretical, technical and economic analysis. Viability studies focused on small power values for different pipe systems were investigated. Detailed analyses of alternative typical volumetric energy converters were conducted on the basis of mathematical and physical fundamentals as well as computational fluid dynamics (CFD) associated with the interaction between the flow conditions and the system operation. Important constraints (e.g., size, stability, efficiency, and continuous steady flow conditions) can be identified and a search for alternative rotary yolumetric converters is being conducted. As promising cost-effective solutions for the coming years, adapted rotor-dynamic turbomachines and non-conventional axial propeller devices were analyzed based on the basic principles of pumps operating as turbines, as well as through an extensive comparison between simulations and experimental tests.
文摘Solving the absent assignment problem of the shortest time limit in a weighted bipartite graph with the minimal weighted k-matching algorithm is unsuitable for situations in which large numbers of problems need to be addressed by large numbers of parties. This paper simplifies the algorithm of searching for the even alternating path that contains a maximal element using the minimal weighted k-matching theorem and intercept graph. A program for solving the maximal efficiency assignment problem was compiled. As a case study, the program was used to solve the assignment problem of water piping repair in the case of a large number of companies and broken pipes, and the validity of the program was verified.
文摘The article addresses the results of effective water losses prevention in public water supply systems, focusing on procedures for monitoring hidden leaks as the main part of losses and as the first step to control and prevent them. The described methodology has been applied based on a cross-border cooperation between twin capital cities Vienna and Bratislava in the Central Europe Region within the project deWaloP (Developing Water Loss Prevention) and adopted in Bratislava Water Company (BVS) in the Slovak Republic. The paper provides a complex of simple and easily available practices for analyses of water distribution measurements bringing essential information as to the necessity to use advanced procedures to actively reduce leakage. These practices involve minimum night flows analyses, hydrodynamic pressures analyses, pinpointing of water leakages by working with valves in the water network, the methodology of setting alarm limits for measured data, as well as use of advanced practices to obtain missing topologic data. As the water infrastructure in former socialistic countries are in bad technical condition and the lack of pertinent operational data is a significant obstacle to the application of a more sophisticated methodology based on GIS and other information systems, the procedures focus on using the most simple way to evaluate and control water losses. Finally, the introduction of described methodology in Bratislava Water Company after many years of unsuccessful effort even with expensive sophisticated leakage equipment brought positive outputs and the graph line of water losses level is finally going down. The use of expensive multi-correlating equipment together with human resources on the basis of implementing the above described leakage monitoring will subsequently become more effective, as it shall pinpoint major leakages, disclosure and removal of that shall significantly contribute to the effective reduction of water losses.
文摘With a water-supply network by dynamic programming. The minimal as an example, the network was optimized annual discounted costs were taken as an objective function and node pressure etc. as constraint conditions. The alternative pipe diameters were optimized as per enumeration method and the group allowing objective function with the least values would be the optimized one. It is proved the optimized pipe network reduced by 11.49% in terms of cost and the optimized ben- efits proved much significant.
基金This work was sponsored by the International Copper Association.
文摘Objective To assess the health safety of copper, steel and plastic water pipes by field water quality investigations. Methods Four consumers were randomly selected for each type of water pipes. Two consumers of every type of the water pipes had used the water pipes for more than 1 year and the other 2 consumers had used the water pipes for less than 3 months. The terminal volume of tap water in copper and steel water pipes should be not less than 0.1 liter, whereas that in plastic water pipes should be not less than 1 liter. Results The mean values of the experimental results in the second field water quality investigation of the copper and steel water pipes met the Sanitary Standards for Drinking Water Quality. The items of water sample of the plastic water pipes met the requirements of the Sanitary Standards for Drinking Water Quality. Conclusion Copper, steel, and plastic pipes can be used as drinking water pipes.
文摘Minimizing water loss in water supply networks is one of the objectives for protecting water resources. Currently, the large amount of water loss is mainly due to leakage of the pipeline network. The leaking of pipe can be caused by incorrect construction, impacted by external forces, or corroded pipe material and aging. Therefore, to control and predict the cracking area on pipe, it is necessary to collect data about pipe conditions, approve the solution of technology improvement and define the ability of pipe capacity from setting up to the first preparing time. This paper will demonstrate how to evaluate corrosion pipe under the age of pipe and the impact level of internal pressure pipe at different times, and will put forward solution of effective leaking management on water supply network.
基金Project (No. 2012AA062608) supported by the National High-Tech R&D Program (863) of China
文摘In water distribution systems,water leakage from cracked water pipes is a major concern for water providers.Generally,the relationship between the leakage rate and the water pressure can be modeled by a power function developed from the orifice equation.This paper presents an approximate solution for the computation of the steady-state leakage rate through a longitudinal line crack of a water distribution pipe considering the surrounding soil properties.The derived solution agrees well with results of numerical simulations.Compared with the traditional models,the new solution allows assessment of all the parameters that related with leakage including the pressure head inside the pipe,hydraulic conductivity,crack size and its position,and pipe size and its depth.
文摘The vortex-induced nonlinear vibration of casing pipes in the deep water was studied considering the loads of current and combined wave-current. The vortex-induced vibration equation of a casing pipe was set up considering the beam mode and Morison's nonlinear fluid loads as well as the vortex-excited loads. The approach of calculating vortex-excited nonlinear vibration by Galerkin's method was proposed. The natural vibration frequencies and modes were obtained, and the response including primary resonance induced by current and the composite resonance under combined wave-current for the 170 m long casing pipe in the 160 m depth of water were investigated. The results show that the dynamics response of casing pipe obviously increases, and the complicated response behaviors of casing pipe are described under combined wavecurrent.
基金supported by the State Key Laboratory of Laser Interaction with Matter under Grant No.SKL110905
文摘We establish a single diode laser sensor system to obtain temperature and water concentration in CH4/air premixed flame.Line-of-sight properties are analyzed,but line-of-sight results are not path average values for temperature measurements.The measurements are performed on a flat burner based on scannedwavelength direct absorption spectroscopy using two adjacent water lines at 7153.75 and 7154.35 cm 1.Real-time results are acquired using a data acquisition card with a Labview data processing program.The standard uncertainties of the temperature and water concentration measurements are 2.3% and 5.1%,respectively.
基金This work was supported by the National Natural Science Foundation of China(Nos.21727812,21705016)the Doctoral Start-up Fund of East China University of Technology,China(No.DHBK2017115)the Open Fund of Jiangxi Provincial Key Laboratory of Mass Spectrometry Science and Instrumentation,China(No.JXMS202117).
文摘An electrochemical mass spectrometry technique was developed based on a homemade analytical device for sequential analysis of the heavy metals with various speciations in the scales.Four speciations(e.g.,water-soluble speciation,organic speciation,indissoluble speciation and elemental speciation)of heavy metals are sequentially extracted by H_(2)O,CH_(3)OH,EDTA-2Na and electrolysis for online electrospray ionization mass spectrometry(ESI-MS)detection.The method takes significant advantages,such as requiring no tedious offline sample pretreatment,high speed of analysis(20 min),high throughput(multi-metals),good sensitivity(0.5µg/L)and rich chemical information(four speciations).As a result,the rapid comprehensive characterization of four speciations of Pb,Ni,Cu,Zn,Fe,Ba,Mn,Cr and Ca in water pipe scales has been qualitatively achieved.It demonstrated that the present method is a powerful tool for the effective assessment of potential hazards in drinking water,which provides a new analytical idea for evaluating water quality.
基金This work was supported by the Beijing Municipal Planning Committee.The authors thank Mr.Wang Jun and Mr.Liu Jing for their helps.
文摘Water shortage is one of the major water related problems for many cities in the world.The planning for utilization of reclaimed water has been or would be drafted in these cities.For using the reclaimed water soundly,Beijing planned to build a large scale reclaimed water pipe networks with multi-sources.In order to support the plan,the integrated hydraulic model of planning pipe network was developed based on EPANET supported by geographic information system(GIS).The complicated pipe network was divided into four weak conjunction subzones according to the distribution of reclaimed water plants and the elevation.It could provide a better solution for the problem of overhigh pressure in several regions of the network.Through the scenarios analy-sis in different subzones,some of the initial diameter of pipes in the network was adjusted.At last the pipe network planning scheme of reclaimed water was proposed.The proposed planning scheme could reach the balances between reclaimed water requirements and reclaimed water supplies,and provided a scientific basis for the reclaimed water utilization in Beijing.Now the scheme had been adopted by Beijing municipal government.