A variable chlorine decay rate modeling of the Matsapha town water network was developed based on initial chlorine dosages. The model was adequately described by a second order rate function of the chlorine decay rate...A variable chlorine decay rate modeling of the Matsapha town water network was developed based on initial chlorine dosages. The model was adequately described by a second order rate function of the chlorine decay rate with respect to the initial chlorine dose applied. Simulations of chlorine residuals within the Matsapha water distribution network were run using the EPANET 2.0 program at different initial chlorine dosages and using the variable decay rate as described by the second order model. The measurement results indicated that the use of constant decay rate tended to underestimate chlorine residuals leading to potentially excess dosages with the associated chemical cost and side effects. The error between the two rate models varied between 0% and 15%. It is suggested that the use of water quality simulation programs such as EPANET be enhanced through the extension programs that accommodate variable rate modeling of chlorine residuals within distribution systems.展开更多
The effects of cast iron pipe corrosion onwater quality risk and microbial ecology in drinking water distribution systems(DWDSs)were investigated.It was found that trihalomethane(THMs)concentration and antibiotic resi...The effects of cast iron pipe corrosion onwater quality risk and microbial ecology in drinking water distribution systems(DWDSs)were investigated.It was found that trihalomethane(THMs)concentration and antibiotic resistance genes(ARGs)increased sharply in the old DWDSs.Under the same residual chlorine concentration conditions,the adenosine triphos-phate concentration in the effluent of old DWDSs(Eff-old)was significantly higher than that in the effluent of newDWDSs.Moreover,stronger bioflocculation ability andweaker hy-drophobicity coexisted in the extracellular polymeric substances of Eff-old,meanwhile,iron particles could be well inserted into the structure of the biofilms to enhance the mechanical strength and stability of the biofilms,hence enhancing the formation of THMs.Old DWDSs significantly influenced the microbial community of bulk water and triggered stronger mi-crobial antioxidant systems response,resulting in higher ARGs abundance.Corroded cast iron pipes induced a unique interaction system of biofilms,chlorine,and corrosion prod-ucts.Therefore,as the age of cast iron pipes increases,the fluctuation of water quality and microbial ecology should be paid more attention to maintain the safety of tap water.展开更多
The qualified finished water from water treatment plants(WTPs) may become discolored and deteriorated during transportation in drinking water distribution systems(DWDSs), which affected tap water quality seriously. Th...The qualified finished water from water treatment plants(WTPs) may become discolored and deteriorated during transportation in drinking water distribution systems(DWDSs), which affected tap water quality seriously. This water stability problem often occurs due to pipe corrosion and the destabilization of corrosion scales. This paper provides a comprehensive review of pipe corrosion in DWDSs, including corrosion process, corrosion scale formation, influencing factors and monitoring technologies utilized in DWDSs. In terms of corrosion process, corrosion occurrence, development mechanisms, currently applied assays, and indices used to determine the corrosion possibility are summarized, as well as the chemical and bacterial influences. In terms of scale formation, explanations for the nature of corrosion and scale formation mechanisms are discussed and its typical multilayered structure is illustrated. Furthermore, the influences of water quality and microbial activity on scale transformation are comprehensively discussed. Corrosion-related bacteria at the genus level and their associated corrosion mechanism are also summarized. This review helps deepen the current understanding of pipe corrosion and scale formation in DWDSs, providing guidance for water supply utilities to ensure effective measures to maintain water quality stability and guarantee drinking water safety.展开更多
文摘A variable chlorine decay rate modeling of the Matsapha town water network was developed based on initial chlorine dosages. The model was adequately described by a second order rate function of the chlorine decay rate with respect to the initial chlorine dose applied. Simulations of chlorine residuals within the Matsapha water distribution network were run using the EPANET 2.0 program at different initial chlorine dosages and using the variable decay rate as described by the second order model. The measurement results indicated that the use of constant decay rate tended to underestimate chlorine residuals leading to potentially excess dosages with the associated chemical cost and side effects. The error between the two rate models varied between 0% and 15%. It is suggested that the use of water quality simulation programs such as EPANET be enhanced through the extension programs that accommodate variable rate modeling of chlorine residuals within distribution systems.
基金supported by the National Natural Science Foundation of China(Nos.52000043,and 51838005)the intro-duced innovative R&D team project under the“The Pearl River Talent Recruitment Program”of Guangdong Province(No.2019ZT08L387)+2 种基金the Guangdong Natural Science Foundation(No.2023A1515011509)the Science and Technology Research Project of Guangzhou(Nos.202201020177,202102020986 and 202102021044)the special fund from Key Laboratory of Drinking Water Science and Technology,Research Center for Eco-Environmental Sciences,Chinese Academy of Sciences(No.20K01KLDWST).
文摘The effects of cast iron pipe corrosion onwater quality risk and microbial ecology in drinking water distribution systems(DWDSs)were investigated.It was found that trihalomethane(THMs)concentration and antibiotic resistance genes(ARGs)increased sharply in the old DWDSs.Under the same residual chlorine concentration conditions,the adenosine triphos-phate concentration in the effluent of old DWDSs(Eff-old)was significantly higher than that in the effluent of newDWDSs.Moreover,stronger bioflocculation ability andweaker hy-drophobicity coexisted in the extracellular polymeric substances of Eff-old,meanwhile,iron particles could be well inserted into the structure of the biofilms to enhance the mechanical strength and stability of the biofilms,hence enhancing the formation of THMs.Old DWDSs significantly influenced the microbial community of bulk water and triggered stronger mi-crobial antioxidant systems response,resulting in higher ARGs abundance.Corroded cast iron pipes induced a unique interaction system of biofilms,chlorine,and corrosion prod-ucts.Therefore,as the age of cast iron pipes increases,the fluctuation of water quality and microbial ecology should be paid more attention to maintain the safety of tap water.
基金supported by the Shandong Provincial Key Research and Development Program- Major Scientific and Technological Innovation Project (No. 2020CXGC011406)the R&D project of Suzhou Water Resource and Management (No. 2020011)the National Water Major Project (Nos. 2018ZX07111-006 , 2012ZX07404-002 , 2012ZX07403-001)。
文摘The qualified finished water from water treatment plants(WTPs) may become discolored and deteriorated during transportation in drinking water distribution systems(DWDSs), which affected tap water quality seriously. This water stability problem often occurs due to pipe corrosion and the destabilization of corrosion scales. This paper provides a comprehensive review of pipe corrosion in DWDSs, including corrosion process, corrosion scale formation, influencing factors and monitoring technologies utilized in DWDSs. In terms of corrosion process, corrosion occurrence, development mechanisms, currently applied assays, and indices used to determine the corrosion possibility are summarized, as well as the chemical and bacterial influences. In terms of scale formation, explanations for the nature of corrosion and scale formation mechanisms are discussed and its typical multilayered structure is illustrated. Furthermore, the influences of water quality and microbial activity on scale transformation are comprehensively discussed. Corrosion-related bacteria at the genus level and their associated corrosion mechanism are also summarized. This review helps deepen the current understanding of pipe corrosion and scale formation in DWDSs, providing guidance for water supply utilities to ensure effective measures to maintain water quality stability and guarantee drinking water safety.