Experimental Investigation of Transient Heat Transferin the Once-Through Boiler Water Separator
1
作者 Yang Dong Chen Tingkuan Zheng Jianxu(National Laboratory of Multiphase Flow in Power Engineering, Xi’an Jiaotong University, Xi’an,710049, China) 《Journal of Thermal Science》 SCIE EI CAS CSCD 1997年第1期44-50,共7页
The transient heat transfer between working fluid and inner wall of 600 MW supercritical pressureboiler's water separator model during start-up was experimentally explored. The test conditions forwater steam two-p... The transient heat transfer between working fluid and inner wall of 600 MW supercritical pressureboiler's water separator model during start-up was experimentally explored. The test conditions forwater steam two-phase were as follows: pressure P = 3 ~ 11 MPa, mass now M = 0.2 ~ 0.35 kg/s,and mass quality x = O.2 ~ 0.8; for subcooled water P = 3 ~ 11 MPa, M = 0.2 ~ 0.35 kg/s, andsubcooled degree △θ = 10℃. By using an accurate and tractable inverse heat conduction solution,the correlations of single phase and twouphase transient heat transfer coefficients were obtained. Theexperimental results demonstrated the heat transfer enhanced for subcooled water and water steammixture compared with fully developed turbulent flow in tube. The increasing heat transfer effect maybe attributed to the deformation or destruction f the boundary layer. 展开更多
关键词 experimental investigation water separator inverse heat conduction transient heat transfer
原文传递
超临界直流锅炉汽水分离器瞬态传热的研究 被引量:3
2
作者 杨冬 陈听宽 +3 位作者 陈宣政 戚光泽 朱国桢 周一功 《西安交通大学学报》 EI CAS CSCD 北大核心 1994年第6期86-91,共6页
阐述了在高压汽水试验回路上进行的600MW超临界直流锅炉汽水分离器模型,在锅炉实际启动过程中介质对筒壁瞬态传热试验研究,试验参数范围为P=3~11MPa,质量流量M=0.2~0.35kg/s,干度x=0.2~0.8.... 阐述了在高压汽水试验回路上进行的600MW超临界直流锅炉汽水分离器模型,在锅炉实际启动过程中介质对筒壁瞬态传热试验研究,试验参数范围为P=3~11MPa,质量流量M=0.2~0.35kg/s,干度x=0.2~0.8.在此参数范围内通过试验研究,由导热反问题方法根据试验数据拟合出动态过程中介质对分离器模型内壁的放热系数关联式,并按模化理论推广到实际设备,为计算动态过程中汽水分离器热应力和优化启动程序提供了重要依据。 展开更多
关键词 汽水分离器 瞬态传热 直流锅炉