A simple, sensitive and convenient ion chromatography(IC) method was established for the simultaneous determination of twelve water-soluble inorganic anions(F -, Cl -, NO - 2, NO - 3, SO 2- 3, SO 2- ...A simple, sensitive and convenient ion chromatography(IC) method was established for the simultaneous determination of twelve water-soluble inorganic anions(F -, Cl -, NO - 2, NO - 3, SO 2- 3, SO 2- 4, PO 3- 4), and fifteen water-soluble organic ions(formate, acetate, MSA, oxalate, malonate, succinate, phthalates, etc.) in atmospheric aerosols. The linear concentrations ranged from 0.005 μg/m 3 to 500 μg/m 3(r = 0.999—0.9999). The relative standard deviation(RSD) were 0.43%—2.00% and the detection limits were from 2.7 ng/m 3 to 88 ng/m 3. The proposed method was successfully applied to the simultaneous determination of those inorganic ions and organic ions in PM 2.5 of Beijing.展开更多
Combining the system of rapid collection of ambient particles and ion chromatography, the system of rapid collection of fine particles and ion chromatography (RCFP-IC) was established to automatically analyze on-lin...Combining the system of rapid collection of ambient particles and ion chromatography, the system of rapid collection of fine particles and ion chromatography (RCFP-IC) was established to automatically analyze on-line the concentrations of water-soluble ions in ambient particles. Here, the general scheme of RCFP-IC is described and its basic performance is tested. The detection limit of RCFP-IC for SO4^2-, NO3^-, NO2^-, Cl^- and F- is below 0.3μg m^-3. The collection efficiency of RCFP-IC increases rapidly with increasing sized particles. For particles larger than 300 nm, the collection efficiency approaches 100%. The precision of RCFP-IC is more than 90% over 28 repetitions. The response of RCFP-IC is very sensitive and no obvious cross-pollution is found during measurement. A comparison of RCFP-IC with an integrated filter measurement indicates that the measurement of RCFP-IC is comparable in both laboratory experiments and field observations. The results of the field experiment prove that RCFP-IC is an effective on-line monitoring system and is helpful in source apportionment and pollution episode monitoring.展开更多
Thirty-six daily time interval PM2.5 samples were collected in different seasonal dates in urban Shanghai, and the concentrations of four anions (Cl- , NO3-, SO4^2-, C2O4^2-) and five cations (NH+, Na+, K+, Ca2...Thirty-six daily time interval PM2.5 samples were collected in different seasonal dates in urban Shanghai, and the concentrations of four anions (Cl- , NO3-, SO4^2-, C2O4^2-) and five cations (NH+, Na+, K+, Ca2+, Mg2+) were analyzed with ion chromatography. Sulfate, nitrate and ammonium were found to be the dominant species, accounting for about 80% of the total ions. The daily nitrate to sulfate mass ratio ranged from 0.31 to 0.82, indicating that coal combustion was still the main pollution source in Shanghai. The equivalent ratio of ammonium to stun of nitrate and sulfate showed fixed diurnal variation pattern in all the sampling days with higher values in the nighttime, suggesting that fine particles in the night were more neutralized. The oxalate to sulfate ratio was lower in the winter sampling days than that in hotter summer and autumn sampling days. Oxalate was significantly correlated with sulfate in winter sampling days, but not in the summer and autumn, suggesting that the formation mechanism of oxalate and sulfate was similar in winter, however different in hot days.展开更多
The concentrations of water soluble ions (Na++, NH++-4, K++, Mg+{2+}, Ca+{2+}, NO+--3, Cl+-, and SO+{2-}-4) in PM-{10} samples collected on cellulose filters by a medium-volume cascade impactor were determined, which ...The concentrations of water soluble ions (Na++, NH++-4, K++, Mg+{2+}, Ca+{2+}, NO+--3, Cl+-, and SO+{2-}-4) in PM-{10} samples collected on cellulose filters by a medium-volume cascade impactor were determined, which were obtained from three kinds of areas in Chongqing: industrial area (Jiulongpo district), commercial and residential area (Jiangbei district) and background area (Jinyun Mountain in the Beibei district). The results showed that except for the background site, the annual average values of PM-{10} are 23%-61% higher than the national air quality standard (GradeⅡ) ({0.1} mg/m+3), even that the value of the control site is still 20% higher than American standard ({0.05} mg/m+3). This implied that serious pollution of fine particles occurred in Chongqing. Nine kinds of soluble ions in water of PM-{10} were analyzed by ion chromatography (IC) and the annual average concentrations follow the order of >>>, and >>>>. Their values were different in these areas: the industrial area>the commercial and living area>the control area. As for NH++-4, K++, Ca+{2+}, NO+--3 and SO+{2-}-4, their seasonal average concentrations show a similar variation trend: the values in spring and fall were higher than those in summer and winter. The seasonal average concentrations of , , and are much lower than those of other ions. However, the concentrations of changed more greatly in different seasons than those of the other three ions. Correlation coefficients showed that the three areas have been polluted by coal smoke and dust to different extents, while some local resources of pollution should be taken into consideration as well.展开更多
Atmospheric fine particulate matters (PM2.5) were collected with an Envirotech Instrument (Model APM 550) at the roof of Khundkur Mukarram Hussain Science Building, University of Dhaka, Bangladesh between January and ...Atmospheric fine particulate matters (PM2.5) were collected with an Envirotech Instrument (Model APM 550) at the roof of Khundkur Mukarram Hussain Science Building, University of Dhaka, Bangladesh between January and February, 2013. PM2.5 samples were collected on Quartz fiber filters during day and night time. Water soluble ions (sulfate, nitrate, phosphate, chloride, bromide, sodium, potassium and calcium) were analyzed with Ion Chromatography (Model 881, Metrohm Ltd., Switzerland) and Flame photometer (Model PFP7, Jenway, UK). Average PM2.5 mass was 136.1 μg·mDž during day time and 246.8 μg·mDž during night time with a total average of 191.4 μg·mDž. Nighttime PM2.5 concentration was about double compared than that of daytime presumable due to the low ambient temperatures with high emissions from heavy duty vehicles. The 24-hour average PM2.5 mass (average of day and night) was about eight times higher than WHO (25.0 μg·mDž) and about three times higher than DoE, Bangladesh (65.0 μg·mDž) limit values. The total average concentrations of sulfate, nitrate, phosphate, bromide, chloride, sodium, potassium and calcium were 5.30, 7.75, 0.62, 0.16, 1.19, 1.30, 8.11, and 3.09 μg·mDž, respectively. The concentrations of the water soluble ions were much higher during nighttime than daytime except nitrate, bromide and potassium. Excellent correlations were observed between sulfate and nitrate, sodium and chloride, bromide and phosphate indicating joint sources of origin. Potassium, sulfate, nitrate and calcium are the most dominant species in PM2.5. Water soluble ionic components in Dhaka contributed about 15% mass of the PM2.5. Ratio analysis showed that sodium and chloride were from mainly sea salt. Potassium has varieties of sources other than biomass burning. Sulfate and nitrate are mainly from fossil fuel origin. This is the first study of the day and night variation of the water soluble ionic species at the fine particulate matters (PM2.5) in Bangladesh.展开更多
Heavy metal contaminated water sources can cause serious health problems for humans,animals,and plants.Heavy metals can lead to the decrease or loss of liver,kidney,and brain function.Objective:The aim of this researc...Heavy metal contaminated water sources can cause serious health problems for humans,animals,and plants.Heavy metals can lead to the decrease or loss of liver,kidney,and brain function.Objective:The aim of this research is to examine the effect of charge on adsorbents in the removal of metal cations.Study Design&Methods:Standard solutions of Ca,Cu,Pb,and Zn with concentrations of 1,000 ppm were treated with sodium carbonate and sodium phosphate with various charges.Then,the solutions were placed on a shaker for 24 h,centrifuged,and the supernatant was analyzed using ICP-AES(Inductively Coupled Plasma-Atomic Emission Spectrometry).Results:The order of average metal removal by sodium phosphates is:dibasic(99.3%)>monobasic(96.5%)>tribasic(95.4%).The average metal removal by sodium carbonate and bicarbonate is 98.5% and 96.4% respectively.Conclusion:The adsorbent removability depends on the relationship between the charge present on the metal and the charge on the adsorbent.Thus,metal cations in this study with a+2 charge had a greater affinity for the adsorbent with-2 charged ligands,dibasic sodium phosphate and sodium carbonate.展开更多
Based on Total Suspended Particulates (TSP) observations of Tazhong, Tikanli, Kashi and Minfeng in 2009, combined wa- ter-soluble inorganic ion analyses, this paper studied the spatial and temporal distribution of T...Based on Total Suspended Particulates (TSP) observations of Tazhong, Tikanli, Kashi and Minfeng in 2009, combined wa- ter-soluble inorganic ion analyses, this paper studied the spatial and temporal distribution of TSP in the Tarim Basin and analyzed concentration characteristics. The results are as follows: (1) monthly average TSP concentrations shows a similar trend in Tazhong, Tikanli, Kashi and Minfeng with peak values in April-May and low values in November-December. As for the quarter average mass concentration trends, spring has the highest value, followed by summer and autumn, and winter is the lowest; (2) total annual concentration trend of water-soluble inorganic ions in TSP is as follows: Tazhong 〉 Tikanli 〉 Minfeng 〉 Kashi. SO4^2- concentra- tions are 58%, 50%, 54% and 51% of total ion concentration; Ca^2+ concentrations are 13%, 16%, 16% and 11%; Na^+ concentra- tions are 12%, 13%, 10% and 12% and Cl^- concentrations are 12%, 16%, 11% and 22%, respectively. Therefore, sulfate, calcium, sodium and chloride ions are the main inorganic components of TSP in the Tarim Basin; (3) the correlation coefficients of anions and cations in Tikanli, Minfeng, Kashi and Tazhong are 0.99, 0.99, 0.25 and 0.91, respectively; the average anion concentrations are 2.57, 2.12, 2.15 and 3.02 times the average cation concentrations, indicating that ions were unbalanced; (4) SO4^2-/NO3^- ratio is much larger than the ratio of coal-fired emissions SO4^2-/NO3^-, thus the impact of fixed emission sources in the four regions on the atmosphere is far greater than that of mobile emission sources.展开更多
文摘A simple, sensitive and convenient ion chromatography(IC) method was established for the simultaneous determination of twelve water-soluble inorganic anions(F -, Cl -, NO - 2, NO - 3, SO 2- 3, SO 2- 4, PO 3- 4), and fifteen water-soluble organic ions(formate, acetate, MSA, oxalate, malonate, succinate, phthalates, etc.) in atmospheric aerosols. The linear concentrations ranged from 0.005 μg/m 3 to 500 μg/m 3(r = 0.999—0.9999). The relative standard deviation(RSD) were 0.43%—2.00% and the detection limits were from 2.7 ng/m 3 to 88 ng/m 3. The proposed method was successfully applied to the simultaneous determination of those inorganic ions and organic ions in PM 2.5 of Beijing.
基金This work was supported by the National Natural Science Foundation of China under Grant No. 40525016.
文摘Combining the system of rapid collection of ambient particles and ion chromatography, the system of rapid collection of fine particles and ion chromatography (RCFP-IC) was established to automatically analyze on-line the concentrations of water-soluble ions in ambient particles. Here, the general scheme of RCFP-IC is described and its basic performance is tested. The detection limit of RCFP-IC for SO4^2-, NO3^-, NO2^-, Cl^- and F- is below 0.3μg m^-3. The collection efficiency of RCFP-IC increases rapidly with increasing sized particles. For particles larger than 300 nm, the collection efficiency approaches 100%. The precision of RCFP-IC is more than 90% over 28 repetitions. The response of RCFP-IC is very sensitive and no obvious cross-pollution is found during measurement. A comparison of RCFP-IC with an integrated filter measurement indicates that the measurement of RCFP-IC is comparable in both laboratory experiments and field observations. The results of the field experiment prove that RCFP-IC is an effective on-line monitoring system and is helpful in source apportionment and pollution episode monitoring.
基金Project supported by the National Natural Science Foundation of China(Grant No.20877052)the Shanghai Leading Academic Discipline Project(Grant No.S30109)
文摘Thirty-six daily time interval PM2.5 samples were collected in different seasonal dates in urban Shanghai, and the concentrations of four anions (Cl- , NO3-, SO4^2-, C2O4^2-) and five cations (NH+, Na+, K+, Ca2+, Mg2+) were analyzed with ion chromatography. Sulfate, nitrate and ammonium were found to be the dominant species, accounting for about 80% of the total ions. The daily nitrate to sulfate mass ratio ranged from 0.31 to 0.82, indicating that coal combustion was still the main pollution source in Shanghai. The equivalent ratio of ammonium to stun of nitrate and sulfate showed fixed diurnal variation pattern in all the sampling days with higher values in the nighttime, suggesting that fine particles in the night were more neutralized. The oxalate to sulfate ratio was lower in the winter sampling days than that in hotter summer and autumn sampling days. Oxalate was significantly correlated with sulfate in winter sampling days, but not in the summer and autumn, suggesting that the formation mechanism of oxalate and sulfate was similar in winter, however different in hot days.
文摘The concentrations of water soluble ions (Na++, NH++-4, K++, Mg+{2+}, Ca+{2+}, NO+--3, Cl+-, and SO+{2-}-4) in PM-{10} samples collected on cellulose filters by a medium-volume cascade impactor were determined, which were obtained from three kinds of areas in Chongqing: industrial area (Jiulongpo district), commercial and residential area (Jiangbei district) and background area (Jinyun Mountain in the Beibei district). The results showed that except for the background site, the annual average values of PM-{10} are 23%-61% higher than the national air quality standard (GradeⅡ) ({0.1} mg/m+3), even that the value of the control site is still 20% higher than American standard ({0.05} mg/m+3). This implied that serious pollution of fine particles occurred in Chongqing. Nine kinds of soluble ions in water of PM-{10} were analyzed by ion chromatography (IC) and the annual average concentrations follow the order of >>>, and >>>>. Their values were different in these areas: the industrial area>the commercial and living area>the control area. As for NH++-4, K++, Ca+{2+}, NO+--3 and SO+{2-}-4, their seasonal average concentrations show a similar variation trend: the values in spring and fall were higher than those in summer and winter. The seasonal average concentrations of , , and are much lower than those of other ions. However, the concentrations of changed more greatly in different seasons than those of the other three ions. Correlation coefficients showed that the three areas have been polluted by coal smoke and dust to different extents, while some local resources of pollution should be taken into consideration as well.
文摘Atmospheric fine particulate matters (PM2.5) were collected with an Envirotech Instrument (Model APM 550) at the roof of Khundkur Mukarram Hussain Science Building, University of Dhaka, Bangladesh between January and February, 2013. PM2.5 samples were collected on Quartz fiber filters during day and night time. Water soluble ions (sulfate, nitrate, phosphate, chloride, bromide, sodium, potassium and calcium) were analyzed with Ion Chromatography (Model 881, Metrohm Ltd., Switzerland) and Flame photometer (Model PFP7, Jenway, UK). Average PM2.5 mass was 136.1 μg·mDž during day time and 246.8 μg·mDž during night time with a total average of 191.4 μg·mDž. Nighttime PM2.5 concentration was about double compared than that of daytime presumable due to the low ambient temperatures with high emissions from heavy duty vehicles. The 24-hour average PM2.5 mass (average of day and night) was about eight times higher than WHO (25.0 μg·mDž) and about three times higher than DoE, Bangladesh (65.0 μg·mDž) limit values. The total average concentrations of sulfate, nitrate, phosphate, bromide, chloride, sodium, potassium and calcium were 5.30, 7.75, 0.62, 0.16, 1.19, 1.30, 8.11, and 3.09 μg·mDž, respectively. The concentrations of the water soluble ions were much higher during nighttime than daytime except nitrate, bromide and potassium. Excellent correlations were observed between sulfate and nitrate, sodium and chloride, bromide and phosphate indicating joint sources of origin. Potassium, sulfate, nitrate and calcium are the most dominant species in PM2.5. Water soluble ionic components in Dhaka contributed about 15% mass of the PM2.5. Ratio analysis showed that sodium and chloride were from mainly sea salt. Potassium has varieties of sources other than biomass burning. Sulfate and nitrate are mainly from fossil fuel origin. This is the first study of the day and night variation of the water soluble ionic species at the fine particulate matters (PM2.5) in Bangladesh.
文摘Heavy metal contaminated water sources can cause serious health problems for humans,animals,and plants.Heavy metals can lead to the decrease or loss of liver,kidney,and brain function.Objective:The aim of this research is to examine the effect of charge on adsorbents in the removal of metal cations.Study Design&Methods:Standard solutions of Ca,Cu,Pb,and Zn with concentrations of 1,000 ppm were treated with sodium carbonate and sodium phosphate with various charges.Then,the solutions were placed on a shaker for 24 h,centrifuged,and the supernatant was analyzed using ICP-AES(Inductively Coupled Plasma-Atomic Emission Spectrometry).Results:The order of average metal removal by sodium phosphates is:dibasic(99.3%)>monobasic(96.5%)>tribasic(95.4%).The average metal removal by sodium carbonate and bicarbonate is 98.5% and 96.4% respectively.Conclusion:The adsorbent removability depends on the relationship between the charge present on the metal and the charge on the adsorbent.Thus,metal cations in this study with a+2 charge had a greater affinity for the adsorbent with-2 charged ligands,dibasic sodium phosphate and sodium carbonate.
基金supported by Central Nonprofit Research Institutes Fundamental Research Funds for Project(No.IDM201003)Natural Science Foundation of China(Nos.41175017+1 种基金41175140)China Desert Meteorological Science Research Funds(Sqj2009014)
文摘Based on Total Suspended Particulates (TSP) observations of Tazhong, Tikanli, Kashi and Minfeng in 2009, combined wa- ter-soluble inorganic ion analyses, this paper studied the spatial and temporal distribution of TSP in the Tarim Basin and analyzed concentration characteristics. The results are as follows: (1) monthly average TSP concentrations shows a similar trend in Tazhong, Tikanli, Kashi and Minfeng with peak values in April-May and low values in November-December. As for the quarter average mass concentration trends, spring has the highest value, followed by summer and autumn, and winter is the lowest; (2) total annual concentration trend of water-soluble inorganic ions in TSP is as follows: Tazhong 〉 Tikanli 〉 Minfeng 〉 Kashi. SO4^2- concentra- tions are 58%, 50%, 54% and 51% of total ion concentration; Ca^2+ concentrations are 13%, 16%, 16% and 11%; Na^+ concentra- tions are 12%, 13%, 10% and 12% and Cl^- concentrations are 12%, 16%, 11% and 22%, respectively. Therefore, sulfate, calcium, sodium and chloride ions are the main inorganic components of TSP in the Tarim Basin; (3) the correlation coefficients of anions and cations in Tikanli, Minfeng, Kashi and Tazhong are 0.99, 0.99, 0.25 and 0.91, respectively; the average anion concentrations are 2.57, 2.12, 2.15 and 3.02 times the average cation concentrations, indicating that ions were unbalanced; (4) SO4^2-/NO3^- ratio is much larger than the ratio of coal-fired emissions SO4^2-/NO3^-, thus the impact of fixed emission sources in the four regions on the atmosphere is far greater than that of mobile emission sources.