In Saint-Louis, Senegal, a constructed wetland with horizontal flow reed beds (FHa and FHb) has demonstrated significant efficacy in treating municipal wastewater. Analyzing various treatment stages, the system showed...In Saint-Louis, Senegal, a constructed wetland with horizontal flow reed beds (FHa and FHb) has demonstrated significant efficacy in treating municipal wastewater. Analyzing various treatment stages, the system showed only a slight temperature variation, from an influent average of 26.3°C to an effluent of 24.7°C. Electrical conductivity decreased from 1331 mS/cm to 974.5 mS/cm post-primary treatment, with suspended solids (SS) dramatically reduced from 718.9 mg/L to 5.7 mg/L in the final effluent. Biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) saw a notable decrease, from initial levels of 655.6 mg/L and 1240 mg/L to 2.3 mg/L and 71.3 mg/L, respectively. Nitrogenous compounds (N-TN) and phosphates () also decreased significantly, indicating the system’s nutrient removal capacity. Microbiological analysis revealed a reduction in fecal coliforms from 7.5 Ulog/100ml to 1.8 Ulog/100ml and a complete elimination of helminth eggs. The presence of Phragmites and Typha was instrumental in enhancing these reductions. The system’s compliance with the Senegalese standards for disposal into natural environments, WHO recommendations for unrestricted water reuse in irrigation, and the European legislation for water reuse was established. The effluent quality met the stringent criteria for various classes of agricultural reuse, illustrating the system’s potential for sustainable water management. This wetland model presents a robust solution for water-stressed regions, ensuring environmental protection while supporting agricultural needs. The study calls for ongoing research to further refine the system for optimal, reliable wastewater treatment and water resource sustainability.展开更多
Coastal cities represented by Ningbo are directly or indirectly affected by typhoons each year. By analyzing the past three typical typhoons landing in Ningbo from 2013 to 2016, it was found that before and after the ...Coastal cities represented by Ningbo are directly or indirectly affected by typhoons each year. By analyzing the past three typical typhoons landing in Ningbo from 2013 to 2016, it was found that before and after the typhoon transit, reservoir and water treatment plant would be made by the destructive impact, including the increasing water level, water volume in a short time, and the deteriorating water quality. Among those, the water quality caused by typhoons increased the water treatment process load, the amount of water purification agents increased significantly,and the emergency response put a great pressure on the inventory of water plants. Based on the statistics and analysis of the basic parameters of the reservoir and water treatment plant during the typhoon season, the emergency management of the typhoon was divided into three situations, namely, pre-typhoon, typhoon period and post-typhoon. Thus, it is effective for the relevant practitioners of the reservoir and water plant to ensure the safe water supply during typhoon season.展开更多
Nowadays, with regard to environmental issues, proper operation of wastewater treatment plants is of particular importance that in the case of inappropriate utilization, they will cause serious problems. Processes tha...Nowadays, with regard to environmental issues, proper operation of wastewater treatment plants is of particular importance that in the case of inappropriate utilization, they will cause serious problems. Processes that exist in environmental systems and environmental engineers are dealing with them mostly have two major characteristics: they are dependent on many variables;and there are complex relationships between its components which make them very difficult to analyze. Being familiar with characteristics of industrial town effluents from various wastewater treatment units, which have high qualitative and quantitative variations and more uncertainties compared to urban wastewaters, plays very effective role in governing them. In order to achieve a better and efficient control over the operation of an industrial wastewater treatment plant, powerful mathematical tool can be used that is based on recorded data from some basic parameters of wastewater during a period of treatment plant operation. In this study, the multilayer perceptron (MLP) feed forward neural network with a hidden layer and stop training method was used to predict quality parameters of the industrial effluent. Data of this study are related to the Fajr Industrial Wastewater Treatment Plant located in Mahshahr—Iran that qualitative and quantitative characteristics of its units were used for training, calibration and evaluation of the neural model. Also, Principal Component Analysis technique was applied to modify and improve performance of generated models of neural networks. The results of this model showed good accuracy of the model in estimating qualitative pro- file of wastewater. This model facilitates evaluating the performance of each treatment plant units through comparing the results of prediction model with the standard amount of output.展开更多
The paper described the coking plant and Lurgi gasifier plant waste water types and characteristics , comparing the COD and ammonia-N level in different source of waste water in the plant.The currently maturity coking...The paper described the coking plant and Lurgi gasifier plant waste water types and characteristics , comparing the COD and ammonia-N level in different source of waste water in the plant.The currently maturity coking plant waste water treatment method was statement in the paper and analyzed the pros and cons of each method.The primary cost analysis of each type of waste water treatment was also completed in the paper.According to these analyses , recommendation was prepared for coking plant and Lurgi gasifier plant waste water treatment.展开更多
Pumping system analysis can be used together with a decision support system to provide information for efficient pumping system operation or system refurbishment and upgrading.The actual operation condition of the wat...Pumping system analysis can be used together with a decision support system to provide information for efficient pumping system operation or system refurbishment and upgrading.The actual operation condition of the water supply system needs to be ascertained.This paper will share experience by the authors in determining the actual pump performance through measurement of flow and pressure in the system.The incremental increase in pressure is achieved by varying head loss induced to the system by valve throttling.Integrating the Bernoulli’s principles of the geodetic,static and dynamic energy,and input power data will enable the analysis of energy input and output and hence arriving to pump efficiency values.This method offers the most accurate operation conditions for refurbishment systems to endure.The on-site measurements will allow the determination of the averaged actual friction coefficient which includes the effect of system deterioration and fittings conditions.This information will be used to determine the expected duty point of an upgrading system more precisely.The study highlighted the actual pump operating efficiencies for an old pumping system installation.展开更多
The aim of the present study was to investigate the effect of electromagnetic radio frequency treatment of water on the growth of pepper (Capsicum annuum) plants. For this experiment, one hundred one-week old plants w...The aim of the present study was to investigate the effect of electromagnetic radio frequency treatment of water on the growth of pepper (Capsicum annuum) plants. For this experiment, one hundred one-week old plants were divided into two groups. The first group of plants was watered with water subjected to radio frequency electromagnetic radiation from an internet router for one hour a day, while the other group was watered with tap water (control). The overall results showed changes of growth characters of plant watered with electromagnetic water. The length of pepper plants is significantly affected by the treated water, where the length of shoot was lower in plants grown under the effect of treated water (22.43 ± 7.17 cm) than those grown without treated water (28.11 ± 8.57 cm). The results revealed that the stem diameter of control plants (1.74 ± 0.39 cm) was significantly higher than that of the treated plants (1.66 ± 0.35 cm). In addition, the root length was lower in plants grown under the effect of treated water than those grown without treated water. Pepper plants watered with electromagnetic treated water exhibited marked decreases in health index, fresh and dry weight, relative water content, number of flowers and fruits/plant as well as number of seeds/fruit. In addition, the current experiment showed a significant decrease in the number of leaves, branch and flower per plant when watered with electromagnetic treated water. The results revealed that the first flowering time for plants in treated group was remarkably decelerated when compared to other plants in control group.展开更多
Water-Decision Support System (DSS) tools enhance decision-makings towards improved water supply in a given region. The rigours of manual design of the conventional water treatment plants are easily eliminated with th...Water-Decision Support System (DSS) tools enhance decision-makings towards improved water supply in a given region. The rigours of manual design of the conventional water treatment plants are easily eliminated with the use of softwares as in the case of DSS. Therefore, this paper focuses on the development of a Water-DSS for design of treatment plant in Karkala Town, Udupi District of India. A four-decade population projection was made using the baseline data of 1971 till date. The manual computation for water demand, unit operations and adjoining facilities was carried out and later coded in C-programming language for development of a DSS for easier design and process selection. Data validation was done and results from the two approaches were compared. With the C-programming technique, a decision support tool for design and process selection of drinking water treatment plant using conventional method has been developed and named Water-DSS1. The designed tool is simple, accurate, flexible, efficient and universal, easily adaptable to any similar conventional treatment plant. Water-DSS1 is thus recommended for general use in ultimately alleviating water supply challenges.展开更多
This paper studies the application of renewable energy sources in wastewater treatment plants to achieve self-sustain- ability of power. The data of wastewater treatment plant in the rural city of Toukh-EGYPT are pres...This paper studies the application of renewable energy sources in wastewater treatment plants to achieve self-sustain- ability of power. The data of wastewater treatment plant in the rural city of Toukh-EGYPT are presented as a case-study. The primary objective is to provide an entirely renewable standalone power system, which satisfies lowest possible emissions with the minimum lifecycle cost. Mass balance principle is applied on the biodegradable components in the wastewater to evaluate the volume of digester gas that is produced from sludge through anaerobic digestion process. Using digester gas as a fuel lead to study combined-heat-and-power technologies, where fuel cell is selected in order to abide by the low emissions constraint. The study assessed the electrical power obtained from fuel cell and the utilization of the exhausted heat energy for additional electrical power production using a micro-turbine. After covering the major part of load demand, the use of other renewable energy sources was studied. The strength of both solar and wind energy was determined by the case-study location. Hybrid optimization model for electric renewable (HOMER) software was used to simulate the hybrid system composed of combined-heat-and-power units, wind turbines and photovoltaic systems. Simulation results gave the best system configuration and optimum size of each component beside the detailed electrical and cost analysis of the model.展开更多
Large quantities of sludge are produced during water treatment processes. Recently, sludge has been treated as waste and disposed of in landfills, which increases the environmental burdens and the operational cost. Th...Large quantities of sludge are produced during water treatment processes. Recently, sludge has been treated as waste and disposed of in landfills, which increases the environmental burdens and the operational cost. Therefore, sludge reuse has become a significant environmental issue. In this study, adsorption of copper ions (Cu^2+) onto calcined sludge was investigated under various operational conditions (with varying temperature, Cu^2+ initial concentration, pH, and sludge dosage). The prepared sludge material was characterized with transmission electron microscopy (TEM), X-ray diffraction (XRD), dynamic light scattering (DLS), and Brunauer-Emmett-Teller (BET) surface area. The sorption capacity of sludge was directly proportional to the initial Cu^2+ concentration and inversely proportional to the sludge dosage. The optimum operational pH and solution temperature were 6.6 and 80℃, respectively. The experimental results followed a Langmuir isotherm and pseudo-first-order adsorption kinetics. Thermodynamic parameters such as activation energy, change in free energy, enthalpy, and entropy were calculated. Thermodynamic analyses indicated that the sorption of copper ions onto the calcined sludge was driven by a physical adsorption process. The prepared sludge was proven to be an excellent adsorbent material for the removal of Cu^2+ from an aqueous solution under optimum conditions.展开更多
The study aims to investigate the current extent of physicochemical parameters and heavy metal contamination in the effluent of the Jaganpur sewage treatment plant (STP), Dayalbagh, Agra India. Majority of the nearby ...The study aims to investigate the current extent of physicochemical parameters and heavy metal contamination in the effluent of the Jaganpur sewage treatment plant (STP), Dayalbagh, Agra India. Majority of the nearby farmers have access to use of STP effluent in irrigation purposes for growing major edible crops. The problems of using STP effluent for irrigation purpose, continuous water quality analysis required. To check the quality of irrigation water, substantial physicochemical parameters accordance to Indian Standards (IS-Reaffirmed 2002/2003) analysed to calculate Sodium absorption ratio (SAR) and Residual sodium carbonate (RSC). To estimate the heavy metal pollution index (HPI) and metal quality index (MQI), toxic Heavy metals such as As, Cr, Mn, Fe, Ni, Cu, Zn, Pd, Cd, Co, and B also determined in the STP effluent with an AAS and results verified with ICP-OES against certified standards. The high value of SAR (range 13 to 20) and RSC (range -10 to 11) in STP effluent exceeded the permissible limit for irrigation purpose. On the other hand, HPI and MQI values (1692.4 and 58.1, respectively) show that high metal contamination mainly due to industrial and domestic wastewater does not treat appropriately in the sewage treatment plant. Thus it is suggested that further studies are carried out on the STP effluents to improve the water quality through proper treatment. Treated wastewater used for irrigation purposes needs to analyse the contamination like heavy metals and pinpoint the pollution sources.展开更多
The air conditioning system in the Umm Al-Qura University (Albdiya Campus) was conceived to be a district cooling by a remote chilled water plant. Recently, there are two chilled water plants in the university install...The air conditioning system in the Umm Al-Qura University (Albdiya Campus) was conceived to be a district cooling by a remote chilled water plant. Recently, there are two chilled water plants in the university installed strategically to provide chilled water to all the academic and administrative buildings of the university through distribution network with total capacity approximately of 12,000 tons of refrigeration. The plants were built based on cooling towers with open water cycle as heat rejection system. Water treatment chemicals has been used to protect the cooling systems from corrosion, scaling and microbiological fouling accompanied with dissolved and suspended water impurities. Different methods are being used to determine and control the treatment chemical concentrations and system performance indicators. Traditional chemical controller has drawback of indirect measurements and set points. The purpose of this paper is to present a solution to overcome the problems of traditional and conventional chemical treatment and control sys-tems. Central cooling plant number (1) assigned to perform experimental setup using new chemical treatment technology. Advanced automatic chemical treatment controller installed on condensers (1, 2 and 3), and certain key performance indicators were selected and monitored such as chemical and water consumption, power, energy saving, and maintaining system integrity and efficiency. Satisfactory results were obtained in terms of performance and cost of operation.展开更多
The implementation of the EU-water framework directive (EU-WFD) demands a financeable and adaptable sewage treatment, creating a need for action especially in rural areas, where the “good ecological status” is often...The implementation of the EU-water framework directive (EU-WFD) demands a financeable and adaptable sewage treatment, creating a need for action especially in rural areas, where the “good ecological status” is often not reached even though the sewage works fulfill the legal minimum requirements. Therefore the construction of new, more efficient wastewater treatment plants is advisable. Due to the precarious financial situation in most rural areas, many municipalities can however not master the necessary funds for an improved waste water infrastructure. A large part of the costs would have to be shouldered by the local population in the form of additional sewage levies, leading to massive socio-economic strain. Hence, different solutions, which are tailored to the socio-economic, demographic and environmental characteristics of rural areas and fulfill the legal requirements, need to be developed. One possible approach is presented in the form of the Dirlammen case study (municipality Lautertal, Hesse, Germany). It consists of 1) biological and physicochemical analyses of the waste waters, 2) a modified eco-balance for the construction of a new sewage works and 3) socio-economic and demographic analyses of the population. It serves as a tool for the assessment of the influencing ecological, socio-economic and demographic factors on the sewage problems in rural areas. These findings can easily be transferred to other rural areas with a similar configuration and thus deliver the basis for a generally applicable approach to these problems. The results of the comprehensive analysis have shown for the municipality Dirlammen/Lautertal that the continued operation of the existing pond sewage plant is, with regards to the ecological, socio-economic and demographic points of view, preferable to the construction of a new waste water treatment plant. With regard to the sustainability principles of the sewage treatment and the objectives of the EU-WFD, existing sewage works should be operated for as long as the sewage treatment is feasible within technical and legal boundaries. With the construction of new facilities on the other hand, the expected improvement of the water quality has to be weighed against the ecological impairments caused by the construction itself. Rural waste water plans have to be developed for the long-term, taking not only the ecology into account but also the demographic change. Possible approaches in this regard could be a shift towards a decentralized waste water treatment concept and–even more important–improvements of the river morphology. But also the reduction of the diffuse pollution from agricultural sources should be considered for the development of strategies for the improvement of the ecological state. Short-term optimization measures in the existing sewage works might also improve the water quality until the long-term development plans can be implemented. In particular the challenges of the demographic change and linked with that the changing requirements for the rural waste water treatment must be addressed by any future plans. Only with the help of such a comprehensive approach the dangers of bad planning and unacceptable socio-economic burdens can be minimized.展开更多
Small WWTP (wastewater treatment plants) are frequently located, by necessity, in remote and isolated sites, which increases the difficulty of its energy supply. This paper describes a case study which is a step by ...Small WWTP (wastewater treatment plants) are frequently located, by necessity, in remote and isolated sites, which increases the difficulty of its energy supply. This paper describes a case study which is a step by step procedure concerning the evaluation of the wind potential of sites that are dependent of in-situ energy generation, as well as, on the utilization of the potential wind energy in Magoito WWTP. The adopted methodology comprised the collection of one year of in-situ wind data and its validation by comparison with historical data of more than 10 years of a nearby anemometric station. The data provided by the two anemometric stations was statistically treated and allowed the analysis of the results from the two stations. These results are promising in terms of wind availability and velocity. Finally, the study comprised the simulation of the local wind conditions for a considerable larger area in order to find the best site for locating a wind turbine.展开更多
Wastewaters from the chemical industry are usually of high-strength and may contain minor inhibitory and recalcitrant organics that are at times not readily identifiable. This paper describes the experience of a biolo...Wastewaters from the chemical industry are usually of high-strength and may contain minor inhibitory and recalcitrant organics that are at times not readily identifiable. This paper describes the experience of a biological waste water treatment plant (WWTP) processing a COD concentration of 43000 mg·L^-1 wastewater from an oxochemical manufacturing plant. Stage improvements of the plant process by dilution of the inhibitory influent using other chemical wastewater streams resulting in a synergistic process effect, and removal of inhibitory organics by phase separation via acidification, effectively achieved process optimization producing a high quality effluent. In particular, the COD removal efficiency of granular sludge based anaerobic reactors increased from 56% to 90%. The final effluent COD decreased from 250mg·L^-1 to 50mg·L^-1, consistently meeting the COD concentration of 100 mg·L^-1 regulatory discharge limit. The success of the process enhancements supports the hypothesis that long-chain quaternary carboxylic acids act as substrate inhibitors in the biological process.展开更多
<span style="font-family:Verdana;">We are confronting a new threat in the prevalence of antibiotic-resistant bacteria followed by epidemic spread in aquatic environments in metropolitan areas because d...<span style="font-family:Verdana;">We are confronting a new threat in the prevalence of antibiotic-resistant bacteria followed by epidemic spread in aquatic environments in metropolitan areas because damage from river floods is increasing remarkably in Japan due to global extreme weather. The sewer penetration rate is about 100% in Tokyo and reclaimed water from sewage treatment plants accounts for over 50% of all water in both the down- and mid-stream areas of local rivers. The water quality of these rivers, which contain microflora, seems to be seriously affected by reclaimed water. In this study, we collected water samples on July 17, 2018 and examined the behavior of antibiotic-resistant fecal coliforms in the stream of a sewage treatment plant in Tokyo. Extended-spectrum </span><i><span style="font-family:Verdana;">β</span></i><span style="font-family:Verdana;">-lactamase (ESBL)</span><span style="font-family:Verdana;">-producing fecal coliforms with encoding genes were found;the CTX-M-1, CTX-M-9, TEM, and SHV groups were found to have survived in the final effluent to the river after sterilization with sodium hypochlorite.展开更多
A metropolitan city such as Los Angeles (LA) is an ideal study site with a very high population density, and it houses at least 3 treatment plants where sewage is treated preliminarily and then progressing to tertiary...A metropolitan city such as Los Angeles (LA) is an ideal study site with a very high population density, and it houses at least 3 treatment plants where sewage is treated preliminarily and then progressing to tertiary treatment before discharging into the LA River. We will gain a better understanding of the water quality in the LA River and the nitrate load in the watershed system by examining the influence of waste water treatment plants (WWTPs). The goal of this study is to pinpoint the exact source of nitrate in the LA River using the isotope signatures. We have selected sampling locations both upstream and downstream of the WWTP. This serves to monitor nitrate levels, aiding in the assessment of treatment plant effectiveness, pinpointing nitrate pollution sources, and ensuring compliance with environmental regulations. The research explores the isotopic composition of NO3 in relation to atmospheric nitrogen and Vienna Standard Mean Ocean Water, shedding light on the contributions from various sources such as manure, sewage, soil organic nitrogen, and nitrogen fertilizers. Specifically, there is a change in the δ15NAir value between the dry and wet seasons. The isotope values in the Tillman WWTP sample changed between dry and wet seasons. Notably, the presence of nitrate originating from manure and sewage is consistent across seasons, emphasizing the significant impact of anthropogenic and agricultural activities on water quality. This investigation contributes to the broader understanding of nitrogen cycling in urban water bodies, particularly in the context of wastewater effluent discharge. The findings hold implications for water quality management and highlight the need for targeted interventions to mitigate the impact of nitrogen-containing compounds on aquatic ecosystems. Overall, the study provides a valuable framework for future research and environmental stewardship efforts aimed at preserving the health and sustainability of urban water resources. This data informs decisions regarding additional treatment or mitigation actions to safeguard downstream water quality and ecosystem health.展开更多
In Wuxi Wastewater Treatment Plant, the Anaerobic, anoxic and oxic (A2/O) process was employed to remove the nitrogen and phosphorus, which exhibited the positive results of the high removal efficiency for phosphorus ...In Wuxi Wastewater Treatment Plant, the Anaerobic, anoxic and oxic (A2/O) process was employed to remove the nitrogen and phosphorus, which exhibited the positive results of the high removal efficiency for phosphorus with a range of 67.7% to 89.9% and an average value of 78.0. The effluent of phosphorus met the national discharge standard. The removal of TN was effected by both BOD variation of influent and wastewater temperature. TN removal was in the range of 28.5% to 55.8% with an average value of 39.4%. The energy cost was 0.15 kWh(m3d)-1 or 1.35 kWh(kgBOD@d)-1. The annual average sludge production was 46.3 m3d-1, the annual average dosage for the dewatering was 40 kg d-1 .展开更多
Due to its dry climate, growing population, and overexploited groundwater, China's capital is plagued by water scarcity. Since the late 1980 s, Beijing has adopted water reuse solutions to bring relief; today, how...Due to its dry climate, growing population, and overexploited groundwater, China's capital is plagued by water scarcity. Since the late 1980 s, Beijing has adopted water reuse solutions to bring relief; today, however, the intentions of these reuse policies are often not reflected in practice. Three significant implementation gaps exist: lack of use of installed decentralized reuse systems, limited understanding of the operation of decentralized treatment plants by operators,and inadequate service of centralized reuse treatment systems. By understanding the cause,impact, and severity of these gaps, Beijing's policymakers can work to meet existing needs via a range of municipal and national policy-driven actions.展开更多
Most of developing countries suffer from decreasing and poor quality of drinking water which led to emergence of many dangerous diseases. In addition, there isn’t any methodology followed to predict and disinfect dri...Most of developing countries suffer from decreasing and poor quality of drinking water which led to emergence of many dangerous diseases. In addition, there isn’t any methodology followed to predict and disinfect drinking water by using advanced software program. Maintaining water quality in the water distribution system has become a prominent issue in the study of the water network. Residual chlorine concentration is the indicator to ensure the quality of water in the water network because it eliminates contaminants in the distribution network beginning of the treatment plant down to the consumer. In collaboration with Alexandria (Egypt) Water Company, samples were taken from El-NOZHA water plant station and El-HADARA water distribution network to know the free residual chlorine. In this paper, WaterCAD software has been used to make hydraulic analysis and calibration of residual chlorine in water distribution network to know the ideal chlorine dose that should be added at the water treatment plant and to know the areas of strength and weakness in the concentration of free residual chlorine in the water distribution network. In addition different scenarios have been found to know the free residual chlorine at the weakness areas after injecting chlorine in some junctions and the impact of a fire case or breaking in the water pipe distribution network on the residual chlorine. Results showed ensuring in the water quality in the distribution network by adding chlorine dose in water less than the existing dose which has been added in the El-NOZHA water treatment plant. It is possible to maintain the percentage of free residual chlorine concentration at different locations without relying on adding chlorine only in water treatment plant by injecting low percentage of chlorine dose in the junctions.展开更多
This paper presents a comprehensive study of spatial and temporal patterns of water chemistry (1995-2008) in the Yesilirmak River catchment in Northern Turkey. Biological oxygen demand (BOD), dissolved oxygen (DO) and...This paper presents a comprehensive study of spatial and temporal patterns of water chemistry (1995-2008) in the Yesilirmak River catchment in Northern Turkey. Biological oxygen demand (BOD), dissolved oxygen (DO) and nutrient concentrations (nitrogen and phosphorus) are variable across the catchment because the upland areas are relatively undisturbed, and the lower catchment is dominated by urban, industrial and agricultural inputs. Seasonally, high nutrient concentrations occur in winter possibly due to flushing from the soil zone. Low summer flow and reduced dilution lead to high orthophosphate concentrations. However, denitrification seems to be more significant than dilution processes and this generates low nitrate concentrations in summer. Nutrient levels since 1995 do not show a significant upward trend. The current water quality status indicates that the river system is in poor condition. The majority of sites fall in the Turkish water classification class II-III and more than half fail the EU standards because of high nutrient concentrations. In order to improve the status of water quality to achieve good chemical and ecological status, there is clearly a need to improve pollution control within the river system by installing waste water treatment plants, while keeping the agricultural pollution to a minimum in the system.展开更多
文摘In Saint-Louis, Senegal, a constructed wetland with horizontal flow reed beds (FHa and FHb) has demonstrated significant efficacy in treating municipal wastewater. Analyzing various treatment stages, the system showed only a slight temperature variation, from an influent average of 26.3°C to an effluent of 24.7°C. Electrical conductivity decreased from 1331 mS/cm to 974.5 mS/cm post-primary treatment, with suspended solids (SS) dramatically reduced from 718.9 mg/L to 5.7 mg/L in the final effluent. Biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) saw a notable decrease, from initial levels of 655.6 mg/L and 1240 mg/L to 2.3 mg/L and 71.3 mg/L, respectively. Nitrogenous compounds (N-TN) and phosphates () also decreased significantly, indicating the system’s nutrient removal capacity. Microbiological analysis revealed a reduction in fecal coliforms from 7.5 Ulog/100ml to 1.8 Ulog/100ml and a complete elimination of helminth eggs. The presence of Phragmites and Typha was instrumental in enhancing these reductions. The system’s compliance with the Senegalese standards for disposal into natural environments, WHO recommendations for unrestricted water reuse in irrigation, and the European legislation for water reuse was established. The effluent quality met the stringent criteria for various classes of agricultural reuse, illustrating the system’s potential for sustainable water management. This wetland model presents a robust solution for water-stressed regions, ensuring environmental protection while supporting agricultural needs. The study calls for ongoing research to further refine the system for optimal, reliable wastewater treatment and water resource sustainability.
基金supported by the National Science Foundation of China(NSFC)(Grant number.51438006)Priority Academic Program Development of Jiangsu Higher Education Institutions
文摘Coastal cities represented by Ningbo are directly or indirectly affected by typhoons each year. By analyzing the past three typical typhoons landing in Ningbo from 2013 to 2016, it was found that before and after the typhoon transit, reservoir and water treatment plant would be made by the destructive impact, including the increasing water level, water volume in a short time, and the deteriorating water quality. Among those, the water quality caused by typhoons increased the water treatment process load, the amount of water purification agents increased significantly,and the emergency response put a great pressure on the inventory of water plants. Based on the statistics and analysis of the basic parameters of the reservoir and water treatment plant during the typhoon season, the emergency management of the typhoon was divided into three situations, namely, pre-typhoon, typhoon period and post-typhoon. Thus, it is effective for the relevant practitioners of the reservoir and water plant to ensure the safe water supply during typhoon season.
文摘Nowadays, with regard to environmental issues, proper operation of wastewater treatment plants is of particular importance that in the case of inappropriate utilization, they will cause serious problems. Processes that exist in environmental systems and environmental engineers are dealing with them mostly have two major characteristics: they are dependent on many variables;and there are complex relationships between its components which make them very difficult to analyze. Being familiar with characteristics of industrial town effluents from various wastewater treatment units, which have high qualitative and quantitative variations and more uncertainties compared to urban wastewaters, plays very effective role in governing them. In order to achieve a better and efficient control over the operation of an industrial wastewater treatment plant, powerful mathematical tool can be used that is based on recorded data from some basic parameters of wastewater during a period of treatment plant operation. In this study, the multilayer perceptron (MLP) feed forward neural network with a hidden layer and stop training method was used to predict quality parameters of the industrial effluent. Data of this study are related to the Fajr Industrial Wastewater Treatment Plant located in Mahshahr—Iran that qualitative and quantitative characteristics of its units were used for training, calibration and evaluation of the neural model. Also, Principal Component Analysis technique was applied to modify and improve performance of generated models of neural networks. The results of this model showed good accuracy of the model in estimating qualitative pro- file of wastewater. This model facilitates evaluating the performance of each treatment plant units through comparing the results of prediction model with the standard amount of output.
文摘The paper described the coking plant and Lurgi gasifier plant waste water types and characteristics , comparing the COD and ammonia-N level in different source of waste water in the plant.The currently maturity coking plant waste water treatment method was statement in the paper and analyzed the pros and cons of each method.The primary cost analysis of each type of waste water treatment was also completed in the paper.According to these analyses , recommendation was prepared for coking plant and Lurgi gasifier plant waste water treatment.
文摘Pumping system analysis can be used together with a decision support system to provide information for efficient pumping system operation or system refurbishment and upgrading.The actual operation condition of the water supply system needs to be ascertained.This paper will share experience by the authors in determining the actual pump performance through measurement of flow and pressure in the system.The incremental increase in pressure is achieved by varying head loss induced to the system by valve throttling.Integrating the Bernoulli’s principles of the geodetic,static and dynamic energy,and input power data will enable the analysis of energy input and output and hence arriving to pump efficiency values.This method offers the most accurate operation conditions for refurbishment systems to endure.The on-site measurements will allow the determination of the averaged actual friction coefficient which includes the effect of system deterioration and fittings conditions.This information will be used to determine the expected duty point of an upgrading system more precisely.The study highlighted the actual pump operating efficiencies for an old pumping system installation.
文摘The aim of the present study was to investigate the effect of electromagnetic radio frequency treatment of water on the growth of pepper (Capsicum annuum) plants. For this experiment, one hundred one-week old plants were divided into two groups. The first group of plants was watered with water subjected to radio frequency electromagnetic radiation from an internet router for one hour a day, while the other group was watered with tap water (control). The overall results showed changes of growth characters of plant watered with electromagnetic water. The length of pepper plants is significantly affected by the treated water, where the length of shoot was lower in plants grown under the effect of treated water (22.43 ± 7.17 cm) than those grown without treated water (28.11 ± 8.57 cm). The results revealed that the stem diameter of control plants (1.74 ± 0.39 cm) was significantly higher than that of the treated plants (1.66 ± 0.35 cm). In addition, the root length was lower in plants grown under the effect of treated water than those grown without treated water. Pepper plants watered with electromagnetic treated water exhibited marked decreases in health index, fresh and dry weight, relative water content, number of flowers and fruits/plant as well as number of seeds/fruit. In addition, the current experiment showed a significant decrease in the number of leaves, branch and flower per plant when watered with electromagnetic treated water. The results revealed that the first flowering time for plants in treated group was remarkably decelerated when compared to other plants in control group.
文摘Water-Decision Support System (DSS) tools enhance decision-makings towards improved water supply in a given region. The rigours of manual design of the conventional water treatment plants are easily eliminated with the use of softwares as in the case of DSS. Therefore, this paper focuses on the development of a Water-DSS for design of treatment plant in Karkala Town, Udupi District of India. A four-decade population projection was made using the baseline data of 1971 till date. The manual computation for water demand, unit operations and adjoining facilities was carried out and later coded in C-programming language for development of a DSS for easier design and process selection. Data validation was done and results from the two approaches were compared. With the C-programming technique, a decision support tool for design and process selection of drinking water treatment plant using conventional method has been developed and named Water-DSS1. The designed tool is simple, accurate, flexible, efficient and universal, easily adaptable to any similar conventional treatment plant. Water-DSS1 is thus recommended for general use in ultimately alleviating water supply challenges.
文摘This paper studies the application of renewable energy sources in wastewater treatment plants to achieve self-sustain- ability of power. The data of wastewater treatment plant in the rural city of Toukh-EGYPT are presented as a case-study. The primary objective is to provide an entirely renewable standalone power system, which satisfies lowest possible emissions with the minimum lifecycle cost. Mass balance principle is applied on the biodegradable components in the wastewater to evaluate the volume of digester gas that is produced from sludge through anaerobic digestion process. Using digester gas as a fuel lead to study combined-heat-and-power technologies, where fuel cell is selected in order to abide by the low emissions constraint. The study assessed the electrical power obtained from fuel cell and the utilization of the exhausted heat energy for additional electrical power production using a micro-turbine. After covering the major part of load demand, the use of other renewable energy sources was studied. The strength of both solar and wind energy was determined by the case-study location. Hybrid optimization model for electric renewable (HOMER) software was used to simulate the hybrid system composed of combined-heat-and-power units, wind turbines and photovoltaic systems. Simulation results gave the best system configuration and optimum size of each component beside the detailed electrical and cost analysis of the model.
文摘Large quantities of sludge are produced during water treatment processes. Recently, sludge has been treated as waste and disposed of in landfills, which increases the environmental burdens and the operational cost. Therefore, sludge reuse has become a significant environmental issue. In this study, adsorption of copper ions (Cu^2+) onto calcined sludge was investigated under various operational conditions (with varying temperature, Cu^2+ initial concentration, pH, and sludge dosage). The prepared sludge material was characterized with transmission electron microscopy (TEM), X-ray diffraction (XRD), dynamic light scattering (DLS), and Brunauer-Emmett-Teller (BET) surface area. The sorption capacity of sludge was directly proportional to the initial Cu^2+ concentration and inversely proportional to the sludge dosage. The optimum operational pH and solution temperature were 6.6 and 80℃, respectively. The experimental results followed a Langmuir isotherm and pseudo-first-order adsorption kinetics. Thermodynamic parameters such as activation energy, change in free energy, enthalpy, and entropy were calculated. Thermodynamic analyses indicated that the sorption of copper ions onto the calcined sludge was driven by a physical adsorption process. The prepared sludge was proven to be an excellent adsorbent material for the removal of Cu^2+ from an aqueous solution under optimum conditions.
文摘The study aims to investigate the current extent of physicochemical parameters and heavy metal contamination in the effluent of the Jaganpur sewage treatment plant (STP), Dayalbagh, Agra India. Majority of the nearby farmers have access to use of STP effluent in irrigation purposes for growing major edible crops. The problems of using STP effluent for irrigation purpose, continuous water quality analysis required. To check the quality of irrigation water, substantial physicochemical parameters accordance to Indian Standards (IS-Reaffirmed 2002/2003) analysed to calculate Sodium absorption ratio (SAR) and Residual sodium carbonate (RSC). To estimate the heavy metal pollution index (HPI) and metal quality index (MQI), toxic Heavy metals such as As, Cr, Mn, Fe, Ni, Cu, Zn, Pd, Cd, Co, and B also determined in the STP effluent with an AAS and results verified with ICP-OES against certified standards. The high value of SAR (range 13 to 20) and RSC (range -10 to 11) in STP effluent exceeded the permissible limit for irrigation purpose. On the other hand, HPI and MQI values (1692.4 and 58.1, respectively) show that high metal contamination mainly due to industrial and domestic wastewater does not treat appropriately in the sewage treatment plant. Thus it is suggested that further studies are carried out on the STP effluents to improve the water quality through proper treatment. Treated wastewater used for irrigation purposes needs to analyse the contamination like heavy metals and pinpoint the pollution sources.
文摘The air conditioning system in the Umm Al-Qura University (Albdiya Campus) was conceived to be a district cooling by a remote chilled water plant. Recently, there are two chilled water plants in the university installed strategically to provide chilled water to all the academic and administrative buildings of the university through distribution network with total capacity approximately of 12,000 tons of refrigeration. The plants were built based on cooling towers with open water cycle as heat rejection system. Water treatment chemicals has been used to protect the cooling systems from corrosion, scaling and microbiological fouling accompanied with dissolved and suspended water impurities. Different methods are being used to determine and control the treatment chemical concentrations and system performance indicators. Traditional chemical controller has drawback of indirect measurements and set points. The purpose of this paper is to present a solution to overcome the problems of traditional and conventional chemical treatment and control sys-tems. Central cooling plant number (1) assigned to perform experimental setup using new chemical treatment technology. Advanced automatic chemical treatment controller installed on condensers (1, 2 and 3), and certain key performance indicators were selected and monitored such as chemical and water consumption, power, energy saving, and maintaining system integrity and efficiency. Satisfactory results were obtained in terms of performance and cost of operation.
文摘The implementation of the EU-water framework directive (EU-WFD) demands a financeable and adaptable sewage treatment, creating a need for action especially in rural areas, where the “good ecological status” is often not reached even though the sewage works fulfill the legal minimum requirements. Therefore the construction of new, more efficient wastewater treatment plants is advisable. Due to the precarious financial situation in most rural areas, many municipalities can however not master the necessary funds for an improved waste water infrastructure. A large part of the costs would have to be shouldered by the local population in the form of additional sewage levies, leading to massive socio-economic strain. Hence, different solutions, which are tailored to the socio-economic, demographic and environmental characteristics of rural areas and fulfill the legal requirements, need to be developed. One possible approach is presented in the form of the Dirlammen case study (municipality Lautertal, Hesse, Germany). It consists of 1) biological and physicochemical analyses of the waste waters, 2) a modified eco-balance for the construction of a new sewage works and 3) socio-economic and demographic analyses of the population. It serves as a tool for the assessment of the influencing ecological, socio-economic and demographic factors on the sewage problems in rural areas. These findings can easily be transferred to other rural areas with a similar configuration and thus deliver the basis for a generally applicable approach to these problems. The results of the comprehensive analysis have shown for the municipality Dirlammen/Lautertal that the continued operation of the existing pond sewage plant is, with regards to the ecological, socio-economic and demographic points of view, preferable to the construction of a new waste water treatment plant. With regard to the sustainability principles of the sewage treatment and the objectives of the EU-WFD, existing sewage works should be operated for as long as the sewage treatment is feasible within technical and legal boundaries. With the construction of new facilities on the other hand, the expected improvement of the water quality has to be weighed against the ecological impairments caused by the construction itself. Rural waste water plans have to be developed for the long-term, taking not only the ecology into account but also the demographic change. Possible approaches in this regard could be a shift towards a decentralized waste water treatment concept and–even more important–improvements of the river morphology. But also the reduction of the diffuse pollution from agricultural sources should be considered for the development of strategies for the improvement of the ecological state. Short-term optimization measures in the existing sewage works might also improve the water quality until the long-term development plans can be implemented. In particular the challenges of the demographic change and linked with that the changing requirements for the rural waste water treatment must be addressed by any future plans. Only with the help of such a comprehensive approach the dangers of bad planning and unacceptable socio-economic burdens can be minimized.
文摘Small WWTP (wastewater treatment plants) are frequently located, by necessity, in remote and isolated sites, which increases the difficulty of its energy supply. This paper describes a case study which is a step by step procedure concerning the evaluation of the wind potential of sites that are dependent of in-situ energy generation, as well as, on the utilization of the potential wind energy in Magoito WWTP. The adopted methodology comprised the collection of one year of in-situ wind data and its validation by comparison with historical data of more than 10 years of a nearby anemometric station. The data provided by the two anemometric stations was statistically treated and allowed the analysis of the results from the two stations. These results are promising in terms of wind availability and velocity. Finally, the study comprised the simulation of the local wind conditions for a considerable larger area in order to find the best site for locating a wind turbine.
文摘Wastewaters from the chemical industry are usually of high-strength and may contain minor inhibitory and recalcitrant organics that are at times not readily identifiable. This paper describes the experience of a biological waste water treatment plant (WWTP) processing a COD concentration of 43000 mg·L^-1 wastewater from an oxochemical manufacturing plant. Stage improvements of the plant process by dilution of the inhibitory influent using other chemical wastewater streams resulting in a synergistic process effect, and removal of inhibitory organics by phase separation via acidification, effectively achieved process optimization producing a high quality effluent. In particular, the COD removal efficiency of granular sludge based anaerobic reactors increased from 56% to 90%. The final effluent COD decreased from 250mg·L^-1 to 50mg·L^-1, consistently meeting the COD concentration of 100 mg·L^-1 regulatory discharge limit. The success of the process enhancements supports the hypothesis that long-chain quaternary carboxylic acids act as substrate inhibitors in the biological process.
文摘<span style="font-family:Verdana;">We are confronting a new threat in the prevalence of antibiotic-resistant bacteria followed by epidemic spread in aquatic environments in metropolitan areas because damage from river floods is increasing remarkably in Japan due to global extreme weather. The sewer penetration rate is about 100% in Tokyo and reclaimed water from sewage treatment plants accounts for over 50% of all water in both the down- and mid-stream areas of local rivers. The water quality of these rivers, which contain microflora, seems to be seriously affected by reclaimed water. In this study, we collected water samples on July 17, 2018 and examined the behavior of antibiotic-resistant fecal coliforms in the stream of a sewage treatment plant in Tokyo. Extended-spectrum </span><i><span style="font-family:Verdana;">β</span></i><span style="font-family:Verdana;">-lactamase (ESBL)</span><span style="font-family:Verdana;">-producing fecal coliforms with encoding genes were found;the CTX-M-1, CTX-M-9, TEM, and SHV groups were found to have survived in the final effluent to the river after sterilization with sodium hypochlorite.
文摘A metropolitan city such as Los Angeles (LA) is an ideal study site with a very high population density, and it houses at least 3 treatment plants where sewage is treated preliminarily and then progressing to tertiary treatment before discharging into the LA River. We will gain a better understanding of the water quality in the LA River and the nitrate load in the watershed system by examining the influence of waste water treatment plants (WWTPs). The goal of this study is to pinpoint the exact source of nitrate in the LA River using the isotope signatures. We have selected sampling locations both upstream and downstream of the WWTP. This serves to monitor nitrate levels, aiding in the assessment of treatment plant effectiveness, pinpointing nitrate pollution sources, and ensuring compliance with environmental regulations. The research explores the isotopic composition of NO3 in relation to atmospheric nitrogen and Vienna Standard Mean Ocean Water, shedding light on the contributions from various sources such as manure, sewage, soil organic nitrogen, and nitrogen fertilizers. Specifically, there is a change in the δ15NAir value between the dry and wet seasons. The isotope values in the Tillman WWTP sample changed between dry and wet seasons. Notably, the presence of nitrate originating from manure and sewage is consistent across seasons, emphasizing the significant impact of anthropogenic and agricultural activities on water quality. This investigation contributes to the broader understanding of nitrogen cycling in urban water bodies, particularly in the context of wastewater effluent discharge. The findings hold implications for water quality management and highlight the need for targeted interventions to mitigate the impact of nitrogen-containing compounds on aquatic ecosystems. Overall, the study provides a valuable framework for future research and environmental stewardship efforts aimed at preserving the health and sustainability of urban water resources. This data informs decisions regarding additional treatment or mitigation actions to safeguard downstream water quality and ecosystem health.
文摘In Wuxi Wastewater Treatment Plant, the Anaerobic, anoxic and oxic (A2/O) process was employed to remove the nitrogen and phosphorus, which exhibited the positive results of the high removal efficiency for phosphorus with a range of 67.7% to 89.9% and an average value of 78.0. The effluent of phosphorus met the national discharge standard. The removal of TN was effected by both BOD variation of influent and wastewater temperature. TN removal was in the range of 28.5% to 55.8% with an average value of 39.4%. The energy cost was 0.15 kWh(m3d)-1 or 1.35 kWh(kgBOD@d)-1. The annual average sludge production was 46.3 m3d-1, the annual average dosage for the dewatering was 40 kg d-1 .
文摘Due to its dry climate, growing population, and overexploited groundwater, China's capital is plagued by water scarcity. Since the late 1980 s, Beijing has adopted water reuse solutions to bring relief; today, however, the intentions of these reuse policies are often not reflected in practice. Three significant implementation gaps exist: lack of use of installed decentralized reuse systems, limited understanding of the operation of decentralized treatment plants by operators,and inadequate service of centralized reuse treatment systems. By understanding the cause,impact, and severity of these gaps, Beijing's policymakers can work to meet existing needs via a range of municipal and national policy-driven actions.
文摘Most of developing countries suffer from decreasing and poor quality of drinking water which led to emergence of many dangerous diseases. In addition, there isn’t any methodology followed to predict and disinfect drinking water by using advanced software program. Maintaining water quality in the water distribution system has become a prominent issue in the study of the water network. Residual chlorine concentration is the indicator to ensure the quality of water in the water network because it eliminates contaminants in the distribution network beginning of the treatment plant down to the consumer. In collaboration with Alexandria (Egypt) Water Company, samples were taken from El-NOZHA water plant station and El-HADARA water distribution network to know the free residual chlorine. In this paper, WaterCAD software has been used to make hydraulic analysis and calibration of residual chlorine in water distribution network to know the ideal chlorine dose that should be added at the water treatment plant and to know the areas of strength and weakness in the concentration of free residual chlorine in the water distribution network. In addition different scenarios have been found to know the free residual chlorine at the weakness areas after injecting chlorine in some junctions and the impact of a fire case or breaking in the water pipe distribution network on the residual chlorine. Results showed ensuring in the water quality in the distribution network by adding chlorine dose in water less than the existing dose which has been added in the El-NOZHA water treatment plant. It is possible to maintain the percentage of free residual chlorine concentration at different locations without relying on adding chlorine only in water treatment plant by injecting low percentage of chlorine dose in the junctions.
文摘This paper presents a comprehensive study of spatial and temporal patterns of water chemistry (1995-2008) in the Yesilirmak River catchment in Northern Turkey. Biological oxygen demand (BOD), dissolved oxygen (DO) and nutrient concentrations (nitrogen and phosphorus) are variable across the catchment because the upland areas are relatively undisturbed, and the lower catchment is dominated by urban, industrial and agricultural inputs. Seasonally, high nutrient concentrations occur in winter possibly due to flushing from the soil zone. Low summer flow and reduced dilution lead to high orthophosphate concentrations. However, denitrification seems to be more significant than dilution processes and this generates low nitrate concentrations in summer. Nutrient levels since 1995 do not show a significant upward trend. The current water quality status indicates that the river system is in poor condition. The majority of sites fall in the Turkish water classification class II-III and more than half fail the EU standards because of high nutrient concentrations. In order to improve the status of water quality to achieve good chemical and ecological status, there is clearly a need to improve pollution control within the river system by installing waste water treatment plants, while keeping the agricultural pollution to a minimum in the system.