The primary objective of this study was to design and size a sustainable sanitation solution for the Ndiebene Gandiol 1 school located in the eponymous commune in northern Senegal. Field investigations led to the coll...The primary objective of this study was to design and size a sustainable sanitation solution for the Ndiebene Gandiol 1 school located in the eponymous commune in northern Senegal. Field investigations led to the collection of wastewater samples. Their analysis revealed specific pollutant loads, including loads of BOD5 3.6966 kgO<sub>2</sub>/day and COD of 12.8775 kgO<sub>2</sub>/day, which were central to the design phase. Following a rigorous assessment of the existing sanitation infrastructure, constructed wetland (CWs) emerged as the most appropriate ecological solution. This system, valued for its ability to effectively remove contaminants, was tailored to the specific needs of the site. Consequently, the final design of the filter extends over 217.16 m<sup>2</sup>, divided into two cells of 108.58 m<sup>2</sup> each, with dimensions of 12.77 m in length and 8.5 m in width. The depth of the filtering medium is approximately 0.60 m, meeting the standards while ensuring maximized purification. Typha, an indigenous and prolific plant known for its purification abilities, was selected as the filtering agent. Concurrently, non-crushed gravel was chosen for its proven filtration capacity. This study is the result of a combination of scientific rigor and design expertise. It provides a holistic view of sanitation for Ndiebene Gandiol. The technical specifications and dimensions of the constructed wetland filter embody an approach that marries indepth analysis and practical application, all aimed at delivering an effective and long-lasting solution to the local sanitation challenges. By integrating precise scientific data with sanitation design expertise, this study delivers a holistic solution for Ndiebene Gandiol. The detailed dimensions and specifications of the constructed wetland filter reflect a methodology that combines meticulous analysis with practical adaptation, aiming to provide an effective and sustainable response to the challenges of rural and school sanitation in the northern region of Senegal.展开更多
The digital twins concept enhances modeling and simulation through the integration of real-time data and feedback.This review elucidates the foundational elements of digital twins,covering their concept,entities,domai...The digital twins concept enhances modeling and simulation through the integration of real-time data and feedback.This review elucidates the foundational elements of digital twins,covering their concept,entities,domains,and key technologies.More specifically,we investigate the transformative potential of digital twins for the wastewater treatment engineering sector.Our discussion highlights the application of digital twins to wastewater treatment plants(WWTPs)and sewage networks,hardware(i.e.,facilities and pipes,sensors for water quality and activated sludge,hydrodynamics,and power consumption),and software(i.e.,knowledge-based and data-driven models,mechanistic models,hybrid twins,control methods,and the Internet of Things).Furthermore,two cases are provided,followed by an assessment of current challenges in and perspectives on the application of digital twins in WWTPs.This review serves as an essential primer for wastewater engineers navigating the digital paradigm shift.展开更多
This review describes the mechanisms of natural coagulants.It provides a good understanding of the two key processes of coagulation-flocculation:adsorption and charge neutralization,as well as adsorption and bridging....This review describes the mechanisms of natural coagulants.It provides a good understanding of the two key processes of coagulation-flocculation:adsorption and charge neutralization,as well as adsorption and bridging.Various factors have influence the coagulation/flocculation process,including the effect of pH,coagulant dosage,coagulant type,temperature,initial turbidity,coagulation speed,flocculation speed,coagulation and flocculation time,settling time,colloidal particles,zeta potential,the effects of humic acids,and extraction density are explained.The bio-coagulants derived from plants are outlined.The impact of organic coagulants on water quality,focusing on their effects on the physicochemical parameters of water,heavy metals removal,and bacteriological water quality,is examined.The methods of extraction and purification of plant-based coagulants,highlighting techniques such as solvent extraction and ultrasonic extraction,are discussed.It also examines the parameters that influence these processes.The methods and principles of purification of coagulating agents,including dialysis,freeze-drying,ion exchange,electrophoresis,filtration,and centrifugation,are listed.Finally,it evaluates the sustainability of natural coagulants,focusing on the environmental,technical,and economic aspects of their use.At the end of this review,the readers should have a comprehensive understanding of the mechanisms,selection,extraction,purification,and sustainability of plant-based natural coagulants in water treatment.展开更多
[Background]The previous studies suggest that radioactive elements like Cs and Sr may adversely affect marine ecosystems and the fishing industry.Traditional treatment systems for radioactive wastewater like the Advan...[Background]The previous studies suggest that radioactive elements like Cs and Sr may adversely affect marine ecosystems and the fishing industry.Traditional treatment systems for radioactive wastewater like the Advanced Liquid Processing System(ALPS)and Kurion have faced challenges in limiting concentration and achieving safety criteria.Studies suggest potential long-term impacts on benthic organisms and seafood networks due to radioactive elements like Cs and Sr from the discharged radioactive wastewater,which may hinder post-disaster recovery and provoke economic losses in the fishing industry both domestically and internationally.A series of studies indicate that there are issues of Cs and Sr pollution migration in soil and water conservation in Fukushima.[Methods]To provide feasible solutions,the main article includes five nuclear wastewater treatment technologies,and soil and water conservation measures for different media(water and soil)were evaluated through reviewing the previous fifteen years'articles.To provide feasible solutions,the main articles,the phytoextraction technologies in Cs and Sr treatment within different land use areas were wildly analyzed(Camellia japonica,Arabidopsis halleri and other local species).[Results]1)A 99.9%removal rate for Cs^(+)and 99.5%for Sr^(2+)was achieved by the KFe[Fe(CN)_(6)]and BaSO_(4)co-precipitation method.2)For membrane filtration,Sr^(2+)and Cs^(+)were removed using metal-organic framework(MOF/graphene oxide)and ion exchange techniques using inorganic materials like titanosilicates.The absorption efficiency of membrane filtration for Sr^(2+)and Cs^(+)was at least 92%and 94%,respectively.The study analyzed soil and water conservation technologies in different land uses,river basins and catchments.3)The underground water treatment mainly were completed via the membrance technologies like reverse osmosis and Permeable Reactive Barriers(PRB)technologies.The ^(90) Sr concentration decreased 77%-91%compared to the initial concentration by PRB technology.These diverse methods offered effective strategies for radioactive wastewater treatment,especially the co-precipitation method may be feasible remediation measures to ensure ecological safety surrounding nuclear power utilizing areas.Soil and water conservation measures for soil pollution treatment mainly focused on the use of stabilizers to hinder the migration of Cs and Sr in the soil and the effects of wind erosion such as interpolyelectrolyte complexes.[Conclusions]We evaluated the pollution of Cs and Sr in the Fukushima nuclear radiation soil and water to provide solutions for the treatment of nuclear wastewater and to prevent radionuclide pollutants from migrating into the soil and water.展开更多
This study presents an assessment of wastewater ecological treatment processes utilizing a horizontal flow bio-reactor at the Ndiebene Gandiol 1 school. It primarily aims to juxtapose the filtration efficacy of two di...This study presents an assessment of wastewater ecological treatment processes utilizing a horizontal flow bio-reactor at the Ndiebene Gandiol 1 school. It primarily aims to juxtapose the filtration efficacy of two distinct vegetative cells, Vetiver and Typha, in the pursuit of sustainable wastewater management strategies for rural scholastic institutions. A synergistic approach was employed, integrating on-site surveys for site-specific insights and laboratory analyses to quantify the pollutant loads pre- and post-treatment. Our findings indicate that both Vetiver and Typha-infused filter beds significantly reduce most contaminants, with particular success in diminishing chemical oxygen demand (COD) and biological oxygen demand (BOD5). Vetiver was notable for its superior reduction of COD, achieving an average effluent concentration of 74 mg/L, in contrast to Typha’s 155 mg/L. Conversely, Typha excelled in suspended solids removal, registering 1 mg/L against Vetiver’s 3 mg/L. While both systems notably surpassed the target metrics across several indicators, including fecal coliform reduction, our results pinpoint the need for refinement in phosphate remediation. Conclusively, the study underscores the efficacy of both Vetiver and Typha systems in rural wastewater treatment contexts, with their integrative application potentially paving the way for enhanced system robustness and efficiency. The outcomes herein highlight the imperative for continued research to further hone these ecological treatment modalities, especially concerning phosphate elimination.展开更多
In Saint-Louis, Senegal, a constructed wetland with horizontal flow reed beds (FHa and FHb) has demonstrated significant efficacy in treating municipal wastewater. Analyzing various treatment stages, the system showed...In Saint-Louis, Senegal, a constructed wetland with horizontal flow reed beds (FHa and FHb) has demonstrated significant efficacy in treating municipal wastewater. Analyzing various treatment stages, the system showed only a slight temperature variation, from an influent average of 26.3°C to an effluent of 24.7°C. Electrical conductivity decreased from 1331 mS/cm to 974.5 mS/cm post-primary treatment, with suspended solids (SS) dramatically reduced from 718.9 mg/L to 5.7 mg/L in the final effluent. Biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) saw a notable decrease, from initial levels of 655.6 mg/L and 1240 mg/L to 2.3 mg/L and 71.3 mg/L, respectively. Nitrogenous compounds (N-TN) and phosphates () also decreased significantly, indicating the system’s nutrient removal capacity. Microbiological analysis revealed a reduction in fecal coliforms from 7.5 Ulog/100ml to 1.8 Ulog/100ml and a complete elimination of helminth eggs. The presence of Phragmites and Typha was instrumental in enhancing these reductions. The system’s compliance with the Senegalese standards for disposal into natural environments, WHO recommendations for unrestricted water reuse in irrigation, and the European legislation for water reuse was established. The effluent quality met the stringent criteria for various classes of agricultural reuse, illustrating the system’s potential for sustainable water management. This wetland model presents a robust solution for water-stressed regions, ensuring environmental protection while supporting agricultural needs. The study calls for ongoing research to further refine the system for optimal, reliable wastewater treatment and water resource sustainability.展开更多
[Objective] The aim was to research the influences of different formulations on oxidation resistance of PVDF hollow fiber membrane.[Method]The immersion precipitation phase inversion method was employed to make castin...[Objective] The aim was to research the influences of different formulations on oxidation resistance of PVDF hollow fiber membrane.[Method]The immersion precipitation phase inversion method was employed to make casting solution with different formulations into hollow fiber membrane.The membrane was immersed in 1% NaClO solution for testing its performance changes.[Result]The membrane made by materials with bigger molecular weight had better oxidation resistance performance;the surfactant tween-80 could increase water flux,but lead to lower rupture intension;Pore-forming agent PEG400 do better than PVP in the oxidation resistance of membrane.[Conclusion]This study will provide a good idea for the development of the PVDF membrane with high oxidation resistance.展开更多
In the current social development of our country,environmental protection has become a key content,and water treatment process is a key step to achieve environmental protection.This paper analyzes the application of w...In the current social development of our country,environmental protection has become a key content,and water treatment process is a key step to achieve environmental protection.This paper analyzes the application of whole membrane water treatment technology in environmental protection.It is hoped that this analysis can be helpful for the rational application of the whole membrane water treatment technology and the improvement of environmental protection quality.展开更多
The river water and groundwater from Lagbe town in Benin Republic were collected and analyzed for physical, chemical and microbiological parameters. The surface water samples were treated with alum, Moringa oleifera s...The river water and groundwater from Lagbe town in Benin Republic were collected and analyzed for physical, chemical and microbiological parameters. The surface water samples were treated with alum, Moringa oleifera seeds powder and the combination of alum and Moringa oleifera seeds. The jar-test essays were carried out with two water samples at initial turbidities 7.2 NTU and 14.4 NTU. The water samples analyzed are fairly mineralized (conductivity varies between 166 and 687 μS/cm), enough soft and contain the nitrate (104 mg/L for W4 sample). They are greatly polluted by pathogenic microorganisms such as Escherichia coli, Klebsiella, Enterococcus, Vibrio, Serratia. The optimal dosages of Moringa are 96 mg/L and 80 mg/L respectively. We have observed a reduction of 60% of turbidity and a substantial remove of all pathogenic microorganisms after water treatment with Moringa oleifera seeds. For the combination treatment, 93% of initial turbidity and 92% of initial concentration of organic matter in the sample E2 were eliminated. The pH remained almost constant during the treatment.展开更多
Engineered nanomaterials are used in many applications, including pollution sensors, photovoltaics, medical imaging, drug delivery and environmental remediation. Due to their numerous applications, silver nanoparticle...Engineered nanomaterials are used in many applications, including pollution sensors, photovoltaics, medical imaging, drug delivery and environmental remediation. Due to their numerous applications, silver nanoparticles (Ag NPs) are receiving a large amount of attention. Ag NPs may occur in drinking water sources either during manufacturing, consumption and/or disposal processes. This potentially leads to the presence of Ag NPs in finished drinking water, which could have public health impacts. The objective of this research was to investigate the removal of several types of stabilized Ag NPs by potable water treatment processes. Specifically, this research achieved these objectives through: 1) Synthesis of Citrate-reduced Ag NPs, Polyvinylpyrrolidone stabilized (PVP) Ag NPs and Branched polyethyleneimine stabilized (BPEI) Ag NPs, 2) Characterization of synthesized Ag NPs to determine their aggregation potential, Zeta potential profiles, (pHpzc) and obtain morphological data from SEM images, and 3) An evaluation of the efficacy of conventional water treatment processes (i.e., coagulation, flocculation, sedimentation and sand filtration) in removing stabilized Ag NPs from natural water. The three NPs were found to be stable at the nano size in natural water. Alum coagulation had no impact on the PVP and BPEI Ag NPs. Flocculation and settling were found to be key steps for removal of these NPs. The three Ag NPs were not permanently removed by means of conventional water treatment processes employed in this study.展开更多
The emulsion stability of oilfield produced water is related to the oil-water interfacial film strength and the zeta potential of the oil droplets. We investigated the effects of water treatment agents (corrosion inh...The emulsion stability of oilfield produced water is related to the oil-water interfacial film strength and the zeta potential of the oil droplets. We investigated the effects of water treatment agents (corrosion inhibitor SL-2, scale inhibitor HEDP, germicide 1227, and flocculant polyaluminium chloride PAC) on the stability of oilfield produced water. The influence of these treatment agents on oil-water interfacial properties and the mechanism of these agents acting on the oilfield produced water were studied by measuring the interfacial shear viscosity, interfacial tension and zeta electric potential. The results indicated that the scale inhibitor HEDP could increase the oil-water interfacial film strength, and it could also increase the absolute value of the zeta potential of oil droplets. HEDP played an important role in the stability of the emulsion. Polyaluminum chloride (PAC) reduced the stability of the emulsion by considerably decreasing the absolute value of the zeta potential of oil droplets. Corrosion inhibitor SL-2 and germicide 1227 could decrease the oil-water interfacial tension, whereas they had little influence on oil-water interfacial shear viscosity and oil-water interfacial electricity properties.展开更多
The biological aerated filter (BAF) was used to treat the oil-field produced water. The removal efficiency for oil, COD, BOD and suspended solids (SS) was 76.3%-80.3%, 31.6%-57.9%, 8.6.3%-96.3% and76.4%--82.7%, re...The biological aerated filter (BAF) was used to treat the oil-field produced water. The removal efficiency for oil, COD, BOD and suspended solids (SS) was 76.3%-80.3%, 31.6%-57.9%, 8.6.3%-96.3% and76.4%--82.7%, respectively when the hydraulic loading rates varied from 016m·h^-1 to 1.4m·h^-1. The greatest partof removal, for example more than 80% of COD removal, occurred on the top 100cm of the media in BAF. The kinetic .performance of BAF indicated that the relationship of BOD removal efficiency with the hydraulic loadingrates, in biological aerated filters could be described by c1/c1=l-exp(-2.44/L^0.59). This equation could be used topredict the B OD.removal efficiency at different hydraulic loading rates.展开更多
The elemental composition and bacteria attached in particles were investigated during granular activated carbon (GAC) filtration.The experimental results showed that trapped influent particles could form new,larger ...The elemental composition and bacteria attached in particles were investigated during granular activated carbon (GAC) filtration.The experimental results showed that trapped influent particles could form new,larger particles on GAC surface.The sloughing of individuals off GAC surface caused an increase in effluent particles in the size range from 5 to 25 μm.The selectivity for element removal in GAC filters caused an increasing proportion of metallic elements in the effluent particles.The distribution of molar ratio indicated a complicated composition for large particles,involving organic and inorganic substances.The organic proportion accounted for 40% of total carbon attached to the particles.Compared with dissolved carbon,there was potential for the formation of trihalomethanes by organic carbon attached to particles,especially for those with size larger than 10 μm.The pure carbon energy spectrum was found only in the GAC effluent and the size distribution of carbon fines was mainly above 10 μm.The larger carbon fines provided more space for bacterial colonization and stronger protection for attached bacteria against disinfection.The residual attached bacteria after chorine disinfection was increased to 10 2-10 3 CFU/mL within 24 hours at 25°C.展开更多
The quantitative change and size distribution of particles in the effluents from a sand filter and a granular activated carbon (GAC) filter in a drinking water treatment plant were investigated. The average total co...The quantitative change and size distribution of particles in the effluents from a sand filter and a granular activated carbon (GAC) filter in a drinking water treatment plant were investigated. The average total concentration of particles in the sand filter effluent during a filter cycle was 148 particles/mL, 27 of which were larger than 2 μm in size. The concentration in the GAC effluent (561 particles/mL) was significantly greater than that in the sand filter effluent. The concentration of particles larger than 2 μm in the GAC filter effluent reached 201 particles/mL, with the amount of particles with sizes between 2 μm and 15 μm increasing. The most probable number (MPN) of carbon fines reached 43 unit/L after six hours and fines between 0.45 μm and 8.0 μm accounted for more than 50%. The total concentration of outflowing bacteria in the GAC filter effluent, 350 CFU (colony-forming units) /mL, was greater than that in the sand filter effluent, 210 CFU/mL. The desorbed bacteria concentration reached an average of 310 CFU/mg fines. The disinfection efficiency of desorbed bacteria was lower than 40% with 1.5 mg/L of chlorine. The disinfection effect showed that the inactivation rate with 2.0 mg/L of chloramine (90%) was higher than that with chlorine (70%). Experimental results indicated that the high particle concentration in raw water and sedimentation effluent led to high levels of outflowing particles in the sand filter effluent. The activated carbon fines in the effluent accounted for a small proportion of the total particle amount, but the existing bacteria attached to carbon fines may influence the drinking water safety. The disinfection efficiency of desorbed bacteria was lower than that of free bacteria with chlorine, and the disinfection effect on bacteria attached to carbon fines with chloramine was better than that with only chlorine.展开更多
In order to remove the low turbidity present in surface water, a novel metal-polysilicate coagulant was used to treat the raw water taken from Tanjiang River in Guangdong Province. This study on the effects of Al/Fe ...In order to remove the low turbidity present in surface water, a novel metal-polysilicate coagulant was used to treat the raw water taken from Tanjiang River in Guangdong Province. This study on the effects of Al/Fe molar ratio on the performance of a complex compound formed by polysilicic acid, aluminium and ferric salt (PAFS) showed that PAFS with Al/Fe ratio of 10:3 seemed to have the best coagulation performance in removing turbidity and color. Experimental results showed that under the conditions of polymerization time of 15 d, sedimentation time of 12 min, and pH of 6?8, PAFS with Al/Fe molar ratio of 10:3 had the best coagulation efficiency and lowest residual Al concentration. The turbid- ity decreased from 23.8 NTU to 3.23 NTU and the residual Al concentration was only 0.165 mg/L in the product water. It could be speculated that colloidal impurities and particulate Al were removed by adsorption bridging and electrical neu- tralization of long chain inorganic polymer coagulants.展开更多
The coagulation process is one of the most important stages in water treatment plant, which involves many complex physical and chemical phenomena. Moreover, coagulant dosing rate is non-linearly correlated to raw wate...The coagulation process is one of the most important stages in water treatment plant, which involves many complex physical and chemical phenomena. Moreover, coagulant dosing rate is non-linearly correlated to raw water characteristics such as turbidity, conductivity, PH, temperature, etc. As such, coagulation reaction is hard or even impossible to control satisfactorily by conventional methods. Based on neural network and rule models, an expert system for determining the optimum chemical dosage rate is developed and used in a water treatment work, and the results of actual runs show that in the condition of satisfying the demand of drinking water quality, the usage of coagulant is lowered.展开更多
Catalysis and regeneration efficiency of granular activated carbon (GAC) and activated carbon fiber (ACF) were investigated in a non-equilibrium plasma water treatment reactor with a combination of pulsed streamer...Catalysis and regeneration efficiency of granular activated carbon (GAC) and activated carbon fiber (ACF) were investigated in a non-equilibrium plasma water treatment reactor with a combination of pulsed streamer discharge and GAC or ACF. The experimental results show that the degradation efficiency of methyl orange (MO) by the combined treatment can increase 22% (for GAC) and 24% (for ACF) respectively compared to pulsed discharge treatment alone, indicating that the combined treatment has a synergetic effect. The MO degradation efficiency by the combined treatment with pulsed discharge and saturated GAC or ACF can increase 12% and 17% respectively compared to pulsed discharge treatment alone. Both GAC and ACF show catalysis and the catalysis of ACF is prominent. Meanwhile, the regeneration of GAC and ACF are realized in this process. When H202 is introduced into the system, the utilization efficiency of ozone and ultraviolet light is improved and the regeneration efficiency of GAC and ACF is also increased.展开更多
A simple optical technique based on fluctuations in light transmitted through flowing suspensions has proved useful in two distinct water treatment applications. The first of these is the monitoring and control of coa...A simple optical technique based on fluctuations in light transmitted through flowing suspensions has proved useful in two distinct water treatment applications. The first of these is the monitoring and control of coagulation/flocculation processes, where information on optimum coagulant dosages as well as on the dynamics of floc formation can be derived. The method is suitable for a very wide range of particle concentrations, up to levels found in highly turbid river waters. The second application is as a very sensitive monitor of particles in filtered water. Such monitoring can help to ensure the effective removal of pathogens such as Cryptosporidium from drinking water. Brief accounts of these techniques are given, together with some examples of their use.展开更多
The effectiveness of a magnetic ion exchange resin (MIEX) for the treatment of Hongze Lake water in China was evaluated, The kinetics of natural organic matter (NOM) removal at various MIEX doses and contact time,...The effectiveness of a magnetic ion exchange resin (MIEX) for the treatment of Hongze Lake water in China was evaluated, The kinetics of natural organic matter (NOM) removal at various MIEX doses and contact time, multiple-loading experiments, impacts of MIEX prior to coagulation on coagulant demands and the effectiveness of combination of MIEX, pre-chlorination and coagulation were investigated. Kinetic experimental results show that more than 80% UV254 and 67% dissolved organic carbon (DOC) from raw water can be removed by the use of MIEX alone. 94% sulfate, 69% nitrate and 98% bromide removals are obtained after the first use of MIEX in multiple-loading experiments. It is suggested that MIEX can be loaded up to 1 250 bed volume (BV, volume ratio of tested water to resin) or more without saturation when regarding organics removal as a target. MIEX can remove organics to a greater extend than coagulation and lower the coagulant demand when combining with coagulation. Chlorination experimental results show that MIEX can remove 57% chlorine demand and 77% trihalomethane formation potential (THMFP) for raw water. Pre-chlorination followed by MIEX and coagulation can give additional organic and THMFP removals. The results suggest that MIEX provides a new method to solve thc problem algae reproduction.展开更多
Zooplankton cyclops propagates profusely in waterbody, cannot be effectively inactivated by conventional disinfection process, and becomes a troublesome drinking water treatment problem. In this work, the qualitative ...Zooplankton cyclops propagates profusely in waterbody, cannot be effectively inactivated by conventional disinfection process, and becomes a troublesome drinking water treatment problem. In this work, the qualitative and quantitative experimental studies were carried out on inactivation of zooplankton cyclops using oxidants, such as chlorine (Cl2), chlorine dioxide (ClO2), ozone (O3), hydrogen peroxide (H2O2), ozone/hydrogen peroxide (O3/H2O2), chloramines (Cl2-NH3) and potassium permanganate (KM4nO4). The influences of various factors include different oxidant dosages, organic substance contents and pH values. The results showed that currently available oxidants used all might inactivate cyclops in some extent. According to the experimental results, chlorine dioxide, ozone, ozone/hydrogen peroxide and chloramines can be selected as effective oxidants for inactivating cyclops because of their strong inactivation abilities. Then the synergic removal effects on cyclops with ozone, ozone/hydrogen peroxide pre-oxidation followed by conventional water treatment processes were investigated, The results showed that ozone and ozone/hydrogen peroxide pre-oxidation can inactivate cyclops effectively, which then can be removed thoroughly by conventional water treatment processes. Cyclops cannot appear in water after filtration with 1.65 mg/L of ozone and 6 mg/L of hydrogen peroxide, with the inactivation rate being 62% before conventional water treatment processes. Cyclops cannot appear in water after filtration with 1.8 mg/L of ozone, with the inactivation rate being 50% before conventional water treatment processes. For different oxidants, when removal rate was the best, the inactivation rate was not the same. These results may provide reference and model for actual waterworks.展开更多
文摘The primary objective of this study was to design and size a sustainable sanitation solution for the Ndiebene Gandiol 1 school located in the eponymous commune in northern Senegal. Field investigations led to the collection of wastewater samples. Their analysis revealed specific pollutant loads, including loads of BOD5 3.6966 kgO<sub>2</sub>/day and COD of 12.8775 kgO<sub>2</sub>/day, which were central to the design phase. Following a rigorous assessment of the existing sanitation infrastructure, constructed wetland (CWs) emerged as the most appropriate ecological solution. This system, valued for its ability to effectively remove contaminants, was tailored to the specific needs of the site. Consequently, the final design of the filter extends over 217.16 m<sup>2</sup>, divided into two cells of 108.58 m<sup>2</sup> each, with dimensions of 12.77 m in length and 8.5 m in width. The depth of the filtering medium is approximately 0.60 m, meeting the standards while ensuring maximized purification. Typha, an indigenous and prolific plant known for its purification abilities, was selected as the filtering agent. Concurrently, non-crushed gravel was chosen for its proven filtration capacity. This study is the result of a combination of scientific rigor and design expertise. It provides a holistic view of sanitation for Ndiebene Gandiol. The technical specifications and dimensions of the constructed wetland filter embody an approach that marries indepth analysis and practical application, all aimed at delivering an effective and long-lasting solution to the local sanitation challenges. By integrating precise scientific data with sanitation design expertise, this study delivers a holistic solution for Ndiebene Gandiol. The detailed dimensions and specifications of the constructed wetland filter reflect a methodology that combines meticulous analysis with practical adaptation, aiming to provide an effective and sustainable response to the challenges of rural and school sanitation in the northern region of Senegal.
基金supported by the National Natural Science Foundation of China(52321005,52293443,and 52230004)the Shenzhen Science and Technology Program(KQTD20190929172630447)+1 种基金the Shenzhen Key Research Project(GXWD20220817145054002)the Talent Recruitment Project of Guandong(2021QN020106).
文摘The digital twins concept enhances modeling and simulation through the integration of real-time data and feedback.This review elucidates the foundational elements of digital twins,covering their concept,entities,domains,and key technologies.More specifically,we investigate the transformative potential of digital twins for the wastewater treatment engineering sector.Our discussion highlights the application of digital twins to wastewater treatment plants(WWTPs)and sewage networks,hardware(i.e.,facilities and pipes,sensors for water quality and activated sludge,hydrodynamics,and power consumption),and software(i.e.,knowledge-based and data-driven models,mechanistic models,hybrid twins,control methods,and the Internet of Things).Furthermore,two cases are provided,followed by an assessment of current challenges in and perspectives on the application of digital twins in WWTPs.This review serves as an essential primer for wastewater engineers navigating the digital paradigm shift.
文摘This review describes the mechanisms of natural coagulants.It provides a good understanding of the two key processes of coagulation-flocculation:adsorption and charge neutralization,as well as adsorption and bridging.Various factors have influence the coagulation/flocculation process,including the effect of pH,coagulant dosage,coagulant type,temperature,initial turbidity,coagulation speed,flocculation speed,coagulation and flocculation time,settling time,colloidal particles,zeta potential,the effects of humic acids,and extraction density are explained.The bio-coagulants derived from plants are outlined.The impact of organic coagulants on water quality,focusing on their effects on the physicochemical parameters of water,heavy metals removal,and bacteriological water quality,is examined.The methods of extraction and purification of plant-based coagulants,highlighting techniques such as solvent extraction and ultrasonic extraction,are discussed.It also examines the parameters that influence these processes.The methods and principles of purification of coagulating agents,including dialysis,freeze-drying,ion exchange,electrophoresis,filtration,and centrifugation,are listed.Finally,it evaluates the sustainability of natural coagulants,focusing on the environmental,technical,and economic aspects of their use.At the end of this review,the readers should have a comprehensive understanding of the mechanisms,selection,extraction,purification,and sustainability of plant-based natural coagulants in water treatment.
基金Xiong′an New Area Science and Technology Innovation Project(2022XACX1000)。
文摘[Background]The previous studies suggest that radioactive elements like Cs and Sr may adversely affect marine ecosystems and the fishing industry.Traditional treatment systems for radioactive wastewater like the Advanced Liquid Processing System(ALPS)and Kurion have faced challenges in limiting concentration and achieving safety criteria.Studies suggest potential long-term impacts on benthic organisms and seafood networks due to radioactive elements like Cs and Sr from the discharged radioactive wastewater,which may hinder post-disaster recovery and provoke economic losses in the fishing industry both domestically and internationally.A series of studies indicate that there are issues of Cs and Sr pollution migration in soil and water conservation in Fukushima.[Methods]To provide feasible solutions,the main article includes five nuclear wastewater treatment technologies,and soil and water conservation measures for different media(water and soil)were evaluated through reviewing the previous fifteen years'articles.To provide feasible solutions,the main articles,the phytoextraction technologies in Cs and Sr treatment within different land use areas were wildly analyzed(Camellia japonica,Arabidopsis halleri and other local species).[Results]1)A 99.9%removal rate for Cs^(+)and 99.5%for Sr^(2+)was achieved by the KFe[Fe(CN)_(6)]and BaSO_(4)co-precipitation method.2)For membrane filtration,Sr^(2+)and Cs^(+)were removed using metal-organic framework(MOF/graphene oxide)and ion exchange techniques using inorganic materials like titanosilicates.The absorption efficiency of membrane filtration for Sr^(2+)and Cs^(+)was at least 92%and 94%,respectively.The study analyzed soil and water conservation technologies in different land uses,river basins and catchments.3)The underground water treatment mainly were completed via the membrance technologies like reverse osmosis and Permeable Reactive Barriers(PRB)technologies.The ^(90) Sr concentration decreased 77%-91%compared to the initial concentration by PRB technology.These diverse methods offered effective strategies for radioactive wastewater treatment,especially the co-precipitation method may be feasible remediation measures to ensure ecological safety surrounding nuclear power utilizing areas.Soil and water conservation measures for soil pollution treatment mainly focused on the use of stabilizers to hinder the migration of Cs and Sr in the soil and the effects of wind erosion such as interpolyelectrolyte complexes.[Conclusions]We evaluated the pollution of Cs and Sr in the Fukushima nuclear radiation soil and water to provide solutions for the treatment of nuclear wastewater and to prevent radionuclide pollutants from migrating into the soil and water.
文摘This study presents an assessment of wastewater ecological treatment processes utilizing a horizontal flow bio-reactor at the Ndiebene Gandiol 1 school. It primarily aims to juxtapose the filtration efficacy of two distinct vegetative cells, Vetiver and Typha, in the pursuit of sustainable wastewater management strategies for rural scholastic institutions. A synergistic approach was employed, integrating on-site surveys for site-specific insights and laboratory analyses to quantify the pollutant loads pre- and post-treatment. Our findings indicate that both Vetiver and Typha-infused filter beds significantly reduce most contaminants, with particular success in diminishing chemical oxygen demand (COD) and biological oxygen demand (BOD5). Vetiver was notable for its superior reduction of COD, achieving an average effluent concentration of 74 mg/L, in contrast to Typha’s 155 mg/L. Conversely, Typha excelled in suspended solids removal, registering 1 mg/L against Vetiver’s 3 mg/L. While both systems notably surpassed the target metrics across several indicators, including fecal coliform reduction, our results pinpoint the need for refinement in phosphate remediation. Conclusively, the study underscores the efficacy of both Vetiver and Typha systems in rural wastewater treatment contexts, with their integrative application potentially paving the way for enhanced system robustness and efficiency. The outcomes herein highlight the imperative for continued research to further hone these ecological treatment modalities, especially concerning phosphate elimination.
文摘In Saint-Louis, Senegal, a constructed wetland with horizontal flow reed beds (FHa and FHb) has demonstrated significant efficacy in treating municipal wastewater. Analyzing various treatment stages, the system showed only a slight temperature variation, from an influent average of 26.3°C to an effluent of 24.7°C. Electrical conductivity decreased from 1331 mS/cm to 974.5 mS/cm post-primary treatment, with suspended solids (SS) dramatically reduced from 718.9 mg/L to 5.7 mg/L in the final effluent. Biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) saw a notable decrease, from initial levels of 655.6 mg/L and 1240 mg/L to 2.3 mg/L and 71.3 mg/L, respectively. Nitrogenous compounds (N-TN) and phosphates () also decreased significantly, indicating the system’s nutrient removal capacity. Microbiological analysis revealed a reduction in fecal coliforms from 7.5 Ulog/100ml to 1.8 Ulog/100ml and a complete elimination of helminth eggs. The presence of Phragmites and Typha was instrumental in enhancing these reductions. The system’s compliance with the Senegalese standards for disposal into natural environments, WHO recommendations for unrestricted water reuse in irrigation, and the European legislation for water reuse was established. The effluent quality met the stringent criteria for various classes of agricultural reuse, illustrating the system’s potential for sustainable water management. This wetland model presents a robust solution for water-stressed regions, ensuring environmental protection while supporting agricultural needs. The study calls for ongoing research to further refine the system for optimal, reliable wastewater treatment and water resource sustainability.
基金Supported by Sichuan Provincial International S&T Cooperation Program(No.2008HH0012)Cooperation Research Program of Sichuan University and Hitachi Company(No.07H372)~~
文摘[Objective] The aim was to research the influences of different formulations on oxidation resistance of PVDF hollow fiber membrane.[Method]The immersion precipitation phase inversion method was employed to make casting solution with different formulations into hollow fiber membrane.The membrane was immersed in 1% NaClO solution for testing its performance changes.[Result]The membrane made by materials with bigger molecular weight had better oxidation resistance performance;the surfactant tween-80 could increase water flux,but lead to lower rupture intension;Pore-forming agent PEG400 do better than PVP in the oxidation resistance of membrane.[Conclusion]This study will provide a good idea for the development of the PVDF membrane with high oxidation resistance.
文摘In the current social development of our country,environmental protection has become a key content,and water treatment process is a key step to achieve environmental protection.This paper analyzes the application of whole membrane water treatment technology in environmental protection.It is hoped that this analysis can be helpful for the rational application of the whole membrane water treatment technology and the improvement of environmental protection quality.
文摘The river water and groundwater from Lagbe town in Benin Republic were collected and analyzed for physical, chemical and microbiological parameters. The surface water samples were treated with alum, Moringa oleifera seeds powder and the combination of alum and Moringa oleifera seeds. The jar-test essays were carried out with two water samples at initial turbidities 7.2 NTU and 14.4 NTU. The water samples analyzed are fairly mineralized (conductivity varies between 166 and 687 μS/cm), enough soft and contain the nitrate (104 mg/L for W4 sample). They are greatly polluted by pathogenic microorganisms such as Escherichia coli, Klebsiella, Enterococcus, Vibrio, Serratia. The optimal dosages of Moringa are 96 mg/L and 80 mg/L respectively. We have observed a reduction of 60% of turbidity and a substantial remove of all pathogenic microorganisms after water treatment with Moringa oleifera seeds. For the combination treatment, 93% of initial turbidity and 92% of initial concentration of organic matter in the sample E2 were eliminated. The pH remained almost constant during the treatment.
文摘Engineered nanomaterials are used in many applications, including pollution sensors, photovoltaics, medical imaging, drug delivery and environmental remediation. Due to their numerous applications, silver nanoparticles (Ag NPs) are receiving a large amount of attention. Ag NPs may occur in drinking water sources either during manufacturing, consumption and/or disposal processes. This potentially leads to the presence of Ag NPs in finished drinking water, which could have public health impacts. The objective of this research was to investigate the removal of several types of stabilized Ag NPs by potable water treatment processes. Specifically, this research achieved these objectives through: 1) Synthesis of Citrate-reduced Ag NPs, Polyvinylpyrrolidone stabilized (PVP) Ag NPs and Branched polyethyleneimine stabilized (BPEI) Ag NPs, 2) Characterization of synthesized Ag NPs to determine their aggregation potential, Zeta potential profiles, (pHpzc) and obtain morphological data from SEM images, and 3) An evaluation of the efficacy of conventional water treatment processes (i.e., coagulation, flocculation, sedimentation and sand filtration) in removing stabilized Ag NPs from natural water. The three NPs were found to be stable at the nano size in natural water. Alum coagulation had no impact on the PVP and BPEI Ag NPs. Flocculation and settling were found to be key steps for removal of these NPs. The three Ag NPs were not permanently removed by means of conventional water treatment processes employed in this study.
文摘The emulsion stability of oilfield produced water is related to the oil-water interfacial film strength and the zeta potential of the oil droplets. We investigated the effects of water treatment agents (corrosion inhibitor SL-2, scale inhibitor HEDP, germicide 1227, and flocculant polyaluminium chloride PAC) on the stability of oilfield produced water. The influence of these treatment agents on oil-water interfacial properties and the mechanism of these agents acting on the oilfield produced water were studied by measuring the interfacial shear viscosity, interfacial tension and zeta electric potential. The results indicated that the scale inhibitor HEDP could increase the oil-water interfacial film strength, and it could also increase the absolute value of the zeta potential of oil droplets. HEDP played an important role in the stability of the emulsion. Polyaluminum chloride (PAC) reduced the stability of the emulsion by considerably decreasing the absolute value of the zeta potential of oil droplets. Corrosion inhibitor SL-2 and germicide 1227 could decrease the oil-water interfacial tension, whereas they had little influence on oil-water interfacial shear viscosity and oil-water interfacial electricity properties.
基金Supported by the National Natural Science Foundation of China (No.59978020).
文摘The biological aerated filter (BAF) was used to treat the oil-field produced water. The removal efficiency for oil, COD, BOD and suspended solids (SS) was 76.3%-80.3%, 31.6%-57.9%, 8.6.3%-96.3% and76.4%--82.7%, respectively when the hydraulic loading rates varied from 016m·h^-1 to 1.4m·h^-1. The greatest partof removal, for example more than 80% of COD removal, occurred on the top 100cm of the media in BAF. The kinetic .performance of BAF indicated that the relationship of BOD removal efficiency with the hydraulic loadingrates, in biological aerated filters could be described by c1/c1=l-exp(-2.44/L^0.59). This equation could be used topredict the B OD.removal efficiency at different hydraulic loading rates.
基金supported by the National Natural Science Foundation of China (No. 50778062)the Hi-Tech Research and Development Program (863) of China (No.2006AA06Z311)
文摘The elemental composition and bacteria attached in particles were investigated during granular activated carbon (GAC) filtration.The experimental results showed that trapped influent particles could form new,larger particles on GAC surface.The sloughing of individuals off GAC surface caused an increase in effluent particles in the size range from 5 to 25 μm.The selectivity for element removal in GAC filters caused an increasing proportion of metallic elements in the effluent particles.The distribution of molar ratio indicated a complicated composition for large particles,involving organic and inorganic substances.The organic proportion accounted for 40% of total carbon attached to the particles.Compared with dissolved carbon,there was potential for the formation of trihalomethanes by organic carbon attached to particles,especially for those with size larger than 10 μm.The pure carbon energy spectrum was found only in the GAC effluent and the size distribution of carbon fines was mainly above 10 μm.The larger carbon fines provided more space for bacterial colonization and stronger protection for attached bacteria against disinfection.The residual attached bacteria after chorine disinfection was increased to 10 2-10 3 CFU/mL within 24 hours at 25°C.
基金supported by the National Natural Science Foundation of China (Grant No 50638020)the National Key High-Tech Program (863) of China (Grant No 2006AA06Z311)the Natural Science Foundation of Jiangsu Province (Grant No BK2006170)
文摘The quantitative change and size distribution of particles in the effluents from a sand filter and a granular activated carbon (GAC) filter in a drinking water treatment plant were investigated. The average total concentration of particles in the sand filter effluent during a filter cycle was 148 particles/mL, 27 of which were larger than 2 μm in size. The concentration in the GAC effluent (561 particles/mL) was significantly greater than that in the sand filter effluent. The concentration of particles larger than 2 μm in the GAC filter effluent reached 201 particles/mL, with the amount of particles with sizes between 2 μm and 15 μm increasing. The most probable number (MPN) of carbon fines reached 43 unit/L after six hours and fines between 0.45 μm and 8.0 μm accounted for more than 50%. The total concentration of outflowing bacteria in the GAC filter effluent, 350 CFU (colony-forming units) /mL, was greater than that in the sand filter effluent, 210 CFU/mL. The desorbed bacteria concentration reached an average of 310 CFU/mg fines. The disinfection efficiency of desorbed bacteria was lower than 40% with 1.5 mg/L of chlorine. The disinfection effect showed that the inactivation rate with 2.0 mg/L of chloramine (90%) was higher than that with chlorine (70%). Experimental results indicated that the high particle concentration in raw water and sedimentation effluent led to high levels of outflowing particles in the sand filter effluent. The activated carbon fines in the effluent accounted for a small proportion of the total particle amount, but the existing bacteria attached to carbon fines may influence the drinking water safety. The disinfection efficiency of desorbed bacteria was lower than that of free bacteria with chlorine, and the disinfection effect on bacteria attached to carbon fines with chloramine was better than that with only chlorine.
基金Project (No. E9825) supported by the Natural Science Foundation of Heilongjiang Province,China
文摘In order to remove the low turbidity present in surface water, a novel metal-polysilicate coagulant was used to treat the raw water taken from Tanjiang River in Guangdong Province. This study on the effects of Al/Fe molar ratio on the performance of a complex compound formed by polysilicic acid, aluminium and ferric salt (PAFS) showed that PAFS with Al/Fe ratio of 10:3 seemed to have the best coagulation performance in removing turbidity and color. Experimental results showed that under the conditions of polymerization time of 15 d, sedimentation time of 12 min, and pH of 6?8, PAFS with Al/Fe molar ratio of 10:3 had the best coagulation efficiency and lowest residual Al concentration. The turbid- ity decreased from 23.8 NTU to 3.23 NTU and the residual Al concentration was only 0.165 mg/L in the product water. It could be speculated that colloidal impurities and particulate Al were removed by adsorption bridging and electrical neu- tralization of long chain inorganic polymer coagulants.
基金This work was supported by the project 863 ofChina(No.863-511092)
文摘The coagulation process is one of the most important stages in water treatment plant, which involves many complex physical and chemical phenomena. Moreover, coagulant dosing rate is non-linearly correlated to raw water characteristics such as turbidity, conductivity, PH, temperature, etc. As such, coagulation reaction is hard or even impossible to control satisfactorily by conventional methods. Based on neural network and rule models, an expert system for determining the optimum chemical dosage rate is developed and used in a water treatment work, and the results of actual runs show that in the condition of satisfying the demand of drinking water quality, the usage of coagulant is lowered.
基金National Natural Science Foundation of China(Nos.20576079,20776159)
文摘Catalysis and regeneration efficiency of granular activated carbon (GAC) and activated carbon fiber (ACF) were investigated in a non-equilibrium plasma water treatment reactor with a combination of pulsed streamer discharge and GAC or ACF. The experimental results show that the degradation efficiency of methyl orange (MO) by the combined treatment can increase 22% (for GAC) and 24% (for ACF) respectively compared to pulsed discharge treatment alone, indicating that the combined treatment has a synergetic effect. The MO degradation efficiency by the combined treatment with pulsed discharge and saturated GAC or ACF can increase 12% and 17% respectively compared to pulsed discharge treatment alone. Both GAC and ACF show catalysis and the catalysis of ACF is prominent. Meanwhile, the regeneration of GAC and ACF are realized in this process. When H202 is introduced into the system, the utilization efficiency of ozone and ultraviolet light is improved and the regeneration efficiency of GAC and ACF is also increased.
文摘A simple optical technique based on fluctuations in light transmitted through flowing suspensions has proved useful in two distinct water treatment applications. The first of these is the monitoring and control of coagulation/flocculation processes, where information on optimum coagulant dosages as well as on the dynamics of floc formation can be derived. The method is suitable for a very wide range of particle concentrations, up to levels found in highly turbid river waters. The second application is as a very sensitive monitor of particles in filtered water. Such monitoring can help to ensure the effective removal of pathogens such as Cryptosporidium from drinking water. Brief accounts of these techniques are given, together with some examples of their use.
基金Project(2008ZX07421-002) supported by the Key National Science and Technology Project of ChinaProject(50638020) supported by the National Natural Science Foundation of China
文摘The effectiveness of a magnetic ion exchange resin (MIEX) for the treatment of Hongze Lake water in China was evaluated, The kinetics of natural organic matter (NOM) removal at various MIEX doses and contact time, multiple-loading experiments, impacts of MIEX prior to coagulation on coagulant demands and the effectiveness of combination of MIEX, pre-chlorination and coagulation were investigated. Kinetic experimental results show that more than 80% UV254 and 67% dissolved organic carbon (DOC) from raw water can be removed by the use of MIEX alone. 94% sulfate, 69% nitrate and 98% bromide removals are obtained after the first use of MIEX in multiple-loading experiments. It is suggested that MIEX can be loaded up to 1 250 bed volume (BV, volume ratio of tested water to resin) or more without saturation when regarding organics removal as a target. MIEX can remove organics to a greater extend than coagulation and lower the coagulant demand when combining with coagulation. Chlorination experimental results show that MIEX can remove 57% chlorine demand and 77% trihalomethane formation potential (THMFP) for raw water. Pre-chlorination followed by MIEX and coagulation can give additional organic and THMFP removals. The results suggest that MIEX provides a new method to solve thc problem algae reproduction.
基金Project supported by the Hi-Tech Research and Development Program (863) of China (No. 2006AA06Z311)the Postdoctoral Science Foundation of Heilongjiang Province (No. LRB05-164)the Excellent Young Teacher Encouragement Project Foundation of HIT(No. HIT2006), China
文摘Zooplankton cyclops propagates profusely in waterbody, cannot be effectively inactivated by conventional disinfection process, and becomes a troublesome drinking water treatment problem. In this work, the qualitative and quantitative experimental studies were carried out on inactivation of zooplankton cyclops using oxidants, such as chlorine (Cl2), chlorine dioxide (ClO2), ozone (O3), hydrogen peroxide (H2O2), ozone/hydrogen peroxide (O3/H2O2), chloramines (Cl2-NH3) and potassium permanganate (KM4nO4). The influences of various factors include different oxidant dosages, organic substance contents and pH values. The results showed that currently available oxidants used all might inactivate cyclops in some extent. According to the experimental results, chlorine dioxide, ozone, ozone/hydrogen peroxide and chloramines can be selected as effective oxidants for inactivating cyclops because of their strong inactivation abilities. Then the synergic removal effects on cyclops with ozone, ozone/hydrogen peroxide pre-oxidation followed by conventional water treatment processes were investigated, The results showed that ozone and ozone/hydrogen peroxide pre-oxidation can inactivate cyclops effectively, which then can be removed thoroughly by conventional water treatment processes. Cyclops cannot appear in water after filtration with 1.65 mg/L of ozone and 6 mg/L of hydrogen peroxide, with the inactivation rate being 62% before conventional water treatment processes. Cyclops cannot appear in water after filtration with 1.8 mg/L of ozone, with the inactivation rate being 50% before conventional water treatment processes. For different oxidants, when removal rate was the best, the inactivation rate was not the same. These results may provide reference and model for actual waterworks.