期刊文献+
共找到6,882篇文章
< 1 2 250 >
每页显示 20 50 100
Development and Experimental Study of Air Source Heat Pump Water Heater 被引量:2
1
作者 李海峰 蔡正云 《Meteorological and Environmental Research》 CAS 2010年第2期100-102,共3页
The principle and development prospect of air source heat pump water heat were introduced,as well as the designation of condenser (storage water tank),experimental study on installations was also carried out.The resul... The principle and development prospect of air source heat pump water heat were introduced,as well as the designation of condenser (storage water tank),experimental study on installations was also carried out.The results showed that air source heat pump water heater was superior to conventional system.Under the operation of cooling and heating,heat pump comprehensive utilization equipment could improve heating performance,reduce energy consumption,and recycle condensing heat to provide hot water. 展开更多
关键词 air source heat pump water heater China
下载PDF
Modeling and Optimization of Solar Collector Design for the Improvement of Solar-Air Source Heat Pump Building Heating System
2
作者 Jiarui Wu Yuzhen Kang Junxiao Feng 《Energy Engineering》 EI 2023年第12期2783-2802,共20页
To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an impr... To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance. 展开更多
关键词 Solar energy air source heat pump optimization model solar-air heat pump heating system
下载PDF
Research on Operation Optimization of Heating System Based on Electric Storage Coupled Solar Energy and Air Source Heat Pump
3
作者 Jingxiao Han Chuanzhao Zhang +5 位作者 LuWang ZengjunChang Qing Zhao Ying Shi JiaruiWu Xiangfei Kong 《Energy Engineering》 EI 2023年第9期1991-2011,共21页
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e... For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases. 展开更多
关键词 Electric heat storage solar energy air source heat pump multi-objective optimization method LOCH
下载PDF
Experimental study on characteristics of transcritical heat pump water heater using refrigerant HFC125
4
作者 王方 连之伟 +1 位作者 范晓伟 王凤坤 《Journal of Southeast University(English Edition)》 EI CAS 2010年第2期182-186,共5页
To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is car... To evaluate the performance of heat pumps using refrigerant HFC125,an experimental rig of a DC-inverter heat pump water heater is designed and set up,and the research on the transcritical heat pump water heater is carried out experimentally.It is found that there is a top value of the coefficient of performance(COP)when the system runs at 95 Hz of frequency.The relationships between the COP and compressor frequency,condensation pressure,evaporation pressure,condensation water temperature rise,and discharge temperature are discussed and analyzed at 95 Hz.And the COP of the HFC125 transcritical cycle is also compared with that of a R410 subcritical heat pump under the same conditions.The results indicate that there exists an optimum frequency for a better COP,and the system COP shows an increasing tendency with the decrease in condensation pressure and compressor ratio while the evaporation pressure remains invariant,and the COP decreases rapidly when cooling water temperature rises over 47.5 ℃.Compared with the R410A sub-critical cycle,the COP of HFC125 transcritical cycle significantly increases by 12% on average. 展开更多
关键词 HFC125 transcritical cycle heat pump water heater coefficient of performance(COP)
下载PDF
Experimental Study of Thermoelectric Heat Pump Water Heater with Exhaust Heat Recovery from Kitchens 被引量:4
5
作者 LIU Zhong-bing,ZHANG Ling,YANG Zhang,XU Ming,HAN Tian-he(College of Civil Engineering,Hunan University,Changsha,Hunan 410082,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期131-135,共5页
A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coeff... A new kind of thermoelectric heat pump water heater for kitchens exhaust heat recovery was presented,and its performances were investigated under different operating voltages.The experiment results show that the coefficient of performance decreases and the temperature difference between the hot and cold sides becomes larger with the increase of the operating voltage,but the heating time becomes short.The higher the temperature of water,the greater the temperature difference between the hot and cold sides,leading to a smaller coefficient of performance.Under an exhaust temperature of 36 ℃,the coefficient of performance decreases from 1.66 to 1.22 when the temperature of water increases from 28 ℃ to 46 ℃ with operating voltage 16 V.Performance tests illustrate that,compared with the conventional electrical water heaters,the new kind of thermoelectric heat pump water heater is more coefficient. 展开更多
关键词 THERMOELECTRIC heat pump KITCHENS EXHAUST water heatER COEFFICIENT of performance
下载PDF
Operating performance of novel reverse-cycle defrosting method based on thermal energy storage for air source heat pump 被引量:7
6
作者 董建锴 姜益强 +1 位作者 姚杨 张雪丹 《Journal of Central South University》 SCIE EI CAS 2011年第6期2163-2169,共7页
To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) metho... To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting. 展开更多
关键词 air source heat pump thermal energy storage phase change material reverse-cycle defrosting
下载PDF
Operation Performance of Air Source Heat Pump System for Space Heating in Tianjin 被引量:2
7
作者 赵军 陈雁 +1 位作者 曲航 李新国 《Transactions of Tianjin University》 EI CAS 2007年第2期137-141,共5页
An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the ... An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃. 展开更多
关键词 air source heat pump system(ASHPS) space heating defrosting parameter COP
下载PDF
Thermo-Economic Performance of Geothermal Driven High-Temperature Flash Tank Vapor Injection Heat Pump System:A Comparison Study
8
作者 Huashan Li Xiaoshuang Zhao +2 位作者 Sihao Huang Lingbao Wang Jiongcong Chen 《Energy Engineering》 EI 2023年第8期1817-1835,共19页
Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is... Process heating constitutes a significant share of final energy consumption in the industrial sector around the world.In this paper,a high-temperature heat pump(HTHP)using flash tank vapor injection technology(FTVI)is proposed to develop low-temperature geothermal source for industrial process heating with temperature above 100°C.With heat sink output temperatures between 120°C and 150°C,the thermo-economic performance of the FTVI HTHP system using R1234ze(Z)as refrigerant is analyzed and also compared to the single-stage vapor compression(SSVC)system by employing the developed mathematical model.The coefficient of performance(COP),exergy efficiency(ηexe),net present value(NPV)and payback period(PBP)are used as performance indicators.The results show that under the typical working conditions,the COP andηexe of FTVI HTHP system are 3.00 and 59.66%,respectively,and the corresponding NPV and PBP reach 8.13×106 CNY and 4.13 years,respectively.Under the high-temperature heating conditions,the thermo-economic performance of the FTVI HTHP system is significantly better than that of the SSVC system,and the larger the temperature lift,the greater the thermo-economic advantage of the FTVI HTHP system.Additionally,the FTVI HTHP system is more capable than the SSVC system in absorbing the financial risks associated with changes of electricity price and natural gas price. 展开更多
关键词 Geothermal water high-temperature heat pump flash tank vapor injection thermo-economic performance
下载PDF
Thermodynamic Simulation of CCP in Air-Cooled Heat Pump Unit with HFCs and CO<sub>2</sub>Trans-Critical 被引量:2
9
作者 Feihu Chen Shuguang Liao Guangcai Gong 《Journal of Power and Energy Engineering》 2018年第9期141-164,共24页
The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit ... The exergy analysis and finite time thermodynamic methods had been employed to analyze the compound condensation process (CCP). It was based on the air-cooling heat pump unit. The cooling capacity of the chiller unit is about 1 kW, and the work refrigerant is R22/R407C/R410A/CO2. The MATLAB/SIMULINK software was employed to build the simulation model. The thermodynamic simulation model is significant for the optimization of parameters of the unit, such as condensation and evaporation temperature and mass flow of the sanitary hot water and size of hot water storage tank. The COP of the CCP of R410A system is about 3% - 5% higher than the CCP of the R22 system, while CCP of the R407C system is a little lower than the CCP of R22 system. And the CCP of CO2 trans-critical system has advantage in the hot supply mode. The simulation method provided a theoretical reference for developing the production of CCP with substitute refrigerant R407C/R410A/CO2. 展开更多
关键词 air-Cooled heat pump Unit Compound Condensation Process (CCP) Exergy Analysis Method Sanitary Hot water MATLAB/SIMULINK Software Fluorine SUBSTITUTE REFRIGERANT R407C/R410A Natural REFRIGERANT CO2
下载PDF
The Efficiency Analysis of the Exhaust Air Heat Pump System 被引量:1
10
作者 Alo Mikola Teet-Andrus Koiv 《Engineering(科研)》 2014年第13期1037-1045,共9页
This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air h... This paper is based on long term parameter measurements of the exhaust air heat pumps (EAHP) system in a new built apartment building. The building was equipped with an exhaust air ventilation system and exhaust air heat pump for ventilation heat recover. The results of the measurements show that the COP of the EAHP is mainly related to the temperature graph of the heating system and the supply temperature of domestic hot water (DWH). During the measurement period some other impact factors, such as the quality of maintenance, the nighttime temperature graph of the heating system, the reduction of the exhaust air flows in case of low temperatures, mistakes in designing and low building quality, have also played a role. An analysis of energy consumption shows that in winter conditions the COP is about 3.0 and in the transition period about 3.3. The energy recovery value of the EAHP is 0.5. 展开更多
关键词 heat pump Exhaust air heat pump heat Recovery heat Requirement COP The Coefficient of Performance
下载PDF
Performance and Optimization of Air Source Heat Pump Water Heater with Cyclic Heating
11
作者 李凡 陆高锋 +3 位作者 丁云霄 郑春元 李斌 翟晓强 《Journal of Shanghai Jiaotong university(Science)》 EI 2024年第2期179-187,共9页
A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of... A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard. 展开更多
关键词 air source heat pump water heater(ASHPWH) cyclic heating MICROCHANNEL CONDENSER
原文传递
Refrigerant Control Strategies for Residential Air-Conditioning and Heat-Pump System 被引量:1
12
作者 SU Shun-yu,ZHANG Chun-zhi,CHEN Jian(College of Urban Construction,Wuhan University of Science and Technology,Wuhan,Hubei 430070,China) 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2009年第S1期91-95,共5页
This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.... This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.The void fraction in two-phase fluid region was calculated by Harms model.And based on distributed parameter model and Harms model,the refrigerant charge inventory in condenser and evaporator were calculated and analyzed in air-conditioning conditions and heat-pump conditions,respectively.The calculating results of different refrigerant mass between refrigeration and heating conditions indicate that the optimal refrigerant charge inventory in heat-pump conditions is lower than that in air-conditioning conditions.To avoid the decrease of COP due to the surplus refrigerant in heating conditions,we introduced the liquid reservoir control method and associate capillary control method.Both of them could increase the heating capacity of the air-source heat pump.The difference of optimal refrigerant charge inventory in air-conditioning and heat-pump system can be controlled by the liquid reservoir or the associate capillary. 展开更多
关键词 air-source heat pump control strategy distributed PARAMETER model CHARGE INVENTORY
下载PDF
Applicability of sewage heat pump air-conditioning system
13
作者 陈金华 刘猛 +2 位作者 刘勇 靳鸣 陈洁 《Journal of Central South University》 SCIE EI CAS 2009年第S1期183-187,共5页
A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. ... A sewage heat pump system and its application based on a project in Chongqing,China,were discussed. Based on the sewage conditions,a feasibility analysis of the sewage heat pump air conditioning system was conducted. The theoretical and quantitative calculations indicate that sewage flux in the city sewage main pipe in the project can satisfy heat exchange requirements,and taking water from the pipes has relatively small influence on the pipe net in summer and winter. The sewage heat pump air-conditioning system can save 21.5% operating cost in one year,which is energy efficient and environmentally friendly. 展开更多
关键词 SEWAGE heat pump air CONDITIONING system numerical calculation energy efficiency ENVIRONMENTAL FRIENDLINESS
下载PDF
Study on corrosion behavior of heat exchanger in water source heat pump
14
作者 刘作华 龙洋 +2 位作者 李百战 丁勇 周小霞 《化工进展》 EI CAS CSCD 北大核心 2010年第S1期695-698,共4页
Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.T... Water source heat pump is a new kind of energy saving process.One of the most common problems for water source heat pump system is the corrosion of the copper in heat exchanger.The quality of water is the key factor.The river water collected in six different places of the Yangtze River and Jialing River in Chongqing were analyzed.Various parameters(pH,coexisted ions,and hardness value)were investigated.It showed that the Yangtze River and Jialing River water was suitable for developing water source heat pump technology.Further more,aimed at the temperature and pH of the raw water's variation range in a year,the corrosion behavior of copper material was studied by controlling the water environmental condition.Corrosion rate of copper is accelerated at high temperature and lower pH value. 展开更多
关键词 water source heat pump water quality RIVER water corrosion
下载PDF
Simulation of Air Source Heat Pump with Refrigerant Injection for Heating Operation
15
作者 Liu Haibo Shao Shuangquan +1 位作者 Ma Guoyuan Fan Boyuan 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2018年第5期739-748,共10页
An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The... An air source heat pump(ASHP)with refrigerant injection is proposed for the air conditioning system of electric vehicles(EVs),especially for efficient heating in cold winter,when there is no wasted heat of engines.The simulation model is built with the framework of two-phase fluid network,where the compressor is separated as two compressors and the economizer is treated as two heat exchangers in the injection path and the main refrigerant path.With the validated simulation model,the heating performance is analyzed,and the results show that the coefficient of performance(COP)of ASHP with refrigerant injection is higher than 1.4 and the discharge temperature is less than 100℃ when the outdoor temperature is-20℃.The above performance ensures that the air conditioning system and EVs can operate normally with high efficiency even in the cold winter,which is much helpful for the practicability of EVs. 展开更多
关键词 heat pump REFRIGERANT INJECTION air CONDITIONING SIMULATION electric vehicle(EV)
下载PDF
STUDY OF THE HEAT AND HUMIDITY TRANSFER PROCESSES BETWEEN AIR AND WATER IN THE AIR WASHER
16
作者 刘刚 《Journal of China Textile University(English Edition)》 EI CAS 1997年第1期49-53,共5页
The processes of heat and humidity transfer between air and water are what to be studied mainly in the paper, we put forward some main factors which influence the processes of heat and humidity transfer in the air was... The processes of heat and humidity transfer between air and water are what to be studied mainly in the paper, we put forward some main factors which influence the processes of heat and humidity transfer in the air washer. We come to the conclusion that we can change these main factors to achieve different heat and humidity transfer processes and decide processes of heat and humidity transfer of air and water with the initial temperature of spraying water in the air washer. All these results can make things convenient for the air conditioning management. 展开更多
关键词 air WASHER the processes of heat and humidity transfer water-air ratio the initialstate of the air the initial temperature of SPRAYING water air CONDITIONING water droplet.
下载PDF
Development of Instantaneous Hot Water Dispenser Based on Water Source Heat Pump
17
作者 Satoshi Yoshida Ryozo Ooka +1 位作者 Toshiyuki Hino Kazuo Kodama 《Journal of Energy and Power Engineering》 2014年第10期1703-1711,共9页
Natural energy use is important to reduce the energy consumption of buildings. However, further reducing energy consumption with traditional systems is difficult. Therefore, we proposed a MMHP (multi-source and multi... Natural energy use is important to reduce the energy consumption of buildings. However, further reducing energy consumption with traditional systems is difficult. Therefore, we proposed a MMHP (multi-source and multi-use heat pump) to achieve higher efficiency than traditional systems. The MMHP system connects multiple heat sources such as solar heat, the ground, and air and multiple heat uses such as cooling, heating, and a hot water dispenser with a water loop. Each type of heat use side can utilize heat efficiently. However, there is a distinct lack of highly efficient hot water dispensers available. Therefore, we developed the IHWD WS (instantaneous hot water dispenser based on a water source) heat pump. In this study, we developed a prototype of the IHWD WS heat pump. The coefficient of performance of the IHWD WS heat pump was 5.2-8.5 throughout a year. When it is improved, COP (coefficient of performance) is expected to be 9.3-9.9. 展开更多
关键词 heat pumps hot water EFFICIENCY COP ground source.
下载PDF
Numerical and Experimental Study on Dynamic Performance of Heat Pump Water Heater with Electronic Expansion Valve
18
作者 Liang Zhang Xianmin Guo Weiguo Li Weihua Wang 《Journal of Energy and Power Engineering》 2012年第10期1582-1588,共7页
A series of experiments on the dynamic performance of the HPWH (heat pump water heater) unit with EXV (electronic expansion valve) under different environmental conditions were conducted. The dynamic heating capac... A series of experiments on the dynamic performance of the HPWH (heat pump water heater) unit with EXV (electronic expansion valve) under different environmental conditions were conducted. The dynamic heating capacity and COP (coefficient of performance) of the HPWH unit under different EXV openings were measured. The effects of the EXV opening on the performance of the HPWH unit were analyzed. Meanwhile, the dynamic performance of the HPWH with EXV was simulated and the results were compared with the experimental one. The experimental results indicate that during heating process, the COP increases firstly and then decreases for a fixed EXV opening, which is in good agreement with the numerical result. For different EXV openings, the COP and heating capacity of the system using larger EXV opening are superior to those using the smaller one in the initial heating stage. While in the late stage, the performance of system using smaller EXV opening is better. It is found that the system performance is improved significantly by changing the EXV opening in the different heating period and the average COP of the HPWH system is increased by 7.6%. 展开更多
关键词 heat pump water heater electronic expansion valve experimental investigation simulation.
下载PDF
The Development Trend of Heat Pump Air Conditioning in Electric Vehicle
19
作者 Qin Xiao-dong 《课程教育研究(学法教法研究)》 2016年第23期2-3,共2页
下载PDF
Practice and analysis of recycling non-drinking water from air-condition and reverse-osmosis system into rainwater collection system 被引量:2
20
作者 王小红 邵煜然 王靖华 《Journal of Southeast University(English Edition)》 EI CAS 2014年第2期169-174,共6页
This paper is based on the rainwater collection project in the retrofit of the Dongyi teaching block in Zhejiang University Xixi Campus.The analysis incorporates the local meteorological data, recycling water utilizat... This paper is based on the rainwater collection project in the retrofit of the Dongyi teaching block in Zhejiang University Xixi Campus.The analysis incorporates the local meteorological data, recycling water utilization, and precipitation adjustment.The rainwater collection system in this program also adds the condensation water from the heating, ventilation and air conditioning ( HVAC) system and the concentration from the reverse-osmosis system used for watering greens and supplying waterscapes.By calculating, the quantity of the HVAC condensation water in summer is 3.48 m3/d, and the quantity of the reverse-osmosis concentrated water is 198 to 396 L/d.This method solves the water shortage caused by high evaporation in summer and low precipitation in winter.Supported by empirical monitoring data, the proposed method significantly increases the economic efficiency of the system during the summer period. 展开更多
关键词 rainwater collection heating ventilation and air conditioning condensation water precipitation analysis reverse-osmosis concentrated water
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部