期刊文献+
共找到1,280篇文章
< 1 2 64 >
每页显示 20 50 100
Design of Balanced Reactor Welded with Water-Cooled Aluminum Busbars 被引量:1
1
作者 陈鹏 傅鹏 宋执权 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第2期242-245,共4页
A new process of welding aluminum water-cooled busbars is proposed, It can not only reduce the weight and cost, but also improve the dynamic and thermal stability. Furthermore~ both finite element method analysis and ... A new process of welding aluminum water-cooled busbars is proposed, It can not only reduce the weight and cost, but also improve the dynamic and thermal stability. Furthermore~ both finite element method analysis and a prototype test testify the advantages of the design which is not limited by load current and provides a new approach for water-cooled reactors. 展开更多
关键词 water-cooled aluminum busbars dynamic stability thermal stability
下载PDF
Analysis and optimization of heat loss for water-cooled furnace roller 被引量:1
2
作者 李勇 李家栋 +3 位作者 刘宇佳 侯帅 王昭东 王国栋 《Journal of Central South University》 SCIE EI CAS 2013年第8期2158-2164,共7页
A heat transfer model of furnace roller cooling process was established based on analysis of furnace roller's structure. The complicated model was solved with iteration planning algorithm based on Newton search. The ... A heat transfer model of furnace roller cooling process was established based on analysis of furnace roller's structure. The complicated model was solved with iteration planning algorithm based on Newton search. The model is proved logical and credible by comparing calculated results and measured data. Then, the relationship between water flow velocity, inlet water temperature, furnace temperature and roller cross section temperature, outlet water temperature, water temperature rise, cooling water heat absorption was studied. The conclusions and recommendations are mainly as follows: l) Cooling water temperature rise decreases with the increase of water flow velocity, but it has small relationship with inlet water temperature; 2) In order to get little water scale, inlet water temperature should be controlled below 30 ℃. 3) The cooling water flow velocity should be greater than critical velocity. The critical velocity is 0.07 m/s and water flow velocity should be controlled within 0.4-0.8 m/s. Within this velocity range, water cooling efficiency is high and water temperature rise is little. If cooling water velocity increases again, heat loss will increase, leading to energy wasting. 展开更多
关键词 furnace roller water-cooled furnace heat loss OPTIMIZATION CONTROL
下载PDF
Numerical Simulation on Subcooled Boiling Heat Transfer Characteristics of Water-Cooled W/Cu Divertors 被引量:2
3
作者 韩乐 常海萍 +1 位作者 张镜洋 许铁军 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第4期347-352,共6页
In order to realize safe and stable operation of a water-cooled W/Cu divertor under high heating condition,the exact knowledge of its subcooled boiling heat transfer characteristics under different design parameters i... In order to realize safe and stable operation of a water-cooled W/Cu divertor under high heating condition,the exact knowledge of its subcooled boiling heat transfer characteristics under different design parameters is crucial.In this paper,subcooled boiling heat transfer in a water-cooled W/Cu divertor was numerically investigated based on computational fluid dynamic(CFD).The boiling heat transfer was simulated based on the Euler homogeneous phase model,and local differences of liquid physical properties were considered under one-sided high heating conditions.The calculated wall temperature was in good agreement with experimental results,with the maximum error of 5%only.On this basis,the void fraction distribution,flow field and heat transfer coefficient(HTC)distribution were obtained.The effects of heat flux,inlet velocity and inlet temperature on temperature distribution and pressure drop of a water-cooled W/Cu divertor were also investigated.These results provide a valuable reference for the thermal-hydraulic design of a water-cooled W/Cu divertor. 展开更多
关键词 water-cooled W/Cu divertor subcooled boiling heat transfer characteristic numerical calculation
下载PDF
Preparation of Al-Zn-Mg-Cu alloy semisolid slurry through a water-cooled serpentine pouring channel
4
作者 Wen-zhi Zhu Wei-min Mao +2 位作者 Qing-song Wei Chen Hui Yu-sheng Shi 《China Foundry》 SCIE 2019年第1期31-39,共9页
The semisolid slurry of Al-Zn-Mg-Cu alloy was prepared through a self-designed water-cooled copper serpentine pouring channel(WSPC) machine. Influences of pouring temperature, the number of turns and the cooling water... The semisolid slurry of Al-Zn-Mg-Cu alloy was prepared through a self-designed water-cooled copper serpentine pouring channel(WSPC) machine. Influences of pouring temperature, the number of turns and the cooling water flow rate on the microstructure of the semisolid Al-Zn-Mg-Cu alloy slurry were investigated. The results show that the semisolid Al-Zn-Mg-Cu alloy slurry with satisfactory quality can be generated by the WSPC when the pouring temperature is in the range between 680 ℃ and 700 ℃. At a given pouring temperature, the average grain size of primary α-Al decreases and the shape factor increases with the increase of the number of turns. When the cooling water flow rate is 450 L·h^(-1), the obtained semisolid slurry is optimal. During the preparation of the semisolid Al-Zn-Mg-Cu alloy slurry with low superheat pouring, the alloy melt has mixed inhibition and convection flow characteristics by "self-stirring". When the alloy melt flows through the serpentine channel, the chilling effect of the inner wall of the channel, the convection and mixed inhibition of the alloy melt greatly promote the heterogeneous nucleation and grain segregation. This effect destroys the dendrite growth mode under traditional solidification conditions, and the primary nuclei gradually evolve into spherical or nearspherical grains. 展开更多
关键词 Al-Zn-Mg-Cu Alloy SEMISOLID slurry water-cooled SERPENTINE CHANNEL primary α-Al
下载PDF
Optimization of the Water-Cooled Structure for the Divertor Plates in EAST Based on an Orthogonal Theory
5
作者 李磊 姚达毛 +3 位作者 刘常乐 周自波 曹磊 梁超 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第5期435-440,共6页
An orthogoual experimental scheme was designed for optimizing a water-cooled structure of the divertor plate. There were three influencing factors: the radius R of the water- cooled pipe, and the pipe spacing L1 and ... An orthogoual experimental scheme was designed for optimizing a water-cooled structure of the divertor plate. There were three influencing factors: the radius R of the water- cooled pipe, and the pipe spacing L1 and L3. The influence rule of different factors on the cooling effect and thermal stress of the plate were studied, for which the influence rank was respectively R 〉 L1 〉 L3 and L3 〉 R 〉 L1. The highest temperature value decreased when R and L1 increased~ and the maximum thermal stress value dropped when R, L1 and L3 increased. The final optimized results can be summarized as: R equals 6 mm or 7 mm, L1 equals 19 mm, and L3 equals 20 mm. Compared with the initial design, the highest temperature value had a small decline~ and the maximum thermal stress value dropped by 19~ to 24~. So it was not ideal to improve the cooling effect by optimizing the geometry sizes of the water-cooled structure, even worse than increasing the flow speed, but it was very effective for dropping the maximum thermal stress value. The orthogoaal experimental method reduces the number of experiments by 80%, and thus it is feasible and effective to optimize the water-cooled structure of the divertor plate with the orthogonal theory. 展开更多
关键词 orthogonal theory divertor plate water-cooled structure cooling effect thermal stress OPTIMIZATION
下载PDF
Analysis of surface cracking in water-cooled rolls and heat transfer between furnace chamber and rolls in a direct flame furnace
6
作者 LIU Yimin LIU Huafei LI Jun 《Baosteel Technical Research》 CAS 2015年第1期51-56,共6页
In the direct fired furnace of a continuous annealing line, seal rolls are susceptible to deformation that leads to surface defects of steel strips. According to failure analysis, the reasons include improper structur... In the direct fired furnace of a continuous annealing line, seal rolls are susceptible to deformation that leads to surface defects of steel strips. According to failure analysis, the reasons include improper structural design and heat imbalance. An improved design has been proposed to reduce stress concentration and thermal radiation. A heat transfer model has been employed to determine the proper water flow rate for roll cooling. Industrial application proves that seal rolls with the new design has less deformation and longer service life. 展开更多
关键词 water-cooled rolls heat transfer model DEFORMATION
下载PDF
Fully Immersing Water-Cooled Radial Slab Laser and its Incoherent Beam Combination
7
作者 田兆硕 苗杰光 +2 位作者 徐志敬 曲婷 付石友 《Chinese Physics Letters》 SCIE CAS CSCD 2015年第12期58-61,共4页
A novel scheme of fully immersing water cooling is proposed for a Nd:glass radial slab laser. The slab medium is entirely immersed in the circulating water Ailing the pumping cavity, which enables much lower temperat... A novel scheme of fully immersing water cooling is proposed for a Nd:glass radial slab laser. The slab medium is entirely immersed in the circulating water Ailing the pumping cavity, which enables much lower temperature and reasonably smaller thermal gradient in the slab medium. The radial slab is symmetrically and synchronously pumped by eight flash lamps, and produces multi-output beams with a total energy of 469md. Incoherent beam combination property of the multi-output beams is also investigated. The approach suggested here provides a way of scaling the slab lasers to much higher output levels and also a convenience for beam combinations. 展开更多
关键词 Fully Immersing water-cooled Radial Slab Laser and its Incoherent Beam Combination ND
下载PDF
The Corrected Simulation Method of Critical Heat Flux Prediction for Water-Cooled Divertor Based on Euler Homogeneous Model
8
作者 张镜洋 韩乐 +2 位作者 常海萍 刘楠 许铁军 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第2期190-196,共7页
An accurate critical heat flux(CHF) prediction method is the key factor for realizing the steady-state operation of a water-cooled divertor that works under one-sided high heating flux conditions.An improved CHF pre... An accurate critical heat flux(CHF) prediction method is the key factor for realizing the steady-state operation of a water-cooled divertor that works under one-sided high heating flux conditions.An improved CHF prediction method based on Euler's homogeneous model for flow boiling combined with realizable k-ε model for single-phase flow is adopted in this paper in which time relaxation coefficients are corrected by the Hertz-Knudsen formula in order to improve the calculation accuracy of vapor-liquid conversion efficiency under high heating flux conditions.Moreover,local large differences of liquid physical properties due to the extreme nonuniform heating flux on cooling wall along the circumference direction are revised by formula IAPWSIF97.Therefore,this method can improve the calculation accuracy of heat and mass transfer between liquid phase and vapor phase in a CHF prediction simulation of water-cooled divertors under the one-sided high heating condition.An experimental example is simulated based on the improved and the uncorrected methods.The simulation results,such as temperature,void fraction and heat transfer coefficient,are analyzed to achieve the CHF prediction.The results show that the maximum error of CHF based on the improved method is 23.7%,while that of CHF based on uncorrected method is up to 188%,as compared with the experiment results of Ref.[12].Finally,this method is verified by comparison with the experimental data obtained by International Thermonuclear Experimental Reactor(ITER),with a maximum error of 6% only.This method provides an efficient tool for the CHF prediction of water-cooled divertors. 展开更多
关键词 water-cooled divertor critical heat flux numerical simulation Euler homogeneous model
下载PDF
Improvement of microstructure and mechanical properties of Al−Cu−Li−Mg−Zn alloys through water-cooling centrifugal casting technique
9
作者 Qing-bo YANG Wen-jing SHI +4 位作者 Wen LIU Miao WANG Wen-bo WANG Li-na JIA Hu ZHANG 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2024年第11期3486-3503,共18页
The microstructure and mechanical properties of as-cast Al−Cu−Li−Mg−Zn alloys fabricated by conventional gravity casting and centrifugal casting techniques combined with rapid solidification were investigated.Experime... The microstructure and mechanical properties of as-cast Al−Cu−Li−Mg−Zn alloys fabricated by conventional gravity casting and centrifugal casting techniques combined with rapid solidification were investigated.Experimental results demonstrated that compared with the gravity casting technique,the water-cooling centrifugal casting technique significantly reduces porosity,refinesα(Al)grains and secondary phases,modifies the morphology of secondary phases,and mitigates both macro-and micro-segregation.These improvements arise from the synergistic effects of the vigorous backflow,centrifugal field,vibration and rapid solidification.Porosity and coarse plate-like Al13Fe4/Al7Cu2Fe phase result in the fracture before the gravity-cast alloy reaches the yield point.The centrifugal-cast alloy,however,exhibits an ultra-high yield strength of 292.0 MPa and a moderate elongation of 6.1%.This high yield strength is attributed to solid solution strengthening(SSS)of 225.3 MPa,and grain boundary strengthening(GBS)of 35.7 MPa.Li contributes the most to SSS with a scaling factor of 7.9 MPa·wt.%^(-1).The elongation of the centrifugal-cast alloy can be effectively enhanced by reducing the porosity and segregation behavior,refining the microstructure and changing the morphology of secondary phases. 展开更多
关键词 Al−Cu−Li−Mg−Zn alloy water-cooling centrifugal casting microstructure mechanical properties segregation behavior
下载PDF
Creation and Development of Turbo-generators with Water-Cooled Stator and Rotor Windings in Shanghai Electrical Machinery Mfg Works
10
作者 Wang GengShanghai Electrical Machinery Mfg. Works 《Electricity》 1996年第1期19-22,共4页
1. An Overview of Manufacture and Operation A turbine generator utilizing a new technology of electrical machinery industry, i.e. the windings of its stator and rotor all being inner water-cooled, was first successful... 1. An Overview of Manufacture and Operation A turbine generator utilizing a new technology of electrical machinery industry, i.e. the windings of its stator and rotor all being inner water-cooled, was first successfully created in China and was known afterwards as a turbine generator with watercooled stator and rotor windings (Abbrev, TGWSR). The teachers from Zhejiang University came to Shanghai between 展开更多
关键词 Creation and Development of Turbo-generators with water-cooled Stator and Rotor Windings in Shanghai Electrical Machinery Mfg Works
下载PDF
COMPUTATIONAL FLUID DYNAMICS RESEARCH ON PRESSURE LOSS OF CROSS-FLOW PERFORATED MUFFLER 被引量:15
11
作者 HU Xiaodong ZHOU Yiqi +2 位作者 FANG Jianhua MAN Xiliang ZHAO Zhengxu 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2007年第2期88-93,共6页
The pressure loss of cross-flow perforated of physical modeling, simulation and data processing. muffler has been computed with the procedure Three-dimensional computational fluid dynamics (CFD) has been used to inv... The pressure loss of cross-flow perforated of physical modeling, simulation and data processing. muffler has been computed with the procedure Three-dimensional computational fluid dynamics (CFD) has been used to investigate the relations of porosities, flow velocity and diameter of the holes with the pressure loss. Accordingly, some preliminary results have been obtained that pressure loss increases with porosity descent as nearly a hyperbolic trend, rising flow velocity of the input makes the pressure loss increasing with parabola trend, diameter of holes affects little about pressure loss of the muffler. Otherwise, the holes on the perforated pipes make the air flow gently and meanly, which decreases the air impact to the wall and pipes in the muffler. A practical perforated muffler is used to illustrate the available of this method for pressure loss computation, and the comparison shows that the computation results with the method of CFD has reference value for muffler design. 展开更多
关键词 Perforated muffler Pressure loss Computational fluid dynamics (CFD) Porosity Flow velocity
下载PDF
PREDICTION OF ACOUSTIC PERFORMANCE IN EXPANSION CHAMBER MUFFLERS WITH MEAN FLOW BY FINITE ELEMENT METHOD 被引量:4
12
作者 Liu YadongLi CongxinRuan XueyuNational Die & Mold CAD EngineeringResearch Center,Shanghai Jiaotong University,Shanghai 200030, China 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2003年第3期292-295,304,共5页
The equation of wave propagation in a circular chamber with mean flow is obtained. Computational solution based on finite element method is employed to determine the transmission loss of expansive chamber. The effect ... The equation of wave propagation in a circular chamber with mean flow is obtained. Computational solution based on finite element method is employed to determine the transmission loss of expansive chamber. The effect of the mean flow and geometry (length of expansion chamber and expansion ratio)on acoustic attenuation performance is discussed, the predicted values of transmission loss of expansion chamber without and with mean flow are compared with those reported in the literature and they agree well. The accuracy of the prediction of transmission loss implies that finite element approximations are applicable to a lot of practical applications. 展开更多
关键词 Wave equation Finite element method Exhaust mufflers Acoustic characteristics
下载PDF
Flow Field and Temperature Field of Water-Cooling-Type Magnetic Coupling 被引量:2
13
作者 Lei Wang Zhenyuan Jia +1 位作者 Yuqin Zhu Li Zhang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2019年第4期61-72,共12页
At present, the water-cooling simulation of the water-cooled magnetic coupler is based on the water-cooled motor and the hydraulic coupler, which cannot accurately characterize the temperature distribution of the rota... At present, the water-cooling simulation of the water-cooled magnetic coupler is based on the water-cooled motor and the hydraulic coupler, which cannot accurately characterize the temperature distribution of the rotating watercooled coupling of the coupler. Focusing on rotating water cooling radiating, the present paper proposes simulating the water cooling temperature field as well as the flow field through the method of combining fluid-solid coupled heat transfer and MRF(Multiphase Reference Frame). In addition, taking an 800 kW magnetic coupling as an example, the paper optimizes the shape, number, cooling water inlet speed? and so on? of the cooling channel. Considering factors such as the complete machine’s temperature, and drag torque, it is proved that the cooling e ect is best when there are 36 involute curved channels and when the inlet speed is 3 m/s. Further, through experiments, the actual temperature values at six di erent positions when 50 kW and 70 kW thermal losses di er are measured. The measured values agree with the simulation results, proving the correctness of the proposed method. Further, data have been collected during the entire experimental procedure? and the variation in the coupling’s temperature is analyzed in depth, with the objective of laying a foundation for the estimation of the inner temperature rise as well as for the optimization of the structural design. 展开更多
关键词 water-cooling MAGNETIC COUPLING Fluid-solid COUPLING Channel Three-dimensional TEMPERATURE FIELD
下载PDF
Theoretical Calculation and Analysis of Muffler Based on Multilayer Sound Absorbing Material 被引量:2
14
作者 ZHU Congyun LIU Rongji 《Journal of Donghua University(English Edition)》 CAS 2022年第1期40-54,共15页
The multilayer impedance composite sound absorption structure of the new muffler is proposed by combining the microporous plate structure with the resonant sound absorption structure of the porous material.Firstly,the... The multilayer impedance composite sound absorption structure of the new muffler is proposed by combining the microporous plate structure with the resonant sound absorption structure of the porous material.Firstly,the acoustic impedance and acoustic absorption coefficient of the new muffler structure are calculated by acoustic electric analogy method,and then the noise attenuation is calculated.When the new muffler structure parameters change,the relationship among the noise frequency,the sound absorption coefficient and the noise attenuation is calculated by using MATLAB.Finally,the calculated results are compared with the experimental data to verify the correctness of the theoretical calculation.The variation of resonance peak,resonance frequency and attenuation band width of each structural parameter is analyzed by the relation curve.The conclusion shows that it is feasible to use multilayer sound absorbing materials as the body structure of the new muffler.And the influence relationship between the change of various parameters of the sound absorption structure with the sound absorption coefficient and noise attenuation is obtained. 展开更多
关键词 muffler micro-perforated plate multilayer sound absorbing material sound absorption coefficient noise attenuation
下载PDF
DEVELOPMENT OF SINGLE-PHASED WATER-COOLING RADIATOR FOR COMPUTER CHIP 被引量:4
15
作者 ZENG Ping CHENG Guangming +3 位作者 LIU Jiulong YANG Zhigang SUN Xiaofeng PENG Taijiang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2007年第2期77-81,共5页
In order to cool computer chip efficiently with the least noise, a single phase water-cooling radiator for computer chip driven by piezoelectric pump with two parallel-connection chambers is developed. The structure a... In order to cool computer chip efficiently with the least noise, a single phase water-cooling radiator for computer chip driven by piezoelectric pump with two parallel-connection chambers is developed. The structure and work principle of this radiator is described. Material, processing method and design principles of whole radiator are also explained. Finite element analysis (FEA) software, ANSYS, is used to simulate the heat distribution in the radiator. Testing equipments for water-cooling radiator are also listed. By experimental tests, influences of flowrate inside the cooling system and fan on chip cooling are explicated. This water-cooling radiator is proved more efficient than current air-cooling radiator with comparison experiments. During cooling the heater which simulates the working of computer chip with different power, the water-cooling radiator needs shorter time to reach lower steady temperatures than current air-cooling radiator. 展开更多
关键词 Computer chip water-cooling Piezoelectric pump Radiator ANSYS simulation Simulative heater
下载PDF
Mathematical model on heat transfer of water-cooling steel-stick bottom electrode of DC electric arc furnace 被引量:1
16
作者 HaiXu XiaoLiu 《Journal of University of Science and Technology Beijing》 CSCD 2002年第5期338-342,共5页
For predicting and controlling the melted depth of bottomelectrode during the process of steelmaking, the water-cooling steel-stick electrode is taken as an example, to analyze the process ofheat transfer, then 3D mat... For predicting and controlling the melted depth of bottomelectrode during the process of steelmaking, the water-cooling steel-stick electrode is taken as an example, to analyze the process ofheat transfer, then 3D mathematical model by control capacity methodis built. At the same time, the measurement on the melted depth ofbottom electrode is conducted which verified the correctness of thebuilt mathematical model. On the base of verification, all kinds ofkey parameters are calculated through the application and a series ofresults are simulated. Finally, the optimum parameters are found andthe service life of bottom electrode is prolonged. 展开更多
关键词 DC electric arc furnace water-cooling steel-stick electrode MATHEMATICALMODEL heat transfer
下载PDF
A novel multi-cavity Helmholtz muffler
17
作者 Han-Bo Shao Huan He +1 位作者 Yan Chen Guo-Ping Chen 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第5期150-157,共8页
A novel multi-cavity Helmholtz muffler is proposed. The multi-cavity Helmholtz muffler is composed of steel structures and silicone membranes. With suitable construction, the Helmholtz muffler can be designed to exhib... A novel multi-cavity Helmholtz muffler is proposed. The multi-cavity Helmholtz muffler is composed of steel structures and silicone membranes. With suitable construction, the Helmholtz muffler can be designed to exhibit negative mass density in low frequency, and the muffling frequency can be adjusted when we change the internal structure of the cavity,which will be very attractive for noise control. In this paper, we investigate the influence of the membranes and the cavities on noise reduction characteristics with theoretical calculations and simulations. The results show that the numbers of membranes and the volumes of the cavities can have a great effect on the position of the muffling frequency. The number of cavities can have a great effect on the width of the muffling frequency(reduce the noise by 10 dB). With different combinations of the membranes and cavities, we can get different muffling frequencies, which can meet different muffling demands in practical applications and is more flexible than the traditional Helmholtz cavity. 展开更多
关键词 MULTI-CAVITY HELMHOLTZ muffler NEGATIVE MASS DENSITY noise reduction
下载PDF
Research on Measurement Method of Muffler Performance under High Temperature and High-Speed Airflow Conditions
18
作者 Liping Xie Chihua Lu +1 位作者 Zhien Liu Yawei Zhu 《Journal of Beijing Institute of Technology》 EI CAS 2020年第2期241-250,共10页
Ignoring the influence of flow velocity and flow temperature on muffling performance,performance tests were conducted without airflow in the development phase of the muffler which accounts to the difficulty of obtaini... Ignoring the influence of flow velocity and flow temperature on muffling performance,performance tests were conducted without airflow in the development phase of the muffler which accounts to the difficulty of obtaining a perfect match between the actual noise reduction effect and the design goal.Based on the two-load test theory,a set of high-temperature and high-speed airflow simulation measurement devices for the muffler has been built.In order to avoid the impact of high-temperature and high-speed airflow on the sensor,a high temperature resistant sensor holder has been designed for the test rig.The sound pressure has been measured in the pipe by using the lead-out measurement.In addition,a variable impedance load is placed at the end of the test tube to realize the switch between two different impedance loads by the wave handle of the variable impedance load.A sound source correction method is proposed to decrease the random fluctuation of the spectral characteristics of the output noise signal,which is caused by the acoustic impedance variation at the connection between the transition pipeline and the combined sound source system.Finally,an acoustic software has been used to calculate the transmission loss of the muffler in the presence of high temperature airflow.In comparing the experimental measurements and the simulation results,the small difference shows that:the bench not only can effectively simulate high-temperature and flow velocity environment of the engine but also accurately test the transmission loss of the muffler. 展开更多
关键词 muffler lead-out measurement variable load source correction transmission loss
下载PDF
Calculation and Analysis of Acoustic Characteristics of Straight-Through Perforated Pipe Muffler Based on Multilayer Sound Absorbing Material
19
作者 刘镕基 朱从云 +1 位作者 丁国芳 院蕾 《Journal of Donghua University(English Edition)》 CAS 2023年第5期506-514,共9页
Using the multi-physical field simulation software COMSOL,the acoustic characteristics of the multilayer sound absorbing material straight-through perforated pipe muffler are studied by the finite element method.The r... Using the multi-physical field simulation software COMSOL,the acoustic characteristics of the multilayer sound absorbing material straight-through perforated pipe muffler are studied by the finite element method.The results show that the finite element calculation of the multilayer sound absorbing material straight-through the perforated pipe muffler agrees well with the experimental measurement results.The reliability of the finite element method for studying the acoustic performance of the straight-through perforated pipe muffler with multilayer sound absorbing materials is shown.Furthermore,the influence of some structural parameters of porous sound absorbing material and micro-perforated plate on the acoustic performance of the multilayer sound absorbing material straight-through perforated pipe muffler is analyzed.The muffler based on multilayer sound absorbing material is different from the traditional muffler.After applying the multilayer sound absorbing material to the straight-through perforated pipe muffler,the transmission loss value greatly increases,which provides new ideas and directions for future research on the muffler. 展开更多
关键词 porous sound absorbing material perforated tube finite element method muffler acoustic characteristics
下载PDF
Research on the Flow and Heat Transfer Characteristics of a Water-Cooling Plate in a Heat Dissipation System
20
作者 Yukun Lv Zhuang Wei +2 位作者 Quanzhi Ge Fan Yang Shuang Yang 《Energy Engineering》 EI 2021年第6期1855-1867,共13页
The water-cooling heat dissipation technology can solve the heat dissipation and noise problems of the calculation plate.Therefore,the structural design of the water-cooling plate directly affects its flow and heat tr... The water-cooling heat dissipation technology can solve the heat dissipation and noise problems of the calculation plate.Therefore,the structural design of the water-cooling plate directly affects its flow and heat transfer characteristics,which restricts the promotion and application of the technology.To this end,the water-cooling plate of a heat dissipation system was taken as the research object,and its flow and heat transfer characteristics were numerical simulated and experimental studied.Through comparative analysis,the rationality of the numerical simulation method was verified.Based on this,three improved schemes of water-cooling plate structure were proposed and numerical simulation was carried out,and the optimal model was verified by experiments.The results of the study show that compared with the original water-cooling plate,the optimized water-cooling plate has increased internal flow velocity and distributes uniformly,increased heat transfer amount by 4.2%,and the average temperature of the calculation plate decreased by 5.3%. 展开更多
关键词 Calculation plate water-cooling plate flow and heat transfer characteristics
下载PDF
上一页 1 2 64 下一页 到第
使用帮助 返回顶部