期刊文献+
共找到756篇文章
< 1 2 38 >
每页显示 20 50 100
Three-year results of small incision lenticule extraction and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis for correction of high myopia and myopic astigmatism 被引量:20
1
作者 Li-Kun Xia Jing Ma +2 位作者 He-Nan Liu Ce Shi Qing Huang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第3期470-477,共8页
AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-gui... AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of high myopia and myopic astigmatism. METHODS: In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE) of -8.11±1.09 diopters (D) received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany) for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI) and tear break-up time (TBUT) were evaluated during a 3-year follow-up. RESULTS: The difference of uncorrected distance visual acuity (UDVA) postoperatively was achieved at lmo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant (t=-1.59, P=-0.13). The postoperative change of SE was 0.89 D in the FS-LASIK group (t=5.76, P=0.00), and 0.14 D in the SMILE group (t=-0.54, P=0.59) from lmo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group (P=0.00), but the coma root mean square (RMS) was higher in the SMILE group (0.59±0.26) than in the FS-LASIK group (0.29±0.14, P=0.00). The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at Imo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. CONCLUSION: Both SMILE and wavefront-guided FS- LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve more stable long-term refractive outcome and better control of early postoperative dry eye as compared to FS-LASIK. 展开更多
关键词 small incision lenticule extraction wavefront-guided femtosecond laser-assisted laser in situ keratomileusis femtosecond laser refractive surgery visual outcome
下载PDF
Comparison of optical quality after implantable collamer lens implantation and wavefront-guided laser in situ keratomileusis 被引量:13
2
作者 Hong-Ting Liu Zhou Zhou +8 位作者 Wu-Qiang Luo Wen-Jing He Owhofasa Agbedia Jiang-Xia Wang Jian-Zhong Huang Xin Gao Min Kong Min Li Li Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第4期656-661,共6页
AIM: To compare the optical quality after implantation of implantable collamer lens(ICL) and wavefront-guided laser in situ keratomileusis(WG-LASIK).METHODS: The study included 40 eyes of 22 patients with myopia... AIM: To compare the optical quality after implantation of implantable collamer lens(ICL) and wavefront-guided laser in situ keratomileusis(WG-LASIK).METHODS: The study included 40 eyes of 22 patients with myopia who accepted ICL implantation and 40 eyes of 20 patients with myopia who received WG-LASIK. Before surgery and three months after surgery, the objective scattering index(OSI), the values of modulation transfer function(MTF) cutoff frequency, Strehl ratio, and the Optical Quality Analysis System(OQAS) values(OVs) were accessed. The higher order aberrations(HOAs) data including coma, trefoil, spherical, 2^(nd) astigmatism and tetrafoil were also obtained. For patients with pupil size 〈6 mm, HOAs data were analyzed for 4 mm-pupil diameter. For patients with pupil size ≥6 mm, HOAs data were calculated for 6 mm-pupil diameter. Visual acuity, refraction, pupil size and intraocular pressures were also recorded.RESULTS: In both ICL and WG-LASIK group, significant improvements in visual acuities were found postoperatively, with a significant reduction in spherical equivalent(P〈 0.001). After the ICL implantation, the OSI decreasedslightly from 2.34±1.92 to 2.24±1.18 with no statistical significance(P=0.62). While in WG-LASIK group, the OSI significantly increased from 0.68±0.43 preoperatively to 0.91±0.53 postoperatively(Wilcoxon signed ranks test, P=0.000). None of the mean MTF cutoff frequency, Strehl ratio, OVs showed statistically significant changes in both ICL and WG-LASIK groups. In the ICL group, there were no statistical differences in the total HOAs for either 4 mmpupil or 6 mm-pupil. In the WG-LASIK group, the HOA parameters increased significantly at 4 mm-pupil. The total ocular HOAs, coma, spherical and 2^(nd) astigmatism were 0.12±0.06, 0.06±0.03, 0.00±0.03, 0.02±0.01, respectively. After the operation, these values were increased into 0.16±0.07, 0.08±0.05,-0.04±0.04, 0.03±0.01 respectively(Wilcoxon signed ranks test, all P〈0.05). At 6 mm-pupil, the induction of total HOAs was not statistically significant in the WG-LASIK group. CONCLUSION: ICL implantation has a less disturbance to optical quality than WG-LASIK. The OQAS is a valuable complementary measurement to the wavefront aberrometers in evaluating the optical quality. 展开更多
关键词 optical quality implantable collamer lens wavefront-guided laser in situ keratomileusis
下载PDF
Characterization of relativistic electrons generated by a cone guiding laser pulse 被引量:1
3
作者 刘红杰 谷渝秋 +10 位作者 周维民 余金清 朱斌 吴玉迟 单连强 温贤伦 李芳 钱凤 曹磊峰 张保汉 郑志坚 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第5期1-5,共5页
We demonstrated the interaction of a gold cone target with a femto second(fs) laser pulse above the relativistic intensity of 1.37×10 18 μm 2 W/cm 2.Relativistic electrons with energy above 2 MeV were observed... We demonstrated the interaction of a gold cone target with a femto second(fs) laser pulse above the relativistic intensity of 1.37×10 18 μm 2 W/cm 2.Relativistic electrons with energy above 2 MeV were observed.A 25%-40% increase of the electron temperature is achieved compared to the case when a plane gold target is used.The electron temperature increase results from the guiding of the laser beam at the tip and the intense quasistatic magnetic field in the cone geometry.The behavior of the relativistic electrons is verified in our 2D-PIC simulations. 展开更多
关键词 relativistic electrons gold cone guiding laser electron temperature
下载PDF
The single-longitudinal-mode operation of a ridge waveguide laser based on two-dimensional photonic crystals 被引量:1
4
作者 王华勇 许兴胜 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第5期315-319,共5页
An electrically driven, single-longitudinal-mode GaAs based photonic crystal (PC) ridge waveguide (RWG) laser emitting at around 850 nm is demonstrated. The single-longitudinal-mode lasing characteristic is achiev... An electrically driven, single-longitudinal-mode GaAs based photonic crystal (PC) ridge waveguide (RWG) laser emitting at around 850 nm is demonstrated. The single-longitudinal-mode lasing characteristic is achieved by introducing the PC to the RWG laser. The triangle PC is etched on both sides of the ridge by photolithography and inductive coupled plasma (ICP) etching. The lasing spectra of the RWG lasers with and without the PC are studied, and the result shows that the PC purifies the longitudinal mode. The power per facet versus current and current-voltage characteristics have also been studied and compared. 展开更多
关键词 ridge waveguide laser photonic crystals single-longitudinal mode effective index guided mode
下载PDF
Configuration optimization of laser guide stars and wavefront correctors for multi-conjugation adaptive optics 被引量:1
5
作者 宣丽 何斌 +9 位作者 胡立发 李大禹 徐焕宇 张杏云 王少鑫 王玉坤 杨程亮 曹召良 穆全全 鲁兴海 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第9期91-98,共8页
Multi-conjugation adaptive optics(MCAOs) have been investigated and used in the large aperture optical telescopes for high-resolution imaging with large field of view(FOV).The atmospheric tomographic phase reconst... Multi-conjugation adaptive optics(MCAOs) have been investigated and used in the large aperture optical telescopes for high-resolution imaging with large field of view(FOV).The atmospheric tomographic phase reconstruction and projection of three-dimensional turbulence volume onto wavefront correctors,such as deformable mirrors(DMs) or liquid crystal wavefront correctors(LCWCs),is a very important step in the data processing of an MCAO's controller.In this paper,a method according to the wavefront reconstruction performance of MCAO is presented to evaluate the optimized configuration of multi laser guide stars(LGSs) and the reasonable conjugation heights of LCWCs.Analytical formulations are derived for the different configurations and are used to generate optimized parameters for MCAO.Several examples are given to demonstrate our LGSs configuration optimization method.Compared with traditional methods,our method has minimum wavefront tomographic error,which will be helpful to get higher imaging resolution at large FOV in MCAO. 展开更多
关键词 laser guide star liquid crystal wavefront corrector adaptive optics phase reconstruction
下载PDF
Analysis of the far spatial coherent suppressed single peak field distribution of a rectangular wave-guide laser 被引量:2
6
作者 吴行飞 杨静 辛建国 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第4期1031-1037,共7页
A theory of the far spatial coherent-suppressed single-peak field distribution of a rectangular wave-guide CO2 laser is presented. The theoretical analysis shows that a rectangular wave-guide laser can have an output ... A theory of the far spatial coherent-suppressed single-peak field distribution of a rectangular wave-guide CO2 laser is presented. The theoretical analysis shows that a rectangular wave-guide laser can have an output intensity distribution in far field similar to that produced from a wave-guide array laser, which is in agreement with the experimental result. A single-peak mode output is obtained within 5 metres. The experimental far-field spread angle in the bigger-Fresnel number direction is 0.63 mrad, compared to the calculated one, 0.6 mrad, and when the length of the laser resonator is changed, a double-peak or multi-peak in far-field distribution of the laser is obtained. 展开更多
关键词 wave-guide array CO2 laser field distribution
下载PDF
Triggering and guiding of high voltage discharge by using femtosecond laser filaments with different parameters
7
作者 张喆 鲁欢 +4 位作者 梁文锡 郝作强 周木林 王兆华 张杰 《Chinese Physics B》 SCIE EI CAS CSCD 2009年第3期1136-1140,共5页
This paper demonstrates the triggering and guiding of the stationary high voltage (HV) discharges at 5-40kV by using plasma filaments generated by femtosecond laser pulses in air. A significant reduction of the brea... This paper demonstrates the triggering and guiding of the stationary high voltage (HV) discharges at 5-40kV by using plasma filaments generated by femtosecond laser pulses in air. A significant reduction of the breakdown voltage threshold due to the pre-ionization of the air gap by laser filamentation is observed. The discharge experiments are performed by using laser pulses with different energy from 15-60 mJ. The electron density of filaments is detected by sonography method. The influence of the electron density of laser filaments on the triggering and guiding HV discharge is experimentally investigated. The results have shown that the behaviour of plasma filaments can strongly affect the efficiency of triggering and guiding HV discharge. 展开更多
关键词 laser filaments HV discharge TRIGGERING guidING
下载PDF
Three-dimensional simulation of long-wavelength free-electron lasers with helical wiggler and ion-channel guiding
8
作者 F. Jafari Bahman B. Maraghechi 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第7期183-191,共9页
A three-dimensional simulation of a steady-state amplifier model of a long-wavelength free-electron laser (FEL) with realizable helical wiggler and ion-channel guiding is presented. The set of coupled nonlinear diff... A three-dimensional simulation of a steady-state amplifier model of a long-wavelength free-electron laser (FEL) with realizable helical wiggler and ion-channel guiding is presented. The set of coupled nonlinear differential equations for electron orbits and fields of TE 11 mode in a cylindrical waveguide are solved numerically by the Runge–Kutta algorithm with averages calculated by the Gaussian quadrature technique. Self-fields and space-charge effects are neglected, and the electron beam is assumed to be cold and slippage is ignored. The parameters correspond to the Compton regime. Evolution of the radiation power and growth rate along the wiggler is studied. Ion-channel density is chosen to obtain optimum efficiency. Simulations are preformed for the FEL operating in the neighborhood of 35 GHz and 16.5 GHz for the electron beam energies of 250 keV and 400 keV, respectively. The result of the saturated efficiency was found to be in good agreement with the simple estimation based on the phase-trapping model. 展开更多
关键词 free-electron laser helical wiggler ion-channel guiding
下载PDF
Laser guiding of cold molecules in a hollow optical fiber and continuous-wave cold molecular beam generation
9
作者 刘润琴 尹亚玲 印建平 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第3期185-190,共6页
A novel scheme for guiding arbitrary buffer-gas cooled neutral molecules in a hollow optical fiber (HOF) using a red-detuned HEll mode is proposed and analysed theoretically. We give the electromagnetic field distri... A novel scheme for guiding arbitrary buffer-gas cooled neutral molecules in a hollow optical fiber (HOF) using a red-detuned HEll mode is proposed and analysed theoretically. We give the electromagnetic field distribution of the HEll mode in the HOF and calculate the optical potential of an 12 molecule, and study the molecule guiding mechanism using a classical Monte Carlo simulation. Using a 6 kW input laser, an S-shape HOF with a 2 cm curvature radius for both bends, and an input molecular beam with a transverse temperature of 0.5 K and longitudinal temperature of 5 K, we obtain a guiding efficiency of -0.126% for the scheme, and the transverse and longitudinal temperatures of the guided molecular beam are 1.9 mK and 0.5 K, respectively. 展开更多
关键词 laser guiding cold molecular beam
下载PDF
Development and Demonstration of Australian First Working Sodium Guide Star Laser
10
作者 Yue Gao Yanjie Wang +1 位作者 Amy Chan Ben Greene 《Optics and Photonics Journal》 CAS 2022年第4期88-100,共13页
The Australian first working sodium guide star laser system has been designed and developed for various astronomical and space-related applications. A completely diode-pumped pulsed system was developed initially foll... The Australian first working sodium guide star laser system has been designed and developed for various astronomical and space-related applications. A completely diode-pumped pulsed system was developed initially followed by a largely fiber-based continuous wave (CW) system operating at 589 nm achieved through a unique wavelength conversion scheme by combining 1342 and 1050 nm through a sum frequency generation process. For the CW system, single-mode laser beams at both 1342 and 1050 nm are achieved from fiber-based seed oscillators and fiber amplifiers. The output power of ~25 W at 1342 nm is achieved from a single frequency fiber Raman amplifier. Output power up to 70 W at 1050 nm is achieved from a Yb-doped fiber pre-amplifier followed by a Yb-doped fiber power amplifier. For the sum frequency generation process, optimum focusing parameters are evaluated and determined. The CW system has generated more than 20 W output power at 589 nm, a circularly polarised beam with a good beam quality, spectral linewidth ≤ 2 MHz, and the laser output locked on the sodium D2 line at 589.159 nm. The system has been successfully demonstrated at EOS Space Research Centre, Mt Stromlo, Canberra, and become the Australian first working sodium guide star laser system. 展开更多
关键词 Fiber laser Continuous Wave laser Pulsed laser Diode Pump Solid State Sum Frequency Generation Adaptive Optics Sodium laser guide Star
下载PDF
A high precision phase reconstruction algorithm for multi-laser guide stars adaptive optics
11
作者 何斌 胡立发 +9 位作者 李大禹 徐焕宇 张杏云 王少鑫 王玉坤 杨程亮 曹召良 穆全全 鲁兴海 宣丽 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第9期83-87,共5页
Adaptive optics(AO) systems are widespread and considered as an essential part of any large aperture telescope for obtaining a high resolution imaging at present.To enlarge the imaging field of view(FOV),multi-las... Adaptive optics(AO) systems are widespread and considered as an essential part of any large aperture telescope for obtaining a high resolution imaging at present.To enlarge the imaging field of view(FOV),multi-laser guide stars(LGSs) are currently being investigated and used for the large aperture optical telescopes.LGS measurement is necessary and pivotal to obtain the cumulative phase distortion along a target in the multi-LGSs AO system.We propose a high precision phase reconstruction algorithm to estimate the phase for a target with an uncertain turbulence profile based on the interpolation.By comparing with the conventional average method,the proposed method reduces the root mean square(RMS) error from 130 nm to 85 nm with a 30% reduction for narrow FOV.We confirm that such phase reconstruction algorithm is validated for both narrow field AO and wide field AO. 展开更多
关键词 laser guide star adaptive optics phase reconstruction liquid crystal wavefront corrector
下载PDF
Contour Laser Guiding for the Mechanized "Vallerani" Micro-catchment Water Harvesting Systems
12
作者 I.A. Gammoh T.Y. Oweis 《Journal of Environmental Science and Engineering》 2011年第10期1309-1316,共8页
Mechanized construction of micro-catchments for water harvesting (WH) was successfully tested in the Badia (dry rangeland) areas in Syria and Jordan, using the "Vallerani" plow, model Delfino (50 MI/CM), manuf... Mechanized construction of micro-catchments for water harvesting (WH) was successfully tested in the Badia (dry rangeland) areas in Syria and Jordan, using the "Vallerani" plow, model Delfino (50 MI/CM), manufactured by Nardi, Italy. The plow was able to construct intermittent and continuous contour ridges, and could potentially be used to rehabilitate degraded rangelands. However, one major issue for large-scale implementation is the high cost and time required to manually identify contours for the plow to follow. Most existing auto-guiding systems, as usually used in road construction and agricultural land leveling, were expensive or impractical. The objective, therefore, was to add, adapt, and evaluate an auto-guiding system to enable a tractor to follow contours without demarcation through conventional surveying. A low-cost Contour Laser Guiding (CLG) system, with specifications that suit the contour ridging in undulating topographic conditions of dry rangelands, was chosen, adapted, mounted, and tested, under actual field conditions. The system consisted mainly of a portable laser transmitter and a tractor-mounted receiver, connected to a guidance display panel. The system was field-tested on 95 ha of land where the system capacity was determined under different terrains, slopes (1-8%), and ridge spacings (4-12 m). The easy adaptation and implementation of the CLG to the "Vallerani" unit tripled the system capacity, improved efficiency and precision, and substantially reduced the cost of constructing micro-catchments for WH. The system is recommended for large-scale rangeland rehabilitation projects in the dry areas, not only in West Asia, but worldwide. 展开更多
关键词 Badia land degradation contour micro-catchments laser guiding Vallerani system.
下载PDF
Characterization of relativistic electrons generated by a cone guiding laser pulse
13
作者 刘红杰 谷渝秋 +10 位作者 周维民 余金清 朱斌 吴玉迟 单连强 温贤伦 李芳 钱凤 曹磊峰 张保汉 郑志坚 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第5期5-9,共5页
We demonstrated the interaction of a gold cone target with a femto second(fs) laser pulse above the relativistic intensity of 1.37×10 18 μm 2 W/cm 2.Relativistic electrons with energy above 2 MeV were observed.A... We demonstrated the interaction of a gold cone target with a femto second(fs) laser pulse above the relativistic intensity of 1.37×10 18 μm 2 W/cm 2.Relativistic electrons with energy above 2 MeV were observed.A 25%-40% increase of the electron temperature is achieved compared to the case when a plane gold target is used.The electron temperature increase results from the guiding of the laser beam at the tip and the intense quasistatic magnetic field in the cone geometry.The behavior of the relativistic electrons is verified in our 2D-PIC simulations. 展开更多
关键词 relativistic electrons gold cone guiding laser electron temperature
全文增补中
Laser-induced Interstitial Thermotherapy via a Single-needle Delivery System: Optimal Conditions of Ablation, Pathological and Ultrasonic Changes 被引量:3
14
作者 张艳容 方凌云 +10 位作者 余铖 孙振兴 黄艳 陈娟 郭涛 项飞翔 王静 鲁成发 严天慰 吕清 谢明星 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2015年第4期579-584,共6页
Summary: This study aimed to examine the optimal conditions of laser-induced interstitial ther- motherapy (LITT) via a single-needle delivery system, and the ablation-related pathological and ultra- sonic changes. ... Summary: This study aimed to examine the optimal conditions of laser-induced interstitial ther- motherapy (LITT) via a single-needle delivery system, and the ablation-related pathological and ultra- sonic changes. Ultrasound (US)-guided LITT (EchoLaser system) was performed at the output power of 2--4 Wattage (W) for 1-10 min in ex vivo bovine liver. Based on the results of the ex vivo study, the output power of 3 and 4 W with different durations was applied to in vivo rabbit livers (n=24), and VX2 tumors implanted in the hind limbs of rabbits (n=24). The ablation area was histologically determined by hematoxylin-eosin (HE) staining. Traditional US and contrast enhanced ultrasound (CEUS) were used to evaluate the treatment outcomes. The results showed: (1) In the bovine liver, ablation disruption was grossly seen, including a strip-like ablation crater, a carbonization zone anteriorly along the fiber tip, and a surrounding gray-white coagulation zone. The coagulation area, 1.2 cm in length and 1.0 cm in width, was formed in the bovine liver subjected to the ablation at 3 W for 5 min and 4 W for 4 rain, and it extended slightly with the ablation time. (2) In the rabbit liver, after LITT at 3 W for 3 min and more, the coagulation area with length greater than or equal to 1.2 cm, and width greater than or equal to 1.0 cm, was found. Similar coagulation area was seen in the implanted VX2 carcinoma at 3 W for 5 min. (3) Gross examination of the liver and carcinoma showed three distinct regions: ablation cra- ter/carbonization, coagulation and congestion distributed from the center outwards. (4) Microscopy re- vealed four zones after LITT, including ablation crater/carbonization, coagulation, edema and conges- tion from the center outwards. A large area with coagulative necrosis was observed around a vessel in the peripheral area with edema and hyperemia. (5) The size of coagulation was consistent well to the CEUS findings. It was concluded that EchoLaser system at low power can produce a coagulation area larger than 1.0 cm×1.0 cm during a short time period. The real-time US imaging can be used to effec- tively guide and assess the treatment. 展开更多
关键词 laser-induced interstitial thermotherapy ultrasound-guided ablation contrast-enhanced ul- trasound single-needle delivery
下载PDF
A novel absorptive thin film for laser welding in optoelectronic device capsulation 被引量:1
15
作者 JIANG Shao-ji JIN Tao LI Wei-duo WANG He-zhou 《光学精密工程》 EI CAS CSCD 北大核心 2005年第4期492-499,共8页
A kind of absorptive thin film was designed and used in laser welding of SiO2, Si and LiNbO3. This absorptive thin film of three-layer metal-dielectric-metal structure is designed for further reducing the high reflect... A kind of absorptive thin film was designed and used in laser welding of SiO2, Si and LiNbO3. This absorptive thin film of three-layer metal-dielectric-metal structure is designed for further reducing the high reflectance of the Nd:YAG laser beam on the surface of the tin layer that is utilized as solder between the transparent parent materials. The actual absorption of laser energy in experiment exceeds 99%. This combination of absorber and solder transformed the laser energy into heat efficiently and decreased the minimum necessary incident laser power transmitting through the transparent parent materials. As a result, the damage of the parent materials, which is suffered from laser transmission, was avoided; On the other hand, mechanical stability of the welded materials had been improved. Experiment had been made to show the difference between welding with and without the absorptive thin film. 展开更多
关键词 光电子装置 封装工艺 薄膜 激光仪器 激光技术
下载PDF
Influence of a Magnetic Guide Field on Self-Injection in Wakefield Acceleration
16
作者 Alain Bourdier Guillaume Girard +2 位作者 Sébastien Rassou Xavier Davoine Mathieu Drouin 《Journal of Modern Physics》 2012年第12期1983-1990,共8页
The influence of an external static field applied in the direction of propagation of a high intensity driving laser pulse on the electron trapping in laser wakefield acceleration is explored. It is shown that, in the ... The influence of an external static field applied in the direction of propagation of a high intensity driving laser pulse on the electron trapping in laser wakefield acceleration is explored. It is shown that, in the case of self-injection, the electric charge accelerated can be enhanced in some physical situations. 展开更多
关键词 laser WAKEFIELD ACCELERATION MAGNETIC guide Field Electron INJECTION SELF-TRAPPING
下载PDF
气管内超声引导纵隔肿瘤激光多点消融操作流程 被引量:2
17
作者 刘丹 万南生 +4 位作者 王杰 李广生 谢巍 田羽 冯靖 《天津医药》 CAS 2024年第1期80-83,共4页
由于纵隔解剖位置复杂,重要脏器较多,纵隔肿瘤的治疗一直是临床难点。相比传统局部治疗,气道内超声引导纵隔肿瘤激光多点消融具有较多优势,包括消融范围及效果可实时监控、避免损伤正常组织、不良反应少、耐受性好等。该文阐述了气管内... 由于纵隔解剖位置复杂,重要脏器较多,纵隔肿瘤的治疗一直是临床难点。相比传统局部治疗,气道内超声引导纵隔肿瘤激光多点消融具有较多优势,包括消融范围及效果可实时监控、避免损伤正常组织、不良反应少、耐受性好等。该文阐述了气管内超声引导纵隔肿瘤激光多点消融的操作流程。 展开更多
关键词 导管消融术 支气管镜 纵隔肿瘤 气道内超声引导激光消融
下载PDF
Simulation of coherent spontaneous emission in a FEL with a groove guide
18
作者 LUO Feng BEI Hua +1 位作者 LIN Xuling DAI Zhimin 《Nuclear Science and Techniques》 SCIE CAS CSCD 2009年第6期321-324,共4页
Based on a femtosecond linear accelerator, here we present a study of the use of a groove guide as the FEL interaction structure for high power FEL experiment. The transmission and attenuation characteristics of the d... Based on a femtosecond linear accelerator, here we present a study of the use of a groove guide as the FEL interaction structure for high power FEL experiment. The transmission and attenuation characteristics of the dominant mode in the groove guide are discussed. And the coherent spontaneous emission in the FEL is simulated by Gover theory. 展开更多
关键词 自由电子激光 自发辐射 指南 模拟 相干 凹槽 直线加速器 激光实验
下载PDF
A quantitative method for calculating irradiation area of laser target designator
19
作者 ZHANG Jiandong HUANG Zhiyi SHI Guoqing 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2019年第4期633-641,共9页
In laser-guided bomb attacking process,the target indication from the laser target designator is the premise for the bomb to hit the target accurately.Considering the lack of quantitative study of the irradiation area... In laser-guided bomb attacking process,the target indication from the laser target designator is the premise for the bomb to hit the target accurately.Considering the lack of quantitative study of the irradiation area of the laser target designator,this paper,based on the existing aircraft motion model and the laser transmission model,uses two aircraft as respectively the carrier of the laser-guided bomb and the carrier of the laser designator and proposes a method to calculate the global irradiation area of the airborne laser designator.By using the proposed algorithm,the global irradiation area when attacking a large flat target or a large spherical target is simulated respectively.Finally,according to the simulation results,the influences of different factors on the shapes of the irradiation area are discussed in detail. 展开更多
关键词 laser-guided BOMB IRRADIATION area laser target designator SEMI-ACTIVE guidance
下载PDF
Design of Two-Dimensional Photonic Crystal Edge Emitting Laser for Photonic Integrated Circuits
20
作者 马小涛 郑婉华 +1 位作者 任刚 陈良惠 《Chinese Physics Letters》 SCIE CAS CSCD 2006年第10期2759-2762,共4页
An edge emitting laser based on two-dimensional photonic crystal slabs is proposed. The device consists of a square lattice microcavity, which is composed of two structures with the same period but different radius of... An edge emitting laser based on two-dimensional photonic crystal slabs is proposed. The device consists of a square lattice microcavity, which is composed of two structures with the same period but different radius of air-holes, and a waveguide. In the cavity, laser resonance in the inner structure benefits from not only the anomalous dispersion characteristic of the first band-edge at the M point in the first Brillouin-zone but also zero photon states in the outer structure. A line defect waveguide is introduced in the outer structure for extracting photons from the inner cavity. Three-dimensional finite-difference time-domain simulations apparently show the in-plane laser output from the waveguide. The microcavity has an effective mode volume of about 3.2(λ/nslab)^3 for oscillation mode and the quality factor of the device including line defect waveguide is estimated to be as high as 1300. 展开更多
关键词 HIGH-QUALITY-FACTOR WAVE-guidE laser DEFECT MODES SLAB LATTICE VOLUME
下载PDF
上一页 1 2 38 下一页 到第
使用帮助 返回顶部