AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-gui...AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of high myopia and myopic astigmatism. METHODS: In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE) of -8.11±1.09 diopters (D) received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany) for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI) and tear break-up time (TBUT) were evaluated during a 3-year follow-up. RESULTS: The difference of uncorrected distance visual acuity (UDVA) postoperatively was achieved at lmo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant (t=-1.59, P=-0.13). The postoperative change of SE was 0.89 D in the FS-LASIK group (t=5.76, P=0.00), and 0.14 D in the SMILE group (t=-0.54, P=0.59) from lmo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group (P=0.00), but the coma root mean square (RMS) was higher in the SMILE group (0.59±0.26) than in the FS-LASIK group (0.29±0.14, P=0.00). The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at Imo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. CONCLUSION: Both SMILE and wavefront-guided FS- LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve more stable long-term refractive outcome and better control of early postoperative dry eye as compared to FS-LASIK.展开更多
AIM: To compare the optical quality after implantation of implantable collamer lens(ICL) and wavefront-guided laser in situ keratomileusis(WG-LASIK).METHODS: The study included 40 eyes of 22 patients with myopia...AIM: To compare the optical quality after implantation of implantable collamer lens(ICL) and wavefront-guided laser in situ keratomileusis(WG-LASIK).METHODS: The study included 40 eyes of 22 patients with myopia who accepted ICL implantation and 40 eyes of 20 patients with myopia who received WG-LASIK. Before surgery and three months after surgery, the objective scattering index(OSI), the values of modulation transfer function(MTF) cutoff frequency, Strehl ratio, and the Optical Quality Analysis System(OQAS) values(OVs) were accessed. The higher order aberrations(HOAs) data including coma, trefoil, spherical, 2^(nd) astigmatism and tetrafoil were also obtained. For patients with pupil size 〈6 mm, HOAs data were analyzed for 4 mm-pupil diameter. For patients with pupil size ≥6 mm, HOAs data were calculated for 6 mm-pupil diameter. Visual acuity, refraction, pupil size and intraocular pressures were also recorded.RESULTS: In both ICL and WG-LASIK group, significant improvements in visual acuities were found postoperatively, with a significant reduction in spherical equivalent(P〈 0.001). After the ICL implantation, the OSI decreasedslightly from 2.34±1.92 to 2.24±1.18 with no statistical significance(P=0.62). While in WG-LASIK group, the OSI significantly increased from 0.68±0.43 preoperatively to 0.91±0.53 postoperatively(Wilcoxon signed ranks test, P=0.000). None of the mean MTF cutoff frequency, Strehl ratio, OVs showed statistically significant changes in both ICL and WG-LASIK groups. In the ICL group, there were no statistical differences in the total HOAs for either 4 mmpupil or 6 mm-pupil. In the WG-LASIK group, the HOA parameters increased significantly at 4 mm-pupil. The total ocular HOAs, coma, spherical and 2^(nd) astigmatism were 0.12±0.06, 0.06±0.03, 0.00±0.03, 0.02±0.01, respectively. After the operation, these values were increased into 0.16±0.07, 0.08±0.05,-0.04±0.04, 0.03±0.01 respectively(Wilcoxon signed ranks test, all P〈0.05). At 6 mm-pupil, the induction of total HOAs was not statistically significant in the WG-LASIK group. CONCLUSION: ICL implantation has a less disturbance to optical quality than WG-LASIK. The OQAS is a valuable complementary measurement to the wavefront aberrometers in evaluating the optical quality.展开更多
We demonstrated the interaction of a gold cone target with a femto second(fs) laser pulse above the relativistic intensity of 1.37×10 18 μm 2 W/cm 2.Relativistic electrons with energy above 2 MeV were observed...We demonstrated the interaction of a gold cone target with a femto second(fs) laser pulse above the relativistic intensity of 1.37×10 18 μm 2 W/cm 2.Relativistic electrons with energy above 2 MeV were observed.A 25%-40% increase of the electron temperature is achieved compared to the case when a plane gold target is used.The electron temperature increase results from the guiding of the laser beam at the tip and the intense quasistatic magnetic field in the cone geometry.The behavior of the relativistic electrons is verified in our 2D-PIC simulations.展开更多
An electrically driven, single-longitudinal-mode GaAs based photonic crystal (PC) ridge waveguide (RWG) laser emitting at around 850 nm is demonstrated. The single-longitudinal-mode lasing characteristic is achiev...An electrically driven, single-longitudinal-mode GaAs based photonic crystal (PC) ridge waveguide (RWG) laser emitting at around 850 nm is demonstrated. The single-longitudinal-mode lasing characteristic is achieved by introducing the PC to the RWG laser. The triangle PC is etched on both sides of the ridge by photolithography and inductive coupled plasma (ICP) etching. The lasing spectra of the RWG lasers with and without the PC are studied, and the result shows that the PC purifies the longitudinal mode. The power per facet versus current and current-voltage characteristics have also been studied and compared.展开更多
Multi-conjugation adaptive optics(MCAOs) have been investigated and used in the large aperture optical telescopes for high-resolution imaging with large field of view(FOV).The atmospheric tomographic phase reconst...Multi-conjugation adaptive optics(MCAOs) have been investigated and used in the large aperture optical telescopes for high-resolution imaging with large field of view(FOV).The atmospheric tomographic phase reconstruction and projection of three-dimensional turbulence volume onto wavefront correctors,such as deformable mirrors(DMs) or liquid crystal wavefront correctors(LCWCs),is a very important step in the data processing of an MCAO's controller.In this paper,a method according to the wavefront reconstruction performance of MCAO is presented to evaluate the optimized configuration of multi laser guide stars(LGSs) and the reasonable conjugation heights of LCWCs.Analytical formulations are derived for the different configurations and are used to generate optimized parameters for MCAO.Several examples are given to demonstrate our LGSs configuration optimization method.Compared with traditional methods,our method has minimum wavefront tomographic error,which will be helpful to get higher imaging resolution at large FOV in MCAO.展开更多
A theory of the far spatial coherent-suppressed single-peak field distribution of a rectangular wave-guide CO2 laser is presented. The theoretical analysis shows that a rectangular wave-guide laser can have an output ...A theory of the far spatial coherent-suppressed single-peak field distribution of a rectangular wave-guide CO2 laser is presented. The theoretical analysis shows that a rectangular wave-guide laser can have an output intensity distribution in far field similar to that produced from a wave-guide array laser, which is in agreement with the experimental result. A single-peak mode output is obtained within 5 metres. The experimental far-field spread angle in the bigger-Fresnel number direction is 0.63 mrad, compared to the calculated one, 0.6 mrad, and when the length of the laser resonator is changed, a double-peak or multi-peak in far-field distribution of the laser is obtained.展开更多
This paper demonstrates the triggering and guiding of the stationary high voltage (HV) discharges at 5-40kV by using plasma filaments generated by femtosecond laser pulses in air. A significant reduction of the brea...This paper demonstrates the triggering and guiding of the stationary high voltage (HV) discharges at 5-40kV by using plasma filaments generated by femtosecond laser pulses in air. A significant reduction of the breakdown voltage threshold due to the pre-ionization of the air gap by laser filamentation is observed. The discharge experiments are performed by using laser pulses with different energy from 15-60 mJ. The electron density of filaments is detected by sonography method. The influence of the electron density of laser filaments on the triggering and guiding HV discharge is experimentally investigated. The results have shown that the behaviour of plasma filaments can strongly affect the efficiency of triggering and guiding HV discharge.展开更多
A three-dimensional simulation of a steady-state amplifier model of a long-wavelength free-electron laser (FEL) with realizable helical wiggler and ion-channel guiding is presented. The set of coupled nonlinear diff...A three-dimensional simulation of a steady-state amplifier model of a long-wavelength free-electron laser (FEL) with realizable helical wiggler and ion-channel guiding is presented. The set of coupled nonlinear differential equations for electron orbits and fields of TE 11 mode in a cylindrical waveguide are solved numerically by the Runge–Kutta algorithm with averages calculated by the Gaussian quadrature technique. Self-fields and space-charge effects are neglected, and the electron beam is assumed to be cold and slippage is ignored. The parameters correspond to the Compton regime. Evolution of the radiation power and growth rate along the wiggler is studied. Ion-channel density is chosen to obtain optimum efficiency. Simulations are preformed for the FEL operating in the neighborhood of 35 GHz and 16.5 GHz for the electron beam energies of 250 keV and 400 keV, respectively. The result of the saturated efficiency was found to be in good agreement with the simple estimation based on the phase-trapping model.展开更多
A novel scheme for guiding arbitrary buffer-gas cooled neutral molecules in a hollow optical fiber (HOF) using a red-detuned HEll mode is proposed and analysed theoretically. We give the electromagnetic field distri...A novel scheme for guiding arbitrary buffer-gas cooled neutral molecules in a hollow optical fiber (HOF) using a red-detuned HEll mode is proposed and analysed theoretically. We give the electromagnetic field distribution of the HEll mode in the HOF and calculate the optical potential of an 12 molecule, and study the molecule guiding mechanism using a classical Monte Carlo simulation. Using a 6 kW input laser, an S-shape HOF with a 2 cm curvature radius for both bends, and an input molecular beam with a transverse temperature of 0.5 K and longitudinal temperature of 5 K, we obtain a guiding efficiency of -0.126% for the scheme, and the transverse and longitudinal temperatures of the guided molecular beam are 1.9 mK and 0.5 K, respectively.展开更多
The Australian first working sodium guide star laser system has been designed and developed for various astronomical and space-related applications. A completely diode-pumped pulsed system was developed initially foll...The Australian first working sodium guide star laser system has been designed and developed for various astronomical and space-related applications. A completely diode-pumped pulsed system was developed initially followed by a largely fiber-based continuous wave (CW) system operating at 589 nm achieved through a unique wavelength conversion scheme by combining 1342 and 1050 nm through a sum frequency generation process. For the CW system, single-mode laser beams at both 1342 and 1050 nm are achieved from fiber-based seed oscillators and fiber amplifiers. The output power of ~25 W at 1342 nm is achieved from a single frequency fiber Raman amplifier. Output power up to 70 W at 1050 nm is achieved from a Yb-doped fiber pre-amplifier followed by a Yb-doped fiber power amplifier. For the sum frequency generation process, optimum focusing parameters are evaluated and determined. The CW system has generated more than 20 W output power at 589 nm, a circularly polarised beam with a good beam quality, spectral linewidth ≤ 2 MHz, and the laser output locked on the sodium D2 line at 589.159 nm. The system has been successfully demonstrated at EOS Space Research Centre, Mt Stromlo, Canberra, and become the Australian first working sodium guide star laser system.展开更多
Adaptive optics(AO) systems are widespread and considered as an essential part of any large aperture telescope for obtaining a high resolution imaging at present.To enlarge the imaging field of view(FOV),multi-las...Adaptive optics(AO) systems are widespread and considered as an essential part of any large aperture telescope for obtaining a high resolution imaging at present.To enlarge the imaging field of view(FOV),multi-laser guide stars(LGSs) are currently being investigated and used for the large aperture optical telescopes.LGS measurement is necessary and pivotal to obtain the cumulative phase distortion along a target in the multi-LGSs AO system.We propose a high precision phase reconstruction algorithm to estimate the phase for a target with an uncertain turbulence profile based on the interpolation.By comparing with the conventional average method,the proposed method reduces the root mean square(RMS) error from 130 nm to 85 nm with a 30% reduction for narrow FOV.We confirm that such phase reconstruction algorithm is validated for both narrow field AO and wide field AO.展开更多
Mechanized construction of micro-catchments for water harvesting (WH) was successfully tested in the Badia (dry rangeland) areas in Syria and Jordan, using the "Vallerani" plow, model Delfino (50 MI/CM), manuf...Mechanized construction of micro-catchments for water harvesting (WH) was successfully tested in the Badia (dry rangeland) areas in Syria and Jordan, using the "Vallerani" plow, model Delfino (50 MI/CM), manufactured by Nardi, Italy. The plow was able to construct intermittent and continuous contour ridges, and could potentially be used to rehabilitate degraded rangelands. However, one major issue for large-scale implementation is the high cost and time required to manually identify contours for the plow to follow. Most existing auto-guiding systems, as usually used in road construction and agricultural land leveling, were expensive or impractical. The objective, therefore, was to add, adapt, and evaluate an auto-guiding system to enable a tractor to follow contours without demarcation through conventional surveying. A low-cost Contour Laser Guiding (CLG) system, with specifications that suit the contour ridging in undulating topographic conditions of dry rangelands, was chosen, adapted, mounted, and tested, under actual field conditions. The system consisted mainly of a portable laser transmitter and a tractor-mounted receiver, connected to a guidance display panel. The system was field-tested on 95 ha of land where the system capacity was determined under different terrains, slopes (1-8%), and ridge spacings (4-12 m). The easy adaptation and implementation of the CLG to the "Vallerani" unit tripled the system capacity, improved efficiency and precision, and substantially reduced the cost of constructing micro-catchments for WH. The system is recommended for large-scale rangeland rehabilitation projects in the dry areas, not only in West Asia, but worldwide.展开更多
We demonstrated the interaction of a gold cone target with a femto second(fs) laser pulse above the relativistic intensity of 1.37×10 18 μm 2 W/cm 2.Relativistic electrons with energy above 2 MeV were observed.A...We demonstrated the interaction of a gold cone target with a femto second(fs) laser pulse above the relativistic intensity of 1.37×10 18 μm 2 W/cm 2.Relativistic electrons with energy above 2 MeV were observed.A 25%-40% increase of the electron temperature is achieved compared to the case when a plane gold target is used.The electron temperature increase results from the guiding of the laser beam at the tip and the intense quasistatic magnetic field in the cone geometry.The behavior of the relativistic electrons is verified in our 2D-PIC simulations.展开更多
Summary: This study aimed to examine the optimal conditions of laser-induced interstitial ther- motherapy (LITT) via a single-needle delivery system, and the ablation-related pathological and ultra- sonic changes. ...Summary: This study aimed to examine the optimal conditions of laser-induced interstitial ther- motherapy (LITT) via a single-needle delivery system, and the ablation-related pathological and ultra- sonic changes. Ultrasound (US)-guided LITT (EchoLaser system) was performed at the output power of 2--4 Wattage (W) for 1-10 min in ex vivo bovine liver. Based on the results of the ex vivo study, the output power of 3 and 4 W with different durations was applied to in vivo rabbit livers (n=24), and VX2 tumors implanted in the hind limbs of rabbits (n=24). The ablation area was histologically determined by hematoxylin-eosin (HE) staining. Traditional US and contrast enhanced ultrasound (CEUS) were used to evaluate the treatment outcomes. The results showed: (1) In the bovine liver, ablation disruption was grossly seen, including a strip-like ablation crater, a carbonization zone anteriorly along the fiber tip, and a surrounding gray-white coagulation zone. The coagulation area, 1.2 cm in length and 1.0 cm in width, was formed in the bovine liver subjected to the ablation at 3 W for 5 min and 4 W for 4 rain, and it extended slightly with the ablation time. (2) In the rabbit liver, after LITT at 3 W for 3 min and more, the coagulation area with length greater than or equal to 1.2 cm, and width greater than or equal to 1.0 cm, was found. Similar coagulation area was seen in the implanted VX2 carcinoma at 3 W for 5 min. (3) Gross examination of the liver and carcinoma showed three distinct regions: ablation cra- ter/carbonization, coagulation and congestion distributed from the center outwards. (4) Microscopy re- vealed four zones after LITT, including ablation crater/carbonization, coagulation, edema and conges- tion from the center outwards. A large area with coagulative necrosis was observed around a vessel in the peripheral area with edema and hyperemia. (5) The size of coagulation was consistent well to the CEUS findings. It was concluded that EchoLaser system at low power can produce a coagulation area larger than 1.0 cm×1.0 cm during a short time period. The real-time US imaging can be used to effec- tively guide and assess the treatment.展开更多
A kind of absorptive thin film was designed and used in laser welding of SiO2, Si and LiNbO3. This absorptive thin film of three-layer metal-dielectric-metal structure is designed for further reducing the high reflect...A kind of absorptive thin film was designed and used in laser welding of SiO2, Si and LiNbO3. This absorptive thin film of three-layer metal-dielectric-metal structure is designed for further reducing the high reflectance of the Nd:YAG laser beam on the surface of the tin layer that is utilized as solder between the transparent parent materials. The actual absorption of laser energy in experiment exceeds 99%. This combination of absorber and solder transformed the laser energy into heat efficiently and decreased the minimum necessary incident laser power transmitting through the transparent parent materials. As a result, the damage of the parent materials, which is suffered from laser transmission, was avoided; On the other hand, mechanical stability of the welded materials had been improved. Experiment had been made to show the difference between welding with and without the absorptive thin film.展开更多
The influence of an external static field applied in the direction of propagation of a high intensity driving laser pulse on the electron trapping in laser wakefield acceleration is explored. It is shown that, in the ...The influence of an external static field applied in the direction of propagation of a high intensity driving laser pulse on the electron trapping in laser wakefield acceleration is explored. It is shown that, in the case of self-injection, the electric charge accelerated can be enhanced in some physical situations.展开更多
Based on a femtosecond linear accelerator, here we present a study of the use of a groove guide as the FEL interaction structure for high power FEL experiment. The transmission and attenuation characteristics of the d...Based on a femtosecond linear accelerator, here we present a study of the use of a groove guide as the FEL interaction structure for high power FEL experiment. The transmission and attenuation characteristics of the dominant mode in the groove guide are discussed. And the coherent spontaneous emission in the FEL is simulated by Gover theory.展开更多
In laser-guided bomb attacking process,the target indication from the laser target designator is the premise for the bomb to hit the target accurately.Considering the lack of quantitative study of the irradiation area...In laser-guided bomb attacking process,the target indication from the laser target designator is the premise for the bomb to hit the target accurately.Considering the lack of quantitative study of the irradiation area of the laser target designator,this paper,based on the existing aircraft motion model and the laser transmission model,uses two aircraft as respectively the carrier of the laser-guided bomb and the carrier of the laser designator and proposes a method to calculate the global irradiation area of the airborne laser designator.By using the proposed algorithm,the global irradiation area when attacking a large flat target or a large spherical target is simulated respectively.Finally,according to the simulation results,the influences of different factors on the shapes of the irradiation area are discussed in detail.展开更多
An edge emitting laser based on two-dimensional photonic crystal slabs is proposed. The device consists of a square lattice microcavity, which is composed of two structures with the same period but different radius of...An edge emitting laser based on two-dimensional photonic crystal slabs is proposed. The device consists of a square lattice microcavity, which is composed of two structures with the same period but different radius of air-holes, and a waveguide. In the cavity, laser resonance in the inner structure benefits from not only the anomalous dispersion characteristic of the first band-edge at the M point in the first Brillouin-zone but also zero photon states in the outer structure. A line defect waveguide is introduced in the outer structure for extracting photons from the inner cavity. Three-dimensional finite-difference time-domain simulations apparently show the in-plane laser output from the waveguide. The microcavity has an effective mode volume of about 3.2(λ/nslab)^3 for oscillation mode and the quality factor of the device including line defect waveguide is estimated to be as high as 1300.展开更多
文摘AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of high myopia and myopic astigmatism. METHODS: In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE) of -8.11±1.09 diopters (D) received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany) for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI) and tear break-up time (TBUT) were evaluated during a 3-year follow-up. RESULTS: The difference of uncorrected distance visual acuity (UDVA) postoperatively was achieved at lmo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant (t=-1.59, P=-0.13). The postoperative change of SE was 0.89 D in the FS-LASIK group (t=5.76, P=0.00), and 0.14 D in the SMILE group (t=-0.54, P=0.59) from lmo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group (P=0.00), but the coma root mean square (RMS) was higher in the SMILE group (0.59±0.26) than in the FS-LASIK group (0.29±0.14, P=0.00). The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at Imo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. CONCLUSION: Both SMILE and wavefront-guided FS- LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve more stable long-term refractive outcome and better control of early postoperative dry eye as compared to FS-LASIK.
基金Supported by the Research Grant of Guangxi Natural Science Foundation(No.2015GXNSFCB139012No.2017GXNSFBA198320)the Research Grant of Guangxi Technology and Science Agency(No.Z2015316)
文摘AIM: To compare the optical quality after implantation of implantable collamer lens(ICL) and wavefront-guided laser in situ keratomileusis(WG-LASIK).METHODS: The study included 40 eyes of 22 patients with myopia who accepted ICL implantation and 40 eyes of 20 patients with myopia who received WG-LASIK. Before surgery and three months after surgery, the objective scattering index(OSI), the values of modulation transfer function(MTF) cutoff frequency, Strehl ratio, and the Optical Quality Analysis System(OQAS) values(OVs) were accessed. The higher order aberrations(HOAs) data including coma, trefoil, spherical, 2^(nd) astigmatism and tetrafoil were also obtained. For patients with pupil size 〈6 mm, HOAs data were analyzed for 4 mm-pupil diameter. For patients with pupil size ≥6 mm, HOAs data were calculated for 6 mm-pupil diameter. Visual acuity, refraction, pupil size and intraocular pressures were also recorded.RESULTS: In both ICL and WG-LASIK group, significant improvements in visual acuities were found postoperatively, with a significant reduction in spherical equivalent(P〈 0.001). After the ICL implantation, the OSI decreasedslightly from 2.34±1.92 to 2.24±1.18 with no statistical significance(P=0.62). While in WG-LASIK group, the OSI significantly increased from 0.68±0.43 preoperatively to 0.91±0.53 postoperatively(Wilcoxon signed ranks test, P=0.000). None of the mean MTF cutoff frequency, Strehl ratio, OVs showed statistically significant changes in both ICL and WG-LASIK groups. In the ICL group, there were no statistical differences in the total HOAs for either 4 mmpupil or 6 mm-pupil. In the WG-LASIK group, the HOA parameters increased significantly at 4 mm-pupil. The total ocular HOAs, coma, spherical and 2^(nd) astigmatism were 0.12±0.06, 0.06±0.03, 0.00±0.03, 0.02±0.01, respectively. After the operation, these values were increased into 0.16±0.07, 0.08±0.05,-0.04±0.04, 0.03±0.01 respectively(Wilcoxon signed ranks test, all P〈0.05). At 6 mm-pupil, the induction of total HOAs was not statistically significant in the WG-LASIK group. CONCLUSION: ICL implantation has a less disturbance to optical quality than WG-LASIK. The OQAS is a valuable complementary measurement to the wavefront aberrometers in evaluating the optical quality.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 10975121 and 11174259)the Foundation of National Key Laboratory of Plasma Physics
文摘We demonstrated the interaction of a gold cone target with a femto second(fs) laser pulse above the relativistic intensity of 1.37×10 18 μm 2 W/cm 2.Relativistic electrons with energy above 2 MeV were observed.A 25%-40% increase of the electron temperature is achieved compared to the case when a plane gold target is used.The electron temperature increase results from the guiding of the laser beam at the tip and the intense quasistatic magnetic field in the cone geometry.The behavior of the relativistic electrons is verified in our 2D-PIC simulations.
基金Project supported by the National Natural Science Foundation of China (Grant No. 91121019)the National Basic Research Program of China (Grant No. 2013CB632105)
文摘An electrically driven, single-longitudinal-mode GaAs based photonic crystal (PC) ridge waveguide (RWG) laser emitting at around 850 nm is demonstrated. The single-longitudinal-mode lasing characteristic is achieved by introducing the PC to the RWG laser. The triangle PC is etched on both sides of the ridge by photolithography and inductive coupled plasma (ICP) etching. The lasing spectra of the RWG lasers with and without the PC are studied, and the result shows that the PC purifies the longitudinal mode. The power per facet versus current and current-voltage characteristics have also been studied and compared.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11174274,11174279,61205021,11204299,61475152,and 61405194)the State Key Laboratory of Applied Optics,Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sciences
文摘Multi-conjugation adaptive optics(MCAOs) have been investigated and used in the large aperture optical telescopes for high-resolution imaging with large field of view(FOV).The atmospheric tomographic phase reconstruction and projection of three-dimensional turbulence volume onto wavefront correctors,such as deformable mirrors(DMs) or liquid crystal wavefront correctors(LCWCs),is a very important step in the data processing of an MCAO's controller.In this paper,a method according to the wavefront reconstruction performance of MCAO is presented to evaluate the optimized configuration of multi laser guide stars(LGSs) and the reasonable conjugation heights of LCWCs.Analytical formulations are derived for the different configurations and are used to generate optimized parameters for MCAO.Several examples are given to demonstrate our LGSs configuration optimization method.Compared with traditional methods,our method has minimum wavefront tomographic error,which will be helpful to get higher imaging resolution at large FOV in MCAO.
文摘A theory of the far spatial coherent-suppressed single-peak field distribution of a rectangular wave-guide CO2 laser is presented. The theoretical analysis shows that a rectangular wave-guide laser can have an output intensity distribution in far field similar to that produced from a wave-guide array laser, which is in agreement with the experimental result. A single-peak mode output is obtained within 5 metres. The experimental far-field spread angle in the bigger-Fresnel number direction is 0.63 mrad, compared to the calculated one, 0.6 mrad, and when the length of the laser resonator is changed, a double-peak or multi-peak in far-field distribution of the laser is obtained.
基金supported by the National Natural Science Foundation of China (Grant Nos 10734130,10634020,60621063)National Basic Research Programme of China (Gant No 2007CB815101)
文摘This paper demonstrates the triggering and guiding of the stationary high voltage (HV) discharges at 5-40kV by using plasma filaments generated by femtosecond laser pulses in air. A significant reduction of the breakdown voltage threshold due to the pre-ionization of the air gap by laser filamentation is observed. The discharge experiments are performed by using laser pulses with different energy from 15-60 mJ. The electron density of filaments is detected by sonography method. The influence of the electron density of laser filaments on the triggering and guiding HV discharge is experimentally investigated. The results have shown that the behaviour of plasma filaments can strongly affect the efficiency of triggering and guiding HV discharge.
文摘A three-dimensional simulation of a steady-state amplifier model of a long-wavelength free-electron laser (FEL) with realizable helical wiggler and ion-channel guiding is presented. The set of coupled nonlinear differential equations for electron orbits and fields of TE 11 mode in a cylindrical waveguide are solved numerically by the Runge–Kutta algorithm with averages calculated by the Gaussian quadrature technique. Self-fields and space-charge effects are neglected, and the electron beam is assumed to be cold and slippage is ignored. The parameters correspond to the Compton regime. Evolution of the radiation power and growth rate along the wiggler is studied. Ion-channel density is chosen to obtain optimum efficiency. Simulations are preformed for the FEL operating in the neighborhood of 35 GHz and 16.5 GHz for the electron beam energies of 250 keV and 400 keV, respectively. The result of the saturated efficiency was found to be in good agreement with the simple estimation based on the phase-trapping model.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 10804031, 10904037, 10434060, 10674047,11034002, and 10904060)the National Basic Research Program of China (Grant Nos. 2006CB921604 and 2011CB921602)+2 种基金the Basic Key Program of Shanghai Municipality, China (Grant No. 07JC14017)the Shanghai Leading Academic Discipline Project,China (Grant No. B408)the Jiangsu Provincial Projects for Postdoctoral Research Funds, China (Grant No. 0802009B)
文摘A novel scheme for guiding arbitrary buffer-gas cooled neutral molecules in a hollow optical fiber (HOF) using a red-detuned HEll mode is proposed and analysed theoretically. We give the electromagnetic field distribution of the HEll mode in the HOF and calculate the optical potential of an 12 molecule, and study the molecule guiding mechanism using a classical Monte Carlo simulation. Using a 6 kW input laser, an S-shape HOF with a 2 cm curvature radius for both bends, and an input molecular beam with a transverse temperature of 0.5 K and longitudinal temperature of 5 K, we obtain a guiding efficiency of -0.126% for the scheme, and the transverse and longitudinal temperatures of the guided molecular beam are 1.9 mK and 0.5 K, respectively.
文摘The Australian first working sodium guide star laser system has been designed and developed for various astronomical and space-related applications. A completely diode-pumped pulsed system was developed initially followed by a largely fiber-based continuous wave (CW) system operating at 589 nm achieved through a unique wavelength conversion scheme by combining 1342 and 1050 nm through a sum frequency generation process. For the CW system, single-mode laser beams at both 1342 and 1050 nm are achieved from fiber-based seed oscillators and fiber amplifiers. The output power of ~25 W at 1342 nm is achieved from a single frequency fiber Raman amplifier. Output power up to 70 W at 1050 nm is achieved from a Yb-doped fiber pre-amplifier followed by a Yb-doped fiber power amplifier. For the sum frequency generation process, optimum focusing parameters are evaluated and determined. The CW system has generated more than 20 W output power at 589 nm, a circularly polarised beam with a good beam quality, spectral linewidth ≤ 2 MHz, and the laser output locked on the sodium D2 line at 589.159 nm. The system has been successfully demonstrated at EOS Space Research Centre, Mt Stromlo, Canberra, and become the Australian first working sodium guide star laser system.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11174274,11174279,61205021,11204299,61475152,and 61405194)State Key Laboratory of Applied Optics,Changchun Institute of Optics,Fine Mechanics and Physics,Chinese Academy of Sciences
文摘Adaptive optics(AO) systems are widespread and considered as an essential part of any large aperture telescope for obtaining a high resolution imaging at present.To enlarge the imaging field of view(FOV),multi-laser guide stars(LGSs) are currently being investigated and used for the large aperture optical telescopes.LGS measurement is necessary and pivotal to obtain the cumulative phase distortion along a target in the multi-LGSs AO system.We propose a high precision phase reconstruction algorithm to estimate the phase for a target with an uncertain turbulence profile based on the interpolation.By comparing with the conventional average method,the proposed method reduces the root mean square(RMS) error from 130 nm to 85 nm with a 30% reduction for narrow FOV.We confirm that such phase reconstruction algorithm is validated for both narrow field AO and wide field AO.
文摘Mechanized construction of micro-catchments for water harvesting (WH) was successfully tested in the Badia (dry rangeland) areas in Syria and Jordan, using the "Vallerani" plow, model Delfino (50 MI/CM), manufactured by Nardi, Italy. The plow was able to construct intermittent and continuous contour ridges, and could potentially be used to rehabilitate degraded rangelands. However, one major issue for large-scale implementation is the high cost and time required to manually identify contours for the plow to follow. Most existing auto-guiding systems, as usually used in road construction and agricultural land leveling, were expensive or impractical. The objective, therefore, was to add, adapt, and evaluate an auto-guiding system to enable a tractor to follow contours without demarcation through conventional surveying. A low-cost Contour Laser Guiding (CLG) system, with specifications that suit the contour ridging in undulating topographic conditions of dry rangelands, was chosen, adapted, mounted, and tested, under actual field conditions. The system consisted mainly of a portable laser transmitter and a tractor-mounted receiver, connected to a guidance display panel. The system was field-tested on 95 ha of land where the system capacity was determined under different terrains, slopes (1-8%), and ridge spacings (4-12 m). The easy adaptation and implementation of the CLG to the "Vallerani" unit tripled the system capacity, improved efficiency and precision, and substantially reduced the cost of constructing micro-catchments for WH. The system is recommended for large-scale rangeland rehabilitation projects in the dry areas, not only in West Asia, but worldwide.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 10975121 and 11174259)the Foundation of National Key Laboratory of Plasma Physics
文摘We demonstrated the interaction of a gold cone target with a femto second(fs) laser pulse above the relativistic intensity of 1.37×10 18 μm 2 W/cm 2.Relativistic electrons with energy above 2 MeV were observed.A 25%-40% increase of the electron temperature is achieved compared to the case when a plane gold target is used.The electron temperature increase results from the guiding of the laser beam at the tip and the intense quasistatic magnetic field in the cone geometry.The behavior of the relativistic electrons is verified in our 2D-PIC simulations.
基金supported by grants from the National Natural Science Foundation of China(No.81000616)the Natural Science Foundation of Hubei Province,China(No.2009cdb264 and No.2012ffb02526)
文摘Summary: This study aimed to examine the optimal conditions of laser-induced interstitial ther- motherapy (LITT) via a single-needle delivery system, and the ablation-related pathological and ultra- sonic changes. Ultrasound (US)-guided LITT (EchoLaser system) was performed at the output power of 2--4 Wattage (W) for 1-10 min in ex vivo bovine liver. Based on the results of the ex vivo study, the output power of 3 and 4 W with different durations was applied to in vivo rabbit livers (n=24), and VX2 tumors implanted in the hind limbs of rabbits (n=24). The ablation area was histologically determined by hematoxylin-eosin (HE) staining. Traditional US and contrast enhanced ultrasound (CEUS) were used to evaluate the treatment outcomes. The results showed: (1) In the bovine liver, ablation disruption was grossly seen, including a strip-like ablation crater, a carbonization zone anteriorly along the fiber tip, and a surrounding gray-white coagulation zone. The coagulation area, 1.2 cm in length and 1.0 cm in width, was formed in the bovine liver subjected to the ablation at 3 W for 5 min and 4 W for 4 rain, and it extended slightly with the ablation time. (2) In the rabbit liver, after LITT at 3 W for 3 min and more, the coagulation area with length greater than or equal to 1.2 cm, and width greater than or equal to 1.0 cm, was found. Similar coagulation area was seen in the implanted VX2 carcinoma at 3 W for 5 min. (3) Gross examination of the liver and carcinoma showed three distinct regions: ablation cra- ter/carbonization, coagulation and congestion distributed from the center outwards. (4) Microscopy re- vealed four zones after LITT, including ablation crater/carbonization, coagulation, edema and conges- tion from the center outwards. A large area with coagulative necrosis was observed around a vessel in the peripheral area with edema and hyperemia. (5) The size of coagulation was consistent well to the CEUS findings. It was concluded that EchoLaser system at low power can produce a coagulation area larger than 1.0 cm×1.0 cm during a short time period. The real-time US imaging can be used to effec- tively guide and assess the treatment.
基金This research was supported by Hanslaser Ltd,National 863(2003AA311022)Project of ChinaNational 973(2003CB314901)Project of China
文摘A kind of absorptive thin film was designed and used in laser welding of SiO2, Si and LiNbO3. This absorptive thin film of three-layer metal-dielectric-metal structure is designed for further reducing the high reflectance of the Nd:YAG laser beam on the surface of the tin layer that is utilized as solder between the transparent parent materials. The actual absorption of laser energy in experiment exceeds 99%. This combination of absorber and solder transformed the laser energy into heat efficiently and decreased the minimum necessary incident laser power transmitting through the transparent parent materials. As a result, the damage of the parent materials, which is suffered from laser transmission, was avoided; On the other hand, mechanical stability of the welded materials had been improved. Experiment had been made to show the difference between welding with and without the absorptive thin film.
文摘The influence of an external static field applied in the direction of propagation of a high intensity driving laser pulse on the electron trapping in laser wakefield acceleration is explored. It is shown that, in the case of self-injection, the electric charge accelerated can be enhanced in some physical situations.
文摘Based on a femtosecond linear accelerator, here we present a study of the use of a groove guide as the FEL interaction structure for high power FEL experiment. The transmission and attenuation characteristics of the dominant mode in the groove guide are discussed. And the coherent spontaneous emission in the FEL is simulated by Gover theory.
基金supported by the Aeronautical Science Foundation of China(ASFC-20135153031ASFC-20135553035ASFC-2017ZC53033)
文摘In laser-guided bomb attacking process,the target indication from the laser target designator is the premise for the bomb to hit the target accurately.Considering the lack of quantitative study of the irradiation area of the laser target designator,this paper,based on the existing aircraft motion model and the laser transmission model,uses two aircraft as respectively the carrier of the laser-guided bomb and the carrier of the laser designator and proposes a method to calculate the global irradiation area of the airborne laser designator.By using the proposed algorithm,the global irradiation area when attacking a large flat target or a large spherical target is simulated respectively.Finally,according to the simulation results,the influences of different factors on the shapes of the irradiation area are discussed in detail.
文摘An edge emitting laser based on two-dimensional photonic crystal slabs is proposed. The device consists of a square lattice microcavity, which is composed of two structures with the same period but different radius of air-holes, and a waveguide. In the cavity, laser resonance in the inner structure benefits from not only the anomalous dispersion characteristic of the first band-edge at the M point in the first Brillouin-zone but also zero photon states in the outer structure. A line defect waveguide is introduced in the outer structure for extracting photons from the inner cavity. Three-dimensional finite-difference time-domain simulations apparently show the in-plane laser output from the waveguide. The microcavity has an effective mode volume of about 3.2(λ/nslab)^3 for oscillation mode and the quality factor of the device including line defect waveguide is estimated to be as high as 1300.