Sub-external cavity effect and elimination method in laser self-mixing interference wave plate measurement system
1
作者 牛海莎 牛燕雄 宋建军 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第2期349-354,共6页
Laser self-mixing interference(SMI) wave plate measurement method is a burgeoning technique for its simplicity and efficiency. But for the non-coated sample, the reflected light from the surface can seriously affect... Laser self-mixing interference(SMI) wave plate measurement method is a burgeoning technique for its simplicity and efficiency. But for the non-coated sample, the reflected light from the surface can seriously affect the measurement results.To analyze the reason theoretically, a self-consistent model for laser operation with a sub-external and an external cavity is established, and the sub-external cavity formed by the sample and a cavity mirror is proved to be the main error source.A synchronous tuning method is proposed to eliminate the sub-external cavity effect. Experiments are carried out on the synchronously tuning double external cavities self-mixing interference system, and the error of the system is in the range of -0.435°~0.387° compared with the ellipsometer. The research plays an important role in improving the performance and enlarging the application range of the laser self-mixing interference system. 展开更多
关键词 self-mixing interference non-coated wave plate measurement self-consistent model