We measure and calculate the aerial image modulation (AIM) of human retina for visible wavelengths based on the individual eye model. By employing the optical design software ZEMAX, we obtain the modulation transfer...We measure and calculate the aerial image modulation (AIM) of human retina for visible wavelengths based on the individual eye model. By employing the optical design software ZEMAX, we obtain the modulation transfer function (MTF) of human eye in visible wavelengths. Using CSV-1000 and VAF-1000, the contrast sensitivity function (CSF) and the visual acuity (VA) for the same eye are measured. Then the AIM of human retina could be acquired by the relations between MTF and CSF and between MTF and VA. The AIM of human retina is independent of MTF, and the values of AIM for normal eyes (without retina disease) are similar, so the assembly average for large numbers of normal eyes can be a standard AIM curve, which is helpful for the diagnosis of diseases in the retina system.展开更多
A scanning Hartmann test method is proposed and its measurement principle is described. The scanning Hartmann test setup is formed by modifying the Hartmann screen of the conventional Hartmann test setup. With the rot...A scanning Hartmann test method is proposed and its measurement principle is described. The scanning Hartmann test setup is formed by modifying the Hartmann screen of the conventional Hartmann test setup. With the rotation of the scanning Hartmann screen and the improved hole arrangement, the whole information of the lens to be tested in the full aperture can be obtained. The measurement accuracy of the aberration is improved and the local error of the lens can be got. In the method, no change of the Hartmann screen is needed for measuring the lenses of different aperture sizes. Experimental results of aberration measurements of two lenses are given to verify the usefulness of the setup.展开更多
水下光学成像是重要的水下探测方式。现有水下相机成像检测方法受到水体本身以及测量方法的影响,难以准确进行成像分辨率检测。提出了基于水下平行光管的水下相机成像分辨率检测技术,通过在水中产生平行光束,直接对水下相机成像分辨率...水下光学成像是重要的水下探测方式。现有水下相机成像检测方法受到水体本身以及测量方法的影响,难以准确进行成像分辨率检测。提出了基于水下平行光管的水下相机成像分辨率检测技术,通过在水中产生平行光束,直接对水下相机成像分辨率进行检测。通过仿真得出:水下平行光管在水中可见光和空气中单波长的调制传递函数(Modulation Transfer Function, MTF)基本一致。利用这一结论,提出了水下平行光管空气中装调检测的方法。针对实验室所研制的一款水下相机开展实验测试,其在水中可见光与空气中635 m光源照明条件下的分辨率相同。实验结果表明,所提出的基于水下平行光管的水下相机成像分辨率检测方法可有效消除水体对分辨率测量的影响,实现水下相机成像分辨率的准确测量。展开更多
In this paper we present the recent research results in the field of vision correction and supernormal vision according to the actual measurements of the wave-front aberrations and the corneal surface topography,the c...In this paper we present the recent research results in the field of vision correction and supernormal vision according to the actual measurements of the wave-front aberrations and the corneal surface topography,the clinical detection of the visual function and the laser corneal refractive surgery,and the optimization of the optical system. These include the features of the aberrations of human eye with different pupil sizes,different fields of view and temporal accommodation,the influence of the polychromatic illumination of the visible wavelength on the supernormal vision,and the effect of the existing laser corneal refractive surgery on the wave-front ab-errations of the eye. It is shown that the wave-front aberration of human eye is of temporal variation and of synthesis with multi impact factors. To achieve super-normal vision,an optimum engineering data for the customized laser corneal sur-gery should be firstly acquired,which may involve the dynamic free-form optical surface. Although the myopia can be corrected by the laser in situ keratomileusis(LASIK) in a certain degree,it brings about negative effects under scotopic condi-tions.展开更多
基金Supported by the Key Project of the National Natural Science Foundation of China under Grant No 60438030, the Key Research Foundation of Scientific and Technical Committee of Tianjin City of China under Grant No 033183711, and the Specialized Research Fund for the Doctoral Programme of Higher Education of China under Grant No 20050055002.
文摘We measure and calculate the aerial image modulation (AIM) of human retina for visible wavelengths based on the individual eye model. By employing the optical design software ZEMAX, we obtain the modulation transfer function (MTF) of human eye in visible wavelengths. Using CSV-1000 and VAF-1000, the contrast sensitivity function (CSF) and the visual acuity (VA) for the same eye are measured. Then the AIM of human retina could be acquired by the relations between MTF and CSF and between MTF and VA. The AIM of human retina is independent of MTF, and the values of AIM for normal eyes (without retina disease) are similar, so the assembly average for large numbers of normal eyes can be a standard AIM curve, which is helpful for the diagnosis of diseases in the retina system.
文摘A scanning Hartmann test method is proposed and its measurement principle is described. The scanning Hartmann test setup is formed by modifying the Hartmann screen of the conventional Hartmann test setup. With the rotation of the scanning Hartmann screen and the improved hole arrangement, the whole information of the lens to be tested in the full aperture can be obtained. The measurement accuracy of the aberration is improved and the local error of the lens can be got. In the method, no change of the Hartmann screen is needed for measuring the lenses of different aperture sizes. Experimental results of aberration measurements of two lenses are given to verify the usefulness of the setup.
文摘水下光学成像是重要的水下探测方式。现有水下相机成像检测方法受到水体本身以及测量方法的影响,难以准确进行成像分辨率检测。提出了基于水下平行光管的水下相机成像分辨率检测技术,通过在水中产生平行光束,直接对水下相机成像分辨率进行检测。通过仿真得出:水下平行光管在水中可见光和空气中单波长的调制传递函数(Modulation Transfer Function, MTF)基本一致。利用这一结论,提出了水下平行光管空气中装调检测的方法。针对实验室所研制的一款水下相机开展实验测试,其在水中可见光与空气中635 m光源照明条件下的分辨率相同。实验结果表明,所提出的基于水下平行光管的水下相机成像分辨率检测方法可有效消除水体对分辨率测量的影响,实现水下相机成像分辨率的准确测量。
基金Supported by the National Natural Science Foundation of China (Grant No. 60438030)the Key Research Foundation of Scientific and Technical Committee of Tianjin City of China (Grant No. 033183711)
文摘In this paper we present the recent research results in the field of vision correction and supernormal vision according to the actual measurements of the wave-front aberrations and the corneal surface topography,the clinical detection of the visual function and the laser corneal refractive surgery,and the optimization of the optical system. These include the features of the aberrations of human eye with different pupil sizes,different fields of view and temporal accommodation,the influence of the polychromatic illumination of the visible wavelength on the supernormal vision,and the effect of the existing laser corneal refractive surgery on the wave-front ab-errations of the eye. It is shown that the wave-front aberration of human eye is of temporal variation and of synthesis with multi impact factors. To achieve super-normal vision,an optimum engineering data for the customized laser corneal sur-gery should be firstly acquired,which may involve the dynamic free-form optical surface. Although the myopia can be corrected by the laser in situ keratomileusis(LASIK) in a certain degree,it brings about negative effects under scotopic condi-tions.