期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
A Fault Diagnosis Method Based on Wavelet Singular Entropy and SVM for VSC-HVDC Converter 被引量:1
1
作者 XU Bingbing WANG Tianzhen +1 位作者 LUO Kai GAO Diju 《Wuhan University Journal of Natural Sciences》 CAS CSCD 2020年第4期359-368,共10页
The converter is the core component of voltage source converter-high voltage direct current(VSC-HVDC),which is related to the stable operation of the system.The converter has a complex structure where the accuracy of ... The converter is the core component of voltage source converter-high voltage direct current(VSC-HVDC),which is related to the stable operation of the system.The converter has a complex structure where the accuracy of feature extraction is low,and the computation speed of traditional fault diagnosis strategies is slow.To solve this problem,a fault diagnosis strategy based on wavelet singular entropy(WSE)and support vector machine(SVM)was proposed.This method includes fault and label setting,converter fault feature extraction based on wavelet singular entropy,and converter fault classification based on support vector machine.The DC-side voltage signal was used as the detection signal,and the wavelet singular entropy was used for feature extraction to avoid noise interference.The classification is based on SVM.The experimental verification in PSCAD simulation proved that the method has better fault diagnosis ability for various faults and meets the needs of converter fault diagnosis. 展开更多
关键词 CONVERTER wavelet singular entropy fault diagnosis support vector machine
原文传递
Fault Feeder Identification in Non-effectively Grounded Distribution Network with Secondary Earth Fault 被引量:1
2
作者 Shu Zhang Tianlei Zang +1 位作者 Wenhai Zhang Xianyong Xiao 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第5期1137-1148,共12页
Secondary earth faults occur frequently in power distribution networks under harsh weather conditions.Owing to its characteristics,a secondary earth fault is typically hidden within the transient of the first fault.Th... Secondary earth faults occur frequently in power distribution networks under harsh weather conditions.Owing to its characteristics,a secondary earth fault is typically hidden within the transient of the first fault.Therefore,most researchers tend to focus on a feeder with single fault while disregarding secondary faults.This paper presents a fault feeder identification method that considers secondary earth faults in a non-effectively grounded distribution network.First,the wavelet singular entropy method is used to detect a secondary fault event.This method can identify the moment at which a secondary fault occurs.The zero-sequence current data can be categorized into two fault stages.The first and second fault stages correspond to the first and secondary faults,respectively.Subsequently,a similarity matrix containing the time-frequency transient information of the zero-sequence current at the two fault stages is defined to identify the fault feeders.Finally,to confirm the effectiveness and reliability of the proposed method,we conduct simulation experiments and an adaptability analysis based on an electromagnetic transient program. 展开更多
关键词 Secondary earth fault non-effectively grounded distribution network wavelet singular entropy similarity matrix zero-sequence current
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部