Recently,as recognizing emotion has been one of the hallmarks of affective computing,more attention has been paid to physiological signals for emotion recognition.This paper presented an approach to emotion recognitio...Recently,as recognizing emotion has been one of the hallmarks of affective computing,more attention has been paid to physiological signals for emotion recognition.This paper presented an approach to emotion recognition using ElectroCardioGraphy(ECG) signals from multiple subjects.To collect reliable affective ECG data,we applied an arousal method by movie clips to make subjects experience specific emotions without external interference.Through precise location of P-QRS-T wave by continuous wavelet transform,an amount of ECG features was extracted sufficiently.Since feature selection is a combination optimization problem,Improved Binary Particle Swarm Optimization(IBPSO) based on neighborhood search was applied to search out effective features to improve classification results of emotion states with the help of fisher or K-Nearest Neighbor(KNN) classifier.In the experiment,it is shown that the approach is successful and the effective features got from ECG signals can express emotion states excellently.展开更多
The electrocardiogram (ECG) signal used for diagnosis and patient monitoring, has recently emerged as a biometric recognition tool. Indeed, ECG signal changes from one person to another according to health status, hea...The electrocardiogram (ECG) signal used for diagnosis and patient monitoring, has recently emerged as a biometric recognition tool. Indeed, ECG signal changes from one person to another according to health status, heart geometry and anatomy among other factors. This paper forms a comparative study between different identification techniques and their performances. Previous works in this field referred to methodologies implementing either set of fiducial or set non-fiducial features. In this study we show a comparison of the same data using a fiducial feature set and a non-fiducial feature set based on statistical calculation of wavelet coefficient. High identification rates were measured in both cases, non-fiducial using Discrete Meyer (dmey) wavelet outperformed the rest at 98.65.展开更多
This paper presents a hybrid technique for the compression of ECG signals based on DWT and exploiting the correlation between signal samples. It incorporates Discrete Wavelet Transform (DWT), Differential Pulse Code M...This paper presents a hybrid technique for the compression of ECG signals based on DWT and exploiting the correlation between signal samples. It incorporates Discrete Wavelet Transform (DWT), Differential Pulse Code Modulation (DPCM), and run-length coding techniques for the compression of different parts of the signal;where lossless compression is adopted in clinically relevant parts and lossy compression is used in those parts that are not clinically relevant. The proposed compression algorithm begins by segmenting the ECG signal into its main components (P-waves, QRS-complexes, T-waves, U-waves and the isoelectric waves). The resulting waves are grouped into Region of Interest (RoI) and Non Region of Interest (NonRoI) parts. Consequently, lossless and lossy compression schemes are applied to the RoI and NonRoI parts respectively. Ideally we would like to compress the signal losslessly, but in many applications this is not an option. Thus, given a fixed bit budget, it makes sense to spend more bits to represent those parts of the signal that belong to a specific RoI and, thus, reconstruct them with higher fidelity, while allowing other parts to suffer larger distortion. For this purpose, the correlation between the successive samples of the RoI part is utilized by adopting DPCM approach. However the NonRoI part is compressed using DWT, thresholding and coding techniques. The wavelet transformation is used for concentrating the signal energy into a small number of transform coefficients. Compression is then achieved by selecting a subset of the most relevant coefficients which afterwards are efficiently coded. Illustrative examples are given to demonstrate thresholding based on energy packing efficiency strategy, coding of DWT coefficients and data packetizing. The performance of the proposed algorithm is tested in terms of the compression ratio and the PRD distortion metrics for the compression of 10 seconds of data extracted from records 100 and 117 of MIT-BIH database. The obtained results revealed that the proposed technique possesses higher compression ratios and lower PRD compared to the other wavelet transformation techniques. The principal advantages of the proposed approach are: 1) the deployment of different compression schemes to compress different ECG parts to reduce the correlation between consecutive signal samples;and 2) getting high compression ratios with acceptable reconstruction signal quality compared to the recently published results.展开更多
Many dynamic signals of mining machines are transient, such as load signals when roadheader’s cutting head being cut-in or cut-out and response signals produced by these loads.For these transient signals, the traditi...Many dynamic signals of mining machines are transient, such as load signals when roadheader’s cutting head being cut-in or cut-out and response signals produced by these loads.For these transient signals, the traditional Fourier analysis method is quite inadequate.The limitations of analysis, resolution by using Short-Time Fourier Transform (STFT) on them were discussed in this paper. Because of wavelet transform having the characteristics of flexible window and multiresolution analysis, we try to apply it to analyse these transient signal. In order to give a pratical example,using D18 wavelet and Mallat’s tree algorithm with MATLAB, the discrete wavelet transform was calculated for the simulating response signals of a three-degree-of freedom vibration system when it Was under impulse and random excitations. The results of the wavelet transform made clear its effectiveness and superiority in analysing transient signals of mining machines.展开更多
基金Supported by the National Natural Science Foundation of China (No.60873143)the National Key Subject Foundation for Basic Psychology (No.NKSF07003)
文摘Recently,as recognizing emotion has been one of the hallmarks of affective computing,more attention has been paid to physiological signals for emotion recognition.This paper presented an approach to emotion recognition using ElectroCardioGraphy(ECG) signals from multiple subjects.To collect reliable affective ECG data,we applied an arousal method by movie clips to make subjects experience specific emotions without external interference.Through precise location of P-QRS-T wave by continuous wavelet transform,an amount of ECG features was extracted sufficiently.Since feature selection is a combination optimization problem,Improved Binary Particle Swarm Optimization(IBPSO) based on neighborhood search was applied to search out effective features to improve classification results of emotion states with the help of fisher or K-Nearest Neighbor(KNN) classifier.In the experiment,it is shown that the approach is successful and the effective features got from ECG signals can express emotion states excellently.
文摘The electrocardiogram (ECG) signal used for diagnosis and patient monitoring, has recently emerged as a biometric recognition tool. Indeed, ECG signal changes from one person to another according to health status, heart geometry and anatomy among other factors. This paper forms a comparative study between different identification techniques and their performances. Previous works in this field referred to methodologies implementing either set of fiducial or set non-fiducial features. In this study we show a comparison of the same data using a fiducial feature set and a non-fiducial feature set based on statistical calculation of wavelet coefficient. High identification rates were measured in both cases, non-fiducial using Discrete Meyer (dmey) wavelet outperformed the rest at 98.65.
文摘This paper presents a hybrid technique for the compression of ECG signals based on DWT and exploiting the correlation between signal samples. It incorporates Discrete Wavelet Transform (DWT), Differential Pulse Code Modulation (DPCM), and run-length coding techniques for the compression of different parts of the signal;where lossless compression is adopted in clinically relevant parts and lossy compression is used in those parts that are not clinically relevant. The proposed compression algorithm begins by segmenting the ECG signal into its main components (P-waves, QRS-complexes, T-waves, U-waves and the isoelectric waves). The resulting waves are grouped into Region of Interest (RoI) and Non Region of Interest (NonRoI) parts. Consequently, lossless and lossy compression schemes are applied to the RoI and NonRoI parts respectively. Ideally we would like to compress the signal losslessly, but in many applications this is not an option. Thus, given a fixed bit budget, it makes sense to spend more bits to represent those parts of the signal that belong to a specific RoI and, thus, reconstruct them with higher fidelity, while allowing other parts to suffer larger distortion. For this purpose, the correlation between the successive samples of the RoI part is utilized by adopting DPCM approach. However the NonRoI part is compressed using DWT, thresholding and coding techniques. The wavelet transformation is used for concentrating the signal energy into a small number of transform coefficients. Compression is then achieved by selecting a subset of the most relevant coefficients which afterwards are efficiently coded. Illustrative examples are given to demonstrate thresholding based on energy packing efficiency strategy, coding of DWT coefficients and data packetizing. The performance of the proposed algorithm is tested in terms of the compression ratio and the PRD distortion metrics for the compression of 10 seconds of data extracted from records 100 and 117 of MIT-BIH database. The obtained results revealed that the proposed technique possesses higher compression ratios and lower PRD compared to the other wavelet transformation techniques. The principal advantages of the proposed approach are: 1) the deployment of different compression schemes to compress different ECG parts to reduce the correlation between consecutive signal samples;and 2) getting high compression ratios with acceptable reconstruction signal quality compared to the recently published results.
文摘Many dynamic signals of mining machines are transient, such as load signals when roadheader’s cutting head being cut-in or cut-out and response signals produced by these loads.For these transient signals, the traditional Fourier analysis method is quite inadequate.The limitations of analysis, resolution by using Short-Time Fourier Transform (STFT) on them were discussed in this paper. Because of wavelet transform having the characteristics of flexible window and multiresolution analysis, we try to apply it to analyse these transient signal. In order to give a pratical example,using D18 wavelet and Mallat’s tree algorithm with MATLAB, the discrete wavelet transform was calculated for the simulating response signals of a three-degree-of freedom vibration system when it Was under impulse and random excitations. The results of the wavelet transform made clear its effectiveness and superiority in analysing transient signals of mining machines.