The utilization of renewable energy in sending-end power grids is increasing rapidly,which brings difficulties to voltage control.This paper proposes a coordinated voltage control strategy based on model predictive co...The utilization of renewable energy in sending-end power grids is increasing rapidly,which brings difficulties to voltage control.This paper proposes a coordinated voltage control strategy based on model predictive control(MPC)for the renewable energy power plants of wind and solar power connected to a weak sending-end power grid(WSPG).Wind turbine generators(WTGs),photovoltaic arrays(PVAs),and a static synchronous compensator are coordinated to maintain voltage within a feasible range during operation.This results in the full use of the reactive power capability of WTGs and PVAs.In addition,the impact of the active power outputs of WTGs and PVAs on voltage control are considered because of the high R/X ratio of a collector system.An analytical method is used for calculating sensitivity coefficients to improve computation efficiency.A renewable energy power plant with 80 WTGs and 20 PVAs connected to a WSPG is used to verify the proposed voltage control strategy.Case studies show that the coordinated voltage control strategy can achieve good voltage control performance,which improves the voltage quality of the entire power plant.展开更多
Modeling method for the current control loop of a grid-connected PWM inverter with the LCL output filter was discussed.Firstly,the current control loop with the LCL inverter-side current as feedback was established.Th...Modeling method for the current control loop of a grid-connected PWM inverter with the LCL output filter was discussed.Firstly,the current control loop with the LCL inverter-side current as feedback was established.Then,parameters of PI controller were calculated on the basis of an equivalent controlled object.Finally,Norton equivalent circuit for the current control loop of grid-connected system was derived by integrating one control equation,which connected the PWM inverter output voltage and the LCL inverter-side current,with two circuit equations,separately using the LCL inverter-side current and the injected current as loop currents.With the induced Norton equivalent circuit,system-level resonant and unstable issues on real grid-connected system applied in weak distributed power systems can be easily analyzed.The validity of substituting Norton equivalent circuit for grid-connected system is verified by simulation and experiment.展开更多
新能源汇集经柔性直流输电(voltage source converter based high voltage direct current,VSC-HVDC)技术送出是促进新能源消纳的有效方式。但新能源渗透率的持续增加导致电网强度不断下降,采用传统跟网型(grid-following,GFL)换流技术...新能源汇集经柔性直流输电(voltage source converter based high voltage direct current,VSC-HVDC)技术送出是促进新能源消纳的有效方式。但新能源渗透率的持续增加导致电网强度不断下降,采用传统跟网型(grid-following,GFL)换流技术已无法满足系统稳定运行需求。为提高系统弱电网适应性,满足大规模新能源接入弱同步支撑柔直系统应用场景需求,提出在柔直系统送端换流站采用VSG控制策略。首先,建立整流侧控制小信号数学模型,利用根轨迹法深入研究虚拟阻抗对系统稳定性的影响。其次,提出利用交流电压变化率及电压差值等电气量构建虚拟电抗自适应调整项的改进VSG控制算法,在保证系统等效阻抗呈感性的同时,可提高送端交流系统的等效短路比,达到改善系统整体性能的效果。最后,通过PSCAD/EMTDC电磁暂态仿真验证所提控制策略的有效性。展开更多
基金supported by National Natural Science Foundation Joint Key Project of China(2016YFB0900900).
文摘The utilization of renewable energy in sending-end power grids is increasing rapidly,which brings difficulties to voltage control.This paper proposes a coordinated voltage control strategy based on model predictive control(MPC)for the renewable energy power plants of wind and solar power connected to a weak sending-end power grid(WSPG).Wind turbine generators(WTGs),photovoltaic arrays(PVAs),and a static synchronous compensator are coordinated to maintain voltage within a feasible range during operation.This results in the full use of the reactive power capability of WTGs and PVAs.In addition,the impact of the active power outputs of WTGs and PVAs on voltage control are considered because of the high R/X ratio of a collector system.An analytical method is used for calculating sensitivity coefficients to improve computation efficiency.A renewable energy power plant with 80 WTGs and 20 PVAs connected to a WSPG is used to verify the proposed voltage control strategy.Case studies show that the coordinated voltage control strategy can achieve good voltage control performance,which improves the voltage quality of the entire power plant.
基金Project(51307009)supported by the National Natural Science Foundation of ChinaProject(12JJ4045)supported by Hunan Provincial Natural Science Foundation,China+2 种基金Project(2011KFJJ003)supported by the Key Laboratory for Power Technology of Renewable Energy Sources of Hunan Province,ChinaProject(2011kfj14)supported by the Fund of Key Laboratory of Hunan Province about Power System Operation and Control,ChinaProject(454.13S-20)supported by the Enterprises’Postdoctoral Funds of Pudong Area of Shanghai,China
文摘Modeling method for the current control loop of a grid-connected PWM inverter with the LCL output filter was discussed.Firstly,the current control loop with the LCL inverter-side current as feedback was established.Then,parameters of PI controller were calculated on the basis of an equivalent controlled object.Finally,Norton equivalent circuit for the current control loop of grid-connected system was derived by integrating one control equation,which connected the PWM inverter output voltage and the LCL inverter-side current,with two circuit equations,separately using the LCL inverter-side current and the injected current as loop currents.With the induced Norton equivalent circuit,system-level resonant and unstable issues on real grid-connected system applied in weak distributed power systems can be easily analyzed.The validity of substituting Norton equivalent circuit for grid-connected system is verified by simulation and experiment.
文摘新能源汇集经柔性直流输电(voltage source converter based high voltage direct current,VSC-HVDC)技术送出是促进新能源消纳的有效方式。但新能源渗透率的持续增加导致电网强度不断下降,采用传统跟网型(grid-following,GFL)换流技术已无法满足系统稳定运行需求。为提高系统弱电网适应性,满足大规模新能源接入弱同步支撑柔直系统应用场景需求,提出在柔直系统送端换流站采用VSG控制策略。首先,建立整流侧控制小信号数学模型,利用根轨迹法深入研究虚拟阻抗对系统稳定性的影响。其次,提出利用交流电压变化率及电压差值等电气量构建虚拟电抗自适应调整项的改进VSG控制算法,在保证系统等效阻抗呈感性的同时,可提高送端交流系统的等效短路比,达到改善系统整体性能的效果。最后,通过PSCAD/EMTDC电磁暂态仿真验证所提控制策略的有效性。