To examine the seismic performance of a newly fabricated weakened joint at the beam end position,four groups of energy-consuming steel plates with different weakening depths and thicknesses were subjected to horizonta...To examine the seismic performance of a newly fabricated weakened joint at the beam end position,four groups of energy-consuming steel plates with different weakening depths and thicknesses were subjected to horizontal cyclic reciprocating loading tests on beam ends.The tests were designed to evaluate the beams'hysteresis curve,skeleton curve,bearing capacity degradation curve,stiffness degradation curve,and ductility and the nodes'energy dissipation capacity.The test results show that a newly fabricated joint will not undergo brittle damage when the beam-column joint is welded at a displacement of 105 mm.Thus,the hysteresis curve will show an inverse S shape,and an obvious slip phenomenon will occur,which is mainly due to splicing.The diameter of the bolt connecting the slab to the beam flange is slightly smaller than the aperture.Due to the existence of slippage,the skeleton curve has no evident yield point.The joint ductility coefficient is less than 3.0,and the initial rotational stiffness of the joint is also small.The buckling of the splicing panel causes a rapid decrease in the joint bearing capacity.The main approaches,appropriately reducing the weakening depth and increasing the thickness of the splicing plate,can delay the occurrence of buckling and improve the ductility of the joint.展开更多
基金The National Natural Science Foundation of China(No.51968043,51978320).
文摘To examine the seismic performance of a newly fabricated weakened joint at the beam end position,four groups of energy-consuming steel plates with different weakening depths and thicknesses were subjected to horizontal cyclic reciprocating loading tests on beam ends.The tests were designed to evaluate the beams'hysteresis curve,skeleton curve,bearing capacity degradation curve,stiffness degradation curve,and ductility and the nodes'energy dissipation capacity.The test results show that a newly fabricated joint will not undergo brittle damage when the beam-column joint is welded at a displacement of 105 mm.Thus,the hysteresis curve will show an inverse S shape,and an obvious slip phenomenon will occur,which is mainly due to splicing.The diameter of the bolt connecting the slab to the beam flange is slightly smaller than the aperture.Due to the existence of slippage,the skeleton curve has no evident yield point.The joint ductility coefficient is less than 3.0,and the initial rotational stiffness of the joint is also small.The buckling of the splicing panel causes a rapid decrease in the joint bearing capacity.The main approaches,appropriately reducing the weakening depth and increasing the thickness of the splicing plate,can delay the occurrence of buckling and improve the ductility of the joint.