A nonsimilarity analysis is performed to investigate the laminar, free convection boundary layer flow over a permeable isothermal truncated cone in the presence of a transverse magnetic field effect. A suitable set of...A nonsimilarity analysis is performed to investigate the laminar, free convection boundary layer flow over a permeable isothermal truncated cone in the presence of a transverse magnetic field effect. A suitable set of dimensionless variables is used and non-similar equations governing the problem are obtained. Fourth order Runge-Kutta with shooting technique is employed for the numerical solution of the obtained equations. Different water-based nanofluids containing Cu, Ag, CuO, Al2O3, and TiO2 are taken into consideration. The effects of pertinent parameters such as the solid volume fraction of nanoparticles, and magnetic field parameter have been investigated. Furthermore, different models of nanofluid based on different formulas for thermal conductivity and dynamic viscosity on the flow and heat transfer characteristics are discussed. Various comparisons with previously published work for the case of a vertical plate are performed and the results are found to be in excellent agreement.展开更多
In helical cone-beam computed tomography(CT), Feldkamp-Davis-Kress(FDK) based image reconstruction algorithms are by far the most popular. However, artifacts are commonly met in the presence of lateral projection trun...In helical cone-beam computed tomography(CT), Feldkamp-Davis-Kress(FDK) based image reconstruction algorithms are by far the most popular. However, artifacts are commonly met in the presence of lateral projection truncation. The reason is that the ramp filter is global. To restrain the truncation artifacts, an approximate reconstruction formula is proposed based on the Derivative-Hilbert-Backprojection(DHB) framework. In the method, the first order derivative filter is followed by the Hilbert transform. Since the filtered projection values are almost zero by the first order derivative filter, the following Hilbert transform has little influence on the projection values, even though the projections are laterally truncated. The proposed method has two main advantages. First, it has comparable computational efficiency and image quality as well as the conventional helical FDK algorithm for non-truncated projections. The second advantage is that images can be reconstructed with acceptable quality and much lower computational cost in comparison to the Laplace operator based algorithm in cases with truncated projections. To point out the advantages of our method, simulations on the computer and real data experiments on our laboratory industrial cone-beam CT are conducted. The simulated and experimental results demonstrate that the method is feasible for image reconstruction in the case of projection truncation.展开更多
In this work, we demonstrate that the theory of cone-beam tomography image reconstruction on chords can be modified for use with local tomography problems. Our analysis reveals that discontinuities in the profiles of ...In this work, we demonstrate that the theory of cone-beam tomography image reconstruction on chords can be modified for use with local tomography problems. Our analysis reveals that discontinuities in the profiles of the object function along chords can be reconstructed readily. By consideration of all possible chords, an image that de-scribes the location of boundaries within an object can be reconstructed. A preliminary numerical study is conducted to validate and demonstrate the reconstruction method.展开更多
文摘A nonsimilarity analysis is performed to investigate the laminar, free convection boundary layer flow over a permeable isothermal truncated cone in the presence of a transverse magnetic field effect. A suitable set of dimensionless variables is used and non-similar equations governing the problem are obtained. Fourth order Runge-Kutta with shooting technique is employed for the numerical solution of the obtained equations. Different water-based nanofluids containing Cu, Ag, CuO, Al2O3, and TiO2 are taken into consideration. The effects of pertinent parameters such as the solid volume fraction of nanoparticles, and magnetic field parameter have been investigated. Furthermore, different models of nanofluid based on different formulas for thermal conductivity and dynamic viscosity on the flow and heat transfer characteristics are discussed. Various comparisons with previously published work for the case of a vertical plate are performed and the results are found to be in excellent agreement.
基金Supported by the National High Technology Research and Development Program of China(No.2012AA011603)National Nature Science Foundation of China(No.61372172)
文摘In helical cone-beam computed tomography(CT), Feldkamp-Davis-Kress(FDK) based image reconstruction algorithms are by far the most popular. However, artifacts are commonly met in the presence of lateral projection truncation. The reason is that the ramp filter is global. To restrain the truncation artifacts, an approximate reconstruction formula is proposed based on the Derivative-Hilbert-Backprojection(DHB) framework. In the method, the first order derivative filter is followed by the Hilbert transform. Since the filtered projection values are almost zero by the first order derivative filter, the following Hilbert transform has little influence on the projection values, even though the projections are laterally truncated. The proposed method has two main advantages. First, it has comparable computational efficiency and image quality as well as the conventional helical FDK algorithm for non-truncated projections. The second advantage is that images can be reconstructed with acceptable quality and much lower computational cost in comparison to the Laplace operator based algorithm in cases with truncated projections. To point out the advantages of our method, simulations on the computer and real data experiments on our laboratory industrial cone-beam CT are conducted. The simulated and experimental results demonstrate that the method is feasible for image reconstruction in the case of projection truncation.
文摘In this work, we demonstrate that the theory of cone-beam tomography image reconstruction on chords can be modified for use with local tomography problems. Our analysis reveals that discontinuities in the profiles of the object function along chords can be reconstructed readily. By consideration of all possible chords, an image that de-scribes the location of boundaries within an object can be reconstructed. A preliminary numerical study is conducted to validate and demonstrate the reconstruction method.