Traditional gear weight optimization methods consider gear tooth number, module, face width or other dimension parameters of gear as design variables. However, due to the complicated form and geometric features peculi...Traditional gear weight optimization methods consider gear tooth number, module, face width or other dimension parameters of gear as design variables. However, due to the complicated form and geometric features peculiar to the gear, there will be large amounts of design parameters in gear design, and the influences of gear parameters changing on gear trains, transmission system and the whole equipment have to be taken into account, which increases the complexity of optimization problem. This paper puts forward to apply functionally graded materials(FGMs) to gears and then conduct the optimization. According to the force situation of gears, the material distribution form of FGM gears is determined. Then based on the performance parameters analysis of FGMs and the practical working demands for gears, a multi-objective optimization model is formed. Finally by using the goal driven optimization(GDO) method, the optimal material distribution is achieved, which makes gear weight and the maximum deformation be minimum and the maximum bending stress do not exceed the allowable stress. As an example, the applying of FGM to automotive transmission gear is conducted to illustrate the optimization design process and the result shows that under the condition of keeping the normal working performance of gear, the method achieves in greatly reducing the gear weight. This research proposes a FGM gears design method that is able to largely reduce the weight of gears by optimizing the microscopic material parameters instead of changing the macroscopic dimension parameters of gears, which reduces the complexity of gear weight optimization problem.展开更多
AIM To compare intravoxel incoherent motion(IVIM)-derived parameters with conventional diffusion-weighted imaging(DWI) parameters in predicting the histological grade of hepatocellular carcinoma(h CC) and to evaluate ...AIM To compare intravoxel incoherent motion(IVIM)-derived parameters with conventional diffusion-weighted imaging(DWI) parameters in predicting the histological grade of hepatocellular carcinoma(h CC) and to evaluate the correlation between the parameters and the histological grades.METHODS A retrospective study was performed. Sixty-two patients with surgically confirmed h CCs underwent diffusion-weighted magnetic resonance imaging with twelve b values(10-1200 s/mm^2). The apparent diffusion coefficient(ADC), pure diffusion coefficient(D), pseudo-diffusion coefficient(D*), and perfusion fraction(f) were calculated by two radiologists. The IVIM and conventional DWI parameters were compared among the different grades by using analysis of variance(ANOVA) and the Kruskal-Wallis test. Receiver operating characteristic(ROC) analysis was performed to evaluate the diagnostic efficiency of distinguishing between low-grade(grade 1, G1) and high-grade(grades 2 and 3, G2 and G3) hC C. The correlation between the parameters and the histological grades was assessed by using the Spearman correlation test. Bland-Altman analysis was used to evaluate the reproducibility of the two radiologists' measurements.RESULTS The differences in the ADC and D values among the groups with G1, G2, and G3 histological grades of HCCs were statistically significant(P < 0.001). The D* and f values had no significant differences among the different histological grades of h CC(P > 0.05). The ROC analyses demonstrated that the D and ADC values had better diagnostic performance in differentiating the low-grade h CC from the high-grade h CC, with areas under the curve(AUCs) of 0.909 and 0.843, respectively, measured by radiologist 1 and of 0.911 and 0.852, respectively, measured by radiologist 2. The following significant correlations were obtained between the ADC, D, and D~* values and the histological grades: r =-0.619(P < 0.001), r =-0.628(P < 0.001), and r =-0.299(P = 0.018), respectively, as measured by radiologist 1; r =-0.622(P < 0.001), r =-0.633(P < 0.001), and r =-0.303(P = 0.017), respectively, as measured by radiologist 2. The intra-class correlation coefficient(ICC) values between the two observers were 0.996 for ADC, 0.997 for D, 0.996 for D*, and 0.992 for f values, which indicated excellent interobserver agreement in the measurements between the two observers.CONCLUSION The IVIM-derived D and ADC values show better diagnostic performance in differentiating high-grade hC C from low-grade hC C, and there is a moderate to good correlation between the ADC and D values and the histological grades.展开更多
基金Supported by National Hi-tech Research and Development Program of China(863 Program,Grant No.2015AA042505)
文摘Traditional gear weight optimization methods consider gear tooth number, module, face width or other dimension parameters of gear as design variables. However, due to the complicated form and geometric features peculiar to the gear, there will be large amounts of design parameters in gear design, and the influences of gear parameters changing on gear trains, transmission system and the whole equipment have to be taken into account, which increases the complexity of optimization problem. This paper puts forward to apply functionally graded materials(FGMs) to gears and then conduct the optimization. According to the force situation of gears, the material distribution form of FGM gears is determined. Then based on the performance parameters analysis of FGMs and the practical working demands for gears, a multi-objective optimization model is formed. Finally by using the goal driven optimization(GDO) method, the optimal material distribution is achieved, which makes gear weight and the maximum deformation be minimum and the maximum bending stress do not exceed the allowable stress. As an example, the applying of FGM to automotive transmission gear is conducted to illustrate the optimization design process and the result shows that under the condition of keeping the normal working performance of gear, the method achieves in greatly reducing the gear weight. This research proposes a FGM gears design method that is able to largely reduce the weight of gears by optimizing the microscopic material parameters instead of changing the macroscopic dimension parameters of gears, which reduces the complexity of gear weight optimization problem.
文摘AIM To compare intravoxel incoherent motion(IVIM)-derived parameters with conventional diffusion-weighted imaging(DWI) parameters in predicting the histological grade of hepatocellular carcinoma(h CC) and to evaluate the correlation between the parameters and the histological grades.METHODS A retrospective study was performed. Sixty-two patients with surgically confirmed h CCs underwent diffusion-weighted magnetic resonance imaging with twelve b values(10-1200 s/mm^2). The apparent diffusion coefficient(ADC), pure diffusion coefficient(D), pseudo-diffusion coefficient(D*), and perfusion fraction(f) were calculated by two radiologists. The IVIM and conventional DWI parameters were compared among the different grades by using analysis of variance(ANOVA) and the Kruskal-Wallis test. Receiver operating characteristic(ROC) analysis was performed to evaluate the diagnostic efficiency of distinguishing between low-grade(grade 1, G1) and high-grade(grades 2 and 3, G2 and G3) hC C. The correlation between the parameters and the histological grades was assessed by using the Spearman correlation test. Bland-Altman analysis was used to evaluate the reproducibility of the two radiologists' measurements.RESULTS The differences in the ADC and D values among the groups with G1, G2, and G3 histological grades of HCCs were statistically significant(P < 0.001). The D* and f values had no significant differences among the different histological grades of h CC(P > 0.05). The ROC analyses demonstrated that the D and ADC values had better diagnostic performance in differentiating the low-grade h CC from the high-grade h CC, with areas under the curve(AUCs) of 0.909 and 0.843, respectively, measured by radiologist 1 and of 0.911 and 0.852, respectively, measured by radiologist 2. The following significant correlations were obtained between the ADC, D, and D~* values and the histological grades: r =-0.619(P < 0.001), r =-0.628(P < 0.001), and r =-0.299(P = 0.018), respectively, as measured by radiologist 1; r =-0.622(P < 0.001), r =-0.633(P < 0.001), and r =-0.303(P = 0.017), respectively, as measured by radiologist 2. The intra-class correlation coefficient(ICC) values between the two observers were 0.996 for ADC, 0.997 for D, 0.996 for D*, and 0.992 for f values, which indicated excellent interobserver agreement in the measurements between the two observers.CONCLUSION The IVIM-derived D and ADC values show better diagnostic performance in differentiating high-grade hC C from low-grade hC C, and there is a moderate to good correlation between the ADC and D values and the histological grades.