Smart metering has gained considerable attention as a research focus due to its reliability and energy-efficient nature compared to traditional electromechanical metering systems. Existing methods primarily focus on d...Smart metering has gained considerable attention as a research focus due to its reliability and energy-efficient nature compared to traditional electromechanical metering systems. Existing methods primarily focus on data management,rather than emphasizing efficiency. Accurate prediction of electricity consumption is crucial for enabling intelligent grid operations,including resource planning and demandsupply balancing. Smart metering solutions offer users the benefits of effectively interpreting their energy utilization and optimizing costs. Motivated by this,this paper presents an Intelligent Energy Utilization Analysis using Smart Metering Data(IUA-SMD)model to determine energy consumption patterns. The proposed IUA-SMD model comprises three major processes:data Pre-processing,feature extraction,and classification,with parameter optimization. We employ the extreme learning machine(ELM)based classification approach within the IUA-SMD model to derive optimal energy utilization labels. Additionally,we apply the shell game optimization(SGO)algorithm to enhance the classification efficiency of the ELM by optimizing its parameters. The effectiveness of the IUA-SMD model is evaluated using an extensive dataset of smart metering data,and the results are analyzed in terms of accuracy and mean square error(MSE). The proposed model demonstrates superior performance,achieving a maximum accuracy of65.917% and a minimum MSE of0.096. These results highlight the potential of the IUA-SMD model for enabling efficient energy utilization through intelligent analysis of smart metering data.展开更多
This paper represents a case study of traffic congestion within a section on Al Seeb Street highway due to the on-ramp merging of vehicles that causes a bottleneck in the mainline road. It studies the efficiency of in...This paper represents a case study of traffic congestion within a section on Al Seeb Street highway due to the on-ramp merging of vehicles that causes a bottleneck in the mainline road. It studies the efficiency of installing ramp metering within a ramp within the selected study zone. This is done by simulating the collected data using Vissim software by drawing three one-hour-long scenarios;the first scenario reflects the data collected for 30 minutes duration and is used as a base scenario to draw the other two scenarios, which are reflected as factored-up scenarios to create a situation observed in the early morning in the study zone at 6:00-7:00 in which slowing down of speeds exist, and breakdown is raised in working days. The two factoring-up scenarios were as follows: one without ramp metering and the other without ramp metering. Each scenario was calibrated and run five times with random seeds, and then the average was considered. The simulation examines the ability of RM to smooth traffic in mainline and reduce queuing on on-ramp roads within the selected study zone by comparing the performance of the network for the scenarios and comparing them in terms of the overall delays, number of stops and the average speeds for the vehicles within the mainline. The results showed a good performance reflected by the scenario with ramp metering with a reduction of the overall delay, a decrease in stops number and an increase of the average speed were achieved. For the base scenario, a visualization (video extracted from Vissim software) was extracted, showing no need to install RM with an associated table showing a number of stops equal to zero with an average speed of 102.74 km/h and a total delay of 6045 seconds. For the second scenario with no RM, a visualization was extracted showing a slowing down of speeds for vehicles within the mainline while vehicles merging from the on-ramp and need to be controlled with a table showing a number of stops equal to 16 and an average speed equal to 58 km/h and a total delay of 916,874 seconds. For the third scenario with RM, a visualization was extracted showing good control of the second scenario with a table showing the number of stops equal to 6, an average speed equal to 61 km/h and a total delay equal to 484,466 seconds. Ten literatures in regard to this study have been reviewed. The data collected are quantitative, which are collected using an indirect manual counting method and then the data is used to feed the software for simulation.展开更多
In recent years, semiconductor survey meters have been developed and are in increasing demand worldwide. This study determined if it is possible to use the X-ray system installed in each medical facility to calculate ...In recent years, semiconductor survey meters have been developed and are in increasing demand worldwide. This study determined if it is possible to use the X-ray system installed in each medical facility to calculate the time constant of a semiconductor survey meter and confirm the meter’s function. An additional filter was attached to the medical X-ray system to satisfy the standards of N-60 to N-120, more copper plates were added as needed, and the first and second half-value layers were calculated to enable comparisons of the facility’s X-ray system quality with the N-60 to N-120 quality values. Next, we used a medical X-ray system to measure the leakage dose and calculate the time constant of the survey meter. The functionality of the meter was then checked and compared with the energy characteristics of the meter. The experimental results showed that it was possible to use a medical X-ray system to reproduce the N-60 to N-120 radiation quality values and to calculate the time constant from the measured results, assuming actual leakage dosimetry for that radiation quality. We also found that the calibration factor was equivalent to that of the energy characteristics of the survey meter.展开更多
In order to more accurately detect the accuracy of word-wheel water meter digits, 2000 water meter pictures were produced, and an improved Faster-RCNN algorithm for detecting water meter digits was proposed. The impro...In order to more accurately detect the accuracy of word-wheel water meter digits, 2000 water meter pictures were produced, and an improved Faster-RCNN algorithm for detecting water meter digits was proposed. The improved Faster-RCNN algorithm uses ResNet50 combined with FPN (Feature Pyramid Network) structure instead of the original ResNet50 as the feature extraction network, which can enhance the accuracy of the model for small-sized digit recognition;the use of ROI Align instead of ROI Pooling can eliminate the error caused by the quantization process of the ROI Pooling twice, so that the candidate region is more accurately mapped to the feature map, and the accuracy of the model is further enhanced. The experiment proves that the improved Faster-RCNN algorithm can reach 91.8% recognition accuracy on the test set of homemade dataset, which meets the accuracy requirements of automatic meter reading technology for water meter digital recognition, which is of great significance for solving the problem of automatic meter reading of mechanical water meters and promoting the intelligent development of water meters.展开更多
An iterative learning control scheme is developed to the traffic densitycontrol in a macroscopic level freeway environment. With rigorous analysis, the proposed intelligentcontrol scheme guarantees the asymptotic conv...An iterative learning control scheme is developed to the traffic densitycontrol in a macroscopic level freeway environment. With rigorous analysis, the proposed intelligentcontrol scheme guarantees the asymptotic convergence of the traffic density to the desired one. Thecontrol scheme is applied to a freeway model, and simulation results confirm the efficacy of theproposed approach.展开更多
In this paper,the gas and seed flow characters in the air-blowing seed metering device are investigated by using the coupled computational fluid dynamics and discrete element method(CFD-DEM)in three dimensions(3D).The...In this paper,the gas and seed flow characters in the air-blowing seed metering device are investigated by using the coupled computational fluid dynamics and discrete element method(CFD-DEM)in three dimensions(3D).The method of establishing boundary model based on the computer-aided design(CAD)drawing,has been used to build the boundary model of seed metering device.The 3D laser scanning technique and multi-element method are adopted to establish the particle model.Through a combined numerical and experimental effort,using 3D CFD-DEM software,which is based on the in-house codes,the mechanisms governing the gas and solid dynamic behaviors in the seed metering device have been studied.The gas velocity field and the effect of different rotational speeds and air pressures on the seeding performance and particle velocity have been studied,similar agreements between numerical and experimental results are gained.This reveals that the 3D CFD-DEM model established is able to predict the performance of the air-blowing seed metering device.It can be used to design and optimize the air-blowing seed metering device and other similar agriculture devices.展开更多
This job focuses on the stroke regulation of a class of high-precision metering pumps.A parametertuning method of robust non-fragile PID(proportional-integral-derivative)controllers is proposed with the assumption t...This job focuses on the stroke regulation of a class of high-precision metering pumps.A parametertuning method of robust non-fragile PID(proportional-integral-derivative)controllers is proposed with the assumption that a PID controller has additive gain perturbations.An H-infinite robust PID controller can be obtained by solving a linear matrix inequality.This approach can guarantee that the closed-loop control systems is asymptotically stable and the H-infinite norm of the transfer function from the disturbance to the output of a controlled system is less than a given constant to attenuate disturbances.The simulation case shows that the control performance of the proposed strategy is significantly better than the traditional PID approach in the situation with perturbations of controller parameters.展开更多
Digital networked communications are the key to all Internet-of-things applications, but especially to smart metering systems and the smart grid. In order to ensure a safe operation of systems and the privacy of users...Digital networked communications are the key to all Internet-of-things applications, but especially to smart metering systems and the smart grid. In order to ensure a safe operation of systems and the privacy of users, the transport layer security (TLS) protocol, a mature and well standardized solution for secure communications, may be used. We implemented the TLS protocol in its latest version in a way suitable for embedded and resource-constrained systems. This paper outlines the challenges and opportunities of deploying TLS in smart metering and smart grid applications and presents performance results of our TLS implementation. Our analysis shows that given an appropriate implementation and configuration, deploying TLS in constrained smart metering systems is possible with acceptable overhead.展开更多
Prepaid energy meters have been widely adopted by utilities in different countries across the world as an innovative solution to the problem of affordability and consumption management. However, the present smart card...Prepaid energy meters have been widely adopted by utilities in different countries across the world as an innovative solution to the problem of affordability and consumption management. However, the present smart card based systems have some inherent problems like added cost, low availability and lack of security. In the future Smart Grid paradigm, use of smart meters can completely overhaul these prepaid systems by introducing centralized accounting, monitoring and credit-control functions using state-of-the-art telecommunication technologies like WiMAX. In this paper we pro-pose a prepaid smart metering scheme for Smart Grid application based on centralized authentication and charging using the WiMAX prepaid accounting model. We then discuss its specific application to Demand Response and Roam-ing of Electrical Vehicles.展开更多
The mechanism of grain fracturing in a zirconia metering nozzle used in the continuous casting process was studied. The phase composition, microstructure, and chemical composition of the residual samples were studied ...The mechanism of grain fracturing in a zirconia metering nozzle used in the continuous casting process was studied. The phase composition, microstructure, and chemical composition of the residual samples were studied using an X-ray fluorescence analyzer, scanning electron microscope, and electron probe. Results revealed that the composition, structure, and mineral phase of the original layer, transition layer, and affected layer of the metering nozzle differed because of stabilizer precipitation and steel slag permeation. The stabilizer MgO formed low-melting phases with steel slag and impure SiO2 on the boundaries(pores) of zirconia grains; consequently, grain fracturing occurred and accelerated damage to the metering nozzle was observed.展开更多
Based on the mechanical and physical properties study of forage grass seeds, multi-line with one-device type metering device was designed. It was composed of adjustable screw, stirrer, metering device housing and cent...Based on the mechanical and physical properties study of forage grass seeds, multi-line with one-device type metering device was designed. It was composed of adjustable screw, stirrer, metering device housing and central metering sheave and so on. The sowing rate can be set by turning the screw to change the working length of the central metering sheave relative to the metering device housing. The stirrer inside of the sheave housing is used to prevent seeds overhead. And metering of different sizes of seed is adjusted by changing the position of internal components of the slot wheel mechanism. Innovative design on the structure of the central metering sheave was finished. According to the structure parameters and physical characteristic parameters, different seed sowing rate of per hectares was calculated. And then the working length scale of the central metering groove wheel was made. And there is a one-to-one correspondence between scale values and sowing quantity per hectare of different kinds of seed.展开更多
In hydraulic area,independent metering control(IMC)technology is an effective approach to improve system efficiency and control flexibility.In addition,digital hydraulic technology(DHT)has been verified as a reasonabl...In hydraulic area,independent metering control(IMC)technology is an effective approach to improve system efficiency and control flexibility.In addition,digital hydraulic technology(DHT)has been verified as a reasonable method to optimize system dynamic performance.Integrating these two technologies into one component can combine their advantages together.However,few works focused on it.In this paper,a twin spools valve with switching technologycontrolled pilot stage(TSVSP)is presented,which applied DHT into its pilot stage while appending IMC into its main stage.Based on this prototype valve,a series of numerical and experiment analysis of its IMC performance with both simulated load and excavator boom cylinder are carried out.Results showed fast and robust performance of pressure and flow compound control with acceptable fluctuation phenomenon caused by switching technology.Rising time of flow response in excavator cylinder can be controlled within 200 ms,meanwhile,the recovery time of rod chamber pressure under suddenly changed condition is optimized within 250 ms.IMC system based on TSVSP can improve both dynamic performance and robust characteristics of the target actuator so it is practical in valve-cylinder system and can be applied in mobile machineries.展开更多
As the intermittency and uncertainty of photovoltaic(PV)power generation poses considerable challenges to the power system operation,accurate PV generation estimates are critical for the distribution operation,mainten...As the intermittency and uncertainty of photovoltaic(PV)power generation poses considerable challenges to the power system operation,accurate PV generation estimates are critical for the distribution operation,maintenance,and demand response program implementation because of the increasing usage of distributed PVs.Currently,most residential PVs are installed behind the meter,with only the net load available to the utilities.Therefore,a method for disaggregating the residential PV generation from the net load data is needed to enhance the grid-edge observability.In this study,an unsupervised PV capacity estimation method based on net metering data is proposed,for estimating the PV capacity in the customer’s premise based on the distribution characteristics of nocturnal and diurnal net load extremes.Then,the PV generation disaggregation method is presented.Based on the analysis of the correlation between the nocturnal and diurnal actual loads and the correlation between the PV capacity and their actual PV generation,the PV generation of customers is estimated by applying linear fitting of multiple typical solar exemplars and then disaggregating them into hourly-resolution power profiles.Finally,the anomalies of disaggregated PV power are calibrated and corrected using the estimated capacity.Experiment results on a real-world hourly dataset involving 260 customers show that the proposed PV capacity estimation method achieves good accuracy because of the advantages of robustness and low complexity.Compared with the state-of-the-art PV disaggregation algorithm,the proposed method exhibits a reduction of over 15%for the mean absolute percentage error and over 20%for the root mean square error.展开更多
Although widely used, both the Markowitz model and VAR (Value at Risk) model have some limitations in evaluating the risk and return of stock investment. By the analysis of the conceptions of risk and return, together...Although widely used, both the Markowitz model and VAR (Value at Risk) model have some limitations in evaluating the risk and return of stock investment. By the analysis of the conceptions of risk and return, together with the three hypotheses of technological analysis, a novelty model of metering and evaluating the risk and return of stock investment is established. The major indicator of this model , risk-return ratio K, combines the characteristic indicators of risk and return. Regardless of the form of the risk-return probability density functions, this indicator K can always reflect the risk-return performances of the invested stocks clearly and accurately. How to use the model to make optimum investment and how to make portfolio combined with clustering analysis is also explained.展开更多
To implement the access and backhaul networks for Smart Metering (SM) systems various technologies are combined with the existing communications infrastructure. This paper deals with data transmission in SM systems, f...To implement the access and backhaul networks for Smart Metering (SM) systems various technologies are combined with the existing communications infrastructure. This paper deals with data transmission in SM systems, focusing on how the existing cellular networks infrastructure is employed to implement SM access communication networks. The analysis aims at analyzing the role of the cellular communications infrastructure taking into account the spatial distribution and installation points of the smart meters, the urban and topological characteristics of the SM deployment areas and the common practice so far followed by the utilities. It is demonstrated that cellular communications, either exclusively or combined with power line communications, enable immediate and scalable deployment of SM access communication networks at low installation cost, thus constituting the basic option for the implementation of smart metering.展开更多
The effects of temperature-gradient-induced damage of zirconia metering nozzles were investigated through analysis of the phase composition and microstructure of nozzle samples. The analysis was carried out using X-ra...The effects of temperature-gradient-induced damage of zirconia metering nozzles were investigated through analysis of the phase composition and microstructure of nozzle samples. The analysis was carried out using X-ray diffraction and scanning electron microscopy after the samples were subjected to a heat treatment based on the temperatures of the affected, transition, and original layers of zirconia metering nozzles during the continuous casting of steel. The results showed that, after heat treatment at 1540, 1410, or 1300A degrees C for a dwell time of 5 h, the monoclinic zirconia phase was gradually stabilized with increasing heat-treatment temperature. Moreover, a transformation to the cubic zirconia phase occurred, accompanied by grain growth, which illustrates that the temperature gradient in zirconia metering nozzles affects the mineral composition and microstructure of the nozzles and accelerates damage, thereby deteriorating the quality and service life of the nozzles.展开更多
Vacuum precision seed metering is the key part of vacuum seed planter. Planting performance of planter is affected by vacuum and air flow which are important parameters for choosing fan. Effects of qualification perce...Vacuum precision seed metering is the key part of vacuum seed planter. Planting performance of planter is affected by vacuum and air flow which are important parameters for choosing fan. Effects of qualification percent and miss percent on air chamber vacuum 3, 4, 5 and 6 kPa were studied at different operating speeds. The results showed that operating performance of the seed metering was excellent when air chamber vacuum was 5 and 6 kPa, which air flow was 7.4-8.0 m3·s-1 and 8.0-8.8 m3·s-1 , respectively.展开更多
Metering technology is one of the core technologies of the smart power grid. The overall metering solution and related products have a wide market space in the whole process of power production, which bring new opport...Metering technology is one of the core technologies of the smart power grid. The overall metering solution and related products have a wide market space in the whole process of power production, which bring new opportunities for power distribution development from automation to intelligentialize, and provide technical supports for the power metering system platform. Because of the importance of metering products and their market demand, this paper focuses on the design of a simple power metering chip with low-cost, low-precision and non-invasive, so as to lay the foundation for the development and practical technology accumulation of power metering products. The design achieves low cost by reducing the acquisition accuracy, simplifying the collection and sampling methods. This paper studies the chip accuracy, sampling methods, collection methods, and the inference of the chip characteristics requirements.展开更多
Aiming at the shortcomings of the separate meter in and separate meter out?hydraulic system, a new type of independent metering control system is proposed by referring to the principle of load-sensing system. The valv...Aiming at the shortcomings of the separate meter in and separate meter out?hydraulic system, a new type of independent metering control system is proposed by referring to the principle of load-sensing system. The valve group unit in the system is designed, and the AMESim/Matlab cosimulation model of the component and system is established. The actuator speed control, energy consumption and anti-flow saturation characteristics of the system are discussed. The simulation result shows that the system proposed in this article can achieve?better performances.展开更多
In this paper, a security protocol for the advanced metering infrastructure (AMI) in smart grid is proposed. Through the AMI, customers and the service provider achieve two-way communication. Real-time monitoring an...In this paper, a security protocol for the advanced metering infrastructure (AMI) in smart grid is proposed. Through the AMI, customers and the service provider achieve two-way communication. Real-time monitoring and demand response can be applied because of the information exchanged. Since the information contains much privacy of the customer, and the control messages need to be authenticated, security needs to be ensured for the communication in the AM1. Due to the complicated network structure of the AMI, the asymmetric communications, and various security requirements, existing security protocols for other networks can hardly be applied into the AMI directly. Therefore, a security protocol specifically for the AMI to meet the security requirements is proposed. Our proposed security protocol includes initial authentication, secure uplink data aggregation, secure downlink data transmission, and domain secrets update. Compared with existing researches in related areas, our proposed security protocol takes the asymmetric communications of the AMI and various security requirements in smart grid into consideration.展开更多
文摘Smart metering has gained considerable attention as a research focus due to its reliability and energy-efficient nature compared to traditional electromechanical metering systems. Existing methods primarily focus on data management,rather than emphasizing efficiency. Accurate prediction of electricity consumption is crucial for enabling intelligent grid operations,including resource planning and demandsupply balancing. Smart metering solutions offer users the benefits of effectively interpreting their energy utilization and optimizing costs. Motivated by this,this paper presents an Intelligent Energy Utilization Analysis using Smart Metering Data(IUA-SMD)model to determine energy consumption patterns. The proposed IUA-SMD model comprises three major processes:data Pre-processing,feature extraction,and classification,with parameter optimization. We employ the extreme learning machine(ELM)based classification approach within the IUA-SMD model to derive optimal energy utilization labels. Additionally,we apply the shell game optimization(SGO)algorithm to enhance the classification efficiency of the ELM by optimizing its parameters. The effectiveness of the IUA-SMD model is evaluated using an extensive dataset of smart metering data,and the results are analyzed in terms of accuracy and mean square error(MSE). The proposed model demonstrates superior performance,achieving a maximum accuracy of65.917% and a minimum MSE of0.096. These results highlight the potential of the IUA-SMD model for enabling efficient energy utilization through intelligent analysis of smart metering data.
文摘This paper represents a case study of traffic congestion within a section on Al Seeb Street highway due to the on-ramp merging of vehicles that causes a bottleneck in the mainline road. It studies the efficiency of installing ramp metering within a ramp within the selected study zone. This is done by simulating the collected data using Vissim software by drawing three one-hour-long scenarios;the first scenario reflects the data collected for 30 minutes duration and is used as a base scenario to draw the other two scenarios, which are reflected as factored-up scenarios to create a situation observed in the early morning in the study zone at 6:00-7:00 in which slowing down of speeds exist, and breakdown is raised in working days. The two factoring-up scenarios were as follows: one without ramp metering and the other without ramp metering. Each scenario was calibrated and run five times with random seeds, and then the average was considered. The simulation examines the ability of RM to smooth traffic in mainline and reduce queuing on on-ramp roads within the selected study zone by comparing the performance of the network for the scenarios and comparing them in terms of the overall delays, number of stops and the average speeds for the vehicles within the mainline. The results showed a good performance reflected by the scenario with ramp metering with a reduction of the overall delay, a decrease in stops number and an increase of the average speed were achieved. For the base scenario, a visualization (video extracted from Vissim software) was extracted, showing no need to install RM with an associated table showing a number of stops equal to zero with an average speed of 102.74 km/h and a total delay of 6045 seconds. For the second scenario with no RM, a visualization was extracted showing a slowing down of speeds for vehicles within the mainline while vehicles merging from the on-ramp and need to be controlled with a table showing a number of stops equal to 16 and an average speed equal to 58 km/h and a total delay of 916,874 seconds. For the third scenario with RM, a visualization was extracted showing good control of the second scenario with a table showing the number of stops equal to 6, an average speed equal to 61 km/h and a total delay equal to 484,466 seconds. Ten literatures in regard to this study have been reviewed. The data collected are quantitative, which are collected using an indirect manual counting method and then the data is used to feed the software for simulation.
文摘In recent years, semiconductor survey meters have been developed and are in increasing demand worldwide. This study determined if it is possible to use the X-ray system installed in each medical facility to calculate the time constant of a semiconductor survey meter and confirm the meter’s function. An additional filter was attached to the medical X-ray system to satisfy the standards of N-60 to N-120, more copper plates were added as needed, and the first and second half-value layers were calculated to enable comparisons of the facility’s X-ray system quality with the N-60 to N-120 quality values. Next, we used a medical X-ray system to measure the leakage dose and calculate the time constant of the survey meter. The functionality of the meter was then checked and compared with the energy characteristics of the meter. The experimental results showed that it was possible to use a medical X-ray system to reproduce the N-60 to N-120 radiation quality values and to calculate the time constant from the measured results, assuming actual leakage dosimetry for that radiation quality. We also found that the calibration factor was equivalent to that of the energy characteristics of the survey meter.
文摘In order to more accurately detect the accuracy of word-wheel water meter digits, 2000 water meter pictures were produced, and an improved Faster-RCNN algorithm for detecting water meter digits was proposed. The improved Faster-RCNN algorithm uses ResNet50 combined with FPN (Feature Pyramid Network) structure instead of the original ResNet50 as the feature extraction network, which can enhance the accuracy of the model for small-sized digit recognition;the use of ROI Align instead of ROI Pooling can eliminate the error caused by the quantization process of the ROI Pooling twice, so that the candidate region is more accurately mapped to the feature map, and the accuracy of the model is further enhanced. The experiment proves that the improved Faster-RCNN algorithm can reach 91.8% recognition accuracy on the test set of homemade dataset, which meets the accuracy requirements of automatic meter reading technology for water meter digital recognition, which is of great significance for solving the problem of automatic meter reading of mechanical water meters and promoting the intelligent development of water meters.
文摘An iterative learning control scheme is developed to the traffic densitycontrol in a macroscopic level freeway environment. With rigorous analysis, the proposed intelligentcontrol scheme guarantees the asymptotic convergence of the traffic density to the desired one. Thecontrol scheme is applied to a freeway model, and simulation results confirm the efficacy of theproposed approach.
基金The authors would like to express appreciation for the support of Australia Research Council(IH140100035)Nature Science Foundation of China(51675218)+1 种基金Doctor Starting Foundation of Jiangxi University of Science and Technology(JXXJBS17078)Science and Technology Project of the Education Department of Jiangxi Province(GJJ180426).
文摘In this paper,the gas and seed flow characters in the air-blowing seed metering device are investigated by using the coupled computational fluid dynamics and discrete element method(CFD-DEM)in three dimensions(3D).The method of establishing boundary model based on the computer-aided design(CAD)drawing,has been used to build the boundary model of seed metering device.The 3D laser scanning technique and multi-element method are adopted to establish the particle model.Through a combined numerical and experimental effort,using 3D CFD-DEM software,which is based on the in-house codes,the mechanisms governing the gas and solid dynamic behaviors in the seed metering device have been studied.The gas velocity field and the effect of different rotational speeds and air pressures on the seeding performance and particle velocity have been studied,similar agreements between numerical and experimental results are gained.This reveals that the 3D CFD-DEM model established is able to predict the performance of the air-blowing seed metering device.It can be used to design and optimize the air-blowing seed metering device and other similar agriculture devices.
基金Supported by the National Natural Science Foundation of China(60604015) the Key Research Program of Education Department of Zhejiang Province(Z200803521)
文摘This job focuses on the stroke regulation of a class of high-precision metering pumps.A parametertuning method of robust non-fragile PID(proportional-integral-derivative)controllers is proposed with the assumption that a PID controller has additive gain perturbations.An H-infinite robust PID controller can be obtained by solving a linear matrix inequality.This approach can guarantee that the closed-loop control systems is asymptotically stable and the H-infinite norm of the transfer function from the disturbance to the output of a controlled system is less than a given constant to attenuate disturbances.The simulation case shows that the control performance of the proposed strategy is significantly better than the traditional PID approach in the situation with perturbations of controller parameters.
基金supported in part by the Federal Ministry of Economics and Energy as a cooperative ZIM-KF project under Grant No.KF2471305ED2the good cooperation with the project partner SSV Software Systems GmbH
文摘Digital networked communications are the key to all Internet-of-things applications, but especially to smart metering systems and the smart grid. In order to ensure a safe operation of systems and the privacy of users, the transport layer security (TLS) protocol, a mature and well standardized solution for secure communications, may be used. We implemented the TLS protocol in its latest version in a way suitable for embedded and resource-constrained systems. This paper outlines the challenges and opportunities of deploying TLS in smart metering and smart grid applications and presents performance results of our TLS implementation. Our analysis shows that given an appropriate implementation and configuration, deploying TLS in constrained smart metering systems is possible with acceptable overhead.
文摘Prepaid energy meters have been widely adopted by utilities in different countries across the world as an innovative solution to the problem of affordability and consumption management. However, the present smart card based systems have some inherent problems like added cost, low availability and lack of security. In the future Smart Grid paradigm, use of smart meters can completely overhaul these prepaid systems by introducing centralized accounting, monitoring and credit-control functions using state-of-the-art telecommunication technologies like WiMAX. In this paper we pro-pose a prepaid smart metering scheme for Smart Grid application based on centralized authentication and charging using the WiMAX prepaid accounting model. We then discuss its specific application to Demand Response and Roam-ing of Electrical Vehicles.
基金funded by the National Natural Science Foundation of China(51372193)the Natural Science Basic Research Plan in the Shaanxi Province of China(2014JM6224)
文摘The mechanism of grain fracturing in a zirconia metering nozzle used in the continuous casting process was studied. The phase composition, microstructure, and chemical composition of the residual samples were studied using an X-ray fluorescence analyzer, scanning electron microscope, and electron probe. Results revealed that the composition, structure, and mineral phase of the original layer, transition layer, and affected layer of the metering nozzle differed because of stabilizer precipitation and steel slag permeation. The stabilizer MgO formed low-melting phases with steel slag and impure SiO2 on the boundaries(pores) of zirconia grains; consequently, grain fracturing occurred and accelerated damage to the metering nozzle was observed.
文摘Based on the mechanical and physical properties study of forage grass seeds, multi-line with one-device type metering device was designed. It was composed of adjustable screw, stirrer, metering device housing and central metering sheave and so on. The sowing rate can be set by turning the screw to change the working length of the central metering sheave relative to the metering device housing. The stirrer inside of the sheave housing is used to prevent seeds overhead. And metering of different sizes of seed is adjusted by changing the position of internal components of the slot wheel mechanism. Innovative design on the structure of the central metering sheave was finished. According to the structure parameters and physical characteristic parameters, different seed sowing rate of per hectares was calculated. And then the working length scale of the central metering groove wheel was made. And there is a one-to-one correspondence between scale values and sowing quantity per hectare of different kinds of seed.
基金Supported by National Natural Science Foundation of China(Grant Nos.52005441,51890885)open Foundation of the State Key Laboratory of Fluid Power and Mechatronic Systems(Grant No.GZKF-201906)+1 种基金Zhejiang Province Natural Science Foundation of China(Grant No.LQ21E050017)China Postdoctoral Science Foundation(Grant Nos.2021M692777,2021T140594).
文摘In hydraulic area,independent metering control(IMC)technology is an effective approach to improve system efficiency and control flexibility.In addition,digital hydraulic technology(DHT)has been verified as a reasonable method to optimize system dynamic performance.Integrating these two technologies into one component can combine their advantages together.However,few works focused on it.In this paper,a twin spools valve with switching technologycontrolled pilot stage(TSVSP)is presented,which applied DHT into its pilot stage while appending IMC into its main stage.Based on this prototype valve,a series of numerical and experiment analysis of its IMC performance with both simulated load and excavator boom cylinder are carried out.Results showed fast and robust performance of pressure and flow compound control with acceptable fluctuation phenomenon caused by switching technology.Rising time of flow response in excavator cylinder can be controlled within 200 ms,meanwhile,the recovery time of rod chamber pressure under suddenly changed condition is optimized within 250 ms.IMC system based on TSVSP can improve both dynamic performance and robust characteristics of the target actuator so it is practical in valve-cylinder system and can be applied in mobile machineries.
基金supported by the Science and Technology Project of State Grid Corporation of China(No.5400-202112507A-0-5-ZN)the National Nature Science Foundation for Young Scholars of China(No.52107120).
文摘As the intermittency and uncertainty of photovoltaic(PV)power generation poses considerable challenges to the power system operation,accurate PV generation estimates are critical for the distribution operation,maintenance,and demand response program implementation because of the increasing usage of distributed PVs.Currently,most residential PVs are installed behind the meter,with only the net load available to the utilities.Therefore,a method for disaggregating the residential PV generation from the net load data is needed to enhance the grid-edge observability.In this study,an unsupervised PV capacity estimation method based on net metering data is proposed,for estimating the PV capacity in the customer’s premise based on the distribution characteristics of nocturnal and diurnal net load extremes.Then,the PV generation disaggregation method is presented.Based on the analysis of the correlation between the nocturnal and diurnal actual loads and the correlation between the PV capacity and their actual PV generation,the PV generation of customers is estimated by applying linear fitting of multiple typical solar exemplars and then disaggregating them into hourly-resolution power profiles.Finally,the anomalies of disaggregated PV power are calibrated and corrected using the estimated capacity.Experiment results on a real-world hourly dataset involving 260 customers show that the proposed PV capacity estimation method achieves good accuracy because of the advantages of robustness and low complexity.Compared with the state-of-the-art PV disaggregation algorithm,the proposed method exhibits a reduction of over 15%for the mean absolute percentage error and over 20%for the root mean square error.
文摘Although widely used, both the Markowitz model and VAR (Value at Risk) model have some limitations in evaluating the risk and return of stock investment. By the analysis of the conceptions of risk and return, together with the three hypotheses of technological analysis, a novelty model of metering and evaluating the risk and return of stock investment is established. The major indicator of this model , risk-return ratio K, combines the characteristic indicators of risk and return. Regardless of the form of the risk-return probability density functions, this indicator K can always reflect the risk-return performances of the invested stocks clearly and accurately. How to use the model to make optimum investment and how to make portfolio combined with clustering analysis is also explained.
文摘To implement the access and backhaul networks for Smart Metering (SM) systems various technologies are combined with the existing communications infrastructure. This paper deals with data transmission in SM systems, focusing on how the existing cellular networks infrastructure is employed to implement SM access communication networks. The analysis aims at analyzing the role of the cellular communications infrastructure taking into account the spatial distribution and installation points of the smart meters, the urban and topological characteristics of the SM deployment areas and the common practice so far followed by the utilities. It is demonstrated that cellular communications, either exclusively or combined with power line communications, enable immediate and scalable deployment of SM access communication networks at low installation cost, thus constituting the basic option for the implementation of smart metering.
基金financially supported by the National Natural Science Foundation of China (No. 51372193)
文摘The effects of temperature-gradient-induced damage of zirconia metering nozzles were investigated through analysis of the phase composition and microstructure of nozzle samples. The analysis was carried out using X-ray diffraction and scanning electron microscopy after the samples were subjected to a heat treatment based on the temperatures of the affected, transition, and original layers of zirconia metering nozzles during the continuous casting of steel. The results showed that, after heat treatment at 1540, 1410, or 1300A degrees C for a dwell time of 5 h, the monoclinic zirconia phase was gradually stabilized with increasing heat-treatment temperature. Moreover, a transformation to the cubic zirconia phase occurred, accompanied by grain growth, which illustrates that the temperature gradient in zirconia metering nozzles affects the mineral composition and microstructure of the nozzles and accelerates damage, thereby deteriorating the quality and service life of the nozzles.
基金Supported by the Youth Science Foundation of Heilongjiang(QC2010119,QC2010028)the Science and Technology Innovation Person with Ability Study Special Foundation Project of Harbin(2011RFQXN054)+1 种基金the Graduate Student Innovative Scientific Research Project of Heilongjiang(YJSCX2011-064JHL)Division of Soybean Machinery,CARS(nycytx-004)
文摘Vacuum precision seed metering is the key part of vacuum seed planter. Planting performance of planter is affected by vacuum and air flow which are important parameters for choosing fan. Effects of qualification percent and miss percent on air chamber vacuum 3, 4, 5 and 6 kPa were studied at different operating speeds. The results showed that operating performance of the seed metering was excellent when air chamber vacuum was 5 and 6 kPa, which air flow was 7.4-8.0 m3·s-1 and 8.0-8.8 m3·s-1 , respectively.
文摘Metering technology is one of the core technologies of the smart power grid. The overall metering solution and related products have a wide market space in the whole process of power production, which bring new opportunities for power distribution development from automation to intelligentialize, and provide technical supports for the power metering system platform. Because of the importance of metering products and their market demand, this paper focuses on the design of a simple power metering chip with low-cost, low-precision and non-invasive, so as to lay the foundation for the development and practical technology accumulation of power metering products. The design achieves low cost by reducing the acquisition accuracy, simplifying the collection and sampling methods. This paper studies the chip accuracy, sampling methods, collection methods, and the inference of the chip characteristics requirements.
文摘Aiming at the shortcomings of the separate meter in and separate meter out?hydraulic system, a new type of independent metering control system is proposed by referring to the principle of load-sensing system. The valve group unit in the system is designed, and the AMESim/Matlab cosimulation model of the component and system is established. The actuator speed control, energy consumption and anti-flow saturation characteristics of the system are discussed. The simulation result shows that the system proposed in this article can achieve?better performances.
基金supported by the National Science Fourdation under Grant No.CNS-1423408
文摘In this paper, a security protocol for the advanced metering infrastructure (AMI) in smart grid is proposed. Through the AMI, customers and the service provider achieve two-way communication. Real-time monitoring and demand response can be applied because of the information exchanged. Since the information contains much privacy of the customer, and the control messages need to be authenticated, security needs to be ensured for the communication in the AM1. Due to the complicated network structure of the AMI, the asymmetric communications, and various security requirements, existing security protocols for other networks can hardly be applied into the AMI directly. Therefore, a security protocol specifically for the AMI to meet the security requirements is proposed. Our proposed security protocol includes initial authentication, secure uplink data aggregation, secure downlink data transmission, and domain secrets update. Compared with existing researches in related areas, our proposed security protocol takes the asymmetric communications of the AMI and various security requirements in smart grid into consideration.