期刊文献+
共找到1,139篇文章
< 1 2 57 >
每页显示 20 50 100
Seismic performance evaluation of steel frame-steel plate shear walls system based on the capacity spectrum method 被引量:3
1
作者 Jian-hua SHAO Qiang GU Yong-kang SHEN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第3期322-329,共8页
This paper presents some methods that the standard acceleration design response spectra derived from the present China code for seismic design of buildings are transformed into the seismic demand spectra, and that the... This paper presents some methods that the standard acceleration design response spectra derived from the present China code for seismic design of buildings are transformed into the seismic demand spectra, and that the base shear force-roof displacement curve of structure is converted to the capacity spectrum of an equivalent single-degree-of-freedom (SDOF) system. The capacity spectrum method (CSM) is programmed by means of MATLABT.0 computer language. A dual lateral force resisting system of 10-story steel frame-steel plate shear walls (SPSW) is designed according to the corresponding China design codes. The base shear force-roof displacement curve of structure subjected to the monotonic increasing lateral inverse triangular load is obtained by applying the equivalent strip model to stimulate SPSW and by using the finite element analysis software SAP2000 to make Pushover analysis. The seismic performance of this dual system subjected to three different conditions, i.e. the 8-intensity frequently occurred earthquake, fortification earthquake and seldom occurred earthquake, is evaluated by CSM program. The excessive safety of steel frame-SPSW system designed according to the present China design codes is pointed out and a new design method is suggested. 展开更多
关键词 steel frame-steel plate shear walls (SPSW) system Capacity spectrum method (CSM) Seismic demand spectrum Base shear force-roof displacement Seismic performance evaluation
下载PDF
Analysis and seismic tests of composite shear walls with CFST columns and steel plate deep beams 被引量:1
2
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Zhang Jianwei Xu Fangfang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第4期609-624,共16页
A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipat... A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures. 展开更多
关键词 concrete filled steel tube (CFST) column steel plate (SP) deep beam composite shear wall seismic test calculation and analysis
下载PDF
Lateral load-carrying capacity analyses of composite shear walls with double steel plates and filled concrete with binding bars 被引量:1
3
作者 周德源 刘凌飞 朱立猛 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第8期2083-2091,共9页
A method is developed to predict the lateral load-carrying capacity of composite shear walls with double steel plates and filled concrete with binding bars(SCBs). Nonlinear finite element models of SCBs were establish... A method is developed to predict the lateral load-carrying capacity of composite shear walls with double steel plates and filled concrete with binding bars(SCBs). Nonlinear finite element models of SCBs were established by using the finite element tool, Abaqus. Tie constraints were used to connect the binding bars and the steel plates. Surface-to-surface contact provided by the Abaqus was used to simulate the interaction between the steel plate and the core concrete. The established models could predict the lateral load-carrying capacity of SCBs with a reasonable degree of accuracy. A calculation method was developed by superposition principle to predict the lateral load-carrying capacity of SCBs for the engineering application. The concrete confined by steel plates and binding bars is under multi-axial compression; therefore, its shear strength was calculated by using the Guo-Wang concrete failure criterion. The shear strength of the steel plates of SCBs was calculated by using the von Mises yielding criterion without considering buckling. Results of the developed method are in good agreement with the testing and finite element results. 展开更多
关键词 composite shear wall double steel plate binding bar lateral load-carrying capacity nonlinear finite element analysis
下载PDF
Improving behavior of semi-supported steel plate shear walls
4
作者 Ali GHAMARI Abbas AKBARPOUR Ali GHANBARI 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第10期2891-2905,共15页
In spite of the good performance of the steel plate shear wall(SPSW)in recent earthquakes and experimental studies,the need for huge columns to surround the infill plate is a major shortcoming of the system.This short... In spite of the good performance of the steel plate shear wall(SPSW)in recent earthquakes and experimental studies,the need for huge columns to surround the infill plate is a major shortcoming of the system.This shortcoming can be resolved by using semi-supported SPSW.The semi-supported SPSW has secondary columns that prevent the transfer of stress from the infill plate to the main columns.In spite of extensive experimental and numerical investigations on SPSWs,there are many ambiguities regarding the behavior of the semi-supported SPSW.Although stress in the columns is reduced,incomplete diagonal tension field action is formed in the infill plate that creates new problems.In this paper,a new type of semi-supported SPSW is presented in which the steel plate and the secondary columns are angled.The creation of the angle of the plate and the secondary column makes it possible to use the full capacity of the steel plate as well as the capacity of the secondary columns.Numerical results showed that the wall with a 60°angle has a favorable performance relative to the semi-supported wall.Moreover,with the 60°angle,stiffness,strength and energy absorption is increased.The angle of the secondary columns has little effect on the non-elastic stiffness.Nevertheless,using a wall with an angle of more than 90°can neutralize the wall’s behavior relative to conventional walls.Therefore,the wall with a 60°angle as an optimal angle is recommended. 展开更多
关键词 steel plate shear wall(SPSW) DUCTILITY STIFFNESS ultimate strength R factor
下载PDF
Experimental and analytical study on seismic behavior of steel-concrete multienergy dissipation composite shear walls 被引量:5
5
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Qiao Qiyun Yu Chuanpeng 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第1期125-139,共15页
In this paper, a steel-concrete multi-energy dissipation composite shear wall, comprised of steel-reinforced concrete (SRC) columns, steel plate (SP) deep beams, a concrete wall and energy dissipation strips, is p... In this paper, a steel-concrete multi-energy dissipation composite shear wall, comprised of steel-reinforced concrete (SRC) columns, steel plate (SP) deep beams, a concrete wall and energy dissipation strips, is proposed. In order to study the multi-energy dissipation behavior and restorability after an earthquake, two stages of low cyclic loading tests were carded out on ten test specimens. In the first stage, test on five specimens with different number of SP deep beams was carried out, and the test lasted until the displacement drift reached 2%. In the second stage, thin SPs were welded to both sides of the five specimens tested in the first stage, and the same test was carried out on the repaired specimens (designated as new specimens). The load-bearing capacity, stiffness, ductility, hysteretic behavior and failure characteristics were analyzed for both stages and the results are discussed herein. Extrapolating from these results, strength calculation models and formulas are proposed herein and simulations using ABAQUS carried out, they show good agreement with the test results. The study demonstrates that SRC columns, SP deep beams, concrete wall and energy dissipation strips cooperate well and play an important role in energy dissipation. In addition, this study shows that the shear wall has good recoverability after an earthquake, and that the welding of thin SP's to repair a deformed wall is a practicable technique. 展开更多
关键词 steel reinforced concrete steel plate deep beam multi energy dissipation composite shear wall seismic behavior
下载PDF
Study on the Structural Performance of Steel Plate Shear Wall with Slits on Both Sides
6
作者 Yuchen Liu Heesung Kim 《International Journal of Technology Management》 2015年第7期121-123,共3页
This paper presents a new type of two sides slotted steel plate shear wall, and carries on the analysis to the finite element elastic buckling, respectively discusses the critical buckling load and the buckling mode. ... This paper presents a new type of two sides slotted steel plate shear wall, and carries on the analysis to the finite element elastic buckling, respectively discusses the critical buckling load and the buckling mode. For the steel plate shear wall without stiffening ribs on both sides, the paper given the buckling coefficient formula, and give design proposal and reference value of steel plate shear wall with stiffened on both sides. 展开更多
关键词 steel plate shear wall elastic buckling ultimate load-carrying capacity
下载PDF
An effective simplified model of composite compression struts for partially-restrained steel frame with reinforced concrete infill walls 被引量:2
7
作者 Sun Guohua Chuang-Sheng Walter Yang +1 位作者 Gu Qiang Reginald DesRoches 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2018年第2期403-415,共13页
To resolve the issue regarding inaccurate prediction of the hysteretic behavior by micro-based numerical analysis for partially-restrained(PR)steel frames with solid reinforced concrete(RC)infill walls,an innovati... To resolve the issue regarding inaccurate prediction of the hysteretic behavior by micro-based numerical analysis for partially-restrained(PR)steel frames with solid reinforced concrete(RC)infill walls,an innovative simplified model of composite compression struts is proposed on the basis of experimental observation on the cracking distribution,load transferring mechanism,and failure modes of RC infill walls filled in PR steel frame.The proposed composite compression struts model for the solid RC infill walls is composed ofαinclined struts and main diagonal struts.Theαinclined struts are used to reflect the part of the lateral force resisted by shear connectors along the frame-wall interface,while the main diagonal struts are introduced to take into account the rest of the lateral force transferred along the diagonal direction due to the complicated interaction between the steel frame and RC infill walls.This study derives appropriate formulas for the effective widths of theαinclined strut and main diagonal strut,respectively.An example of PR steel frame with RC infill walls simulating simulated by the composite inclined compression struts model is illustrated.The maximum lateral strength and the hysteresis curve shape obtained from the proposed composite strut model are in good agreement with those from the test results,and the backbone curve of a PR steel frame with RC infill walls can be predicted precisely when the inter-story drift is within 1%.This simplified model can also predict the structural stiffness and the equivalent viscous damping ratio well when the inter-story drift ratio exceeds 0.5%. 展开更多
关键词 PR connection steel frame infill walls shear connector hysteretic behavior STRUT
下载PDF
Seismic behavior and mechanism analysis of innovative precast shear wall involving vertical joints 被引量:3
8
作者 孙建 邱洪兴 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第4期1536-1547,共12页
To study the seismic performance and load-transferring mechanism of an innovative precast shear wall(IPSW) involving vertical joints, an experimental investigation and theoretical analysis were successively conducted ... To study the seismic performance and load-transferring mechanism of an innovative precast shear wall(IPSW) involving vertical joints, an experimental investigation and theoretical analysis were successively conducted on two test walls. The test results confirm the feasibility of the novel joints as well as the favorable seismic performance of the walls, even though certain optimization measures should be taken to improve the ductility. The load-transferring mechanism subsequently is theoretically investigated based on the experimental study. The theoretical results show the load-transferring route of the novel joints is concise and definite. During the elastic stage, the vertical shear stress in the connecting steel frame(CSF) distributes uniformly; and each high-strength bolt(HSB)primarily delivers vertical shear force. However, the stress in the CSF redistributes when the walls develop into the elastic-plastic stage. At the ultimate state, the vertical shear stress and horizontal normal stress in the CSF distribute linearly; and the HSBs at both ends of the CSF transfer the maximum shear forces. 展开更多
关键词 precast shear wall vertical joint seismic behavior high-strength bolt connecting steel frame
下载PDF
Self-centering steel plate shear walls for improving seismic resilience 被引量:2
9
作者 Patricia M. CLAYTON Daniel M. DOWDEN +4 位作者 Chao-Hsien LI Jeffrey W. BERMAN Michel BRUNEAU Laura N. LOWES Keh-Chuan TSAI 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2016年第3期283-290,共8页
As part of a Network for Earthquake Engineering Simulation research project led by researchers at the University of Washington with collaborators at University at Buffalo, and Taiwan National Center for Research on Ea... As part of a Network for Earthquake Engineering Simulation research project led by researchers at the University of Washington with collaborators at University at Buffalo, and Taiwan National Center for Research on Earthquake Engineering, a self-centering steel plate shear wall (SC-SPSW) system has been developed to achieve enhanced seismic performance objectives, including recentering. The SC-SPSW consists of thin steel infill panels, referred to as web plates that serve as the primary lateral load-resisting and energy dissipating element of the system. Post- tensioned (PT) beam-to-column connections provide system recentering capabilities. A performance-based design procedure has been developed for the SC-SPSW, and a series of nonlinear response history analyses have been conducted to verify intended seismic performance at multiple hazard levels. Quasi-static subassembly tests, quasi-static and shake table tests of scaled three-story specimens, and pseudo-dynamic tests of two full-scale two-story SC-SPSWs have been conducted. As a culmination of this multi-year, multi-institutional project, this paper will present an overview of the SC- SPSW numerical and experimental research programs. This paper will also discuss innovative PT connection and web plate designs that were investigated to improve constructability, resilience, and seismic performance and that can be applied to other self-centering and steel plate shear wall systems. 展开更多
关键词 SELF-CENTERING steel plate shear walls large-scale experiment post-tensioned connections performance-baseddesign
原文传递
Pseudo-dynamic testing of a fabricated composite frame with steel plate shear walls 被引量:3
10
作者 Zheng-gang CAO Peng DU +1 位作者 Feng FAN Zhe-ming CHEN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2017年第6期454-466,共13页
A pseudo-dynamic testing program was generated on a fabricated composite frame with steel plate shear walls (SPSWs) to study its seismic perlbrmance. The specimen was a three-storey single-bay frame, which was compo... A pseudo-dynamic testing program was generated on a fabricated composite frame with steel plate shear walls (SPSWs) to study its seismic perlbrmance. The specimen was a three-storey single-bay frame, which was composed of H- section steel columns and composite beams, and was assembled by bolted height-adjustable steel beam-to-column connections (BHA connections). Beam-only-connected SPSWs were selected as lateral load resisting members. The specimen was subjected to four ground motions of progressively increasing intensity. The results showed that: (1) beam-only-connected S PSWs provided sufficient lateral load resistance, lateral stiffness, and energy dissipation capacity to the fabricated frame via the tension ficld action developed in their infill panels; (2) the fabricated frame, assembled by BHA connections, exhibited substantial redundancy and good ductility; (3) an undesirable failure mode of the fabricated frame, in huge earthquakes, included severe cracking in composite beams and block shear failure in SPSWs' connections; (4) the inter-storey shear force distribution determined by ASCE/SE1 7-10 was verified with experimental data. 展开更多
关键词 Fabricated frame Composite beam steel plate shear walls Pseudo-dynamic test
原文传递
Lateral stiffness of steel plate shear walls 被引量:2
11
作者 NIE JianGuo ZHU Li 《Science China(Technological Sciences)》 SCIE EI CAS 2014年第1期151-162,共12页
The steel plate shear wall system has been used in a number of buildings as an innovative lateral force resistant system.Openings often exist in the steel plate shear walls due to the various functional requirements o... The steel plate shear wall system has been used in a number of buildings as an innovative lateral force resistant system.Openings often exist in the steel plate shear walls due to the various functional requirements of structures.These openings may negatively impact the lateral stiffness of steel plate shear walls.Therefore,an experimental research was instituted to investigate the seismic behavior of steel plate shear walls,with and without openings.The experimental results showed that steel plate shear walls have the satisfying seismic behavior,and,as expected,the strength and stiffness characteristics of the walls were reduced due to openings.Then a single-story wall panel FE model and an analytical deep beam model are developed in order to find the critical factors dominating the thickness reduction coefficient of wall panels with the opening.Furthermore,extensive parametric analysis is conducted to derive a simplified formula for the determination of the thickness reduction coefficient of wall panels with the opening for substituting solid wall panels with reduced thickness for actual wall panels with the opening.Finally,the design method for calculating the lateral stiffness is verified by some experimental programs and recommended for the routine practice of steel plate shear walls. 展开更多
关键词 steel plate shear walls wall panels with the opening thickness reduction coefficient lateral stiffness design method analytical deep beam model
原文传递
Numerical modeling of seismic behavior of ellipse and peanut-shaped auxetic steel plate shear walls
12
作者 Junjie Wang Yazhi Zhu Xiaoning Cai 《Low-carbon Materials and Green Construction》 2023年第1期112-131,共20页
This study proposes a new auxetic-shaped steel plate shear walls(simply referred to as ASSPSWs)consisting of boundary members and built-in perforated infill plates.The connection type between the boundary members is a... This study proposes a new auxetic-shaped steel plate shear walls(simply referred to as ASSPSWs)consisting of boundary members and built-in perforated infill plates.The connection type between the boundary members is a hinge joint.The hole forms on the infill plates include orthogonal ellipse-shaped(ASSPSW-OE)and orthogonal peanutshaped(ASSPSW-OP).This paper studied the hysteretic performance of two steel plate shear walls’types based on the finite element analysis method.Within the study context,a parametric analysis was carried out to investigate the influence of various factors,such as hole size and hole distance,on the seismic performance of steel plate shear walls(SPSWs).The results indicated that reducing the the ratio of the ligament thickness to ellipse major axis(t/D)in orthogonal ellipse-shaped SPSWs can effectively increase the porosity while reducing the bearing and energy dissipation capacities.Under the condition with the t/D unchanged,increasing the ratio of the major to minor axis of the ellipse(d/D)raises the porosity and does not significantly reduce the bearing capacity and energy dissipation capacity of the SPSWs.For orthogonal peanut-shaped SPSWs,the holes’geometrical parameters significantly influence the hysteretic performance.Particularly,with the increase in the radial ratio of large to small circles in a peanut-shaped hole(R/r),the spacing between cells decreases.When drift exceeds 2%,the equivalent viscous damping ratio decreases sharply.Unlike the orthogonal ellipse-shaped SPSWs,changing the arrangement angle of peanut-shaped cells has no significant effect on orthogonal peanut-shaped SPSWs.However,the larger the angle,the greater the out-of-plane buckling of orthogonal ellipse-shaped SPSWs;thus,the energy dissipation capacity is reduced.The similarities lie in that the larger cell arrangement angle will make the steel plates have a complete stress field,and the bearing capacity will be slightly improved.When the cell arrangement angle(θ)is 45°,the SPSWs can develop high initial stiffness. 展开更多
关键词 AUXETICS steel plate shear wall Ellipse shape Peanut shape Cyclic loading Hysteresis response
原文传递
钢板混凝土墙-钢筋混凝土楼板连接节点抗剪性能
13
作者 于跃 隋春光 +1 位作者 雷永旺 郭全全 《哈尔滨工业大学学报》 EI CAS 北大核心 2025年第1期92-100,共9页
模块化技术正在推动新一代核电厂的设计和发展,兼具优良工作性能和工业化施工性能的钢板混凝土(SC)结构在模块化结构具有广泛应用前景。SC墙-RC楼板连接节点作为SC模块结构与RC结构之间的典型传力构件,其结构设计必须既要保证荷载的有... 模块化技术正在推动新一代核电厂的设计和发展,兼具优良工作性能和工业化施工性能的钢板混凝土(SC)结构在模块化结构具有广泛应用前景。SC墙-RC楼板连接节点作为SC模块结构与RC结构之间的典型传力构件,其结构设计必须既要保证荷载的有效传递,又要考虑模块化施工的可行性。为研究SC墙-RC楼板连接节点抗剪性能,设计并完成了2个“薄墙厚板型”SC墙-RC楼板连接节点循环加载试验,包括GB/T 51340—2018建议的钢筋连接器连接、附加抗剪键等两种连接方式。试验结果表明:在剪跨比1.50下试件均发生RC楼板弯剪破坏,节点主要传力破坏路径为加载端至楼板根部的斜压杆区域,说明节点结合面不配置抗剪键仍满足抗剪要求;试验过程中,直螺纹钢筋套筒无滑脱、未发生钢筋或焊缝拉断,延性系数均大于4,说明钢筋连接器连接的传力性能良好,可作为SC墙-RC楼板连接节点的有效连接方式;该节点核心区仍属于抗剪薄弱区域,若要满足“全强度连接”设计准则,核心区对拉筋体积含钢率应不低于0.59%。 展开更多
关键词 钢板混凝土墙 钢筋混凝土楼板 连接节点 钢筋连接器 抗剪键
下载PDF
Experimental research on the seismic behavior of CSPSWs connected to frame beams 被引量:1
14
作者 Guo Lanhui Ma Xinbo Li Ran Zhang Sumei 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2011年第1期65-73,共9页
The seismic performance of composite steel plate shear walls (CSPSWs) that consist of a steel plate shear wall (SPSW) with reinforced concrete (RC) panels attached to one or both sides by means of bolts or conne... The seismic performance of composite steel plate shear walls (CSPSWs) that consist of a steel plate shear wall (SPSW) with reinforced concrete (RC) panels attached to one or both sides by means of bolts or connectors is experimentally studied. The shear wall is connected to the frame beams but not to the columns. This arrangement restrains the possible out-of-plane buckling of the thin-walled steel plate, thus significantly increasing the bearing capacity and ductility of the overall wall, and prevents the premature overall or local buckling failure of the frame columns. From a practical viewpoint, these solutions can provide open space in a floor as this type of composite shear walls with a relatively small aspect ratio can be placed parallel along a bay. In this study, four CSPSWs and one SPSW were tested and the results showed that both CSPSWs and SPSW possessed good ductility. For SPSW alone, the buckling appeared and resulted in a decrease of bearing capacity and energy dissipation capacity. In addition, welding stiffeners at corners were shown to be an effective way to increase the energy dissipation capacity of CSPSWs. 展开更多
关键词 steel plate shear wall (SPSW) composite steel plate shear wall (CSPSW) seismic behavior DUCTILITY
下载PDF
焊接多腔双钢板-混凝土组合剪力墙抗震性能分析 被引量:1
15
作者 丁发兴 蔡勇强 +3 位作者 王莉萍 孙浩 吕飞 黄修文 《华南理工大学学报(自然科学版)》 EI CSCD 北大核心 2024年第1期15-25,共11页
大多数双钢板-混凝土组合剪力墙采用螺栓连接或焊接肋的方式使钢板和混凝土协同工作。然而,这种连接方式可能导致整体性和塑性变形效率较低,且制作复杂,焊接多腔双钢板-混凝土组合剪力墙能够有效地避免这些问题。为了深入研究焊接多腔... 大多数双钢板-混凝土组合剪力墙采用螺栓连接或焊接肋的方式使钢板和混凝土协同工作。然而,这种连接方式可能导致整体性和塑性变形效率较低,且制作复杂,焊接多腔双钢板-混凝土组合剪力墙能够有效地避免这些问题。为了深入研究焊接多腔双钢板-混凝土组合剪力墙的抗震性能,基于约束混凝土真三轴塑性-损伤本构模型和钢材弹塑性混合强化-韧性损伤本构模型,建立了组合剪力墙的精细化三维实体-壳模型,将模拟所得的滞回曲线、骨架曲线、刚度退化曲线、弹性刚度、承载力、累积耗能、等效阻尼粘滞系数和延性系数与已有拟静力试验结果相比较,发现两者吻合较好。分析结果表明:轴压比对组合剪力墙模型算例刚度和承载力的影响较小,而随剪跨比增大,组合剪力墙模型算例的刚度和承载力呈线性降低;轴压比对组合剪力墙模型算例总塑性耗能的影响较小,而剪跨比的影响较大,剪力墙总塑性耗能随剪跨比增大而降低;轴压比和剪跨比都不会改变算例各部件的耗能分配机制,即组合剪力墙模型算例以外钢板和内隔板耗能为主。 展开更多
关键词 双钢板-混凝土组合剪力墙 抗震性能 塑性耗能 有限元分析
下载PDF
联肢弯剪型钢板剪力墙抗震性能试验研究
16
作者 郝际平 兰芮 +6 位作者 田炜烽 薛强 李生辉 樊春雷 徐坤 朱邵辉 王洪臣 《建筑钢结构进展》 CSCD 北大核心 2024年第4期10-19,共10页
联肢钢板剪力墙结构是将2片钢板剪力墙通过钢连梁连接形成的抗侧力结构。通过对1榀1/3缩尺的4层联肢弯剪型钢板剪力墙试件进行低周往复加载试验,从滞回曲线、骨架曲线、延性、承载力及刚度退化、耗能能力等方面研究了该结构体系的抗震性... 联肢钢板剪力墙结构是将2片钢板剪力墙通过钢连梁连接形成的抗侧力结构。通过对1榀1/3缩尺的4层联肢弯剪型钢板剪力墙试件进行低周往复加载试验,从滞回曲线、骨架曲线、延性、承载力及刚度退化、耗能能力等方面研究了该结构体系的抗震性能,并且对试件的屈服顺序和变形模式进行了分析。结果表明:联肢钢板剪力墙试件的延性系数达到5.03,承载力退化系数均大于0.96,承载力和刚度退化稳定,等效黏滞阻尼系数达到0.25以上,表明联肢弯剪型钢板剪力墙具有优越的抗震性能。加载过程中,连梁先于墙板发生屈服,墙板先屈曲后屈服,此后柱脚和横梁相继屈服。连梁的引入改变了结构的屈服机制,提高了整体的延性和耗能能力,能够组成多道抗震防线,且试件整体最终也体现出合理的破坏机制。整体侧移曲线呈弯剪变形模式。该试验研究更加贴合实际工程中联肢钢板剪力墙结构的应用情况,为联肢钢板剪力墙结构的进一步研究和应用提供了试验基础。 展开更多
关键词 联肢钢板剪力墙 低周往复加载试验 抗震性能 屈服机制 变形模式
下载PDF
带PBL剪力键的钢芯板混凝土组合剪力墙低周往复加载试验研究
17
作者 袁涛涛 蔡玉军 +1 位作者 聂少锋 隋璐 《建筑科学与工程学报》 CAS 北大核心 2024年第5期42-51,共10页
为研究带PBL剪力键的钢芯板混凝土组合剪力墙的抗震性能,对1个型钢混凝土组合剪力墙和4个钢芯板混凝土组合剪力墙进行了循环往复加载试验;观察带PBL剪力键的钢芯板混凝土组合剪力墙在水平循环荷载下的破坏全过程,并分析该类剪力墙的滞... 为研究带PBL剪力键的钢芯板混凝土组合剪力墙的抗震性能,对1个型钢混凝土组合剪力墙和4个钢芯板混凝土组合剪力墙进行了循环往复加载试验;观察带PBL剪力键的钢芯板混凝土组合剪力墙在水平循环荷载下的破坏全过程,并分析该类剪力墙的滞回特征、变形能力、承载能力、耗能性能、刚度和强度退化能力。结果表明:钢芯板混凝土组合剪力墙的破坏模式主要为弯曲型破坏,滞回曲线较为饱满;配置钢芯板的剪力墙承载力、延性性能和耗能能力较优;PBL剪力键的构造方式可保证钢芯板与混凝土之间的黏结性能完好,PBL剪力键平放会导致剪力墙出现沿PBL剪力键的水平通缝,影响剪力墙承载能力的发挥,建议采用PBL剪力键竖放的构造形式。 展开更多
关键词 钢芯板混凝土组合剪力墙 PBL剪力键 抗震性能 拟静力试验
下载PDF
冷弯薄壁型钢-结构防火一体板自攻螺钉连接性能试验研究
18
作者 熊刚 折志伟 +3 位作者 李环宇 石宇 刘宜丰 姜雪 《土木与环境工程学报(中英文)》 CSCD 北大核心 2024年第3期134-143,共10页
开展冷弯薄壁型钢-结构防火一体板自攻螺钉连接抗剪性能试验研究,完成35个典型试件单调拉伸及低周往复加载试验,分析结构防火一体板厚度、螺钉直径、螺钉端距及加载角度等因素对其抗剪性能的影响。结果表明:不同加载角度及螺钉端距的试... 开展冷弯薄壁型钢-结构防火一体板自攻螺钉连接抗剪性能试验研究,完成35个典型试件单调拉伸及低周往复加载试验,分析结构防火一体板厚度、螺钉直径、螺钉端距及加载角度等因素对其抗剪性能的影响。结果表明:不同加载角度及螺钉端距的试件呈现不同的破坏模式,主要包括板材端部撕裂破坏、板材孔壁承压破坏、板材被拉断破坏等,且破坏时试件的自攻螺钉存在不同程度的倾斜。对于试验端分别采用直径为4.8、5.5 mm螺钉的试件,试件的峰值荷载及延性系数与螺钉直径无明显相关性,弹性刚度随着螺钉直径增大而显著提升;随着螺钉端距由15 mm增大至25 mm,试件的弹性刚度无明显变化,而峰值荷载和延性系数提高了约35%;随着板厚由12 mm增大到20 mm,试件的峰值荷载提高了约40%,弹性刚度提高了约90%,延性系数降低了约30%;与加载角度为0°的试件的特征参数相比,加载角度为45°时,试件弹性刚度提高了约100%,峰值荷载及延性系数无明显差别;加载角度为90°时,试件弹性刚度及峰值荷载无明显差别,延性系数降低了约40%。 展开更多
关键词 冷弯薄壁型钢 结构防火一体板 螺钉连接 抗剪性能 低周往复荷载
下载PDF
自攻螺钉与拉铆钉混合连接受剪承载性能试验
19
作者 褚云朋 伏金蓉 +1 位作者 钟志豪 陈晓强 《工程科学与技术》 EI CAS CSCD 北大核心 2024年第4期88-97,共10页
为改善自攻螺钉连接的构件在地震作用下易发生拉脱导致结构严重破坏的缺点,提升冷弯薄壁型钢组合墙体抗破坏能力,分析了组合墙体层间连接处的传力机理,针对自攻螺钉的破坏模式,提出拉铆钉与自攻螺钉混合连接。为研究混合连接的抗剪性能... 为改善自攻螺钉连接的构件在地震作用下易发生拉脱导致结构严重破坏的缺点,提升冷弯薄壁型钢组合墙体抗破坏能力,分析了组合墙体层间连接处的传力机理,针对自攻螺钉的破坏模式,提出拉铆钉与自攻螺钉混合连接。为研究混合连接的抗剪性能,共进行了48组连接接头抗剪性能试验,包含冷弯薄壁型钢结构常用的5种连接板厚度,不同搭接板厚比(变化范围1.0~2.0),包含纯自攻螺钉连接、纯拉铆钉连接及混合连接的连接方式。观察混合连接的破坏模式,自攻螺钉未发现拉脱破坏,其破坏模式主要表现为:板承压破坏与螺钉倾斜组合破坏、铆钉剪断破坏及板承压与铆钉部分剪断组合破坏3种;相较单一连接方式,混合连接荷载–位移曲线表现出更长的塑性阶段;当板厚比大于1.5且组合板厚小于3.0mm,混合连接的承载力及延性较单一连接增长明显;利用现有计算方法对混合连接的承载力进行累加计算,与试验结果对比,计算结果偏保守。研究发现:混合连接能较好地弥补拉铆钉和自攻螺钉受剪过程中的缺陷,有效改善自攻螺钉拉脱破坏,从而提升连接的承载力及延性;板厚和板厚比是影响混合连接破坏模式及承载力的重要因素,与单一连接相比,板厚比越大,承载力提升越大;排布方式对混合连接的力学性能及破坏机理影响有限;在本文试验工况下,结合混合连接的破坏模式,在现有计算方法的基础上,提出改善后的计算方法,其计算结果更合理。 展开更多
关键词 拉铆钉连接 拉铆钉-螺钉混合连接 组合墙体 受剪性能 抗剪承载力计算方法
下载PDF
低周反复荷载下T型双波纹钢板混凝土组合剪力墙受力性能试验研究
20
作者 陈宗平 莫琳琳 +1 位作者 许新颖 唐际宇 《工程力学》 EI CSCD 北大核心 2024年第6期87-104,共18页
为研究低周反复荷载下T型双波纹钢板混凝土组合剪力墙的受力性能,对5个T型双波纹钢板混凝土组合剪力墙进行了低周反复加载试验。基于试验数据,分析了T型组合剪力墙的破坏模式、滞回曲线、变形能力及耗能能力,重点研究了边缘约束条件、... 为研究低周反复荷载下T型双波纹钢板混凝土组合剪力墙的受力性能,对5个T型双波纹钢板混凝土组合剪力墙进行了低周反复加载试验。基于试验数据,分析了T型组合剪力墙的破坏模式、滞回曲线、变形能力及耗能能力,重点研究了边缘约束条件、波纹类型以及轴压比不同变化参数对T型组合剪力墙抗震性能指标的影响规律。研究结果表明:T型双波纹钢板混凝土组合剪力墙破坏模式主要有压屈破坏和压弯破坏两种;设置边缘约束构件是提高T型双波纹钢板混凝土组合剪力墙承载能力和变形能力的关键因素;纵向窄波纹钢板对内部混凝土的约束能力更强,在低周反复荷载下两者协同工作性更优,而横向窄波纹钢板试件强度退化最严重;采用全截面塑性设计方法进行T型双波纹钢板混凝土组合剪力墙正截面承载力计算,试验值与计算值吻合良好;T型双波纹钢板混凝土组合剪力墙具有较好的承载能力和变形能力,可适用于高层及超高层建筑结构中。 展开更多
关键词 T型组合剪力墙 双波纹钢板 低周反复荷载 钢板类型 承载力计算
下载PDF
上一页 1 2 57 下一页 到第
使用帮助 返回顶部