The represent paper will study the performance of the power plant with the combination of dry and wet cooling systems in different operating conditions. A thermodynamic performance analysis of the steam cycle system w...The represent paper will study the performance of the power plant with the combination of dry and wet cooling systems in different operating conditions. A thermodynamic performance analysis of the steam cycle system was performed by means of a program code dedicated to power plant modeling in design operating condition. Then the off-design behavior was studied by varying not only the ambient temperature and relative humidity but also several parameters connected to the cooling performance, like the exhaust steam flow rate, the air cooling fan load and the number of operating cooling water pumps and cooling towers. The result is an optimum set of variables allowing the dry and wet cooling system be regulated in such a way that the maximum power is achieved and low water consumption.展开更多
A compliant tower is modeled as a partially dry, partially tapered, damped Timoshenko beam with the superstructure modeled as an eccentric tip mass, and a non-classical damped boundary at the base. The foundation is m...A compliant tower is modeled as a partially dry, partially tapered, damped Timoshenko beam with the superstructure modeled as an eccentric tip mass, and a non-classical damped boundary at the base. The foundation is modeled as a combination of a linear spring and a torsional spring, along with parallel linear and torsional dampers(Kelvin-Voigt model). The superstructure adds to the kinetic energy of the system without affecting the potential energy, thereby reducing the natural frequencies. The weight of the superstructure acts as an axial compressive load on the beam, reducing its natural frequencies further. The empty space factor due to the truss-type structure of the tower is included. The effect of shear deformation and rotary inertia are included in the vibration analysis; with the non-uniform beam mode-shapes being a weighted sum of the uniform beam mode-shapes satisfying the end condition. The weights are evaluated by the Rayleigh-Ritz(RR) method, and verified using finite element method(FEM). The weight of the superstructure acts as an axial compressive load on the beam. Kelvin-Voigt model of structural damping is included.A part of the structure being underwater, the virtual added inertia is included to calculate the wet natural frequencies. A parametric study is done for various magnitudes of tip mass and various levels of submergence. The computational efficiency and accuracy of the Rayleigh-Ritz method, as compared to the FEA, has been demonstrated. The advantage of using closed-form trial functions is clearly seen in the efficacy of calculating the various energy components in the RR method.展开更多
文摘The represent paper will study the performance of the power plant with the combination of dry and wet cooling systems in different operating conditions. A thermodynamic performance analysis of the steam cycle system was performed by means of a program code dedicated to power plant modeling in design operating condition. Then the off-design behavior was studied by varying not only the ambient temperature and relative humidity but also several parameters connected to the cooling performance, like the exhaust steam flow rate, the air cooling fan load and the number of operating cooling water pumps and cooling towers. The result is an optimum set of variables allowing the dry and wet cooling system be regulated in such a way that the maximum power is achieved and low water consumption.
文摘A compliant tower is modeled as a partially dry, partially tapered, damped Timoshenko beam with the superstructure modeled as an eccentric tip mass, and a non-classical damped boundary at the base. The foundation is modeled as a combination of a linear spring and a torsional spring, along with parallel linear and torsional dampers(Kelvin-Voigt model). The superstructure adds to the kinetic energy of the system without affecting the potential energy, thereby reducing the natural frequencies. The weight of the superstructure acts as an axial compressive load on the beam, reducing its natural frequencies further. The empty space factor due to the truss-type structure of the tower is included. The effect of shear deformation and rotary inertia are included in the vibration analysis; with the non-uniform beam mode-shapes being a weighted sum of the uniform beam mode-shapes satisfying the end condition. The weights are evaluated by the Rayleigh-Ritz(RR) method, and verified using finite element method(FEM). The weight of the superstructure acts as an axial compressive load on the beam. Kelvin-Voigt model of structural damping is included.A part of the structure being underwater, the virtual added inertia is included to calculate the wet natural frequencies. A parametric study is done for various magnitudes of tip mass and various levels of submergence. The computational efficiency and accuracy of the Rayleigh-Ritz method, as compared to the FEA, has been demonstrated. The advantage of using closed-form trial functions is clearly seen in the efficacy of calculating the various energy components in the RR method.