The performance of a Venturi tube used in wet gas flow have been explored mainly under higher-pressure condition, but very often, low-pressure test exists in some oil and gas fields in Tianjin Dagang Oil and Gas Field...The performance of a Venturi tube used in wet gas flow have been explored mainly under higher-pressure condition, but very often, low-pressure test exists in some oil and gas fields in Tianjin Dagang Oil and Gas Field in China. In this study, the performance of horizontally mounted Venturi meters in low-pressure wet gas flow is discussed. Three 50 mm Venturi meters were tested systematically, with fl values of 0.4048, 0.55 and 0.70, the opera- tion pressure of 0.15 MPa, 0.20 MPa, 0.25 MPa, the gas densiometric Froude number from 0.6 to 2.0, the modified Lockhart-Maretinelli parameter from 0.0022 to 0.06, and the ratio of the gas liquid mass flow rate from 0.5 to 0.99. The effects of modified Lockhart-Maretinelli parameter, pressure, gas densiometric Froude number, diameter ratio, and gas-liquid mass flow rate ratio to the Venturi tube are analyzed with new independent data. Furthermore, low-pressure performance was compared with that under high pressure.展开更多
A slotted orifice has many superiorities over a standard orifice. For single-phase flow measurement, its flow coefficient is insensitive to the upstream velocity profile. For two phase flow measurement, various charac...A slotted orifice has many superiorities over a standard orifice. For single-phase flow measurement, its flow coefficient is insensitive to the upstream velocity profile. For two phase flow measurement, various characteristics of its differential pressure (DP) are stable and closely correlated with the mass flow rate of gas and liquid. The complex relationships between the signal features and the two-phase flow rate are established through the use of a back propagation (BP) neural network. Experiments were carried out in the horizontal tubes with 50ram inner diameter, ooerated with water flow rate in the range of 0.2m^3·h^-1 to 4m3·h^-1, gas flow rate in the range of 100m^3·h^-1 to 1000m^3·h^-1, and pressure at 400kPa and 850kPa respectively, where the temperature is ambient temperature. This article includes the principle of wet gas meter development, the experimental matrix, the signal processing techniques and the achieved results. On the basis of the results it is suggested that the slotted orifice couple with a trained neural network may provide a simple but efficient solution to the wet gas meter development.展开更多
基金the National High Technology Research and Development Program of China(2006AA04Z167,2007AA04Z180)
文摘The performance of a Venturi tube used in wet gas flow have been explored mainly under higher-pressure condition, but very often, low-pressure test exists in some oil and gas fields in Tianjin Dagang Oil and Gas Field in China. In this study, the performance of horizontally mounted Venturi meters in low-pressure wet gas flow is discussed. Three 50 mm Venturi meters were tested systematically, with fl values of 0.4048, 0.55 and 0.70, the opera- tion pressure of 0.15 MPa, 0.20 MPa, 0.25 MPa, the gas densiometric Froude number from 0.6 to 2.0, the modified Lockhart-Maretinelli parameter from 0.0022 to 0.06, and the ratio of the gas liquid mass flow rate from 0.5 to 0.99. The effects of modified Lockhart-Maretinelli parameter, pressure, gas densiometric Froude number, diameter ratio, and gas-liquid mass flow rate ratio to the Venturi tube are analyzed with new independent data. Furthermore, low-pressure performance was compared with that under high pressure.
基金Supported by the National Natural Science Foundation of China (No.60672003)Shandong Key Technology R&D Program (2004GG2205016).
文摘A slotted orifice has many superiorities over a standard orifice. For single-phase flow measurement, its flow coefficient is insensitive to the upstream velocity profile. For two phase flow measurement, various characteristics of its differential pressure (DP) are stable and closely correlated with the mass flow rate of gas and liquid. The complex relationships between the signal features and the two-phase flow rate are established through the use of a back propagation (BP) neural network. Experiments were carried out in the horizontal tubes with 50ram inner diameter, ooerated with water flow rate in the range of 0.2m^3·h^-1 to 4m3·h^-1, gas flow rate in the range of 100m^3·h^-1 to 1000m^3·h^-1, and pressure at 400kPa and 850kPa respectively, where the temperature is ambient temperature. This article includes the principle of wet gas meter development, the experimental matrix, the signal processing techniques and the achieved results. On the basis of the results it is suggested that the slotted orifice couple with a trained neural network may provide a simple but efficient solution to the wet gas meter development.