期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Design of a high sensitivity and wide range angular rate sensor based on exceptional surface
1
作者 丁鑫圣 刘文耀 +7 位作者 王师贤 陶煜 周彦汝 白禹 刘来 邢恩博 唐军 刘俊 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第8期277-286,共10页
It is found that when the parity–time symmetry phenomenon is introduced into the resonant optical gyro system and it works near the exceptional point,the sensitivity can in theory be significantly amplified at low an... It is found that when the parity–time symmetry phenomenon is introduced into the resonant optical gyro system and it works near the exceptional point,the sensitivity can in theory be significantly amplified at low angular rate.However,in fact,the exceptional point is easily disturbed by external environmental variables,which means that it depends on harsh experimental environment and strong control ability,so it is difficult to move towards practical application.Here,we propose a new angular rate sensor structure based on exceptional surface,which has the advantages of high sensitivity and high robustness.The system consists of two fiber-optic ring resonators and two optical loop mirrors,and one of the resonators contains a variable ratio coupler and a variable optical attenuator.We theoretically analyze the system response,and the effects of phase and coupling ratio on the system response.Finally,compared with the conventional resonant gyro,the sensitivity of this exceptional surface angular rate sensor can be improved by about 300 times at low speed.In addition,by changing the loss coefficient in the ring resonator,we can achieve a wide range of 600 rad/s.This scheme provides a new approach for the development of ultra-high sensitivity and wide range angular rate sensors in the future. 展开更多
关键词 exceptional surface exceptional points ring resonator angular rate sensing rotational direction recognition wide operating range
下载PDF
Impact of Typical Steady-state Conditions and Transient Conditions on Flow Ripple and Its Test Accuracy for Axial Piston Pump 被引量:14
2
作者 XU Bing HU Min ZHANG Junhui 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2015年第5期1012-1022,共11页
The current research about the flow ripple of axial piston pump mainly focuses on the effect of the structure of parts on the flow ripple. Therein, the structure of parts are usually designed and optimized at rated wo... The current research about the flow ripple of axial piston pump mainly focuses on the effect of the structure of parts on the flow ripple. Therein, the structure of parts are usually designed and optimized at rated working conditions. However, the pump usually has to work in large-scale and time-variant working conditions. Therefore, the flow ripple characteristics of pump and analysis for its test accuracy with respect to variant steady-state conditions and transient conditions in a wide range of operating parameters are focused in this paper. First, a simulation model has been constructed, which takes the kinematics of oil film within friction pairs into account for higher accuracy. Afterwards, a test bed which adopts Secondary Source Method is built to verify the model. The simulation and tests results show that the angular position of the piston, corresponding to the position where the peak flow ripple is produced, varies with the different pressure. The pulsating amplitude and pulsation rate of flow ripple increase with the rise of pressure and the variation rate of pressure. For the pump working at a constant speed, the flow pulsation rate decreases dramatically with the increasing speed when the speed is less than 27.78% of the maximum speed, subsequently presents a small decrease tendency with the speed further increasing. With the rise of the variation rate of speed, the pulsating amplitude and pulsation rate of flow ripple increase. As the swash plate angle augments, the pulsating amplitude of flow ripple increases, nevertheless the flow pulsation rate decreases. In contrast with the effect of the variation of pressure, the test accuracy of flow ripple is more sensitive to the variation of speed. It makes the test accuracy above 96.20% available for the pulsating amplitude of pressure deviating within a range of ~6% from the mean pressure. However, with a variation of speed deviating within a range of ±2% from the mean speed, the attainable test accuracy of flow ripple is above 93.07%. The model constructed in this research proposes a method to determine the flow ripple characteristics of pump and its attainable test accuracy under the large-scale and time-variant working conditions. Meanwhile, a discussion about the variation of flow ripple and its obtainable test accuracy with the conditions of the pump working in wide operating ranges is given as well. 展开更多
关键词 axial piston pump flow ripple test accuracy steady-state condition transient condition wide operating ranges
下载PDF
Monolithic integration of electroabsorption modulators and tunnel injection distributed feedback lasers using quantum well intermixing
3
作者 汪洋 潘教青 +2 位作者 赵玲娟 朱洪亮 王圩 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第12期328-333,共6页
Electroabsorption modulators combining Franz-Keldysh effect and quantum confined Stark effect have been mono-lithically integrated with tunnel-injection quantum-well distributed feedback lasers using a quantum well in... Electroabsorption modulators combining Franz-Keldysh effect and quantum confined Stark effect have been mono-lithically integrated with tunnel-injection quantum-well distributed feedback lasers using a quantum well intermixing method. Superior characteristics such as extinction ratio and temperature insensitivity have been demonstrated at wide temperature ranges. 展开更多
关键词 electroabsorption modulator tunnel injection wide temperature range operation quantum well intermixing
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部