In this paper, a new predictive control strategy for current source matrix converter (CSMC) is presented. Proposed predictive control strategy allows for creating output voltages with boost type voltage transfer ratio...In this paper, a new predictive control strategy for current source matrix converter (CSMC) is presented. Proposed predictive control strategy allows for creating output voltages with boost type voltage transfer ratio and desired frequency. The description of predictive control circuit of the CSMC is presented. Furthermore the simulation test results to confirm functionality of the proposed control strategy and converter properties under this strategy are shown.展开更多
当电压源换流器型直流输电(voltage source converter based high voltage direct current transmission,VSC-HVDC)联接弱交流电网输送功率接近交流电网静态稳定极限时,经典矢量控制方法无法保证换流器稳定运行。文中分析VSC联接于弱交...当电压源换流器型直流输电(voltage source converter based high voltage direct current transmission,VSC-HVDC)联接弱交流电网输送功率接近交流电网静态稳定极限时,经典矢量控制方法无法保证换流器稳定运行。文中分析VSC联接于弱交流电网时的潮流特性,研究经典矢量控制外环在弱交流电网条件下的特性,通过基于小信号模型的极点分析研究导致换流器无法稳定运行的原因,基于VSC联接于弱交流电网时的失稳机理提出一种改进矢量控制方法,在矢量控制外环增加前馈支路,增加暂态无功响应速度,提高弱交流电网条件下VSC在输送功率接近交流电网静态稳定极限时的稳定性。最后,基于小信号建模的极点分析和时域仿真结果验证改进矢量控制方法的有效性。展开更多
推导了交流电网不平衡情况下电压源换相高压直流输电系统(voltage source converter based high voltage direct current transmission,VSC-HVDC)电磁暂态模型,提出了适用于该场合的抑制直流电压二次波动的控制策略。通过分析αβ坐标与...推导了交流电网不平衡情况下电压源换相高压直流输电系统(voltage source converter based high voltage direct current transmission,VSC-HVDC)电磁暂态模型,提出了适用于该场合的抑制直流电压二次波动的控制策略。通过分析αβ坐标与dq+和dq-坐标之间的变换关系,得出结论:在正序旋转坐标下正序分量为直流量,负序分量是频率为100Hz的交流量;而在负序旋转坐标下负序分量为直流量,正序分量是频率为100Hz的交流量。通过简化交、直流侧电路,建立考虑换相电抗器损耗的交流系统不平衡情况下VSC-HVDC系统电磁暂态数学模型。为了抑制发生不平衡故障时直流电压的二次波动给VSC阀和直流电容器产生额外应力等问题,设计基于正、负序旋转坐标系的双电流内环控制器和直流电压外环控制器。仿真结果证明所提出的数学模型正确、可靠,所提出的控制策略能够有效地抑制直流电压二次波动。展开更多
基于电压源换流器高压直流输电(voltage source converter based HVDC,VSC-HVDC)的直流系统存在与交流线路并联运行的情况。交直流系统之间相互切换的运行工况复杂,且切换过程存在切换依据难以确定、切换冲击大以及通信延时等问题。为...基于电压源换流器高压直流输电(voltage source converter based HVDC,VSC-HVDC)的直流系统存在与交流线路并联运行的情况。交直流系统之间相互切换的运行工况复杂,且切换过程存在切换依据难以确定、切换冲击大以及通信延时等问题。为解决该问题,在分析VSC-HVDC工作原理、数学模型及其控制策略的基础上,提出了一种大型风电场经VSC-HVDC交直流并联系统并网的运行控制策略,该策略在不改变换流站控制方式的情况下,可实现交直流并联系统运行方式的无缝切换。基于MATLAB/Simulink仿真软件,建立了系统仿真模型,对交直流并联系统稳态运行及动态切换过程进行了仿真分析。仿真结果表明,所提出的控制策略能够较好地实现交直流并联系统有功功率的精确分配和运行方式的无缝切换,算法简单,可靠性高。展开更多
建立了含柔性直流输电(voltage source converter based high voltage direct current,VSC-HVDC)的交直流混合发输电系统的可靠性分析模型,该模型既考虑了VSC-HVDC的稳态功率特性,还计及了发输电网络的故障率和输电线路的有功限制,采用...建立了含柔性直流输电(voltage source converter based high voltage direct current,VSC-HVDC)的交直流混合发输电系统的可靠性分析模型,该模型既考虑了VSC-HVDC的稳态功率特性,还计及了发输电网络的故障率和输电线路的有功限制,采用非序惯蒙特卡罗仿真实现;在满足系统安全约束的前提条件下,对系统进行模拟调度,重点评价了与发输电网络连接的VSC-HVDC对电网可靠性的影响,给出系统和节点的风险指标,为VSC-HVDC规划和运行提供参考依据,最后算例分析证明了该算法的可行性和合理性。展开更多
文摘In this paper, a new predictive control strategy for current source matrix converter (CSMC) is presented. Proposed predictive control strategy allows for creating output voltages with boost type voltage transfer ratio and desired frequency. The description of predictive control circuit of the CSMC is presented. Furthermore the simulation test results to confirm functionality of the proposed control strategy and converter properties under this strategy are shown.
文摘当电压源换流器型直流输电(voltage source converter based high voltage direct current transmission,VSC-HVDC)联接弱交流电网输送功率接近交流电网静态稳定极限时,经典矢量控制方法无法保证换流器稳定运行。文中分析VSC联接于弱交流电网时的潮流特性,研究经典矢量控制外环在弱交流电网条件下的特性,通过基于小信号模型的极点分析研究导致换流器无法稳定运行的原因,基于VSC联接于弱交流电网时的失稳机理提出一种改进矢量控制方法,在矢量控制外环增加前馈支路,增加暂态无功响应速度,提高弱交流电网条件下VSC在输送功率接近交流电网静态稳定极限时的稳定性。最后,基于小信号建模的极点分析和时域仿真结果验证改进矢量控制方法的有效性。
文摘推导了交流电网不平衡情况下电压源换相高压直流输电系统(voltage source converter based high voltage direct current transmission,VSC-HVDC)电磁暂态模型,提出了适用于该场合的抑制直流电压二次波动的控制策略。通过分析αβ坐标与dq+和dq-坐标之间的变换关系,得出结论:在正序旋转坐标下正序分量为直流量,负序分量是频率为100Hz的交流量;而在负序旋转坐标下负序分量为直流量,正序分量是频率为100Hz的交流量。通过简化交、直流侧电路,建立考虑换相电抗器损耗的交流系统不平衡情况下VSC-HVDC系统电磁暂态数学模型。为了抑制发生不平衡故障时直流电压的二次波动给VSC阀和直流电容器产生额外应力等问题,设计基于正、负序旋转坐标系的双电流内环控制器和直流电压外环控制器。仿真结果证明所提出的数学模型正确、可靠,所提出的控制策略能够有效地抑制直流电压二次波动。
文摘基于电压源换流器高压直流输电(voltage source converter based HVDC,VSC-HVDC)的直流系统存在与交流线路并联运行的情况。交直流系统之间相互切换的运行工况复杂,且切换过程存在切换依据难以确定、切换冲击大以及通信延时等问题。为解决该问题,在分析VSC-HVDC工作原理、数学模型及其控制策略的基础上,提出了一种大型风电场经VSC-HVDC交直流并联系统并网的运行控制策略,该策略在不改变换流站控制方式的情况下,可实现交直流并联系统运行方式的无缝切换。基于MATLAB/Simulink仿真软件,建立了系统仿真模型,对交直流并联系统稳态运行及动态切换过程进行了仿真分析。仿真结果表明,所提出的控制策略能够较好地实现交直流并联系统有功功率的精确分配和运行方式的无缝切换,算法简单,可靠性高。
文摘建立了含柔性直流输电(voltage source converter based high voltage direct current,VSC-HVDC)的交直流混合发输电系统的可靠性分析模型,该模型既考虑了VSC-HVDC的稳态功率特性,还计及了发输电网络的故障率和输电线路的有功限制,采用非序惯蒙特卡罗仿真实现;在满足系统安全约束的前提条件下,对系统进行模拟调度,重点评价了与发输电网络连接的VSC-HVDC对电网可靠性的影响,给出系统和节点的风险指标,为VSC-HVDC规划和运行提供参考依据,最后算例分析证明了该算法的可行性和合理性。