This work aims to understand the relationship between the member angle limit and the energy ratio for 24 test samples of composite beams and CFT square steel tube columns. This work also compares the formula applicabi...This work aims to understand the relationship between the member angle limit and the energy ratio for 24 test samples of composite beams and CFT square steel tube columns. This work also compares the formula applicability for member angle limit with the previous test result to provide the basic data for the design of composite beam-CFT column. The evaluation of the member angle limit was performed with concrete compressive strength (fC =22.16 MPa, 30.49 MPa), breadth-to-thickness ratio (B/t=25.0, 33.3, 43.5), and axial capacity ratio (N/N0=0, 0.3, 0.4, 0.5) as the main variables of the test samples. For the relationship between the member angle limit (Ru) and the energy ratio (ES/EC ), the test result shows that the energy ratio becomes lower as the axial capacity ratio and the breadth-to-thickness ratio increase. The energy ratio is lower for the Type B test sample compared with that of Types A and C. For the formula suggested by SATO, the test samples are distributed evenly for comparison between test values and the member angle limit; however, other formulas indicate a deviation. Specifically, for the comparison between R u,cal and R u (Test), Maeda's formula shows severe deviation.展开更多
To study the seismic behavior of high strength concrete fi lled double-tube(CFDT) columns,each consisting of an external square steel tube and an internal circular steel tube,quasi-static tests on eight CFDT column sp...To study the seismic behavior of high strength concrete fi lled double-tube(CFDT) columns,each consisting of an external square steel tube and an internal circular steel tube,quasi-static tests on eight CFDT column specimens were conducted.The test variables included the width-to-thickness ratio(β1) and the area ratio(β2) of the square steel tube,the wall thickness of the circular steel tube,and the axial force(or the axial force ratio) applied to the CFDT columns.The test results indicate that for CFDT columns with a square steel tube with β1 of 50.1 and 24.5,local buckling of the specimen was found at a drift ratio of 1/150 and 1/50,respectively.The lateral force-displacement hysteretic loops of all specimens were plump and stable.Reducing the width-to-thickness ratio of the square steel tube,increasing its area ratio,or increasing the wall thickness of the internal circular steel tube,led to an increased fl exural strength and deformation capacity of the specimens.Increasing the design value of the axial force ratio from 0.8 to 1.0 may increase the fl exural strength of the specimens,while it may also decrease the ultimate deformation capacity of the specimen with β1 of 50.1.展开更多
基金supported by the Basic Science Research Program of the National Research Foundation of Korea (NRF) and funded by the Ministry of Education,Science and Technology (2011-0009227)
文摘This work aims to understand the relationship between the member angle limit and the energy ratio for 24 test samples of composite beams and CFT square steel tube columns. This work also compares the formula applicability for member angle limit with the previous test result to provide the basic data for the design of composite beam-CFT column. The evaluation of the member angle limit was performed with concrete compressive strength (fC =22.16 MPa, 30.49 MPa), breadth-to-thickness ratio (B/t=25.0, 33.3, 43.5), and axial capacity ratio (N/N0=0, 0.3, 0.4, 0.5) as the main variables of the test samples. For the relationship between the member angle limit (Ru) and the energy ratio (ES/EC ), the test result shows that the energy ratio becomes lower as the axial capacity ratio and the breadth-to-thickness ratio increase. The energy ratio is lower for the Type B test sample compared with that of Types A and C. For the formula suggested by SATO, the test samples are distributed evenly for comparison between test values and the member angle limit; however, other formulas indicate a deviation. Specifically, for the comparison between R u,cal and R u (Test), Maeda's formula shows severe deviation.
基金the National Natural Science Foundation of China under Grants Nos.51261120377 and 51008173
文摘To study the seismic behavior of high strength concrete fi lled double-tube(CFDT) columns,each consisting of an external square steel tube and an internal circular steel tube,quasi-static tests on eight CFDT column specimens were conducted.The test variables included the width-to-thickness ratio(β1) and the area ratio(β2) of the square steel tube,the wall thickness of the circular steel tube,and the axial force(or the axial force ratio) applied to the CFDT columns.The test results indicate that for CFDT columns with a square steel tube with β1 of 50.1 and 24.5,local buckling of the specimen was found at a drift ratio of 1/150 and 1/50,respectively.The lateral force-displacement hysteretic loops of all specimens were plump and stable.Reducing the width-to-thickness ratio of the square steel tube,increasing its area ratio,or increasing the wall thickness of the internal circular steel tube,led to an increased fl exural strength and deformation capacity of the specimens.Increasing the design value of the axial force ratio from 0.8 to 1.0 may increase the fl exural strength of the specimens,while it may also decrease the ultimate deformation capacity of the specimen with β1 of 50.1.