期刊文献+
共找到52篇文章
< 1 2 3 >
每页显示 20 50 100
Numerical Simulation for Prediction of Wind Loads on Building Surfaces 被引量:1
1
作者 Zhang Xiaogang Institute of Applied Mechanics, Southwest Jiaotong University, Chengdu 610031, China 《Journal of Modern Transportation》 1997年第1期56-62,共7页
The reliability of the numerical K ε model for determining wind pressure on building surfaces is evaluated. The solution algorithm is based on a body fitted non orthogonal curvilinear coordinate system and a st... The reliability of the numerical K ε model for determining wind pressure on building surfaces is evaluated. The solution algorithm is based on a body fitted non orthogonal curvilinear coordinate system and a staggered grid arrangement. The covariant velocity components are chosen as dependent variables. Convective fluxes are described by the Power Law Scheme. The grids are generated with an elliptic grid generator using control functions. The results compare favorably with those by Oxford wind tunnel measurements. 展开更多
关键词 numerical simulation wind loads BUILDING
下载PDF
Grouping response method for equivalent static wind loads based on a modified LRC method 被引量:9
2
作者 Zhou Xuanyi Gu Ming Li Gang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2012年第1期107-119,共13页
Wind loading is one of the most important loads for controlling the design of large-span roof structures. Equivalent static wind loads, which can generally aim at determining a specific response, are widely used by st... Wind loading is one of the most important loads for controlling the design of large-span roof structures. Equivalent static wind loads, which can generally aim at determining a specific response, are widely used by structural designers. A method for equivalent static wind loads applicable to multi-responses is proposed in this paper. A modified load- response-correlation (LRC) method corresponding to a particular peak response is presented, and the similarity algorithm implemented for the group response is described. The main idea of the algorithm is that two responses can be put into one group if the value of one response is close to that of the other response, when the structure is subjected to equivalent static wind loads aiming at the other response. Based on the modified LRC, the grouping response method is put forward to construct equivalent static wind loading. This technique can simultaneously reproduce peak responses for some grouped responses. To verify its computational accuracy, the method is applied to an actual large-span roof structure. Calculation results show that when the similarity of responses in the same group is high, equivalent static wind loads with high accuracy and reasonable magnitude of equivalent static wind distribution can be achieved. 展开更多
关键词 large-span roof equivalent static wind loads modified LRC method grouping response similarityalgorithm
下载PDF
Study on semi-active control of mega-sub controlled structure by MR damper subject to random wind loads 被引量:7
3
作者 Qin Xiangjun Zhang Xun'an Sheldon Cherry 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2008年第3期285-294,共10页
The recently proposed mega-sub controlled structure (MSCS), a new type of structure associated with the design and construction of super-tall buildings, has attracted the attention of designers for use in enhancing ... The recently proposed mega-sub controlled structure (MSCS), a new type of structure associated with the design and construction of super-tall buildings, has attracted the attention of designers for use in enhancing the control effectiveness in mega-frame buildings. In this paper, a dynamic equation and method to assemble parameter matrixes for a mega-sub controlled structure under random wind loads is presented. Semi-active control using magnetorheological dampers for the MSCS under random wind loads is investigated, and is compared with a corresponding system without dampers. A parametric study of the relative stiffness ratio and relative mass ratio between the mega-frame and the substructures, as well as the additional column stiffness ratio that influences the response control effectiveness of the MSCS, is discussed. The studies reveal, for the first time, that different control mechanisms exist. The results indicate that the proposed structure employing semi-active control can offer an effective control mechanism. Guidelines for selecting parameters are provided based on the analytical study. 展开更多
关键词 mega-sub controlled structure (MSCS) semi-active control magnetorheological damper relative stiffness ratio relative mass ratio additional column stiffness ratio wind load
下载PDF
Effects of sudden change in wind loads on running performance of trains on a highway-railway one-story bridge in crosswinds 被引量:1
4
作者 HAN Yan LIU Ye +2 位作者 CAI Chun-sheng HU Peng HE Xu-hui 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第8期2621-2638,共18页
To investigate the effects of sudden change in wind loads on the running performance of trains on the bridge in crosswinds,a highway-railway one-story bridge was taken as the research object.Aerodynamic coefficients o... To investigate the effects of sudden change in wind loads on the running performance of trains on the bridge in crosswinds,a highway-railway one-story bridge was taken as the research object.Aerodynamic coefficients of the train and the bridge were measured in a series of train-bridge system segment models through wind tunnel tests when two trains passed each other on the bridge and when a train entered and left the wind barrier section of the bridge.Based on the improved SIMPACK and ANSYS rigid-flexible coupling simulation method,a wind-double train-track-bridge system coupled vibration model was established.The dynamic responses of the train were analyzed under the effects of sudden change in wind loads caused by two trains passing each other and a train entering and leaving the wind barrier section of the bridge.The results show that the effects of sudden wind load change caused by the trains passing each other had less effects on the running safety of the leeward-side train than the wind shielding effect caused by the windward-side train in the wind speed range of 10−25 m/s.With the decrease in the porosity of wind barriers,the effects of the sudden wind load change played an increasingly important role in the running safety and comfort of the train.With the increase in wind speed,the lateral response of the train increased obviously because of the effects of sudden wind load change,which affects both the lateral running stability and the comfort of the train. 展开更多
关键词 wind-train-track-bridge system two trains passing each other wind barrier sudden change in wind load dynamic response
下载PDF
Measurements of Wind Loads on Side-by-Side Semi-Submersibles in A Wind Tunnel 被引量:1
5
作者 DONG Qing GUO Xiao-xian +2 位作者 YANG Jian-min LU Hai-ning HUANG Longwei 《China Ocean Engineering》 SCIE EI CSCD 2021年第4期531-543,共13页
The multi-body system has been a popular form for offshore operations in terms of high efficiency.The wind effects are crucial which directly affect the relative positions of floating bodies and operating security.In ... The multi-body system has been a popular form for offshore operations in terms of high efficiency.The wind effects are crucial which directly affect the relative positions of floating bodies and operating security.In this study,the aerodynamic characteristics for two coupled semi-submersibles were analyzed in a wind tunnel to fill the gaps in literature related to the wind sheltering on offshore platforms.The influences of separation distance were also investigated.According to the results,substantial shielding effects were observed and wind forces on the shielded vessel decreased dramatically:a reduction in the transverse force could be up to 74%.Moreover,the longitudinal wind load was amplified by the platform abreast in a side-by-side configuration.As expected,the interference level became more pronounced with a decreasing separation distance.For cases in which wind interaction decayed rapidly with distance,logarithmic functions were preferable for describing the relationship between them.Whereas linear fitting was reasonable for the transverse wind force when there was still evident sheltering at a quite large distance.The length of shielding area was another important factor that there was approximately a linear relationship between it and the shielding level for two platforms in close proximity at various wind attack angles.Based on the two parameters,a preliminary wind loads estimation method considering shielding effects was proposed.This approach can aid the industry to have a qualitative assessment of wind sheltering especially at early stages. 展开更多
关键词 wind loads side-by-side shielding effect wind tunnel test
下载PDF
A Review of the Calculation Methods of Lifting Capacity in Wind Loads on Ocean Platforms
6
作者 Yuchen Sheng 《Open Journal of Marine Science》 2021年第2期69-79,共11页
Wind load is a control load that affects the safety of structures in the design of ocean platforms. It has not only direct and powerful effects that may cause structure resonance but also has indirect effects causing ... Wind load is a control load that affects the safety of structures in the design of ocean platforms. It has not only direct and powerful effects that may cause structure resonance but also has indirect effects causing waves or currents in the ocean. By analyzing the domestic and international norms, this study <span style="letter-spacing:0.1pt;font-family:Verdana;font-size:12px;">pre</span><span style="font-family:Verdana;font-size:12px;">sents a review of calculation methods of wind load on ocean platforms, which </span><span style="letter-spacing:-0.15pt;font-family:Verdana;font-size:12px;">belongs to large-scale non-entity structure used in the open sea while sur</span><span style="font-family:Verdana;font-size:12px;">round</span><span style="letter-spacing:-0.1pt;font-family:Verdana;font-size:12px;">ing wind has no fixed direction. Current computations according to the</span><span style="font-family:Verdana;font-size:12px;"> norms are not accurate, which even not takes the force of the wind against the surf</span><span style="letter-spacing:-0.1pt;font-family:Verdana;font-size:12px;">ace perpendicular to the structure into consideration. Additionally, thi</span><span style="font-family:Verdana;font-size:12px;">s study also introduces and compares the lift model of platforms based on different </span><span style="letter-spacing:-0.1pt;font-family:Verdana;font-size:12px;">theories, such as vortex-excitation and vibration, engineering structure dy</span><span style="font-family:Verdana;font-size:12px;">namics, gas flow pressure theory, analyzing their applicability, advantages, and disadvantages. This paper analyzes the limitations and applicable conditions of the existing calculation method itself, such as the lift model is suitable for the existence of stable vortex wake;the calculation method of the structural dynamics of marine engineering must be combined with the wind tunnel test and consider the mistakes caused by the position relationship;the numerical simulation method is accurate but tedious. This study provides an insight into the calculation methods of lift in designing ocean platforms, including the </span><span style="letter-spacing:0.1pt;font-family:Verdana;font-size:12px;">finite element method for simulating fluid force and updating formulas in</span><span style="font-family:Verdana;font-size:12px;"> Chinese norms.</span> 展开更多
关键词 LIFT wind Load Calculation Method Lift Model Structural Dynamics Vortex-Excitation
下载PDF
Autogeneration of Wind Loads on Buildings
7
作者 Qin Xiaolin Lu Zhanqin (Structural Engineering Research Instilule,Southwest Jiaolong Universily,Chengdu 610031,China) 《Journal of Modern Transportation》 1995年第2期117-126,共10页
in desisncede, some design knowledse about wind load on buildinss, i. e. ,wind load coefficient of building shape μs, is diasraniniatically prescribed.Wind pressure on a building surface partly depends on the shapo o... in desisncede, some design knowledse about wind load on buildinss, i. e. ,wind load coefficient of building shape μs, is diasraniniatically prescribed.Wind pressure on a building surface partly depends on the shapo of the surfaceand the dimension of the building. This part of desisn knowledge can not bedirectly used in CAD systems.It must be prucesaed in order to autogenerate thewind load on a building for the niechanical analysis of the building structure.The article presents the formalization of design knowledge about wind load onbuildings. A mathematical model for the plane seonietrical contour of buildingstructure is established. The map relationship between the shape, dimension ofbuilding and wind load coefficient of building shape is numerically depicted.Therefore, the autogeneration of wind load on building structure isaccomplished. The data structure and algorithm related to the accomplishmentare also described in details. 展开更多
关键词 wind load building shape formalization
下载PDF
Kriging metamodels for the dynamic response of high-rise buildings with outrigger systems and fragility estimates for seismic and wind loads
8
作者 Lili Xing Paolo Gardoni Ying Zhou 《Resilient Cities and Structures》 2022年第1期110-122,共13页
This paper proposes kriging metamodels for the dynamic response of high-rise buildings with outrigger systems subject to seismic and wind loads.Three types of outrigger systems are considered.Three-dimensional(3D)fini... This paper proposes kriging metamodels for the dynamic response of high-rise buildings with outrigger systems subject to seismic and wind loads.Three types of outrigger systems are considered.Three-dimensional(3D)finite element models of high-rise buildings with outrigger systems are developed using ANSYS.Data generated from the finite element models are used to develop the proposed kriging metamodels.A sensitivity analysis is then carried out to determine the most sensitive input parameters in kriging metamodels to gain insights and suggest possible future developments.The proposed kriging metamodels are used to develop fragility estimates for high-rise buildings with three types of outrigger systems under seismic and wind loads. 展开更多
关键词 Kriging metamodel Sensitivity analysis Fragility estimate Outrigger systems Seismic and wind loads
下载PDF
Contribution of tuned liquid column gas dampers to the performance of offshore wind turbines under wind, wave, and seismic excitations 被引量:8
9
作者 Khosrow Bargi Reza Dezvareh Seyed Amin Mousavi 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2016年第3期551-561,共11页
The main intention of the present study is to reduce wind, wave, and seismic induced vibrations of jacket- type offshore wind turbines (JOWTs) through a newly developed vibration absorber, called tuned liquid column... The main intention of the present study is to reduce wind, wave, and seismic induced vibrations of jacket- type offshore wind turbines (JOWTs) through a newly developed vibration absorber, called tuned liquid column gas damper (TLCGD). Using a Simulink-based model, an analytical model is developed to simulate global behavior of JOWTs under different dynamic excitations. The study is followed by a parametric study to explore efficiency of the TLCGD in terms of nacelle acceleration reduction under wind, wave, and earthquake loads. Study results indicate that optimum frequency of the TLCGD is rather insensitive to excitation type. In addition, while the gain in vibration control from TLCGDs with higher mass ratios is generally more pronounced, heavy TLCGDs are more sensitive to their tuned frequency such that ill-regulated TLCGD with high mass ratio can lead to destructive results. It is revealed that a well regulated TLCGD has noticeable contribution to the dynamic response of the JOWT under any excitation. 展开更多
关键词 offshore wind turbine wind load wave load seismic load tuned liquid column gas damper
下载PDF
Application of artificial neural networks in optimal tuning of tuned mass dampers implemented in high-rise buildings subjected to wind load 被引量:8
10
作者 Meysam Ramezani Akbar Bathaei Amir K.Ghorbani-Tanha 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2018年第4期903-915,共13页
High-rise buildings are usually considered as flexible structures with low inherent damping. Therefore, these kinds of buildings are susceptible to wind-induced vibration. Tuned Mass Damper(TMD) can be used as an ef... High-rise buildings are usually considered as flexible structures with low inherent damping. Therefore, these kinds of buildings are susceptible to wind-induced vibration. Tuned Mass Damper(TMD) can be used as an effective device to mitigate excessive vibrations. In this study, Artificial Neural Networks is used to find optimal mechanical properties of TMD for high-rise buildings subjected to wind load. The patterns obtained from structural analysis of different multi degree of freedom(MDF) systems are used for training neural networks. In order to obtain these patterns, structural models of some systems with 10 to 80 degrees-of-freedoms are built in MATLAB/SIMULINK program. Finally, the optimal properties of TMD are determined based on the objective of maximum displacement response reduction. The Auto-Regressive model is used to simulate the wind load. In this way, the uncertainties related to wind loading can be taken into account in neural network’s outputs. After training the neural network, it becomes possible to set the frequency and TMD mass ratio as inputs and get the optimal TMD frequency and damping ratio as outputs. As a case study, a benchmark 76-story office building is considered and the presented procedure is used to obtain optimal characteristics of the TMD for the building. 展开更多
关键词 artificial neural networks tuned mass damper wind load auto-regressive model optimal frequency anddamping
下载PDF
Concept Design and Coupled Dynamic Response Analysis on 6-MW Spar-Type Floating Offshore Wind Turbine 被引量:6
11
作者 MENG Long ZHOU Tao +2 位作者 HE Yan-ping ZHAO Yong-sheng LIU Ya-dong 《China Ocean Engineering》 SCIE EI CSCD 2017年第5期567-577,共11页
Tower, Spar platform and mooring system are designed in the project based on a given 6-MW wind turbine. Under wind-induced only, wave-induced only and combined wind and wave induced loads, dynamic response is analyzed... Tower, Spar platform and mooring system are designed in the project based on a given 6-MW wind turbine. Under wind-induced only, wave-induced only and combined wind and wave induced loads, dynamic response is analyzed for a 6-MW Spar-type floating offshore wind turbine (FOWT) under operating conditions and parked conditions respectively. Comparison with a platform-fixed system (land-based system) ofa 6-MW wind turbine is carried out as well. Results demonstrate that the maximal out-of-plane deflection of the blade of a Spar-type system is 3.1% larger than that of a land-based system; the maximum response value of the nacelle acceleration is 215% larger for all the designed load cases being considered; the ultimate tower base fore-aft bending moment of the Spar-type system is 92% larger than that of the land-based system in all of the Design Load Cases (DLCs) being considered; the fluctuations of the mooring tension is mainly wave-induced, and the safety factor of the mooring tension is adequate for the 6-MW FOWT. The results can provide relevant modifications to the initial design for the Spar-type system, the detailed design and model basin test of the 6-MW Spar-type system. 展开更多
关键词 Spar-type floating offshore wind turbine concept design combined wind and wave loads coupled dynamicresponse
下载PDF
A new framework for evaluating along-wind responses of a transmission tower 被引量:3
12
作者 Liu Guohuan and Li Hongnan School of Civil and Hydraulic Engineering, Dalian University of Technology, Dalian 116023, China PhD Professor 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2009年第1期87-93,共7页
In this paper, an analytical framework to evaluate the along-wind-induced dynamic responses of a transmission tower is presented. Two analytical models and a new method are developed: (1) a higher mode generalized ... In this paper, an analytical framework to evaluate the along-wind-induced dynamic responses of a transmission tower is presented. Two analytical models and a new method are developed: (1) a higher mode generalized force spectrum (GFS) model of the transmission tower is deduced; (2) an analytical model that includes the contributions of the higher modes is further derived as a rational algebraic formula to estimate the structural displacement response; and (3) a new approach, applying load with displacement (ALD) instead of force, to solve the internal force of transmission tower is given. Unlike conventional methods, the ALD method can avoid calculating equivalent static wind loads (ESWLs). Finally, a transmission tower structure is used as a numerical example to verify the feasibility and accuracy of the ALD method. 展开更多
关键词 along-wind-induced dynamic responses transmission tower generalized force spectrum equivalent static wind loads
下载PDF
PATH INTEGRAL SOLUTION OF NONLINEAR DYNAMIC BEHAVIOR OF STRUCTURE UNDER WIND EXCITATION 被引量:1
13
作者 王仲刚 程华 邓洪洲 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2005年第10期1303-1311,共9页
A numerical scheme for the nonlinear behavior of structure under wind excitation is investigated. With the white noise filter of turbulent-wind fluctuations, the nonlinear motion equation of structures subjected to wi... A numerical scheme for the nonlinear behavior of structure under wind excitation is investigated. With the white noise filter of turbulent-wind fluctuations, the nonlinear motion equation of structures subjected to wind load was modeled as the Ito' s stochastic differential equation. The state vector associated with such a model is a diffusion process. A continuous linearization strategy in the time-domain was adopted. Based on the solution series of its stochastic linearization equations, the formal probabilistic density of the structure response was developed by the path integral technique. It is shown by the numerical example of a guyed mast that compared with the frequency-domain method and the time-domain nonlinear analysis, the proposed approach is highlighted by high accuracy and effectiveness. The influence of the structure non-linearity on the dynamic reliability assessment is also analyzed in the example. 展开更多
关键词 NONLINEAR dynamic response wind load path integral solution white noise joint statistical distribution
下载PDF
PROBABILITY MODEL AND SOLUTION ON EARTHQUAKE EFFECTS COMBINATION IN ALONG WIND RESISTANT DESIGN OF TALL-FLEXIBLE BUILDINGS 被引量:1
14
作者 洪小健 顾明 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2006年第5期627-636,共10页
A model on the earthquake effects combination in wind resistant design of high-rise flexible structures is proposed in accordance with the probability method. Based on the Turkstra criteria, the stochastic characters ... A model on the earthquake effects combination in wind resistant design of high-rise flexible structures is proposed in accordance with the probability method. Based on the Turkstra criteria, the stochastic characters of wind velocity, earthquake ground acceleration and excitations occurrence probability are taken into account and then the combination of the earthquake effects in structure wind resistant design is analyzed with the convolution approach. The results indicate that as for the tall flexible buildings whose lateral force is governed by wind loading, the maximum lateral loads verification with respect to the wind resistant design combined with earthquake effects may be more unfavorable compared with that in terms of the earthquake resistant design involving wind effects. 展开更多
关键词 high-rise structure wind loading earthquake effects COMBINATION Turkstra criteria
下载PDF
Study on longitudinal wind load calculation method of cables for cable-stayed bridge 被引量:2
15
作者 Pei Minshan Zhang Xigang Zhu Bin Hou Bin Liu Changpeng 《Engineering Sciences》 EI 2009年第1期18-22,58,共6页
Along with the expanding of span of cable-stayed bridge,wind load becomes a more and more important controlling factor for bridge the design.A very large proportion of the wind load acting on cables has exceeded that ... Along with the expanding of span of cable-stayed bridge,wind load becomes a more and more important controlling factor for bridge the design.A very large proportion of the wind load acting on cables has exceeded that acting on deck.There was not any detailed prescript in Chinese code for calculation of longitudinal wind load on cables due to lack of theoretical research and experiment,and conservative simplified calculation was adopted during design,which leads to conservative and uneconomical design of structures.To resolve this problem,cable force experiment was carried out during the design of Sutong Bridge.By comparing with international research results,the calculation formula of longitudinal wind drag coefficient for cables was advanced to fill the blank of bridge wind resistant code of China,and has already been adopted in the Highway Bridge Wind Resistant Design Code(JTG/T D60-01-2004)with great significance for bridge engineering. 展开更多
关键词 cable-stayed bridge stayed cable longitudinal wind load
下载PDF
Determination method of load balance ranges for train operation safety under strong wind 被引量:3
16
作者 田红旗 《Journal of Central South University》 SCIE EI CAS CSCD 2015年第3期1146-1154,共9页
The aerodynamic performances of a passenger car and a box car with different heights of windbreak walls under strong wind were studied using the numerical simulations, and the changes of aerodynamic side force, lift f... The aerodynamic performances of a passenger car and a box car with different heights of windbreak walls under strong wind were studied using the numerical simulations, and the changes of aerodynamic side force, lift force and overturning moment with different wind speeds and wall heights were calculated. According to the principle of static moment balance of vehicles, the overturning coefficients of trains with different wind speeds and wall heights were obtained. Based on the influence of wind speed and wall height on the aerodynamic performance and the overturning stability of trains, a method of determination of the load balance ranges for the train operation safety was proposed, which made the overturning coefficient have nearly closed interval. A min(|A1|+|A2|), s.t. |A1|→|A2|(A1 refers to the downwind overturning coefficient and A2 refers to the upwind overturning coefficient)was found. This minimum value helps to lower the wall height as much as possible, and meanwhile, guarantees the operation safety of various types of trains under strong wind. This method has been used for the construction and improvement of the windbreak walls along the Lanzhou–Xinjiang railway(from Lanzhou to Urumqi, China). 展开更多
关键词 strong wind train load balance range overturning coefficient aerodynamic performance
下载PDF
On Advanced Control Methods toward Power Capture and Load Mitigation in Wind Turbines 被引量:2
17
作者 Yuan Yuan Jiong Tang 《Engineering》 SCIE EI 2017年第4期494-503,共10页
This article provides a survey of recently emerged methods for wind turbine control. Multivariate control approaches to the optimization of power capture and the reduction of loads in components under time-varying tur... This article provides a survey of recently emerged methods for wind turbine control. Multivariate control approaches to the optimization of power capture and the reduction of loads in components under time-varying turbulent wind fields have been under extensive investigation in recent years. We divide the related research activities into three categories: modeling and dynamics of wind turbines, active control of wind turbines, and passive control of wind turbines. Regarding turbine dynamics, we discuss the physical fundamentals and present the aeroelastic analysis tools. Regarding active control, we review pitch control, torque control, and yaw control strategies encompassing mathematical formulations as well as their applications toward different objectives. Our survey mostly focuses on blade pitch control, which is considered one of the key elements in facilitating load reduction while maintaining power capture performance. Regarding passive control, we review techniques such as tuned mass dampers, smart rotors, and microtabs. Possible future directions are suggested. 展开更多
关键词 wind turbine Control approach Power optimization Load mitigation
下载PDF
Fracture Analysis for Torsion Problems of a Gravity Platform Column with Cracks Under Wind Load
18
作者 PAN Tianwei WANG Yinbang ZHOU Liqin 《Journal of Ocean University of China》 SCIE CAS 2010年第1期37-42,共6页
Ocean platforms are subjected to a variety of environment loads, such as those from winds, waves, currents, etc. In this study, the torsion problems of a gravity platform column with cracks under wind load were invest... Ocean platforms are subjected to a variety of environment loads, such as those from winds, waves, currents, etc. In this study, the torsion problems of a gravity platform column with cracks under wind load were investigated. The colmnn was assumed to be a composite cylinder. Therefore the torsion fracture problem of a composite cylinder was considered, and new boundary integral equations for the Saint-Venant torsion problem of a composite cylinder with curvilinear cracks were derived. The problem was re- duced to solving the boundary integral equations on every boundary. By using the new boundary element method, the torsion prob- lem of the gravity platform colunm with a straight crack under various wind loads was calculated. The obtained results were com- pared with those obtained for a torsion problem of the same column without cracks to prove the applicability of the present method. The comparison showed that the detrimental effect of cracks in a column should be considered in marine engineering. 展开更多
关键词 wind load gravity platform COLUMN composite cylinder torsion fracture boundary integral equation
下载PDF
Discussion on Key Points of Wind Load of Jack-up Unit
19
作者 林一 胡安康 +1 位作者 熊飞 蒋玮 《China Ocean Engineering》 SCIE EI CSCD 2014年第1期127-138,共12页
The anti-overturning ability and structure safety of jack-up unit in in-place condition are often affected by environment loads, especially wind load. According to the MODU rule, the projected area method is used for ... The anti-overturning ability and structure safety of jack-up unit in in-place condition are often affected by environment loads, especially wind load. According to the MODU rule, the projected area method is used for calculating the wind load. However, the calculated results are conservative and not good for structure optimization design. In this paper, a 400 ft jack-up is studied as an example. Based on the wind tunnel test and numerical simulation method, some key points of wind load calculation, such as shielding effect, lift effect and shape coefficient of component, are discussed. The study shows that the points mentioned above, which are ignored in the MODU rule calculation, result in the conservative result. 展开更多
关键词 jack-up unit wind load shielding effect lift effect shape coefficient
下载PDF
General Expression of LRC Method in Estimation of Bridge’s Equivalent Static Wind Load
20
作者 Rui Dong Yaojun Ge +1 位作者 Lin Zhao Jiangang Wei 《Journal of Harbin Institute of Technology(New Series)》 CAS 2021年第3期28-44,共17页
According to the relationship between load and response, the equivalent static wind load(ESWL) of a structure can be estimated by load-response correlation(LRC) method, which can be accurately used to estimate the bac... According to the relationship between load and response, the equivalent static wind load(ESWL) of a structure can be estimated by load-response correlation(LRC) method, which can be accurately used to estimate the background ESWL of a structure. The derivation of the classical expression of LRC formula is based on a specific command response at a critical position, and the ESWL distribution has only one form in this case. In this paper, a general expression of LRC formula is derived based on a specific command response at all positions. For the general expression, ESWLs can be expressed by load-response correlation coefficients, response-response correlation coefficients, RMS values of the fluctuating wind loads, and peak factor in the form of matrices. By comparing the expressions of LRC method, it was found that the classical expression was only one form of the general one. The general expression which introduces the response-response correlation coefficients provided more options for structural engineers to estimate ESWLs and offered further insights into the LRC method. Finally, a cable-stayed bridge, a rigid three span continuous girder bridge, and a suspension bridge were used to verify the correctness of the general expression of LRC method. 展开更多
关键词 BRIDGES equivalent static wind load load-response correlation method background response general expression load-response correlation coefficient response-response correlation coefficient
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部