In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. T...In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on H-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response.展开更多
This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-...This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-phase inverter circuits,continues by discussing the control strategy for grid-connected single-phase inverter circuits,realizes a sinusoidal pulse width modulation(SPWM)signal generation circuit and an inverse control algorithm program,and finally ensures good output waveform and fast dynamic response.In view of the hysteresis feature of the grid voltage’s synchronous signal sampling circuit,the acquisition function in digital signal processing(DSP)control chips is applied,and the reasons for the hysteresis phenomenon are thoroughly investigated.The reliability of the SPWM control algorithm is revealed through the results.展开更多
Since the connection of small-scale wind farms to distribution networks,power grid voltage stability has been reduced with increasing wind penetration in recent years,owing to the variable reactive power consumption o...Since the connection of small-scale wind farms to distribution networks,power grid voltage stability has been reduced with increasing wind penetration in recent years,owing to the variable reactive power consumption of wind generators.In this study,a two-stage reactive power optimization method based on the alternating direction method of multipliers(ADMM)algorithm is proposed for achieving optimal reactive power dispatch in wind farm-integrated distribution systems.Unlike existing optimal reactive power control methods,the proposed method enables distributed reactive power flow optimization with a two-stage optimization structure.Furthermore,under the partition concept,the consensus protocol is not needed to solve the optimization problems.In this method,the influence of the wake effect of each wind turbine is also considered in the control design.Simulation results for a mid-voltage distribution system based on MATLAB verified the effectiveness of the proposed method.展开更多
This paper introduces a novel single-phase asymmetrical multilevel inverter suitable for hybrid renewable energy sources. The proposed inverter consists of two isolated DC sources and six power semiconductor controlle...This paper introduces a novel single-phase asymmetrical multilevel inverter suitable for hybrid renewable energy sources. The proposed inverter consists of two isolated DC sources and six power semiconductor controlled switches. The suggested inverter is capable of generating seven-level output when the input DC voltage is taken in the ratio of 1:2. The higher magnitude DC source is fed from Photo Voltaic (PV) panels, whereas the lower magnitude DC source is fed from Wind Turbine (WT) driven Permanent Magnet DC (PMDC) generator. Both the renewable energy sources are connected to the inverter via two DC-DC boost converters connected in cascade (i.e. one for maximum power point tracking and another for DC-link voltage control). The proposed hybrid renewable energy source inverter is connected to single-phase grid via proper control systems. The complete system is simulated using MATLAB/SIMULINK and the results are presented in detail.展开更多
Since only one inverter voltage vector is applied during each duty cycle, traditional model predictive direct power control(MPDPC) for grid-connected inverters(GCIs) results in serious harmonics in current and power. ...Since only one inverter voltage vector is applied during each duty cycle, traditional model predictive direct power control(MPDPC) for grid-connected inverters(GCIs) results in serious harmonics in current and power. Moreover, a high sampling frequency is needed to ensure satisfactory steady-state performance, which is contradictory to its long execution time due to the iterative prediction calculations. To solve these problems, a novel dead-beat MPDPC strategy is proposed, using two active inverter voltage vectors and one zero inverter voltage vector during each duty cycle. Adoption of three inverter vectors ensures a constant switching frequency. Thus, smooth steady-state performance of both current and power can be obtained. Unlike the traditional three-vector based MPDPC strategy, the proposed three vectors are selected based on the power errors rather than the sector where the grid voltage vector is located, which ensures that the duration times of the selected vectors are positive all the time. Iterative calculations of the cost function in traditional predictive control are also removed, which makes the proposed strategy easy to implement on digital signal processors(DSPs) for industrial applications. Results of experiments based on a 1 kW inverter setup validate the feasibility of the proposed three-vector based dead-beat MPDPC strategy.展开更多
Proportion resonant(PR)controllers are able to achieve zero steady-state error for AC input signals and are widely used for simplifying control systems in the stationary reference frame.However,power decoupling in the...Proportion resonant(PR)controllers are able to achieve zero steady-state error for AC input signals and are widely used for simplifying control systems in the stationary reference frame.However,power decoupling in the stationary reference frame with a PR controller has not been investigated thoroughly.Based on the complex vector model of a grid-connected inverter(GCI),this paper deduces theoretically the power coupling relationship of GCI with the traditional PR current controller.A modified PR controller is provided for achieving the power decoupling,and the design method of the controller is presented.Simulation and experimental results verify that there is coupling between active and reactive power using the traditional PR controller and the proposed method can realize the power decoupling.展开更多
This paper focuses on the wind energy conversion system (WECS) with the three main electrical aspects: 1) wind turbine generators (WTGs), 2) power electronics converters (PECs) and 3) grid-connection issues. The curre...This paper focuses on the wind energy conversion system (WECS) with the three main electrical aspects: 1) wind turbine generators (WTGs), 2) power electronics converters (PECs) and 3) grid-connection issues. The current state of wind turbine generators are discussed and compared in some criteria along with the trends in the current WECS market, which are ‘Variable Speed’, ‘Multi-MW’ and ‘Offshore’. In addition, the other crucial component in the WECS, PECs will be discussed with its topologies available in the current WECS market along with their modulation strategies. Moreover, three main issues of the WECS associating with the grid-connection, fault-ride through (FRT) capability, harmonics/interharmonics emission and flicker, which are the power quality issues, will be discussed due to the increasing responsibility of WECS as utility power station. Some key findings from the review such as the attractiveness of BDFRG are presented in the conclusion of this paper.展开更多
Finite control set-model predictive control (FCS-MPC) is employed in this paper to control the operation of a three-phase grid-connected string inverter based on a direct PQ control scheme. The main objective is to ac...Finite control set-model predictive control (FCS-MPC) is employed in this paper to control the operation of a three-phase grid-connected string inverter based on a direct PQ control scheme. The main objective is to achieve high-performance decoupled control of the active and reactive powers injected to the grid from distributed energy resources (DER).The FCS-MPC scheme instantaneously searches for and applies the optimum inverter switching state that can achieve certain goals, such as minimum deviation between reference and actual power;so that both power components (P and Q) are well controlled to their reference values.In addition, an effective method to attenuate undesired cross coupling between the P and Q control loops, which occurs only during transient operation, is investigated. The proposed method is based on the variation of the weight factors of the terms of the FCS-MPC cost function, so a higher weight factor is assigned to the cost function term that is exposed to greater disturbance. Empirical formulae of optimum weight factors as functions of the reference active and reactive power signals are proposed and mathematically derived. The investigated FCS-MPC control scheme is incorporated with the LVRT function to support the grid voltage in fulfilling and accomplishing the up-to-date grid codes. The LVRT algorithm is based on a modification of the references of active and reactive powers as functions of the instantaneous grid voltage such that suitable values of P and Q are injected to the grid during voltage sag.The performance of the elaborated FCS-MPC PQ scheme is studied under various operating scenarios, including steady-state and transient conditions. Results demonstrate the validity and effectiveness of the proposed scheme with regard to the achievement of high-performance operation and quick response of grid-tied inverters during normal and fault modes.展开更多
Because of system constraints caused by the external environment and grid faults,the conventional maximum power point tracking(MPPT)and inverter control methods of a PV power generation system cannot achieve optimal p...Because of system constraints caused by the external environment and grid faults,the conventional maximum power point tracking(MPPT)and inverter control methods of a PV power generation system cannot achieve optimal power output.They can also lead to misjudgments and poor dynamic performance.To address these issues,this paper proposes a new MPPT method of PV modules based on model predictive control(MPC)and a finite control set model predictive current control(FCS-MPCC)of an inverter.Using the identification model of PV arrays,the module-based MPC controller is designed,and maximum output power is achieved by coordinating the optimal combination of spectral wavelength and module temperature.An FCS-MPCC algorithm is then designed to predict the inverter current under different voltage vectors,the optimal voltage vector is selected according to the optimal value function,and the corresponding optimal switching state is applied to power semiconductor devices of the inverter.The MPPT performance of the MPC controller and the responses of the inverter under different constraints are verified,and the steady-state and dynamic control effects of the inverter using FCS-MPCC are compared with the traditional feedforward decoupling PI control in Matlab/Simulink.The results show that MPC has better tracking performance under constraints,and the system has faster and more accurate dynamic response and flexibility than conventional PI control.展开更多
Herein,a novel wind power grid-connection system based on inductive filtering is proposed to improve grid-connection compatibility,and is implemented in a 50-MW real system.First,the topology and wiring configuration ...Herein,a novel wind power grid-connection system based on inductive filtering is proposed to improve grid-connection compatibility,and is implemented in a 50-MW real system.First,the topology and wiring configuration of the proposed system are discussed.Thereafter,an equivalent circuit and mathematical model are established to reveal the filtering characteristics and resonance damping mechanism of the proposed system.Finally,a 50-MW wind farm-based experimental study,which is conducted to validate the effectiveness and availability of the system is discussed.The experimental results show that the main harmonics,power factor,voltage fluctuation,and flicker satisfy national standards.展开更多
基金supported by Delta Power Electronic Science and Education Development in 2007 (Grant No.DRES2007002)
文摘In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on H-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response.
文摘This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-phase inverter circuits,continues by discussing the control strategy for grid-connected single-phase inverter circuits,realizes a sinusoidal pulse width modulation(SPWM)signal generation circuit and an inverse control algorithm program,and finally ensures good output waveform and fast dynamic response.In view of the hysteresis feature of the grid voltage’s synchronous signal sampling circuit,the acquisition function in digital signal processing(DSP)control chips is applied,and the reasons for the hysteresis phenomenon are thoroughly investigated.The reliability of the SPWM control algorithm is revealed through the results.
基金support of The National Key Research and Development Program of China(Basic Research Class)(No.2017YFB0903000)the National Natural Science Foundation of China(No.U1909201)。
文摘Since the connection of small-scale wind farms to distribution networks,power grid voltage stability has been reduced with increasing wind penetration in recent years,owing to the variable reactive power consumption of wind generators.In this study,a two-stage reactive power optimization method based on the alternating direction method of multipliers(ADMM)algorithm is proposed for achieving optimal reactive power dispatch in wind farm-integrated distribution systems.Unlike existing optimal reactive power control methods,the proposed method enables distributed reactive power flow optimization with a two-stage optimization structure.Furthermore,under the partition concept,the consensus protocol is not needed to solve the optimization problems.In this method,the influence of the wake effect of each wind turbine is also considered in the control design.Simulation results for a mid-voltage distribution system based on MATLAB verified the effectiveness of the proposed method.
文摘This paper introduces a novel single-phase asymmetrical multilevel inverter suitable for hybrid renewable energy sources. The proposed inverter consists of two isolated DC sources and six power semiconductor controlled switches. The suggested inverter is capable of generating seven-level output when the input DC voltage is taken in the ratio of 1:2. The higher magnitude DC source is fed from Photo Voltaic (PV) panels, whereas the lower magnitude DC source is fed from Wind Turbine (WT) driven Permanent Magnet DC (PMDC) generator. Both the renewable energy sources are connected to the inverter via two DC-DC boost converters connected in cascade (i.e. one for maximum power point tracking and another for DC-link voltage control). The proposed hybrid renewable energy source inverter is connected to single-phase grid via proper control systems. The complete system is simulated using MATLAB/SIMULINK and the results are presented in detail.
基金supported by the National Natural Science Foundation of China(No.51622706)the Fundamental Research Funds for the Central Universities,China(No.2017XZZX002-17)
文摘Since only one inverter voltage vector is applied during each duty cycle, traditional model predictive direct power control(MPDPC) for grid-connected inverters(GCIs) results in serious harmonics in current and power. Moreover, a high sampling frequency is needed to ensure satisfactory steady-state performance, which is contradictory to its long execution time due to the iterative prediction calculations. To solve these problems, a novel dead-beat MPDPC strategy is proposed, using two active inverter voltage vectors and one zero inverter voltage vector during each duty cycle. Adoption of three inverter vectors ensures a constant switching frequency. Thus, smooth steady-state performance of both current and power can be obtained. Unlike the traditional three-vector based MPDPC strategy, the proposed three vectors are selected based on the power errors rather than the sector where the grid voltage vector is located, which ensures that the duration times of the selected vectors are positive all the time. Iterative calculations of the cost function in traditional predictive control are also removed, which makes the proposed strategy easy to implement on digital signal processors(DSPs) for industrial applications. Results of experiments based on a 1 kW inverter setup validate the feasibility of the proposed three-vector based dead-beat MPDPC strategy.
文摘Proportion resonant(PR)controllers are able to achieve zero steady-state error for AC input signals and are widely used for simplifying control systems in the stationary reference frame.However,power decoupling in the stationary reference frame with a PR controller has not been investigated thoroughly.Based on the complex vector model of a grid-connected inverter(GCI),this paper deduces theoretically the power coupling relationship of GCI with the traditional PR current controller.A modified PR controller is provided for achieving the power decoupling,and the design method of the controller is presented.Simulation and experimental results verify that there is coupling between active and reactive power using the traditional PR controller and the proposed method can realize the power decoupling.
文摘This paper focuses on the wind energy conversion system (WECS) with the three main electrical aspects: 1) wind turbine generators (WTGs), 2) power electronics converters (PECs) and 3) grid-connection issues. The current state of wind turbine generators are discussed and compared in some criteria along with the trends in the current WECS market, which are ‘Variable Speed’, ‘Multi-MW’ and ‘Offshore’. In addition, the other crucial component in the WECS, PECs will be discussed with its topologies available in the current WECS market along with their modulation strategies. Moreover, three main issues of the WECS associating with the grid-connection, fault-ride through (FRT) capability, harmonics/interharmonics emission and flicker, which are the power quality issues, will be discussed due to the increasing responsibility of WECS as utility power station. Some key findings from the review such as the attractiveness of BDFRG are presented in the conclusion of this paper.
文摘Finite control set-model predictive control (FCS-MPC) is employed in this paper to control the operation of a three-phase grid-connected string inverter based on a direct PQ control scheme. The main objective is to achieve high-performance decoupled control of the active and reactive powers injected to the grid from distributed energy resources (DER).The FCS-MPC scheme instantaneously searches for and applies the optimum inverter switching state that can achieve certain goals, such as minimum deviation between reference and actual power;so that both power components (P and Q) are well controlled to their reference values.In addition, an effective method to attenuate undesired cross coupling between the P and Q control loops, which occurs only during transient operation, is investigated. The proposed method is based on the variation of the weight factors of the terms of the FCS-MPC cost function, so a higher weight factor is assigned to the cost function term that is exposed to greater disturbance. Empirical formulae of optimum weight factors as functions of the reference active and reactive power signals are proposed and mathematically derived. The investigated FCS-MPC control scheme is incorporated with the LVRT function to support the grid voltage in fulfilling and accomplishing the up-to-date grid codes. The LVRT algorithm is based on a modification of the references of active and reactive powers as functions of the instantaneous grid voltage such that suitable values of P and Q are injected to the grid during voltage sag.The performance of the elaborated FCS-MPC PQ scheme is studied under various operating scenarios, including steady-state and transient conditions. Results demonstrate the validity and effectiveness of the proposed scheme with regard to the achievement of high-performance operation and quick response of grid-tied inverters during normal and fault modes.
基金supported by National Science Foundation of China(61563032,61963025)Project supported by Gansu Basic Research Innovation Group(18JR3RA133)+1 种基金Industrial Support and Guidance Project for Higher Education Institutions of Gansu Province(2019C-05)Open Fund Project of Key Laboratory of Industrial Process Advanced Control of Gansu Province(2019KFJJ02).
文摘Because of system constraints caused by the external environment and grid faults,the conventional maximum power point tracking(MPPT)and inverter control methods of a PV power generation system cannot achieve optimal power output.They can also lead to misjudgments and poor dynamic performance.To address these issues,this paper proposes a new MPPT method of PV modules based on model predictive control(MPC)and a finite control set model predictive current control(FCS-MPCC)of an inverter.Using the identification model of PV arrays,the module-based MPC controller is designed,and maximum output power is achieved by coordinating the optimal combination of spectral wavelength and module temperature.An FCS-MPCC algorithm is then designed to predict the inverter current under different voltage vectors,the optimal voltage vector is selected according to the optimal value function,and the corresponding optimal switching state is applied to power semiconductor devices of the inverter.The MPPT performance of the MPC controller and the responses of the inverter under different constraints are verified,and the steady-state and dynamic control effects of the inverter using FCS-MPCC are compared with the traditional feedforward decoupling PI control in Matlab/Simulink.The results show that MPC has better tracking performance under constraints,and the system has faster and more accurate dynamic response and flexibility than conventional PI control.
基金Supported by the International Science and Technology Cooperation Program of China(2018YFE0125300)the Fundamental Research Funds for the Central Universities(531118010661)+3 种基金the National Natural Science Foundation of China(52061130217)the Innovative Construction Program of Hunan Province of China(2019RS1016)the 111 Project of China(B17016)the Excellent Innovation Youth Program of Changsha of China(KQ2009037).
文摘Herein,a novel wind power grid-connection system based on inductive filtering is proposed to improve grid-connection compatibility,and is implemented in a 50-MW real system.First,the topology and wiring configuration of the proposed system are discussed.Thereafter,an equivalent circuit and mathematical model are established to reveal the filtering characteristics and resonance damping mechanism of the proposed system.Finally,a 50-MW wind farm-based experimental study,which is conducted to validate the effectiveness and availability of the system is discussed.The experimental results show that the main harmonics,power factor,voltage fluctuation,and flicker satisfy national standards.